DE
Eheim logo
Offizielle Bedienungsanleitung

Eheim Pond Air Pump (Air500)

76 Seiten·1.2 MB·Pumpe·PDF·ENJA
Eheim Pond Air Pump (Air500)
Inhaltsverzeichnis 15 Abschnitte Translation of the original operating manual Pond aerator AIR 500/1000 · 1. General user instructions · ⌦A · 2. Application · … AnzeigenAusblenden
Page 1 of the Eheim Pond Air Pump (Air500) user manual — 2. Application
Seite 1 · Zum Vergrößern klicken
Seite 1

Translation of the original operating manual Pond aerator AIR 500/1000

1. General user instructions

Information on using the operating manual

▶Before using the appliance for the first time, the operating manual must be read fully and under-

stood. ▶Consider the operating manual as part of the product and keep in a safe and accessible location.

▶Enclose this operating manual if passing the appliance on to a third party.

Explanation of symbols and notes

Risk of personal injury from dangerous voltage The symbol denotes imminent danger causing severe personal injury or death if the corresponding measures are not taken.

Risk of personal injury from a general source of danger The symbol denotes imminent danger causing severe personal injury or death if the corresponding measures are not taken.

⌦A

Reference to a figure, in this case, reference to figure A

You are prompted for an action.

2. Application

The appliance and all parts included in the scope of delivery are intended for private use and must only be used:

‧ for water aeration ‧ in compliance with the technical data

‧ do not use for commercial or industrial purposes ‧ do not use in swimming ponds ‧ do not immerse in water or other liquids

Page 2 of the Eheim Pond Air Pump (Air500) user manual — Electrical safety
Seite 2 · Zum Vergrößern klicken
Seite 2

3. Safety instructions

Risks for persons and property can arise from this appliance if the appliance is improperly used or not used as intended or if the safety instructions are not heeded.

‧ Do not let the appliance packaging get into the hands of children as

hazards can arise (danger of suffocation!). ‧ This appliance can be used by children aged from 8 years and above

and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and under- stand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Electrical safety

‧ The electrical installations must comply with the international and na-

tional erection specifications. ‧ The appliance is to be supplied through a residual current device (RCD) ‧ having a rated residual operating current not exceeding 30 mA. ‧ Please contact an electrician if there are any questions or problems. ‧ Disconnect the appliance from the mains before all work. ‧ The electrical data of the appliance must match the data of the power

mains. This data is found on the type plate, the packaging and in these instructions. ‧ Extension cables and power distributors must be suitable for outdoor

use (protected against splashing water). ‧ The safety distance of the appliance to the water must be at least 2 m. ‧ Mains connection cables must not have a smaller cross-section than

rubber hose lines with the abbreviation H05RN-F3G0,75. Extension cables must meet the requirements of DIN VDE 0620. ‧ If the supply cord is damaged, it must be replaced by the manufacturer,

its service agent or similarly qualified persons in order to avoid a hazard.

Page 3 of the Eheim Pond Air Pump (Air500) user manual — Safe operation
Seite 3 · Zum Vergrößern klicken
Seite 3

‧ Protect the mains socket and mains plug against moisture. It is recom-

mended to form a drip loop with the mains cable to prevent any water running along the cable to the mains socket. ‧ Only connect the appliance to a correctly installed protective contact

mains socket. ‧ WARNINGUnplug or switch off all appliances in the aquarium or pond

before carrying out maintenance.

Safe operation

‧ Before use, carry out a visual inspection to ensure that the appliance,

especially the mains cable and plug, are undamaged. ‧ Do not use the appliance if it is not working properly or is damaged. ‧ Never use the appliance with a damaged mains cable. ‧ Repairs must only be carried out by an EHEIM service centre. ‧ Do not carry the appliance by the mains cable, and to disconnect from

the mains, always pull on the plug and not on the cable or appliance. ‧ Protect the mains cable against heat, oil and sharp edges. If the con-

nection cable has been laid in the ground or in gravel without an empty conduit, it must not be possible to step on it. ‧ Only carry out the work described in these instructions. ‧ Never make technical modifications to the appliance. ‧ Only use original spare parts and accessories for the appliance. ‧ Only operate the appliance when there are no persons in the pond!

Page 4 of the Eheim Pond Air Pump (Air500) user manual — 5. Operation
Seite 4 · Zum Vergrößern klicken
Seite 4

4. Commissioning

▶Before all assembly and disassembly work, remove the mains plug.

▶Please note that the minimum distance between the pond aerator and pond bank must be no less

than 2 m (⌦C). ▶Please note the maximum immersion depth of the air stones (AIR500 max. 2.20 m/AIR1000 max.

2.80 m) (⌦C). ▶The air stones should be above the pond floor. If the air stones are too close to the pond floor, then

the floor will be disturbed.

1. Shorten the hoses ② to the desired length with scissors ( ⌦A ). 2. Connect the hoses to both connections on the pond aerator ① respectively. 3. Install a check valve in each hose ③.

▶Install the check valve as close as possible to the pump.

▶Please note the installation direction!

4. Connect the air stones ④ to the hose ends.

The pond aerator has two connections for the operation of two air stones. If you only want to operate one air stone, you can join the two connections with the Y-connector (⌦B1). Alternatively, you can also operate several air stones via the Y-connector (⌦B2).

5. Operation

Switching on the pond aerator

▶Place the pond aerator at a minimum of 2 m from the pond bank.

1. Place the pond aerator on a stable surface. 2. Place the air stones above the pond floor. 3. Insert the pond aerator’s mains plug in the mains socket. Attention: The pond aerator starts immediately!

Switching off the pond aerator

1. Remove the mains plug from the mains socket.
Page 5 of the Eheim Pond Air Pump (Air500) user manual — 7. Clearing faults
Seite 5 · Zum Vergrößern klicken
Seite 5

6. Maintenance

▶Before all maintenance work, remove the mains plug.

▶Do not use hard objects or aggressive cleaning agents for cleaning.

The following sections describe maintenance work necessary for optimum and fault-free operation. Regular maintenance prolongs the service life and assures functionality of the pond aerator over a long period.

The air duct and filter must be checked approximately every 8 weeks and cleaned according to the degree of soiling. To do so, proceed as follows:

1. Remove the mains plug. 2. Push the filter cover upwards out of the housing ( ⌦D1 ). 3. Clean the air duct underneath with a brush. 4. Remove the filter from the filter cover ( ⌦D2 ). 5. Clean the filter under running water. 6. Install the filter and filter cover again in reverse order.

7. Clearing faults

▶Before clearing faults, remove the mains plug.

Faults Possible cause Remedy

Pond aerator does not pump No mains voltage ▶Check the mains voltage

▶Check the supply line

Mains plug is not inserted ▶Insert the mains plug in the mains

Pond aerator pumps, but there is no air from the air stones

Check valve is incorrectly installed ▶Install the check valve in the

Air stones are submerged too deep in the pond

▶Please note the maximum instal-

Air duct/filter soiled ▶Clean the air duct and the filter

Pond aerator capacity de- creases

▶Place the air stones higher above

Water is not clear Air stones are too close to the pond floor

the pond floor.

For other faults, please contact EHEIM Service.

Show 4 more labels / short text on this page
Cleaning the filter · socket · correct installation direction · lation depth
Page 6 of the Eheim Pond Air Pump (Air500) user manual — 10. Spare parts
Seite 6 · Zum Vergrößern klicken
Seite 6

8. Decommissioning

1. Clean the appliance 2. Store the appliance in a frost-proof place.

When disposing of the appliance, heed the respective statutory regulations. Information on the disposal of electrical and electronic appliances in the European Union: Within the European Union, disposal of electrically operated appliances is governed by national reg- ulations that are based on the EU Directive 2012/19/EU on waste electrical and electronic equipment (WEEE). The appliance may no longer be disposed of with the municipal or household waste. The appliance will be accepted free of charge at municipal collection points or recycling centres. The prod- uct packaging is made up of recyclable materials. Dispose of them in an environmentally responsible manner and take them for recycling.

9. Technical data

Rated power 5 W 8.5 W

Delivery rate 540 l/h 1000 l/h

Air stone immersion depth, max. 2.20 m 2.80 m

Dimensions (LxWxH) 176 × 118 × 103 mm

Cable length 3 m

Mains voltage/frequency 220 – 240 V / 50 Hz

10. Spare parts

See page 75.

Storing and overwintering · Disposal · Type 500 1000

Frage zu Eheim Pond Air Pump (Air500) stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Eheim Pond Air Pump (Air500)

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Eheim Pond Air Pump (Air500) PDF-Anleitung

76 Seiten·1.2 MB·Pumpe·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…