DE
Blaupunkt logo
Offizielle Bedienungsanleitung

Blaupunkt Air Dehumidifier (ADH701)

120 Seiten·3.2 MB·Haushaltsgeräte·PDF·ENFRITNLJA
Blaupunkt Air Dehumidifier (ADH701)
Inhaltsverzeichnis 10 Abschnitte 页 1 · 页 2 · 页 3 · 页 4 · … AnzeigenAusblenden
Page 1 of the Blaupunkt Air Dehumidifier (ADH701) user manual — 页 1
Seite 1 · Zum Vergrößern klicken
Seite 1

Instruction manual Bedienungsanleitung Instrukcja obsługi Návod k použití Návod na použitie Használati utasítás Navodila

Upute Za Uporabu Εγχειρίδιο Οδηγιών Инструкциязаупотреба Manual De Instructiuni Instrukcijų Vadovas Kasutusjuhendit

Blaupunkt Air Dehumidifier (ADH701) — 页 1 diagram (page 1)
Abb. 1

Odvlaživač zraka Αποξηραντήρας αέρα

Vysoušeč vzduchu Odvlhčovač vzduchu

Uscător de aer Oro sausintuvas

Show 5 more labels / short text on this page
Air dehumidifier · Luftentfeuchter Osuszacz powietrza · Влагоуловител · Légszárító Razvlažilnik zraka · Õhukuivati
Page 2 of the Blaupunkt Air Dehumidifier (ADH701) user manual — 页 2
Seite 2 · Zum Vergrößern klicken
Seite 2

1f 1a 1j 1h

Blaupunkt Air Dehumidifier (ADH701) — 页 2 diagram (page 2)
Abb. 2
Blaupunkt Air Dehumidifier (ADH701) — 页 2 diagram (page 2)
Abb. 3
Blaupunkt Air Dehumidifier (ADH701) — 页 2 diagram (page 2)
Abb. 4
Blaupunkt Air Dehumidifier (ADH701) — 页 2 diagram (page 2)
Abb. 5

1k · 1e · 4a

Page 3 of the Blaupunkt Air Dehumidifier (ADH701) user manual — 页 3
Seite 3 · Zum Vergrößern klicken
Seite 3
SymbolSymbolAlert typeDescription Alert type: WARNING Description: This symbol indicates that the device contains flammable refrigerant. A fire hazard exists if the refrigerant leaks and comes into contact with an external ignition source.NOTEThis symbol indicates the need to read the instructions manual carefully. NOTEThis symbol indicates that a servi specialist should perform the required works in accordance wit the installation manual. NOTEThis symbol indicates that information is available in the instructions manual or installatio manual.
Blaupunkt Air Dehumidifier (ADH701) — 页 3 diagram (page 3)
Abb. 6

Store the device in a room where there are no permanent fire (e.g. operating gas equipment) and ignition sources (e.g. operating electric heater). Store the device in a way that prevents mechanical damage. Do not pierce or expose to fire. Any person involved in servicing or working on a refrigerant circuit should have a current valid certificate issued by an accredited organisation that confirms their qualifications regarding the safe handling of refrigerants according to requirements. Servicing works must be performed only according to the device manufacturer's guidelines. Maintenance or repair works that require the assistance of other trained personnel should be performed under the supervision of a person competent in the use of flammable refrigerants.

Before performing any works on circuits containing

Page 4 of the Blaupunkt Air Dehumidifier (ADH701) user manual — 页 4
Seite 4 · Zum Vergrößern klicken
Seite 4

flammable refrigerants, it is essential to perform a safety inspection to minimise ignition risks. Works should be performed according to a control procedure to minimise the risk of flammable gas or vapours being present during the works. All maintenance personnel and other persons working in the vicinity must be instructed in the nature of the work. Avoid working in confined spaces. Isolate the area around the workplace. Ensure that the area has been inspected by means of the control of flammable materials. Refrigerant may be odourless. The device contains a determined amount (in grams) of R290 refrigerant (see the nameplate). R290 is a refrigerant that meets the requirements of the European directives concerning environmental protection. Do not pierce any element of the refrigerant circuit. When installing, operating or storing the device in a place without adequate ventilation, the room must be designed in such a way that no refrigerant will accumulate (in case of leakage). Refrigerant accumulation can cause a fire or explosion due to the presence of electric heaters, stoves or other sources of ignition.

Transport of equipment containing flammable refrigerant: see transport regulations.

Equipment symbol designation: see local regulations.

Disposal of equipment containing flammable refrigerant: see national regulations.

Equipment/devices storage: store in compliance with the manufacturer's guidelines.

Storage of packed (unsold) equipment: The protective packaging of stored equipment should prevent the refrigerant from leaking in case of mechanical damage to the

Page 5 of the Blaupunkt Air Dehumidifier (ADH701) user manual — 页 5
Seite 5 · Zum Vergrößern klicken
Seite 5

equipment. The maximum number of items of equipment to be stored together is specified in local regulations.

To achieve the utmost in enjoyment and performance, and in order to become familiar with its features, please read this manual carefully before attempting to operate this product.

Before using this device read the instruction manual and follow the instructions inside. The manufacturer is not liable for any damages caused by the misuse of this device due to inappropriate handling. Please keep this manual for future reference. This device is for domestic use only. Do not use for any other purposes.

The device should only be connected to an earthed socket with values corresponding to the values on the rating label. It is necessary to check, if total current consumption of all devices plugged into the wall outlet does not exceed the fuse in the circuit.

If you are using an extension cord, make sure that the total power consumption of the equipment plugged into the extension cord does not exceed the extension cord power rating. Extension cords should be arranged in such a way as to avoid tripping hazards. Make sure the cable is grounded, 3-cores with a socket and an earth cable.

Do not let cord hang over edge of counter, or touch any hot surface.

The device is not designed to be controlled via an external timer, separate remote control, or other equipment that can turn the device on automatically.

Before maintenance work always disconnect the unit from the power supply.

Page 6 of the Blaupunkt Air Dehumidifier (ADH701) user manual — 页 6
Seite 6 · Zum Vergrößern klicken
Seite 6

When unplugging the power cord from electrical outlet, hold it by the plug only and remove the plug carefully. Never pull the cable as it may cause damage to the plug or power cord. Damage to the power cord or plug can lead to an electrocution hazard.

Never leave the product connected to the power source without supervision.

Never put the power cable, the plug or the whole device into the water or any other liquids.

The device should be cleaned regularly complying with the recommendations described in the section on cleaning and maintenance.

Do not place the device near sources of heat, flame, an electric heating element or a hot oven. Do not place on any other device.

This equipment can be used by children aged 8 years and over as long as supervision is provided. People with reduced physical or mental capabilities, as well as people with no previous experience of using this equipment must be supervised and made aware of the risks. The instruction manual should be used as a reference for the safe use of this equipment. Children should not play with the equipment. Children without ensured supervision should not be allowed to perform the cleaning and maintenance of equipment.

Additional precautions should be taken when using this device in the presence of children or pets. Do not allow children to play with the device.

Never use the product close to combustibles.

Never expose the product to atmospheric conditions such as direct sun light or rain, etc... Never use the product in humid conditions (like bathroom or camping house).

Page 7 of the Blaupunkt Air Dehumidifier (ADH701) user manual — 页 7
Seite 7 · Zum Vergrößern klicken
Seite 7

The power cable should be periodically checked for damage. If the power cable is damaged the product should be taken to a professional service location to be fixed or replaced to prevent any hazards from arising.

Never use the product with a damaged power cable or if it was dropped or damaged in any other way or if it does not work properly. Do not try to repair the defected product by yourself as it can lead to electric shock. Always return the damaged device to a professional service in order to repair it. All the repairs should only be performed by authorized service professionals. Any attempted unauthorised repairs performed can be a hazard to the user. Only Original accessories should be used, as well as accessories recommended by the manufacturer. Using accessories which are not recommended by the manufacturer may result in damage of the device and may render the device unsafe for use.

Position the unit to ensure optimal air flow. The dehumidifier should be placed at least 30 cm away from walls, furniture, curtains, etc.

The air-intake and outlet ventilation grilles should be cleaned on a regular basis.

Do not cover the unit or the ventilation grilles. Do not place any objects on the unit.

Do not use the unit near solvents, paints, insecticides or any other chemicals. Do not place or use the unit in areas where it could be exposed to water, e.g. near showers, bathtubs, washbasins, etc. Do not tilt the unit if you suspect that there is any water in

Page 8 of the Blaupunkt Air Dehumidifier (ADH701) user manual — 页 8
Seite 8 · Zum Vergrößern klicken
Seite 8

the water tank.

Place the unit on a surface with a load-carrying capacity of at least 40 kg.

Do not use the unit in spaces smaller than 6 ². m

Do not insert any objects into the inlet or outlet grilles.

Do not direct the air flow towards animals or plants.

The water which accumulates in the dehumidifier is unsuitable for consumption (it is highly demineralised). It should be discharged into the waste-water system. The unit can be used at temperatures 5-32°C. The unit is not designed to maintain a very-low humidity level (below 35%) for a prolonged period.

Before the first use, remove all protective elements such as cardboard, foil, and foamed polystyrene.

Wait at least 3 hours before switching on the unit following transportation, or if it has been turned upside down (i.e. placed in non-vertical position).

- Low voltage directive (LVD) Device is compliant with EU directives:

- Electromagnetic compatibility (EMC)

Device marked CE mark on rating label

When this crossed-out wheeled bin symbol is attached to a product it means that the product is covered by the European Directive 2012/19/EU. Please inform yourself about the local separate collection system for electrical and electronic products. Used appliance should be delivered to the dedicated collecting points due to hazardous components, which may affect the environment. Do not dispose this appliance In the common waste bin.

Environmental information All unnecessary packaging has been omitted. We have tried to make the packaging easy to separate into three materials: cardboard (box), polystyrene foam(buffer) and poly ethylene (bags, protective foam sheet). Your system consists of material which can be recycled and reused if disassembled by a specialized company. Please observe the local regulations regarding the disposal of packaging materials, exhausted batteries and old equipment.

Page 9 of the Blaupunkt Air Dehumidifier (ADH701) user manual — INSTRUCTIONS FOR USE
Seite 9 · Zum Vergrößern klicken
Seite 9

Your products is designed a manufactured with high quality materials and components, which can be recycled and reused.

TECHNICAL SPECIFICATIONS

Rated power390W(27°C, 60%)
Maximum power consumption510W (32°C, 90%)
Maximum current2,4A (32°C, 90%)
Voltage220-240V ~50Hz
Tank volume5,5l
Air-flow rate195m³/h Refrigerant: R290/75g
Maximum noise level≤47dB(A)
Maximum condensation pressure3,3,3,2MPa
Maximum evaporation pressure1,5 Mpa
Recommended air filterBlaupunkt ACC032
1. Control panel 1a. Display 1b. Power on/off button 1c. MODE button

1k. Timer and oscillation indicators 2. Air outlet

3. Air inlet grille
4. Water tank 4a. Water-tank handle

1e. + and – buttons 1d. TIMER button

5. Handle

1f. Oscillation button 1h. Full-water-tank indicator 1i. Operating-mode indicators (Silent/Strong/Continuous/Auto) 1j. Defrosting-mode indicator

6. Water outlet 7. Tube for continuous water drainage (12 mm)
8. Lateral display with LED indicator

INSTRUCTIONS FOR USE

1. Start-up procedure
2. Shutdown procedure Press the power on/off button (1b). The unit will switch on in the last selected mode.

Press the power on/off button (1b). The unit will switch off after a while. Do not interrupt the shutdown procedure by removing the plug from the electrical outlet. 3. To change the operating mode: press the MODE button (1c). Each time you press the button, the mode will change in the following sequence: Auto (automatic mode), Silent (silent mode), Strong (fast- drying mode), Continuous (continuous-drying mode). Press again to return to the Auto mode. The operating mode indicators (1i) show the current operating mode.

Automatic mode: the target humidity level is set at 55%; the fan speed depends on the ambient humidity level. Silent mode: the fan speed is at its lowest - you can set the target humidity level.

Fast-drying mode: the fan speed is at its highest, and the drying process goes on in continuous mode.

Continuous-drying mode: the fan speed is at its lowest, and the drying process goes on in continuous mode.

4. Adjustment of the target humidity level: set the target air-humidity level using the + and – (1e) buttons: 35%-80% (at 5% increments). The target humidity level can only be set in the silent mode.
5. Oscillation of the air-outlet fins: the oscillation mode can be activated or deactivated using the oscillation button (1f).
6. Full-tank indicator: if the tank is full of water, the dehumidifier will terminate the drying process and
Page 10 of the Blaupunkt Air Dehumidifier (ADH701) user manual — 页 10
Seite 10 · Zum Vergrößern klicken
Seite 10

generate a signal tone, and the full tank icon (1h) will light up on the panel.

7. Timer

Delayed-start function: press the timer button (1d) while the unit is connected to the power supply. Each time you press the button, the set-time period will advance by one hour. The unit will switch on at the end of the set time period. The display will show the time remaining to the activation.

To change the set time period, press the timer button (1d). The time indicator on the display will start flashing. While the time indicator is flashing, the set time period will advance each time you press the timer button (1d) – stop at the desired time - until 24 hours is reached, and then it will return to zero. To deactivate the timer, set the time to 0.

Shutdown timer: press the timer button (1d) while the unit is on. Each time you press the button, the set time period will advance by one hour. The unit will switch off at the end of the set time period. After you set the timer, the display will show for a while the time remaining to the shutdown, and then it will change to the humidity level. To check how much time remains to the shutdown, press the timer button (1d) again.

When you change the operating mode, the timer will be deactivated. Set it again.

8. Continuous water drainage To facilitate the continuous water drainage’s bypassing the water tank, insert the continuous-drainage tube (7) into the water outlet (6) and the other end of the tube into the drainage outlet. 9. Automatic defrosting: if the unit’s components are frosted, the dehumidifier will automatically switch into the defrost mode. The fan will remain on, and the compressor will switch off. Once the components have been defrosted, the dehumidifier will automatically return to the normal operating mode.

When the defrost mode is activated, the defrost mode indicator (1j) will light up. 10. Child lock function: to lock the buttons, hold down the + and - buttons (1e) for 5 seconds. To unlock buttons, also hold down the + and - buttons (1e) for 5 seconds.

11. Night mode: to switch off the lateral display and the LED indicator, hold down the MODE button for 5 seconds. To switch on the lateral display and the LED indicator, also hold down the MODE button for 5 seconds.

Frage zu Blaupunkt Air Dehumidifier (ADH701) stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Blaupunkt Air Dehumidifier (ADH701)

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Blaupunkt Air Dehumidifier (ADH701) PDF-Anleitung

120 Seiten·3.2 MB·Haushaltsgeräte·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…