Benutzeranleitung / Produktwartung 53-1000571-01 des Produzenten Brocade Communications Systems
Zur Seite of 48
53-1 0005 7 1- 0 1 Nov e mber 20 0 7 53-1 0005 7 1- 0 1 Brocade 442 4 Blade Ser v er SAN I/O Module Hardware R ef erence Manual.
Copyright © 200 7 Brocade Communications Systems, Inc. All Rights Reserved. Broc ade, the Brocade B w eave lo go, Fabric OS, Fi le Lifecy cle Manager , MyView , Secure F abric OS, SilkW orm, and Stora geX are registered trademarks and the Brocade B wing logo, SAN Heal th, and T apestry a re trademarks of B rocade Communications Systems, Inc.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual iii 53-1000571-01 Rev . A Contents About this document How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Suppor ted har dware and software . . . . . .
iv 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-1000571-01 Rev . A Changing from A ccess Gatewa y Mode to Fabric Switch Mode . . . . 1 7 Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4424 Blade Server SAN I/O Module Hardwa re Reference Manual v 53-0000571-01 About this document This document is a hardware re f erence manual, written f or SAN administrators who are using any Blade Server that supports the Brocade 442 4 Blade Server Fibre Channel SAN I /O Module.
vi 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Document conventions This section describes text formatting co n ventions and impor tant notices f orma ts.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual vii 53-0000571-01 Additional information This section lists additional Br ocade and industr y-specific docu mentation that you might find helpful.
viii 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01 Optional brocade features Optional Broc ade features include: Advanced P er formance Monit oring Enables more effective end-t o-end SAN per forma nce analysis to en hance per formance tuning, increase productivity , optimize resource utilization, and reduce costs.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual ix 53-0000571-01 • Description of any troubleshooting st eps already per formed and results • Serial console and T elnet session logs • syslog me ssage logs 2.
x 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 1 53-0000571-01 Chapter 1 Introducing the SAN I/O Module The Brocade 442 4 is a 2 4-por t Fibre Channel module with 8 ext ernal por ts and 1 6 internal por ts designed f or installation in a Del l Po werEdge M1 000e Blade Ser ver Enclosure.
2 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Features 1 • If the part number is DL -442 4-0002, then the SAN I/O Module is configured to run e xclusively in Access Gate way mode. T o operate in F ull Fa bric Switch mode, y ou must have a Switch license.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 3 53-0000571-01 Features 1 If dark, the port is unlicensed. • The following system LEDs: - One green pow er LED to indicat e module power -on. - One green/amber LED t o in dicate module status.
4 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Hardware Description 1 • For s t at i c PO D , Ta b l e 1 shows the base internal and ext ernal por ts that are licensed, as well as the additional 12 por ts that can be activat ed wi th a POD license.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 5 53-0000571-01 Hardware Description 1 The nonport (SAN I/O Module status) LEDs, sho wn as item 3 of Figure 1 , display SAN I/O Module-level inf ormation as shown in Figure 2 .
6 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 ISL trunking groups 1 Labeling Figures 3 shows the labels appearing on the SAN I/O Module. A second serial label is locat ed beneath the insertion arm on the enclosure (visible only when the arm is ext ended).
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 7 53-0000571-01 Optional features 1 Optional features The SAN I/O Module supports the following optional sof tware, which is activat ed with the purchase of the corresponding license k ey . Applicable options depend on whether the SAN I/O Module operates in Switch or A ccess Gatew ay mode.
8 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Cabling guidelines 1 5. Be sure that you ha ve taken the necessar y prec autions f or electros tatic sensitiv ity; then break the seal warning. 6. Slide the SAN I/O Module out of the antistatic slee ve and insp ect it carefully f or any ob vious defects or shipping damage.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 9 53-0000571-01 Chapter 2 Configuring the SAN I/O Module Use procedures in this chapt er to configure the SA N I/O Module to operate on a netw ork and fabric.
10 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Modify the SAN I/O Module IP address 2 • Access Gat ewa y Adminis trator’s Guide • Web T ools Adm inistrator’s Guide Modify the SAN I/O Module IP address By default, the IP address for the SAN I /O Module is configured as 1 0.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 11 53-0000571-01 Modify the SAN I/O Module IP address 2 c. F rom the Hyper terminal windo w, click the Co nnect drop-do wn menu and select an ava i l a b le C O M p o r t .
12 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Modify the SAN I/O Module IP address 2 • Switch-3 for SAN I/O Module instal led in bay B1. • Switch-4 for SAN I/O Module instal led in bay B2. • Switch-5 for SAN I/O Module instal led in bay C1.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 13 53-0000571-01 Connecting the SAN I/O Module to the Ethernet network 2 Connecting the SAN I/O Module to the Ethernet network Once you ha v.
14 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Connecting the SAN I/O Module to the fabric 2 E_D_TOV: (1000..5000) [2000] WAN_TOV: (0..30000) [0] MAX_HOPS: (7..19) [7] Per-frame Route Priority: (0..1) [0] Long Distance Fabric: (0.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 15 53-0000571-01 Changing from Fabric Switch mode to Access Gateway mode 2 Tie wraps are not recommended f or optical cabl es because they are easily ov er tightened.
16 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Changing from Fabric Switch mode to Access Gateway mode 2 Web Tools Complet e the following st eps to enable Access Gat ewa y mode using Web T ools. 1. F rom the management console, open a Web bro wser .
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 17 53-0000571-01 Changing from Acc ess Gatewa y Mode to Fabric Switch Mode 2 The SAN I/O Module aut omatically reboots and comes back online in Access Gat ew ay mode using a fact or y default F_Port to N_Port mapping.
18 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Connecting to the SAN I/O Module Using Web Tools 2 Activating ports with a POD license Y ou can activat e por ts with a POD license while th e SAN I/O Module is connecte d to existing SANs or bef ore connecting to an existing SAN.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 19 53-0000571-01 Chapter 3 Operating the SAN I/O Module This chapter describes the o peration and int eroperability of the SAN I/O Module.
20 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Accessing the SAN I/O Module 3 Operating system support Brocade F abric OS has no specif ic host OS depende ncies.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 21 53-0000571-01 Interpreting POS T results 3 Secure T elnet access is available using Secure Sh ell (SSH), a network security pr otocol f or secure remote login and other secure networ k s er vices over an insecure network.
22 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Interpreting LED activity 3 Interpreting LED activity Each SAN I/O Module uses LEDs t o indi cate status.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 23 53-0000571-01 Removing and replacin g the SAN I/O Module 3 Locating the serial number Before contacting ser vice s uppor t, be su re to obta in the module’s serial number . Use one of these methods to locat e the number: • Use the CLI and enter the ChassisShow command.
24 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Removing and replacing the SAN I/O Module 3 FIGURE 6 Removing an SFP from a Port 5. R efer to the Hardware Owner’s Manual f or the Blade Server Enclosure to re move and replace the SAN I/O module fro m the enclosure.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 25 53-0000571-01 Appendix A SAN I/O Module specifications This appendix pro vides product specifications and regulatory compliance as a handy reference. Access Gateway Mode default port mapping The 442 4 SAN I/O Module can contain 2 4 total ports.
26 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Weight and physical dimensions A Weight and physical dimensions Ta b l e 6 lists the w eight and physical di mensions of the SAN I/O Module.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 27 53-0000571-01 Architectural specification A Architectural specification The SAN I/O Module meets the specifications shown in Ta b l e 8 . Supported HBAs For a complet e list of interoperable har dwa re, visit the Br ocade Connect Web sit e at: http://www .
28 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Regulatory compliance A Regulatory compliance This section describes the regulatory compliance requirements f or the Brocade 442 4.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 29 53-0000571-01 Regulatory compliance A BSMI statement (Republic of Taiwan).
30 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Regulatory compliance A CE statement ATTENTION This is a Class A product. In a domestic en vironm ent, this pr oduct might cause radio int er ference, and the user might be req uired to tak e corrective measures.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 31 53-0000571-01 Environmental regulatio n compliance A Environmental regulation compliance This section describes the China R OHS envir onmen tal regulatory compliance requirements f or the SAN I/O Module.
32 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Environmental regulation compliance A TS/HS Dual Language Sheet In acco rdance with China's Managem ent Measures on th e Control o f Pollutio n caused by Electroni c Information products (Decree No.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 33 53-0000571-01 Environmental regulatio n compliance A Regulatory certifications Ta b l e 9 lists th e safety and EMC (elec tromagnetic comp atibility ) specifications for which the Switch is cer tified.
34 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 Environmental regulation compliance A Republic of Korea KN2 4 KN22 Russia GOST R IEC 60950-2002 GOST R 5 13 18.22-99 (Class A) G O S T R 51 31 8 . 24 - 9 9 GOST R 5 13 1 7 .3.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 35 53-0000571-01 Index F Fibre Channel Association , xi A access gateway mode 1 changing from fabr ic switch mode 15 default port mapping 25.
36 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01 IP address modify using CMC CLI 11 modify using CMC GUI 12 modify using module CLI 10 modifying default 10 ipAddrSet comman.
4424 Blade Server SAN I/O Module Hardwa re Reference Manual 37 53-0000571-01 terminal session with I/O module 10 trunking 6 U unpacking the SAN I/O Module 7 V VCCI statement 28 vibration 26 W web brow.
38 4424 Blade Server SAN I/O Module Hardware Reference Manua l 53-0000571-01.
Ein wichtiger Punkt beim Kauf des Geräts Brocade Communications Systems 53-1000571-01 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Brocade Communications Systems 53-1000571-01 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Brocade Communications Systems 53-1000571-01 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Brocade Communications Systems 53-1000571-01 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Brocade Communications Systems 53-1000571-01 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Brocade Communications Systems 53-1000571-01 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Brocade Communications Systems 53-1000571-01 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Brocade Communications Systems 53-1000571-01. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Brocade Communications Systems 53-1000571-01 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.