DE
Bresser logo
Offizielle Bedienungsanleitung

Bresser Weather Station

80 Seiten·573 KB·Wetterstation·PDF·ENITJA
Bresser Weather Station
Inhaltsverzeichnis 30 Abschnitte 1 Imprint (German) · 2 Validity note · 3 About this Instruction Manual · 4 General safety instructions · … AnzeigenAusblenden
Page 1 of the Bresser Weather Station user manual — Danger of suffocation!
Seite 1 · Zum Vergrößern klicken
Seite 1

1 Imprint (German)

Gutenbergstr. 2 46414 Rhede Germany

http://www.bresser.de

For any warranty claims or service enquiries, please refer to the information on "Warranty" and "Ser- vice" in this documentation. We apologize for any inconvenience caused by the fact that we cannot process enquiries or submissions sent directly to the manufacturer's address.

Errors and technical changes excepted.

© 2020 Bresser GmbH

All rights reserved.

The reproduction of this documentation - even in extracts - in any form (e.g. photocopy, print, etc.) as well as the use and distribution by means of electronic systems (e.g. image file, website, etc.) without the prior written permission of the manufacturer is prohibited.

The designations and brand names of the respective companies used in this documentation are gen- erally protected by trade, trademark and/or patent law in Germany, the European Union and/or other countries.

2 Validity note

This documentation is valid for the products with the following article numbers:

Manual version1220
Manual designationManual_7002420_ClimaTemp-XXL_de-en-fr-nl-es_BRESSER_v122020a

Always provide information when requesting service.

3 About this Instruction Manual

NOTICE

These operating instructions are to be considered a component of the device.

Read the safety instructions and the operating manual carefully before using this device.

Keep this instruction manual in a safe place for future reference. When the device is sold or given to someone else, the instruction manual must be provided to the new owner/user of the product.

4 General safety instructions

DANGER

Danger of suffocation!

Improper use of this product may result in suffocation, especially for children. It is therefore imperative that you observe the following safety information.

Bresser GmbH · 7002420 · 19 / 80

Page 2 of the Bresser Weather Station user manual — Risk of voltage damage!
Seite 2 · Zum Vergrößern klicken
Seite 2
  • Keep packaging materials (plastic bags, rubber bands, etc.) away from children! There is a DANGER OF CHOKING [These pose a CHOKING HAZZARD]
  • This product contains small parts that can be swallowed by children! There is a DANGER OF CHOKING [These pose a CHOKING HAZZARD]

DANGER

Risk of an electric shock!

This device contains electronic parts that are powered by a power source (AC adapter and/or batter- ies). Improper use of this product may result in electric shock. Electric shock can cause serious or fatal injuries. It is therefore imperative that you observe the following safety information.

  • Never leave children unattended when handling the device! Follow the instructions carefully and do not attempt to power this device with anything other than power sources recommended in this instruction manual, otherwise there is a danger of an electric shock!

DANGER

Explosion hazard!

Improper use of this product may result in fire. It is essential that you observe the following safety in- formation in order to avoid fires.

  • Do not expose the device to high temperatures. Use only the recommended batteries. Do not short-circuit the device or batteries, or throw them into a fire! Excessive heat or improper handling could trigger a short-circuit, a fire or an explosion!

NOTICE

Danger of material damage!

Improper handling may result in damage to the unit and/or accessories. Therefore, use the device only in accordance with the following safety information.

  • Do not disassemble the device! In the event of a defect, please contact your dealer. They will contact the Service Center and can arrange the return of this device for repair if necessary.
  • Do not immerse the unit in water!
  • Do not expose the device to impacts, vibrations, dust, constant high temperatures or excessive humidity. This can result in malfunctions, short-circuits or damage to the batteries and components.
  • Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity. Do not use batteries from different brands or types or with different capacities. Remove batteries from the device if it is not to be used for a longer period of time!

NOTICE

Risk of voltage damage!

The manufacturer is not liable for damage related to improperly installed batteries!

20 / 80

Page 3 of the Bresser Weather Station user manual — 5 Parts overview Base station
Seite 3 · Zum Vergrößern klicken
Seite 3

5 Parts overview Base station

Bresser Weather Station — 5 Parts overview Base station diagram (page 3)
Abb. 1 · 5 Parts overview Base station
Illustration 1All parts of the base station
Bresser Weather Station — 5 Parts overview Base station diagram (page 3)
Abb. 2 · 5 Parts overview Base station

1 Housing 2 Display 3 Indoor sensor 4 MODE/SET button (change display mode or settings) 5 DOWN/RAIN HISTORY button (decrease value or show 30 days precipitation his- tory)

7 RAIN SINCE/CLEAR button (show precip- itation since last reset or delete stored precipitation values)

9 WEATHER/ABS/REL button (set weather or change barometric pressure type)

11 Stand, fold-out 12 Battery compartment Battery compartment cover 14 RAIN ALERT button (set and enable pre- cipitation alert) 15 OUT-TEMP ALERT button (set and en- able outdoor temperature alert)

21 / 80

Page 4 of the Bresser Weather Station user manual — 7 Scope of delivery
Seite 4 · Zum Vergrößern klicken
Seite 4

6 Parts overview Multisensor Set

Bresser Weather Station — 6 Parts overview Multisensor Set diagram (page 4)
Abb. 3 · 6 Parts overview Multisensor Set
Bresser Weather Station — 6 Parts overview Multisensor Set diagram (page 4)
Abb. 4 · 6 Parts overview Multisensor Set
Illustration 2Multisensor Set: Thermo-hygrometer (top left) and windmeter/rain gauge (right)
Bresser Weather Station — 6 Parts overview Multisensor Set diagram (page 4)
Abb. 5 · 6 Parts overview Multisensor Set

1 Wall mount fixture 2 Signal transmission indicator 3 Display 4 Housing 5 °C/°F button (display change between °C or °F)

7 Battery compartment 8 Modular socket 9 Battery compartment cover 10 Wind vane 11 Wind cups 12 Rain gauge 13 Connection cable with modular plug 14 Mounting tube (severeal parts) 15 Mounting shoe 16 Fixing screws 17 Tube clamps 18 Mounting screws and nuts 19 Modular plug for connection to the modu- lar socket on the Base station

7 Scope of delivery

Base unit (A), thermo-hygrometer (B), windmeter/rain gauge (C), connection cable (D), mounting utensils (E)

Also required (not included):

Station: 2 pcs. Mignon batteries (1.5V, AA type) Sensor: 3 pcs. Mignon batteries (1.5V, AA type) Small Phillips screwdriver

22 / 80

Page 5 of the Bresser Weather Station user manual — 8 Screen display
Seite 5 · Zum Vergrößern klicken
Seite 5

8 Screen display

Bresser Weather Station — 8 Screen display diagram (page 5)
Abb. 6 · 8 Screen display
Illustration 3Screen display of the base station

1 AM/PM information in 12-hour time mode 2 Current time (hours:minutes:seconds) 3 Beaufort scale for wind force classification (1 to 12)

4 Outdoor sensor symbol (when measure- ment values are displayed) 5 Wind speed in km/h 6 Wind gust 7 Wind chill (in °C or °F) 8 Total precipitation (30 days) (in MM) 9 Daily precipitation (24 hours) (in MM) 10 Indoor temperature (in °C or °F) 11 Outdoor temperature (in °C or °F) 12 Humidity outdoors (in %) 13 Humidity indoors (in %) 14 Higheset/lowest value for outdoor temper- ature (24 hours history) 15 Wind direction 16 Barometric pressure type (ABS = absolute or REL = relative) 17 Symbol for barometric pressure tendence (rising, steady or falling)

18 Barometric pressure value (in MB/HPA)

19 Weather forecast 20 Symbol for radio signal

23 / 80

Page 6 of the Bresser Weather Station user manual — 10 Setting up power supply
Seite 6 · Zum Vergrößern klicken
Seite 6

21 Current time (seconds) or weekday or alarm time (display depends on the selec- ted display mode)

22 Symbol for active alarm

9 Before commissioning

NOTICE

Avoid connection faults!

In order to avoid connection problems between the devices, the following points must be observed during commissioning.

1. Place the base unit (receiver) and sensor (transmitter) as close together as possible.
2. Connect the power supply to the base unit and wait until the indoor temperature is displayed.
3. Establish power supply for the sensor.
4. Set up/operate the base unit and sensor within the effective transmission range.
5. Make sure that the base unit and the radio sensor are set to the same channel.

When changing the batteries, always remove the batteries in both the base unit and the sensor and reinsert them in the correct order so that the radio connection can be re-established. If one of the two devices is operated via a mains power connection, the power connection for this device must also be disconnected briefly when changing the battery. If, for example, only the batteries in the sensor are re- placed, the signal cannot be received or can no longer be received correctly.

Note that the actual range depends on the building materials used in the building and the position of the base unit and outdoor sensor. External influences (various radio transmitters and other sources of interference) can greatly reduce the possible range. In such cases, we recommend finding other loca- tions for both the base unit and the outdoor sensor. Sometimes a shift of just a few centimetres is enough!

10 Setting up power supply

1. Remove the battery compartment cover.
2. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.
3. Replace the battery compartment cover.
4. Remove the battery compartment cover.
5. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.
6. Replace the battery compartment cover.
Show 4 more labels / short text on this page
23 Moon phase · Base unit · Thermo-Hygrometer · 24 / 80
Page 7 of the Bresser Weather Station user manual — 11 Installing the multisensor set
Seite 7 · Zum Vergrößern klicken
Seite 7

11 Installing the multisensor set

Bresser Weather Station — 11 Installing the multisensor set diagram (page 7)
Abb. 7 · 11 Installing the multisensor set
Illustration 4Mounting example
1. Assemble the individual parts of the mounting tube.
2. Carefully run the connection cable from the windmeter / rain gauge through the mounting tube and the mounting shoe.
3. Insert one end of the mounting tube into the opening below the windmeter / rain gauge and the other end into the opening of the mounting shoe.

25 / 80

Page 8 of the Bresser Weather Station user manual — 14 Setting the wind direction
Seite 8 · Zum Vergrößern klicken
Seite 8
4. Attach the windmeter/rain gauge and the mounting shoe to the mounting tube with the fixing screws through the drill holes.
5. Attach the mounting shoe to a horizontally and vertically aligned pole or a wall with the enclosed mounting material in at least 2 meters height.
6. Remove the battery compartment cover of the thermo-hygrosensor.
7. Insert the modular plug on the other end of the cable into the modular socket of the thermo-hygro sensor.
8. Mount the thermo-hygrosensor below the windmeter/rain gauge.

12 Automatic time setting

After the power supply was established, the clock will automatically search for the radio signal. The clock will automatically search for the radio signal.

If the radio signal is received correctly, the date and time will be set automatically and the radio control signal icon turns on.

If the clock fails to receive the time signal, go ahead with the following steps:

1. Press DOWN/RAIN HISTORY button and UP/RCC/ALARM button for approx. 2 seconds to re-initiate radio signal reception.
2. If the device is still not receiving the signal, the time must be set manually.

Read the detailed manual for more information about manual time setting and other user defined set- tings (see download information on page 2).

13 Manual time setting and other user defined settings

1. In normal display mode, press MODE/SET button for approx. 3 seconds to switch to settings mode.
2. Digits to be set are flashing.
3. Press DOWN/RAIN HISTORY button or UP/RCC/ALARM button to change the value.
4. Press the MODE/SET button to confirm the setting and move to the next setting.
5. Settings order: 12/24 hours mode > RCC on/off > time zone (-12 to +12 hours) > hours > minutes > seconds > year > month > day > language > temperature unit > barometric pressure unit > wind speed unit > precipitation unit > wind direction
6. Finally press MODE/SET button to save the settings and exit settings mode.

14 Setting the wind direction

To adjust the wind direction, proceed as follows:

1. Press the MODE/SET button for approx. 3 seconds to enter the settings mode.
2. Press the MODE/SET button repeatedly until the wind direction setting is shown in the display at the end (all directions flash).
3. Align the wind vane with the wind turbine in a northerly direction (tip points north).
4. Press the UP/RCC/ALARM or DOWN/RAIN HISTORY button to set the wind direction indicator on the display to North.
5. Press the MODE/SET button to confirm the setting.

26 / 80

Page 9 of the Bresser Weather Station user manual — 18 Temperature alarm setting
Seite 9 · Zum Vergrößern klicken
Seite 9

15 Time zone setting

To set a different time zone, proceed as follows:

1. Press and hold MODE button for approx. 3 seconds to change to time setting mode.
2. Press the MODE button multiple times until the display shows the time offset 00 Hr.
3. Press UP or DOWN button to select the desired time deviation in hours (-23 up to +23 hours).
4. Finally press the MODE button to save the settings and exit the setting mode.

16 Display change

In normal display mode, press the DOWN/RCC button to toggle the time display between 12-hour or 24-hour mode (AM/PM time information is displayed or hidden accordingly)

In normal display mode, press the UP/CF button to toggle between °C and °F when displaying the temperature unit.

In normal display mode, press the CH button several times to display channels 1, 2, 3 or automatically alternating one after another.

In normal display mode, press the ALERT button several times to display the set temperature alarm values one after another.

17 Alarm setting

1. Press MODE button to switch to alarm time display.
2. Press and hold ALARM button for approx. 2 seconds to enter the alarm time setting mode (AL).
3. Digits to be set are flashing.
4. Press UP or DOWN button to change the value.
5. Press ALARM button to confirm and continue to the next setting.
6. Settings order: Hours > Minutes
7. Finally press the ALARM button to save the settings and exit the setting mode. Alarm will be activated automatically. The symbol will be displayed.
8. Press MODE button in normal display mode to display the alarm time.
9. Press ALARM button during the alarm time display to disable the alarm. The symbol will not be displayed.

18 Temperature alarm setting

1. In normal time display mode, press DOWN button for approx. 2 seconds to enter temperature alarm time setting mode.
2. Digits to be set are flashing.
3. Settings order: ON/OFF (Temperature alarm on/off) > Temperature highest limit > Temperature lowest limit > Exit
4. Press UP or DOWN button to change the value.
5. Press SET button to confirm and continue to the next setting.
6. The temperature settings mode will be quit automatically after 30 seconds of inactivity. All settings done before will be saved.
7. When outdoor temperature reaches highest or lowest limit, the temperature alarm symbol will flash and an alarm will sound for approx. 3 seonds. This will be repeated with an interval of 1 minute until the temperature has fallen below the limit again.

27 / 80

Page 10 of the Bresser Weather Station user manual — 21 Precipitation
Seite 10 · Zum Vergrößern klicken
Seite 10

19 Receiving measurements automatically

Once batteries are installed, the base station will display the measurement readings. Readings from the remote sensor will be displayed within 3 minutes after powering it on.

20 Temperature alarm setting

1. In normal time display mode, press DOWN button for approx. 2 seconds to enter temperature alarm time setting mode.
2. Digits to be set are flashing.
3. Settings order: ON/OFF (Temperature alarm on/off) > Temperature highest limit > Temperature lowest limit > Exit
4. Press UP or DOWN button to change the value.
5. Press SET button to confirm and continue to the next setting.
6. The temperature settings mode will be quit automatically after 30 seconds of inactivity. All settings done before will be saved.
7. When outdoor temperature reaches highest or lowest limit, the temperature alarm symbol will flash and an alarm will sound for approx. 3 seonds. This will be repeated with an interval of 1 minute until the temperature has fallen below the limit again.

21 Precipitation

The precipitation which was collected over a certain period is displayed on the base station in milli- meters or inches and is based on the current precipitation rate.

Press the RAIN button several times until the desired time range is displayed:

RATE Current precipitation rate in the past hour DAILY Total precipitation rate of the current day, measured from midnight WEEKLY Total precipitation rate of the current week MONTHLY Total precipitation rate of the current month

Select measurement unit (millimeters or inch)

1. Press the RAIN button for approx. 3 seconds to change to measurement unit settings.
2. Press UP or DOWN button to change between mm (millimeters) and in (inch).
3. Finally press the RAIN button to save the settings and exit the setting mode.

Select display mode · 28 / 80

Page 11 of the Bresser Weather Station user manual — 24 Barometric / Atmospheric Pressure
Seite 11 · Zum Vergrößern klicken
Seite 11

22 Set weather status and air pressure above N.N

1. After switching on the unit, press the WEATHER/ABS/REL button for 3 seconds. The weather symbol on the display flashes.
2. Select the graphic symbol corresponding with the current weather status by pressing the UP or DOWN button.
3. Press WEATHER/ABS/REL button to enter the next setting. The air pressure value flashes.
4. Set the current value for the air pressure above N.N. by pressing the UP or DOWN key.
5. NOTICE! Information on the current value for the air pressure above N.N. can be found on the Internet at https://www.dwd.de/DE/leistungen/beobachtung/beobachtung.html
6. Finally, press the WEATHER/ABS/REL button to save the settings and return to the normal display mode.

23 Weather trend

The weather station will calculate a weather trend for the next 12 hours on basis of the measured val- ues.

1 2 3 4 5

Bresser Weather Station — 23 Weather trend diagram (page 11)
Abb. 8 · 23 Weather trend
Illustration 5Weather trend indicators

1 Sunny 2 Partly cloudy 3 Cloudy 4 Rain 5 Snow

24 Barometric / Atmospheric Pressure

Atmospheric Pressure is the pressure at any location on earth, caused by the weight of the column of air above it. One atmospheric pressure refers to the average pressure and gradually decreases as alti- tude increases. Meteorologists use barometers to measure atmospheric pressure. Since variation in atmospheric pressure is greatly affected by weather, it is possible to forecast the weather by measur- ing the changes in pressure.

1. Press the BARO button to enter the setting mode.
2. Press the BARO button again, to change the unit between inHg / mmHg / hPa.
3. Press the BARO button for 3 seconds to change between absolute and relative atmospheric pressure.

29 / 80

Page 12 of the Bresser Weather Station user manual — 25 Wind speed and direction
Seite 12 · Zum Vergrößern klicken
Seite 12
  • ABSOLUTE: the absolute atmospheric pressure of your location.
  • RELATIVE: the relative atmospheric pressure based on the sea level.

Set relative atmospheric pressure value

4. Get the atmospheric pressure data of the sea level (it is also the relative atmospheric pressure data of your home area) through the local weather service, internet and other channels.
5. Hold the BARO button for approx. 3 seconds, until ABSOLUTE or RELATIVE flashes.
6. Press the UP or DOWN button to switch to RELATIVE mode.
7. Press the BARO button again, and the number for RELATIVE flashes.
8. Press UP or DOWN button to change the value.
9. Press the BARO button to save and exit the setting mode.

NOTE

10. The default relative atmospheric pressure value is 1013 mb/hPa (29.91 inHg), which refers to the average atmospheric pressure.
11. When you change the relative atmospheric pressure value, the weather indicators will change along with it.
12. The built-in barometer can notice the environmental absolute atmospheric pressure changes. Based on the data collected, it can predict the weather conditions in the forthcoming 12 hours. Therefore, the weather indicators will change according to the detected absolute atmospheric pressure after you operate the clock for 1 hour.
13. The relative atmospheric pressure is based on the sea level, but it will change with the absolute atmospheric pressure changes after operating the clock for 1 hour.

25 Wind speed and direction

Reading the wind direction

Wind directions appeared in the last 5 minutes (max. 6)

Press the WIND button several times until the desired rate is displayed:

  • AVERAGE: average of all wind speed numbers recorded in the previous 30 seconds
Show 6 more labels / short text on this page
Wind direction indic- · Meaning · ator · Real-time wind direction · Select display mode · 30 / 80
Page 13 of the Bresser Weather Station user manual — 28 Disposal
Seite 13 · Zum Vergrößern klicken
Seite 13
  • GUST: highest wind speed (gust) recorded from last reading

The wind level provides a quick reference on the wind condition and is indicated by a series of text icons:

Wind level LIGHT MODERATE STRONG STORM Speed 1 – 19 km/h 20 – 49 km/h 50 – 88 km/h > 88 km/h

Select wind speed unit

1. Press the WIND button for approx. 3 seconds to enter the setting mode.
2. Press the UP or DOWN button to change the unit between mph (miles per hour), m/s (miles per second), km/h (kilometer per hour) or knots.
3. Press the WIND button to save the settings and exit the setting mode.

26 Wind chill factor

The wind chill factor is shown in the "WIND CHILL" field on the display.

The wind chill factor is based on the common effects of temperature and wind speed.The displayed wind chill is calculated solely from temperature and wind speed and is measured by the outdoor sensor.

27 EC declaration of conformity

Hereby Bresser GmbH declares that the radio equipment type with 7002420 complies with Directive 2014/53/EU. The full text of the EC declaration of conformity is available at the following Internet ad- dress www.bresser.de/download/7002420/CE/7002420_CE.pdf

28 Disposal

Dispose of the packaging materials properly, according to their type, such as paper or card- board. Contact your local waste-disposal service or environmental authority for information on the proper disposal.

Do not dispose of electronic devices in the household garbage!

According to the European Directive 2012/19/EU on Waste Electrical and Electronic Equip- ment and its transposition into national law, used electrical equipment must be collected sep- arately and recycled in an environmentally sound manner.

31 / 80

Page 14 of the Bresser Weather Station user manual — 26 Wind chill factor
Seite 14 · Zum Vergrößern klicken
Seite 14

Batteries and rechargeable batteries must not be disposed of with household waste. You are legally obliged to return used batteries and accumulators and can return the batteries after use either in our sales outlet or in the immediate vicinity (e.g. in the trade or in municipal collection points) free of charge.

Batteries and accumulators are marked with a crossed-out dustbin and the chemical symbol of the pollutant, "Cd" stands for cadmium, "Hg" stands for mercury and "Pb" stands for lead.

32 / 80

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Frage zu Bresser Weather Station stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Bresser Weather Station

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Bresser Weather Station PDF-Anleitung

80 Seiten·573 KB·Wetterstation·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…