OPERATING INSTRUCTIONS FOR:
MDX14

Visit woods.se for more information and updated instruction manuals.
For extended warranty register your product at warranty-woods.com
Instrukcja obsługi PL Bruksanvisning SE
Manual utilizare RO Bruksanvisning NO
Manual de instrucciones ES

Visit our website to:
Get usage advice, updated brochures, trouble shooter and service information.
Register your product for additional services: www.warranty-woods.com
Always use original spare parts. When contacting our Authorised Service Centre, ensure that you have the following data available: Model number, receipt and serial number.



D.
E .
Fan Eco Dryer Auto Dehum
TIMER SPEED MODE POWER
1 2 3 4 5 6







1. SECURITY WARNINGS
Do not let children play with the appliance.
Wood’s dehumidifier have been known as market leaders for many years. Their dehumidifiers are suitable for use in the most demanding climates, where dehumidifying capacity is good even at different temperatures and humidity levels. They are used with good results in premises that become damp such as cellars, garages or summer house. They are also excellent for drying washing, attics, pool rooms and laundry. Being efficient and low on energy consumption. Does not wear out clothes.
Children of less than 3 years should be kept away unless continuously supervised. Keep all packaging away from children. Cleaning and user maintenance shall not be made by children without supervision.
Flammable material. This appliance contains R290/ Propane a flammable refrigerant.
Refer to this manual for safety information.
General Safety This appliance is intended to be used in household and similar applications such as: – basements, crawl spaces; staff kitchen areas in shops, offices and other working environments. The rating plate is located at the back or the side of the dehumidifier. Keep ventilation openings clear of obstruction.
The amount of humidity that the dehumidifier removes depends on the temperature, humidity level and placement. External weather conditions may also affect the performance of the dehumidifier. In cold weather the absolute humidity decreases and thus the extraction of humidity from the air by the dehumidifier is reduced.
Read operators manual.
Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer is not responsible if an incorrect installation and use causes injuries and damages. Always keep the instructions with the appliance for future reference.
Wood’s dehumidifiers are safe in operation and intended for continuous use over many years.
Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. The appliance shall not be stored in a room with operating ignition sources (for example; open flames, an operating gas appliance or an operation electric heater. Do not pierce or burn. Be aware that refrigerants may not contain an odour. Do not use water spray and steam to clean the appliance. Clean the appliance with a moist soft cloth. Only use neutral detergents. Do not use abrasive products, abrasive cleaning pads, solvents or metal objects. If the supply cord is damaged, it must be replaced by the
Condensation occurs when water vapour in the air comes into contact with a cold surface such as cold window or wall. When water vapour is cooled down, condensation occurs, and water-drops are formed. In high air humidity, the air may get musty and mould might get formed, causing damage to a house and its furnishings. This environment may even cause illness for the residents. Mites and spiders also thrive in a damp environment. A dehumidifier with high performance creates a good, healthy humidity level. For greatest efficiency the doors and windows of rooms that are being dehumidified should be kept closed. Removes odours, dries wood and removes moisture from outdoors equipment.

manufacturer, its Authorised Service Centre or similarly qualified persons in order to avoid a hazard.
and extension cables. Make sure not to cause damage to the electrical components (e.g. mains plug, mains cable). Contact the Authorised Service Centre or an electrician to change the electrical components. The mains cable must stay below the level of the mains plug. Connect the mains plug to the mains socket only at the end of the installation. Make sure that there is access to the mains plug after the installation. Do not pull the mains cable to disconnect the appliance. Always pull at the mains plug.
Disconnect the appliance from the mains supply. Cut off the mains cable and discard it. The refrigerant circuit of this appliance is ozone-friendly. Contact your municipal authority for information on how to discard the appliance correctly. Do not cause damage to the part of the cooling unit that is near the heat exchanger.
SAFETY INSTRUCTIONS Installation WARNING Only a qualified person must install this appliance. Remove all the packaging. Do not install or use a damaged appliance. The appliance shall be installed, operated and stored in a room with a floor area larger than 2 m². Obey the installation instruction supplied with the appliance. Always be careful when you move the appliance because it is heavy. Always wear safety gloves.
Use WARNING Risk of injury, burns, electrical shock or fire. Do not change the specification of this appliance.
Make sure the air can circulate around the appliance. Wait at least 4 hours before connecting the appliance to the power supply. This is to allow the oil to flow back in the compressor. Do not install the appliance close to radiators or other heat sources. Do not install the appliance where there is direct sunlight.
Be careful not to cause damage to the refrigerant circuit. It contains propane (R290), a natural gas with a high level of environmental compatibility. This gas is flammable.
Electrical connection WARNING Risk of fire and electrical shock. The appliance must be connected to a grounded outlet. Make sure that the electrical information on the rating plate matcheswith the power supply. If not, contact an electrician. Always use a correctly installed shockproof socket. Do not use multi-plug adapters
If damage occurs to the refrigerant circuit, make sure that there are no flames and sources of ignition in the room. Ventilate the room. Do not put flammable products or items that are wet with flammable products near or on the appliance.
Disposal WARNING Risk of injury.

2. Installation
BEFORE FIRST USE Let the machine stand for 4 hours before use Selecting a Location

Control panel

unit will work as dehumidification, the fan speed is not adjustable. b) When the ambient humidity<60%, the unit will work as fan, the fan speed is not adjustable. c) The humidity level is not adjustable.
Humidity setting is only valid under dehumidification mode.
- The dehumidifier should not be placed
near radiators or other heat sources or exposed to direct sunlight, as it will reduce performance.
- Ideal is to put it in the centre
of the room / area.
Under this mode, compressor shall not work, fan works in low speed by default for ventilation only, fan speed is adjustable, humidity level can’t be set, ambient humidity level (30-90%RH) will indicated on display panel.
DRY MODE
When the water reservoir is full, the dehumidifier will shut off automatically.
Under this mode, compressor will continuously work and fan runs at high speed regardless room humidity. Three minutes delay protection function of compressor is applicable, fan speed and humidity level can’t be adjusted, ambient humidity level (30-90%RH) will indicated on display panel.
If the dehumidifier is transported horizontally, let the dehumidifier stand for a 4 hours before being used. It is very important that the oil runs back into the compressor, otherwise the dehumidifier may be seriously damaged.
Direct water drainage Connect a water hose to the pipe on the back of the dehumidifier. Lead the other end to a drain. Make sure that the water can be drained downwards by gravity.
When the unit works at AUTO MODE, the default humidity level is RH50% a) When the ambient humidity ≥ 70%, the unit will work as strong dehumidification, the fan speed is not adjustable. b) When 50% ≤ the ambient humidity<70%, the unit will work as weak dehumidification, the fan speed is not adjustable. c) When the ambient humidity<50%, the unit will work as fan in low speed, the fan speed is not adjustable. d) The ambient humidity level (30- 90%RH) will indicated on display panel, the humidity is not adjustable.
The air filter prevents dust and dirt from entering the machine, prolonging its life expectancy. It is important the filter is cleaned regularly.
Filter cleaning:
The unit will work at dehumidification mode when power-on for the first time or choose by mode conversion, the fan speed is defaulted high, press UP and DOWN to adjust the setting humidity (35- 85%).
When the unit works at ECO MODE, the default humidity level is RH60%. a) When the ambient humidity ≥ 60%, the

The evaporator in the dehumidifier may defrost automatically if it is operated in the room temperature less than 18 °C. The defrosting device may start up and operate for some time (about 8 minutes) automatically every 40 minutes or even longer.
When the dehumidifier is used in extremely damp environments or when the temperature is below +5˚C, the dehumidifier will stop working. A large amount of ice builds up on the cooling coil. Turn off the dehumidifier and place it a little above floor level so that the ice will melt away.
Please don’t turn off the switch or pull out the power plug of the dehumidifier during the defrosting operation.
Sometimes it may be useful to use a fan heater to make sure that the temperature does not fall below +10˚C. Even if the MDX14 work down to temperatures as low as +5°C, its capacity will increase at higher temperatures as warm air carries more water.
This dehumidifier doesn’t have cooling function. It will produce heat during the operation and can increase the room temperature to 1 to 4°C.
The hydrostat has a margin of error of approx. +/- 5-10%. At lower tem-peratures, the margin of error might increase further.
- Clean the unit with a soft moist cloth. Do
not use solvents or strong cleaners as this might damage the surface of the unit.
Expect higher dehumidification capacity during Autumn / Summer because the outside air is warmer and more humid.
If the dehumidifier requires servicing, you must first contact your local retailer.
2 years product warranty. Please note that the warranty is only valid upon the production of the receipt.
to an grounded power source.
The power source should be
Before storage of the unit, please follow these steps:
220V-240V 50Hz

Dehumidifier does not start - Check that dehumidifier is connected to electricity and that fuse has not gone - If the warning light is on, check that the water reservoir is empty and correctly placed in the dehumidifier. Check that float is free
Does not dehumidify - Check that fan is spinning - Check that air can flow freely through the dehumidifier. Top grid and air filter should be clean and dehumidifier should stand 30cm from walls. - Listen for sound of compressor, but bear in mind that the dehumidifier may stop, when the ambient humidity reach the setting humidity. - Check that a thick coating of ice has not formed on the cooling coils.
High noise level - Increase distance between dehumidifier and surrounding surfaces - Cooling coils may be in contact with one another and cause vibration. Disconnect dehumidifier from electricity and separate coils.
Does not turn off when water reservoir is full
- It is important that the float moves freely in the water reservoir. If it does not, it will not respond to water levels and prevent dehumidifier from stopping
No water enters reservoir - Check for obstruction to drip-tray above water reservoir
FL - Water reservior is full. Empty the water reservior and put it back.
E1 - Temp-humidity sensor failure. Replace the temp-humidity sensor.
If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier.


Dehumidifying at 20˚C and 70% r.h. 6,0 l/ 24h
Recommended limits for use Temp. +5˚C to +35˚C Relative humidity: 30% to 90% Recommended humidity level: appr. 50% RH
Power consumption at 20˚C and 70% r.h. 4,3kWh/24 h
2 years consumer warranty against production faults. Please note that the warranty is only valid upon the production of the receipt. The warranty is only valid if the product is used in accordance with the instructions and security warnings expressed in this manual. The warranty does not cover any damages caused by improper handling of the product.
Dimensions in mm, L x Bx H 293x183x493
*Technical changes and improvements may occur. All values are approximate and may vary due to external circumstances such as temperature, ventilation and humidity.
In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.
Häufige Probleme, wahrscheinliche Ursachen und Lösungen.
| Problem | Mögliche Ursache | Abhilfe | |
|---|---|---|---|
| Dehumidifier does not start | - Check that dehumidifier is connected to electricity and that fuse has not gone - If the warning light is on, check that the water reservoir is empty and correctly placed in the dehumidifier. Check that float is free | p.14 | |
| Does not dehumidify | - Check that fan is spinning - Check that air can flow freely through the dehumidifier. Top grid and air filter should be clean and dehumidifier should stand 30cm from walls. - Listen for sound of compressor, but bear in mind that the dehumidifier may stop, when the ambient humidity reach the setting humidity. - Check that a thick coating of ice has not formed on the cooling coils. | p.14 | |
| High noise level | - Increase distance between dehumidifier and surrounding surfaces - Cooling coils may be in contact with one another and cause vibration. Disconnect dehumidifier from electricity and separate coils. | p.14 | |
| Does not turn off when water reservoir is full | - It is important that the float moves freely in the water reservoir. If it does not, it will not respond to water levels and prevent dehumidifier from stopping | p.14 | |
| No water enters reservoir | - Check for obstruction to drip-tray above water reservoir | p.14 | |
| FL | - Water reservior is full. Empty the water reservior and put it back. | p.14 | |
| E1 | - Temp-humidity sensor failure. Replace the temp-humidity sensor. | p.14 | |
| If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier. | p.14 |
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.