DEHUMIDIFIER

OPERATING INSTRUCTIONS FOR:

MDX14

Woods Dehumidifiers (MDX14) — DEHUMIDIFIER diagram (page 1)
Abb. 1

Visit woods.se for more information and updated instruction manuals.

For extended warranty register your product at warranty-woods.com

Instrukcja obsługi PL Bruksanvisning SE

Manual utilizare RO Bruksanvisning NO

LT

Manual de instrucciones ES

Revision date2020-01-20 Dehumidifier MDX14
Show 11 more labels / short text on this page
Operating Instructions GB · Gebruiksaanwijzing NL · Betjeningsvejledning DK · Naudojimosi instrukcija LT · Käyttöohjeet FI · Lietošanas instrukcija LV · Bedienungsanleitung DE · Kasutusjuhend EE · Guide d’instructions FR · Greek GK · Icelandic IS
Page 2 of the Woods Dehumidifiers (MDX14) user manual — CUSTOMER CARE AND SERVICE
Seite 2 · Zum Vergrößern klicken
Seite 2

Visit our website to:

Get usage advice, updated brochures, trouble shooter and service information.

Register your product for additional services: www.warranty-woods.com

CUSTOMER CARE AND SERVICE

Always use original spare parts. When contacting our Authorised Service Centre, ensure that you have the following data available: Model number, receipt and serial number.

Page 5 of the Woods Dehumidifiers (MDX14) user manual — POWER
Seite 5 · Zum Vergrößern klicken
Seite 5
Woods Dehumidifiers (MDX14) — POWER diagram (page 5)
Abb. 2

D.

E .

Fan Eco Dryer Auto Dehum

POWER

TIMER SPEED MODE POWER

1 2 3 4 5 6

Show 4 more labels / short text on this page
High · Low · Water Full Lock · Lock
Page 6 of the Woods Dehumidifiers (MDX14) user manual — PRODUCT DESCRIPTION
Seite 6 · Zum Vergrößern klicken
Seite 6

PRODUCT DESCRIPTION

Woods Dehumidifiers (MDX14) — PRODUCT DESCRIPTION diagram (page 6)
Abb. 3
Woods Dehumidifiers (MDX14) — PRODUCT DESCRIPTION diagram (page 6)
Abb. 4
Woods Dehumidifiers (MDX14) — PRODUCT DESCRIPTION diagram (page 6)
Abb. 5
Page 7 of the Woods Dehumidifiers (MDX14) user manual — PRODUCT DESCRIPTION
Seite 7 · Zum Vergrößern klicken
Seite 7
Woods Dehumidifiers (MDX14) — PRODUCT DESCRIPTION diagram (page 7)
Abb. 6
Page 8 of the Woods Dehumidifiers (MDX14) user manual — Children and vulnerable people safety
Seite 8 · Zum Vergrößern klicken
Seite 8

WOOD’S ONE OF THE WORLD’S LEADING DEHUMIDIFIERS

1. SECURITY WARNINGS

Do not let children play with the appliance.

Wood’s dehumidifier have been known as market leaders for many years. Their dehumidifiers are suitable for use in the most demanding climates, where dehumidifying capacity is good even at different temperatures and humidity levels. They are used with good results in premises that become damp such as cellars, garages or summer house. They are also excellent for drying washing, attics, pool rooms and laundry. Being efficient and low on energy consumption. Does not wear out clothes.

R290

Children of less than 3 years should be kept away unless continuously supervised. Keep all packaging away from children. Cleaning and user maintenance shall not be made by children without supervision.

Flammable material. This appliance contains R290/ Propane a flammable refrigerant.

Refer to this manual for safety information.

General Safety This appliance is intended to be used in household and similar applications such as: – basements, crawl spaces; staff kitchen areas in shops, offices and other working environments. The rating plate is located at the back or the side of the dehumidifier. Keep ventilation openings clear of obstruction.

The amount of humidity that the dehumidifier removes depends on the temperature, humidity level and placement. External weather conditions may also affect the performance of the dehumidifier. In cold weather the absolute humidity decreases and thus the extraction of humidity from the air by the dehumidifier is reduced.

Read technical manual

Read operators manual.

SAFETY INFORMATION

Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer is not responsible if an incorrect installation and use causes injuries and damages. Always keep the instructions with the appliance for future reference.

Wood’s dehumidifiers are safe in operation and intended for continuous use over many years.

Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. The appliance shall not be stored in a room with operating ignition sources (for example; open flames, an operating gas appliance or an operation electric heater. Do not pierce or burn. Be aware that refrigerants may not contain an odour. Do not use water spray and steam to clean the appliance. Clean the appliance with a moist soft cloth. Only use neutral detergents. Do not use abrasive products, abrasive cleaning pads, solvents or metal objects. If the supply cord is damaged, it must be replaced by the

EXCESSIVE AIR HUMIDITY – A DANGER

Condensation occurs when water vapour in the air comes into contact with a cold surface such as cold window or wall. When water vapour is cooled down, condensation occurs, and water-drops are formed. In high air humidity, the air may get musty and mould might get formed, causing damage to a house and its furnishings. This environment may even cause illness for the residents. Mites and spiders also thrive in a damp environment. A dehumidifier with high performance creates a good, healthy humidity level. For greatest efficiency the doors and windows of rooms that are being dehumidified should be kept closed. Removes odours, dries wood and removes moisture from outdoors equipment.

Children and vulnerable people safety

Page 9 of the Woods Dehumidifiers (MDX14) user manual — WOOD’S ONE OF THE WORLD’S LEADING DEHUMIDIFIERS
Seite 9 · Zum Vergrößern klicken
Seite 9

manufacturer, its Authorised Service Centre or similarly qualified persons in order to avoid a hazard.

and extension cables. Make sure not to cause damage to the electrical components (e.g. mains plug, mains cable). Contact the Authorised Service Centre or an electrician to change the electrical components. The mains cable must stay below the level of the mains plug. Connect the mains plug to the mains socket only at the end of the installation. Make sure that there is access to the mains plug after the installation. Do not pull the mains cable to disconnect the appliance. Always pull at the mains plug.

Disconnect the appliance from the mains supply. Cut off the mains cable and discard it. The refrigerant circuit of this appliance is ozone-friendly. Contact your municipal authority for information on how to discard the appliance correctly. Do not cause damage to the part of the cooling unit that is near the heat exchanger.

SAFETY INSTRUCTIONS Installation WARNING Only a qualified person must install this appliance. Remove all the packaging. Do not install or use a damaged appliance. The appliance shall be installed, operated and stored in a room with a floor area larger than 2 m². Obey the installation instruction supplied with the appliance. Always be careful when you move the appliance because it is heavy. Always wear safety gloves.

Use WARNING Risk of injury, burns, electrical shock or fire. Do not change the specification of this appliance.

Make sure the air can circulate around the appliance. Wait at least 4 hours before connecting the appliance to the power supply. This is to allow the oil to flow back in the compressor. Do not install the appliance close to radiators or other heat sources. Do not install the appliance where there is direct sunlight.

Be careful not to cause damage to the refrigerant circuit. It contains propane (R290), a natural gas with a high level of environmental compatibility. This gas is flammable.

Electrical connection WARNING Risk of fire and electrical shock. The appliance must be connected to a grounded outlet. Make sure that the electrical information on the rating plate matcheswith the power supply. If not, contact an electrician. Always use a correctly installed shockproof socket. Do not use multi-plug adapters

If damage occurs to the refrigerant circuit, make sure that there are no flames and sources of ignition in the room. Ventilate the room. Do not put flammable products or items that are wet with flammable products near or on the appliance.

Disposal WARNING Risk of injury.

Page 10 of the Woods Dehumidifiers (MDX14) user manual — Important
Seite 10 · Zum Vergrößern klicken
Seite 10

SET UP DEHUMIDIFIER FOR INSTALLATION

IMPORTANT:

2. Installation

BEFORE FIRST USE Let the machine stand for 4 hours before use Selecting a Location

Important

1. The dehumidifier must be operated in an enclosed area to be most effective. Close all doors, windows, and other outside openings to the room. The effectiveness of the dehumidifier depends on the rate at which humid air enters the room.
2. Place dehumidifier in a location that does not restrict airflow through the front of the unit.
3. A dehumidifier operating in a room will have little or no effect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area. lt may be necessary to install a second dehumidifier in the enclosed area for satisfactory drying.
4. Ensure that the unit is placed on a stable and flat surface. If the surface is not stable there is a risk of excessive vibration and that water to leak.
5. There should be a minimum of 30 cm clear around the unit.
Page 11 of the Woods Dehumidifiers (MDX14) user manual — F
Seite 11 · Zum Vergrößern klicken
Seite 11

PRODUCT DESCRIPTION

3. Product description

G

1. Control panel

A

2. Filter
1. Front shell
3. Continuous drain port
2. Casters
4. Rear shell
3. Top panel
5. Air outlet
6. Left shell
7. Caster

B

1. Filter
2. Continuous drain port

H

1. Keep the top panel from other objects at least 50cm.
2. Keep a distance of above 30cm between the machine and the surrounding objects or walls.
1. Water tank

D

1. Top panel

E

1. Manual drainage
2. Continuous drainage
1. POWER button: Start or stop the unit
2. TIMER button: Set the timer, query timer and cancel timer.
3. SPEED button: Fan will run at low speed or high speed.
4. UP button: Adjust the humidity or timing.
5. DOWN button: Adjust the humidity or timing.
6. MODE button: Fan --- Eco --- Dryer --- Auto --- Dehumidification

F

1. Front shell
2. Right shell
3. Water tank

Control panel

Page 12 of the Woods Dehumidifiers (MDX14) user manual — ECO MODE
Seite 12 · Zum Vergrößern klicken
Seite 12

PLACEMENT OF DEHUMIDIFIER

unit will work as dehumidification, the fan speed is not adjustable. b) When the ambient humidity<60%, the unit will work as fan, the fan speed is not adjustable. c) The humidity level is not adjustable.

Humidity setting is only valid under dehumidification mode.

- The dehumidifier should not be placed

4. Timer: You can set how long the unit will run or when it will start. You can select 1-24 hours.

near radiators or other heat sources or exposed to direct sunlight, as it will reduce performance.

- Ideal is to put it in the centre

FAN MODE

5. Fan Speed: The speed key is valid only in dehumidification mode and ventilation mode.

of the room / area.

Under this mode, compressor shall not work, fan works in low speed by default for ventilation only, fan speed is adjustable, humidity level can’t be set, ambient humidity level (30-90%RH) will indicated on display panel.

6. Child-lock: Press both “Timer” and “Speed” to set or shut off Child-lock function.

WATER DRAINAGE

DRY MODE

When the water reservoir is full, the dehumidifier will shut off automatically.

Under this mode, compressor will continuously work and fan runs at high speed regardless room humidity. Three minutes delay protection function of compressor is applicable, fan speed and humidity level can’t be adjusted, ambient humidity level (30-90%RH) will indicated on display panel.

1. Disconnect the dehumidifier from the power source. 2. Empty the water reservoir. 3. Put the empty water reservoir back and check that the float moves freely. 4. Connect the dehumidifier to the power source.

USING THE DEHUMIDIFIER

If the dehumidifier is transported horizontally, let the dehumidifier stand for a 4 hours before being used. It is very important that the oil runs back into the compressor, otherwise the dehumidifier may be seriously damaged.

AUTO MODE

Direct water drainage Connect a water hose to the pipe on the back of the dehumidifier. Lead the other end to a drain. Make sure that the water can be drained downwards by gravity.

1. Check that the water reservoir is correctly placed.

When the unit works at AUTO MODE, the default humidity level is RH50% a) When the ambient humidity ≥ 70%, the unit will work as strong dehumidification, the fan speed is not adjustable. b) When 50% ≤ the ambient humidity<70%, the unit will work as weak dehumidification, the fan speed is not adjustable. c) When the ambient humidity<50%, the unit will work as fan in low speed, the fan speed is not adjustable. d) The ambient humidity level (30- 90%RH) will indicated on display panel, the humidity is not adjustable.

2. Connect the dehumidifier to a grounded power source.
3. Set the function or desired humidity level. See the section on the humidity control.

AIR FILTER

The air filter prevents dust and dirt from entering the machine, prolonging its life expectancy. It is important the filter is cleaned regularly.

OPERATION MANUAL

1. Power Button: This button can control the machine on and off.

Filter cleaning:

1. Remove the filter.
2. Mode Button: Press to select the desired mode. It can switch to Normal dehumidification, Eco dehumidification, Auto dehumidification, Ventilation mode and Dry clothes mode.
2. Wash it with warm water and a mild cleansing agent. Alternatively the filter may be vacuum cleaned.

DEHUMIDIFICATION MODE

The unit will work at dehumidification mode when power-on for the first time or choose by mode conversion, the fan speed is defaulted high, press UP and DOWN to adjust the setting humidity (35- 85%).

3. Let the filter dry and put it back.

ECO MODE

When the unit works at ECO MODE, the default humidity level is RH60%. a) When the ambient humidity ≥ 60%, the

3. Humidity can be set between 35% - 85%(5% adjustment factor),
Page 13 of the Woods Dehumidifiers (MDX14) user manual — STORAGE
Seite 13 · Zum Vergrößern klicken
Seite 13

DEFROSTING OPERATION

4. Store in a clean, dry environment.

The evaporator in the dehumidifier may defrost automatically if it is operated in the room temperature less than 18 °C. The defrosting device may start up and operate for some time (about 8 minutes) automatically every 40 minutes or even longer.

HINTS

When the dehumidifier is used in extremely damp environments or when the temperature is below +5˚C, the dehumidifier will stop working. A large amount of ice builds up on the cooling coil. Turn off the dehumidifier and place it a little above floor level so that the ice will melt away.

Please don’t turn off the switch or pull out the power plug of the dehumidifier during the defrosting operation.

Sometimes it may be useful to use a fan heater to make sure that the temperature does not fall below +10˚C. Even if the MDX14 work down to temperatures as low as +5°C, its capacity will increase at higher temperatures as warm air carries more water.

This dehumidifier doesn’t have cooling function. It will produce heat during the operation and can increase the room temperature to 1 to 4°C.

MAINTENANCE

The hydrostat has a margin of error of approx. +/- 5-10%. At lower tem-peratures, the margin of error might increase further.

- Clean the unit with a soft moist cloth. Do

not use solvents or strong cleaners as this might damage the surface of the unit.

Expect higher dehumidification capacity during Autumn / Summer because the outside air is warmer and more humid.

SERVICE

If the dehumidifier requires servicing, you must first contact your local retailer.

WARRANTIES

2 years product warranty. Please note that the warranty is only valid upon the production of the receipt.

to an grounded power source.

The power source should be

STORAGE

Before storage of the unit, please follow these steps:

1. Make sure the water tank is empty. When the unit is switched on, make sure the unit work at Ventilation mode for at least 30 minutes to remove the water inside the unit.
2. Collect and bundle the power cord.
3. Clean the filter.

220V-240V 50Hz

Page 14 of the Woods Dehumidifiers (MDX14) user manual — Guarantees
Seite 14 · Zum Vergrößern klicken
Seite 14

PROBLEM SOLUTION

Dehumidifier does not start - Check that dehumidifier is connected to electricity and that fuse has not gone - If the warning light is on, check that the water reservoir is empty and correctly placed in the dehumidifier. Check that float is free

Does not dehumidify - Check that fan is spinning - Check that air can flow freely through the dehumidifier. Top grid and air filter should be clean and dehumidifier should stand 30cm from walls. - Listen for sound of compressor, but bear in mind that the dehumidifier may stop, when the ambient humidity reach the setting humidity. - Check that a thick coating of ice has not formed on the cooling coils.

High noise level - Increase distance between dehumidifier and surrounding surfaces - Cooling coils may be in contact with one another and cause vibration. Disconnect dehumidifier from electricity and separate coils.

Does not turn off when water reservoir is full

- It is important that the float moves freely in the water reservoir. If it does not, it will not respond to water levels and prevent dehumidifier from stopping

No water enters reservoir - Check for obstruction to drip-tray above water reservoir

FL - Water reservior is full. Empty the water reservior and put it back.

E1 - Temp-humidity sensor failure. Replace the temp-humidity sensor.

If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier.

Woods Dehumidifiers (MDX14) — PROBLEM SOLUTION diagram (page 14)
Abb. 7
Woods Dehumidifiers (MDX14) — PROBLEM SOLUTION diagram (page 14)
Abb. 8

Dehumidifying at 20˚C and 70% r.h. 6,0 l/ 24h

Recommended limits for use Temp. +5˚C to +35˚C Relative humidity: 30% to 90% Recommended humidity level: appr. 50% RH

Power consumption at 20˚C and 70% r.h. 4,3kWh/24 h

Guarantees

2 years consumer warranty against production faults. Please note that the warranty is only valid upon the production of the receipt. The warranty is only valid if the product is used in accordance with the instructions and security warnings expressed in this manual. The warranty does not cover any damages caused by improper handling of the product.

Dimensions in mm, L x Bx H 293x183x493

*Technical changes and improvements may occur. All values are approximate and may vary due to external circumstances such as temperature, ventilation and humidity.

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Reparatur

Fehlerbehebung

Häufige Probleme, wahrscheinliche Ursachen und Lösungen.

ProblemMögliche UrsacheAbhilfe
Dehumidifier does not start- Check that dehumidifier is connected to electricity and that fuse has not gone - If the warning light is on, check that the water reservoir is empty and correctly placed in the dehumidifier. Check that float is free p.14
Does not dehumidify- Check that fan is spinning - Check that air can flow freely through the dehumidifier. Top grid and air filter should be clean and dehumidifier should stand 30cm from walls. - Listen for sound of compressor, but bear in mind that the dehumidifier may stop, when the ambient humidity reach the setting humidity. - Check that a thick coating of ice has not formed on the cooling coils. p.14
High noise level- Increase distance between dehumidifier and surrounding surfaces - Cooling coils may be in contact with one another and cause vibration. Disconnect dehumidifier from electricity and separate coils. p.14
Does not turn off when water reservoir is full- It is important that the float moves freely in the water reservoir. If it does not, it will not respond to water levels and prevent dehumidifier from stopping p.14
No water enters reservoir- Check for obstruction to drip-tray above water reservoir p.14
FL- Water reservior is full. Empty the water reservior and put it back. p.14
E1- Temp-humidity sensor failure. Replace the temp-humidity sensor. p.14
If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier. p.14

Frage zu Woods Dehumidifiers (MDX14) stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Woods Dehumidifiers (MDX14)

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Woods Dehumidifiers (MDX14) PDF-Anleitung

121 Seiten·3.9 MB·Haushaltsgeräte·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…