COOLING UNIT

ColdMachine 50, 54, 55, 84, 85, 86, 94, 95, 96, CS-NC15 VD-01, VD-02, VD-03, VD-04, VD-05, VD-06, VD-07, VD-08,
Cooling unit Installation and Operating Manual 13
Kylaggregat Monterings- och bruksanvisning 206
Kühlaggregat Montage- und Bedienungsanleitung 36
Kjøleaggregat Monterings- og bruksanvisning 229
NO
Groupe frigorifique Instructions de montage et de service 60
Jäähdytysaggregaatti Asennus- ja käyttöohje 251
FI
Холодильный агрегат Инструкция по монтажу и эксплуатации 274
Unidad frigorífica Instrucciones de montaje y de uso 85
ES
Agregat chłodzący Instrukcja montażu i obsługi 300
Unidade de refrigeração Instruções de montagem e manual de instruções 110
Chladiaci agregát Návod na montáž a uvedenie do prevádzky 325
Gruppo refrigerante Istruzioni di montaggio e d’uso 134
Chladicí agregát Návod k montáži a obsluze 348
Koelaggregaat Montagehandleiding en gebruiksaanwijzing 159
NL
Hűtőkészülék Szerelési és használati útmutató 372
Køleaggregat Monterings- og betjeningsvejledning . . .183

© 2021 Dometic Group. The visual appearance of the contents of this manual is protected by copyright and design law. The underlying technical design and the products contained herein may be protected by design, patent or be patent pending. The trademarks mentioned in this manual belong to Dometic Sweden AB. All rights are reserved.


Speicherabruf Discharge of Cold Accum. Décharge de la Plaque










0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 0 2


VD-01, VD-02, VD-03, VD-04, VD-05, VD-07, VD-08, VD-09, VD-18, VD-21





Coldmachine Explanation of symbols
Please read these instructions carefully and follow all instructions, guidelines, and warnings included in this product manual in order to ensure that you install, use, and maintain the product properly at all times. These instructions MUST stay with this product. By using the product, you hereby confirm that you have read all instructions, guidelines, and warnings carefully and that you understand and agree to abide by the terms and conditions as set forth herein. You agree to use this product only for the intended purpose and application and in accordance with the instructions, guidelines, and warnings as set forth in this product manual as well as in accordance with all appli- cable laws and regulations. A failure to read and follow the instructions and warnings set forth herein may result in an injury to yourself and others, damage to your product or damage to other property in the vicinity. This product manual, including the instructions, guidelines, and warnings, and related documentation, may be subject to changes and updates. For up-to-date product information, please visit dometic.com.
1 Explanation of symbols 13
2 Safety instructions 14
3 Scope of delivery 16
4 Accessories 16
5 Intended use 16
6 Technical description 17
7 Installing the cooling unit 18
8 Using the cooling unit 25
9 Use coolant accumulator 27
10 Warranty 28
11 Disposal 28
12 Troubleshooting 29
13 Technical data 31

2.1 General safety D
Safety instructions Coldmachine

Coldmachine Safety instructions

Scope of delivery Coldmachine
1 Cooling unit or evaporator
If you wish to operate the cooling unit from the 230 V AC mains, please use one of the following rectifiers.
Available as accessory (not included in scope of delivery):
CoolPower EPS100 rectifier For devices with BD35F compressor (50/80/CS/CS series)
CoolPower MPS35 rectifier For devices with BD35F compressor (50/80/CS/CS series)
CoolPower MPS50 rectifier For devices with BD50F compressor (90 series)
The cooling unit is suited for building your own refrigerator or cooler.
The cooler unit is suitable for cooling and freezing food. The device is also suitable for use on boats.
This product is only suitable for the intended purpose and application in accordance with these instructions.
This manual provides information that is necessary for proper installation and/or operation of the product. Poor installation and/or improper operating or mainte- nance will result in unsatisfactory performance and a possible failure.
The manufacturer accepts no liability for any injury or damage to the product resulting from:

Dometic reserves the right to change product appearance and product specifications.
The cooling units are suitable for use with 12 V or 24 V DC voltage and can therefore be used for camping or on boats. Furthermore, you can connect them to a 230 V mains supply via the rectifiers (see chapter “Accessories” on page 16).
When used on boats, the cooling unit can withstand a constant heeling of 30°.
The cooling unit must be used together with an evaporator. In addition, you can use an accumulator with or without TEC control. The CS-NC15 comprises a cooling unit and an evaporator.
Use the continuously variable thermostat on the evaporator to set the desired temperature.
The accumulator and TEC program control ensure a high cooling capacity and improve the unit’s efficiency. The accumulator is charged when there is a sufficient supply of power (for example when powered by a mains adapter). In the event of accumulator usage or under-voltage, the coolant is drawn from the accumulator until it is empty. Thus, no power is taken from the battery during this time.
The TEC program control always ensures that
Coldmachine Technical description

Installing the cooling unit Coldmachine
The cooling device is equipped with an electronic device to protect against revers- ing the polarity when connecting to a battery. To protect the battery, the cooling device switches off automatically if the voltage is insufficient (see following table).
Devices without TEC control
Connection voltage Switch-off voltage Restart voltage
24 V 22.8 V 24.2 V
Devices with TEC control
Connection voltage Switch-off voltage Restart voltage
24 V 22.0 V 26.0 V
7 Installing the cooling unit !
For installation and assembly, you will need the following tools:

Coldmachine Installing the cooling unit
Permitted cooling area contents
Make sure that maximum cooling area contents specified are not exceeded for the respective evaporator type (see chapter “Technical data” on page 31).
The maximum cooling area contents are based on a minimum insulation thickness of 35 mm of foam polyurethane with a density of 40 kg/m³. If other insulating materials are used such as styrofoam, double the wall thickness to attain the same level of heat insulation.
The evaporator must be installed in the cooling container (except CS-NC15, the evaporator is premounted).
Observe the following in the process:
NOTICE! For cooling units without valve couplings (ready-to install units): Do not open the refrigerant circuit during installation. You may have to make the wall openings larger to be able to slide the evaporator through them (fig. a, page 6). Or alternatively, you create an opening that allows you to install the cooling lines at the top (fig. b, page 6).
➤Connect the evaporators VD-14N and VD-15 in accordance with fig. 0,
page 6.
➤Connect evaporator VD-16 according to fig. 9, page 6.
➤Connect other evaporators according to fig. i, page 9.
Minimum insulation · Installing the evaporator · Connecting the evaporator

Installing the cooling unit Coldmachine
Keys for the illustrations
No. in fig. 8,
3 Connection plug for DC fan
No. in fig. 9,
No. in fig. 0,
No. in fig. i, page 9 and
fig. j, page 9
4 Switch fig. i or TEC controller fig. j
For cooling units with valve couplings
➤Cut out a hole with a diameter of at least 30 mm (fig. c, page 7) for the cooling
lines. To do this, use a circular cutter.

Coldmachine Installing the cooling unit
It is important to select the proper location for setting up the unit. To ensure trouble- free operation, please note the following points:
The temperature regulator can be mounted either on the outside or inside of the cooling container. The interior temperature is regulated depending on the surface temperature of the evaporator, or for VD-14N and VD-15, depending on the room temperature.
➤Connect the coiled end of the sensor cable to the evaporator (fig. e, page 8,
not VD-14N, VD-15) using the clamping plate. This is premounted on VD-14N, VD-15.
➤Make sure that the sensor line does not make contact anywhere else with the
evaporator or with the suction line.
Mechanical thermostat

Installing the cooling unit Coldmachine
The TEC control must be attached outside of the cooling container. The internal temperature is regulated according to the evaporator surface temperature.
The temperature sensor has been factory-mounted to the accumulator.
➤Connect the temperature sensor with the TEC control via the plug-in coupling.
NOTICE! Only persons who are skilled and knowledgeable in the field of refriger- ation technology may connect one-way couplings. The general regula- tions for handling refrigerants must be observed! The one-way couplings are only suitable for connecting the refrigeration units once. Re-opening or improper connection of the couplings will result in a complete loss of the refrigerant and in the failure of the refrig- eration unit! In such cases, the two previously connected parts of the cooling unit must be disassembled and send in. At the factory, the one-way cou- plings are renewed and the product is refilled with refrigerant.
The two components of the refrigeration unit – the evaporator and the compressor- condenser unit – are supplied separately. The components are connected with one- way couplings. The refrigerant quantity required to operate the entire refrigeration unit is already contained in the two components. A subsequent filling with refrigerant is, therefore, not necessary.
➤Assemble the compressor-condenser unit and the evaporator unit.
➤Remove the protective caps and plugs from the unconnected halves of the one-
way coupling of the compressor-condenser unit and the evaporator unit.
➤Carefully clean the coupling seat and the threaded surface to prevent dirt or for-
TEC control

Coldmachine Installing the cooling unit
➤Apply refrigerant oil to the internal and external threads and to the internal man-
drels (fig. f, page 8).
➤Connect the two halves of the coupling and screw them together by hand at first
(fig. g, page 8). Do not use a wrench!
One-way coupling with union nut:
➤Screw on the coupling half with the union nut using a wrench size 21 mm and a
wrench size 19 mm up to the end of the thread or until a noticeable resistance is felt. Do not tighten the screw connection yet.
The wrench size 19 mm serves as a guide when screwing on the union nut.
Connection of the one-way coupling with external thread:
➤Screw on the coupling half with the union nut using a wrench size 21 mm and a
wrench size 16 mm up to the end of the thread or until a noticeable resistance is felt. Do not tighten the screw connection yet.
The wrench size 16 mm is used for counterholding when screwing on the union nut.
➤Use a pencil to draw a line lengthwise from the union nut to the bracket of the
opposite coupling half.
➤Now tighten the union nut firmly with a torque of 30 Nm or another 1/4 turn. The
offset of the line shows how strongly the one-way coupling was tightened.
This last turn is necessary to ensure a leak-free connection between the coupling halves. I
➤Perform a leak test on the coupling connections. This ensures that the one-way
couplings are correctly connected and the sealing is functional.

Installing the cooling unit Coldmachine
Connecting to a battery
The cooling unit can be operated from a 12 V or a 24 V DC voltage supply. A
➤Determine the required cross section of the cable in relation to the cable length
according to fig. h, page 8.
Key for fig. h, page 8
Co-ordinate axis Meaning Unit
l Cable length m
∅ Cable cross section mm²
➤Before you start up the unit for the first time, check that the operating voltage
matches the battery voltage (see type plate).
➤Connect your cooling unit
– as directly as possible to the pole of the battery or – to a plug socket which is fuse protected with at least 15 A (at 12 V) or 7.5 A (at 24 V). A
For safety reasons the cooling unit is equipped with an electronic system to prevent polarity reversal. This protects the cooling unit when it is connected to a battery.

Coldmachine Using the cooling unit
➤To operate the cooling unit from the 230 V mains, use the rectifier
– CoolPower EPS100 for devices with BD35F compressor (50/80/CS/CS series), – CoolPower MPS35 for devices with BD35F compressor (50/80/CS/CS series), – CoolPower MPS50 for devices with BD50F compressor (90 series). I

Using the cooling unit Coldmachine
Devices without TEC control
➤Switch in the cooling unit by turning the control button clockwise
(fig. 1 A1 or B1, page 3).
If you turn the control button further, you can regulate the temperature. Devices with energy storage function offer a storage activation button (fig. 1 A2, page 3). I
Devices with TEC control
Devices with TEC control are started by actuating the main switch (fig. 2 6, page 3). You can then regulate the temperature (fig. 2 5, page 3) with the temperature selector.
If you do not intend to use the cooling device for a prolonged period, proceed as follows:
➤Devices without TEC control: Turn the control to 0.
(fig. 2 6, page 3).
➤Disconnect the power cable from the battery or pull the DC cable plug out of the
rectifier.
➤Clean the cooling device.
➤Leave the door slightly open over the cover.
This prevents odour build-up.

Coldmachine Use coolant accumulator
No. in fig. 2,
1 Green LED: Indicates that the compressor is working.
2 Yellow LED: indicates that the external power supply is present (voltage is higher than 13.5 V or 27.0 V). The LED flashes if the external power supply is too low (voltage ≤10.7 V or 21.7 V. Version E: ≤10.7 V or 22.0 V).
5 Temperature selector: allows the temperature in the cooling area to be set as required Min. (left limit) = warmest setting Max. (right limit) = coldest setting
6 Main switch: for switching the cooling device on and off. Position 0 = OFF Position – = ON
The accumulator function ensures that cold energy is stored automatically (up to 8 hours) if enough electrical power is available, for example when supplied by a mains adapter.
Stored cooling power is discharged
Explanation · page 3

The accumulator is automatically charged if,
The statutory warranty period applies. If the product is defective, please contact the manufacturer's branch in your country (see dometic.com/dealer) or your retailer.
For repair and warranty processing, please include the following documents when you send in the device:
➤Place the packaging material in the appropriate recycling waste bins, wherever
If you wish to finally dispose of the product, ask your local recycling center or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.
Warranty Coldmachine

LED on the thermal element (fig. 1 2, page 3)
Number of flashes Error type Remedy
1 Battery protection shutdown Check battery voltage, fuse and cable cross section
2 Fan overvoltage shutdown Check condenser and evaporator fan current:
total target value < 0.5 A
3 Compressor start-up fault Reduce load on cooling system:
4 Compressor overload shutdown Reduce load on cooling system:
5 Electronic fuse shutdown Reduce load on cooling system:
Compressor does not run
Fault Possible cause Remedy
UT = 0 V The connection between the battery and the – electronics is interrupted
Main switch defective (if installed) Replace the main switch
Additional supply line fuse has blown (if installed)
UT ≤ UON Battery voltage is too low Charge the battery
Start attempt with UT ≤UOFF
Battery capacity too low Replace the battery
Cable cross section too low Replace the cable (fig. h, page 8)

Fault Possible cause Remedy
Start attempt with UT ≥UON
Ambient temperature too high –
Insufficient ventilation and/or cooling Provide improved ventila- tion for the cooling unit
Condenser is dirty Clean the condenser
Fan defective (if installed) Replace the fan
UT Voltage between the positive and negative electronic terminals
UON Switch-on voltage of the electronics
UOFF Switch-off voltage of the electronics
Interior temperature too low in control setting 1
Fault Possible cause Remedy
Thermostat sensor has no contact on the evaporator
Thermostat defective Change the thermostat
Compressor runs for a long time
Large quantities have been frozen in the freezer compartment
Cooling capacity drops, interior temperature rises
Fault Possible cause Remedy
Compressor runs for a long time/continuously
Evaporator is iced over Defrost the evaporator
Ambient temperature too high –
Insufficient ventilation and/or cooling Provide improved ventilation for the cooling unit
Condenser is dirty Clean the condenser
Fan defective (if installed) Replace the fan
Battery capacity exhausted Charge the battery

Fault Possible cause Remedy
Loud humming A component of the refrigerant circuit can- not move freely (lies against the wall)
Bend the component carefully away from the obstruction
Foreign body jammed between the cooling device and the wall
Remove the foreign body
Fan noise (if installed) Clean the fan blades
Max. cooling area contents:
80 litres 130 litres
Global warming potential (GWP):
Dimensions (W x H x D) in mm:
315 x 140 x 170 386x155x130 220x160x220
Max. cooling area contents:
Global warming potential (GWP):
Dimensions (W x H x D) in mm:

Max. cooling area contents:
Global warming potential (GWP):
Dimensions (W x H x D) in mm:
Max. cooling area contents:
Global warming potential (GWP):
Dimensions (W x H x D) in mm:
Max. cooling area content at 35 mm PU insulation:
80 litres 30 litres 170 litres 130 litres
Max. cooling area content at 50 mm PU insulation:
100 litres 50 litres 200 litres 170 litres
Voltage 12 Vg or 24 Vg

Global warming potential (GWP):
Dimensions (W x H x D) in mm:
300x245x110 275x215x25 380x230x82 375x255x100
CU-50 +
CU-50 +
VD-01
VD-02
VD-07
Max. cooling area content at 35 mm PU insulation:
50 litres 30 litres 60 litres
Max. cooling area content at 50 mm PU insulation:
75 litres 50 litres 80 litres
Max. cooling area content at 35 mm PU insulation:
130 litres 100 litres 160 litres 160 litres
Max. cooling area content at 50 mm PU insulation:
170 litres 130 litres 180 litres 180 litres
Voltage 12 Vg or 24 Vg
Global warming potential (GWP):
Dimensions (W x H x D) in mm:
375x350x25 255x210x90 450x270x340 365x140x270
Coldmachine Technical data

Max. cooling area content at 35 mm PU insulation:
300 litres 200 litres 100 litres
Max. cooling area content at 50 mm PU insulation:
400 litres 250 litres 150 litres
Voltage 12 Vg or 24 Vg
Global warming potential (GWP):
Dimensions (W x H x D) in mm:
Max. cooling area content at 60 mm PU insulation:
130 litres 250 litres
Max. cooling area content at 100 mm PU insulation:
200 litres 300 litres
Voltage 12 Vg or 24 Vg
Global warming potential (GWP):
Dimensions (W x H x D) in mm:
Technical data Coldmachine · 220x275x65 220x275x65 350x250x25 · 330x260x130 1370x305x10

VD-16 for series 80 VD-16 for series 90
Max. cooling area content at 35 mm PU insulation:
120 litres 200 litres
Max. cooling area content at 50 mm PU insulation:
200 litres 250 litres
Voltage 12 Vg or 24 Vg
Global warming potential (GWP):
Dimensions (W x H x D) in mm:
Test/certificates:
The coolant circuit contains R-134a.
Contains fluorinated greenhouse gases
Coldmachine Technical data · 380x300x62