Printed in U.S.A. 1/10 © Copyright 2010 Schneider Electric All Rights Reserved. F-26748-6 Application DuraDrive Direct Coupled Actuators are designed to be used in both damper and valve control ap plications. The following general instruction s ar e for damper applications, refer to the Applicable Liter ature table for valve literature.
2 © Copyright 2010 Schneider Electric All Rights Reserved. F-26748-6 Applicable Literature SPECIFICA TIONS Inputs Control Signal: 4 to 20 mAdc (with the addition of a 50 0 Ohm re sistor - not included) or 2 to 10 Vdc. See Figure-1 through Figure - 8.
F-26748-6 © Copyright 2010 Schneider Electric All Rights Reserved. 3 Minimum Damper Shaf t Length, Stan da rd Da mper shaft must be at least 4-5/8" (1 17 mm) long for standard mounting. Optional Shorter than standard length shafts require the AM-676 shaft extension (order separately).
4 © Copyright 2010 Schneider Electric All Rights Reserved. F-26748-6 TYPICAL APPLICA TIONS (wiring diagrams) MS40-7170 Black White L1 L2 120 Vac GRD Green/Yellow 2 to 10 Vdc Yellow/Black Gray AI COM .
F-26748-6 © Copyright 2010 Schneider Electric All Rights Reserved. 5 MS40-7171 Brown Light Blue L1 L2 240 Vac GRD Green/Yellow Yellow/Black Gray AI COM 2 to 10 Vdc + - Control Signal 1 Position Feedb.
6 © Copyright 2010 Schneider Electric All Rights Reserved. F-26748-6 MS40-7173 Red Black 24H (DC+) 24G (DC-) 24 Vac Transformer or 22-30 Vdc GRD Green/Yellow 4 to 20 mA Yellow/Black Gray AI COM + - 5.
F-26748-6 © Copyright 2010 Schneider Electric All Rights Reserved. 7 INST ALLA TION Inspection Inspect the package for damage. If damaged, notify the appropriate carrier immediately . If undamaged, open the package and inspect the device for obvious damage.
8 © Copyright 2010 Schneider Electric All Rights Reserved. F-26748-6 Precautions General War ni ng : • Electrical shock hazard! Disconnect the powe r supply (line power) before and during installation to prevent electric shock and equipment damage.
F-26748-6 © Copyright 2010 Schneider Electric All Rights Reserved. 9 Mounting Mount th e T AC DuraDrive Actuator directly on the damper shaft in locati ons that clear th e maximum dimensions of the actuator case and allow the actu ator to be mounted flush to the surface of the terminal box and perpendicular to the damper shaft.
10 © Copyright 2010 Schneider Electric All Rights Reserved. F-26748-6 Mounting the Actuator f or Clockwise or Counterc lockwise Dampers The zero (0) position on the posi tion indicator is the normal or spring return po sition.
F-26748-6 © Copyright 2010 Schneider Electric All Rights Reserved. 11 Figure-10 Long Damper Shaft Mounting with Clockwise Spring Return for Normally Cl osed Damper. R 1 1 5 CENTERLINE 1 Two AM-754 Universal Mounting Clamp Assemblies are provided with each actuator.
12 © Copyright 2010 Schneider Electric All Rights Reserved. F-26748-6 Figure-11 Lon g Damper Shaft Mounting with Counterclockwise Spring Return for Normally Closed Damper. 1 5 CENTERLINE 1 Two AM-754 Universal Mounting Clamp Assemblies are provided with each actuator.
F-26748-6 © Copyright 2010 Schneider Electric All Rights Reserved. 13 Short Damper Shafts See Figure-13 for installation of actuator using the AM-676 Un iversal Shaft Extension.
14 © Copyright 2010 Schneider Electric All Rights Reserved. F-26748-6 Wiring Requirement s Control and Power Leads Remove blue plastic thread protectors b efore installing conduit fittings. See Figure-1 throug h Figure 8 for typical wiring applications and T able-3 for maximum wire lengths.
F-26748-6 © Copyright 2010 Schneider Electric All Rights Reserved. 15 CHECKOUT This procedure is for checking out a normally closed actuator that is typically moun ted unpowered. It is possible to mount the actuato r with power applied for special applications.
Copyright 2010, Schneider Ele ctric All brand names, trademarks and regist ered trademarks are the property of t heir respective owners. Information cont ained within this document is subject to chang e without notice. F-26748-6 www .schneider-electric.
Ein wichtiger Punkt beim Kauf des Geräts 3Com MS40-717X (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie 3Com MS40-717X noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für 3Com MS40-717X - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von 3Com MS40-717X reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über 3Com MS40-717X erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon 3Com MS40-717X besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von 3Com MS40-717X verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit 3Com MS40-717X. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei 3Com MS40-717X gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.