Guide to Using this Manual Safety Precautions and Working Techniques

– Do not use the machine if anyone not wearing protective clothing is in the working area.

Special safety precau- tions must be observed when using this machine because it uses electrical power.

– Before starting any work on the machine, e. g., cleaning, servicing, replacement of parts – unplug the power plug!

All the pictograms attached to the machine are shown and explained in this manual.

Observe the national safety regulations issued, e. g. by the employers' liability insurance association, social security institutions, occupational safety and health authorities or other organizations.

When not using the machine, it must be put down in such a way that it does not endanger anyone. Ensure that the machine cannot be used without authorization; unplug the power cord.

It is important that you carefully read the entire Instruction Manual before using the machine for the first time and keep it in a safe place for future ref- erence. Non-compliance with the Instruction Man- ual may cause serious or even fatal injury.

WARNING

Persons who are unable to operate the machine safely due to limited physical, sensory or mental capacity may only use the machine under the supervision of or after instruction by a responsible person.

NOTICE

The user is responsible for accidents or risks involving third parties or their property.

WARNING

– Minors should never be allowed to use the high-pressure cleaner – except for young trainees over the age of 16 when working under supervision.

If using the machine for the first time: Have your STIHL dealer or another expert show you how to use it safely.

STIHL's philosophy is to continually improve all of its products. For this reason we may modify the design, engineering and appearance of our products periodically.

In some countries, operation of machines that emit noise may be restricted by municipal regulations. Observe national regulations.

– Supervise children to ensure that they do not play with the machine.

Therefore, some changes, modifications and improvements may not be covered in this manual.

– The machine should only be provided or loaned to people familiar with this model and its operation. The instruction manual should always be handed over with the machine.

Always check that the machine is in good working order before starting work. Pay particular attention to the power cord, mains plug, high-pressure hose, spray attachment and safety mechanisms.

Pictograms · Symbols in text · Engineering improvements

Page 3 of the Stihl RE163 user manual — WARNING
Seite 3 · Zum Vergrößern klicken
Seite 3

Never operate the machine with a defective high-pressure hose – ensure that it is replaced immediately.

Contact a servicing dealer if in doubt. Use only high-quality accessories, Otherwise, there may be a risk of accidents or damage to the machine.

Wear shoes with non-slip soles.

The machine may only be used when all parts are in perfect working order.

Wear goggles and pro- tective clothing. STIHL recommends that a boilersuit be worn in order to reduce the risk of injury due to accidental exposure to the high- pressure jet.

– STIHL recommends the use of genuine STIHL parts and accessories. These have been optimized for the product and the user's requirements.

The high-pressure hose must not be driven over, pulled, buckled or twisted.

Do not use the high-pressure hose or power cord to pull or transport the machine.

Never modify the machine in any way, as this could be extremely dangerous. STIHL excludes all liability for personal injury and damage to property caused while using unauthorized attachments.

The high-pressure hose must be approved for the permissible excess pressure of the machine.

The permissible excess pressure, the maximum permitted temperature and the date of manufacture are stated on the cladding of the high-pressure hose. The permissible pressure and date of manufacture are specified on the fittings.

When transporting the machine in or on a vehicle, it must be secured, e.g. with straps, so that it cannot slip or tip over.

The machine may only be operated by people who are fit, in good physical health and in good mental condition. If you have any condition that might be aggravated by strenuous work, check with your doctor before operating a machine.

Antifreeze is recommended if the machine and accessories are to be transported at temperatures near or below 0 °C (32 °F) - see “Storage”.

Accessories and spare parts

WARNING

– High-pressure hoses, fittings and couplings are important for machine safety. Only high-pressure hoses, fittings, couplings and other accessories which have been approved by STIHL for this machine or technically equivalent parts may be mounted on the machine.

Anyone who has consumed alcohol, medicines affecting their ability to react or drugs must not operate the machine.

WARNING

– The machine was designed for use with the detergents offered or recommended by the manufacturer.

– Use only detergents that are approved for use with high-pressure cleaners. Use of unsuitable detergents can cause damage to health, as well as to the machine and the object to be cleaned. Contact a servicing dealer if in doubt.

The high-pressure cleaner can be used to clean motor vehicles, machines, tanks, facades or stables and to remove rust without dust or sparks.

Other uses are not permitted and may lead to accidents or damage to the machine.

Show 5 more labels / short text on this page
Clothing and equipment · Transporting the machine · Physical suitability · Detergents · Spheres of application
Page 4 of the Stihl RE163 user manual — WARNING
Seite 4 · Zum Vergrößern klicken
Seite 4

– Always use detergent in the specified dosage – follow the corresponding instructions for use of the detergent.

Inspecting the high-pressure cleaner

– The insulation on the power cord and any extension cord, the plug and the coupling must be fully intact

WARNING

– The high-pressure cleaner should only be used if it is in full working order – risk of accident!

– Never touch the power plug, power cord and extension cord and electrical plug connections with wet hands

– Chemical detergents may contain physiologically harmful (toxic, caustic, irritant), flammable or explosive substances. In the event of skin or eye contact with detergent, flush the affected body parts with plenty of clean water immediately. If detergent is swallowed, seek medical attention immediately. Note the manufacturer's safety data sheets!

– It must be possible to move the switch to the 0 position easily

WARNING

– The switch must be in the 0 position

Route the power cord and extension cord properly:

– Inspect the high-pressure hose, spray attachment and safety mechanisms for damage

– Observe the minimum cross-section of the individual cords – see "Connecting the machine to the power supply"

– High-pressure hose and spray attachment in good condition (clean, moving easily) and correctly assembled

– Route and mark the power cord so that it cannot become damaged and no one is endangered – danger of stumbling!

Do not connect the high- pressure cleaner directly to the drinking water main.

– For good control of the machine, the handles should be clean and dry with no oil or dirt on them

– Use of unsuitable extension cords can be dangerous. Use only extension cords that are approved for outdoor use and are correspondingly marked and have a sufficient cross-section

– Never attempt to modify the controls or safety devices

Only connect the high-pressure cleaner to the drinking water main in conjunction with a backflow preventer – see "Special accessories".

WARNING

– The connector and coupling of the extension cord must be waterproof and not lie in water

Minimize the risk of electrical shock:

WARNING

– Voltage and frequency of the machine (see rating plate) must match the voltage and frequency of the mains supply

– If drinking water has passed through the backflow preventer, it can no longer be regarded as drinking water.

– It is advisable to keep the plug connection at least 60 mm above the ground/floor, e. g. by using a cable reel

– Examine the power cord, power plug and extension cord for damage. Damaged cords, couplings and plugs or power cords that do not comply with the regulations must not be used

– don't let the cord rub against edges or pointed or sharp objects

Do not use the machine with dirty water.

If there is a risk that dirty water will occur (e. g., flowing sand), an appropriate water filter must be used.

– don't squeeze the cord under doors or windows

– Only connect the machine to a correctly installed power socket

Before starting work · Electrical connection

Page 5 of the Stihl RE163 user manual — WARNING
Seite 5 · Zum Vergrößern klicken
Seite 5

– if cords become snarled – unplug the power plug and unsnarl the cord

Never direct the high- pressure jet against your- self or other people, not even to clean clothing or shoes – risk of injury!

between the high-pressure hose and the surface when cleaning to avoid any damage to the surface being cleaned.

– always unroll the power cord from the cable reel completely to avoid risk of fire due to overheating

The trigger on the spray gun must move easily and automatically return to its starting position when released.

Ensure you always have a firm and safe footing.

Hold the spray attachment firmly with both hands in order safely to withstand the kickback force and additional torque produced when using spray attachments with angled spray lance.

Beware of slipping on ice, water, snow or uneven ground!

WARNING

Keep the high-pressure cleaner as far away as possible from the object being cleaned.

– Never draw in fluids containing solvents or undiluted acids and solvents (e. g., gasoline, heating oil, paint thinner or acetone). These substances damage the materials used in the machine. The spray is highly combustible, explosive and poisonous.

Ensure that the power cord and the high- pressure hose are not damaged by being driven over, squashed or pulled; protect them against heat and oil.

The machine may only be operated in an upright position. Do not cover the machine and ensure adequate motor ventilation.

Do not touch the power cord with the high-pressure jet.

Do not direct the high-pressure jet against animals.

If the machine is subjected to unusually high loads for which it was not designed (e. g., heavy impact or a fall), always check that it is in good condition before continuing work - refer also to the chapter "Before starting work". Also make certain that the safety mechanisms are working properly. Never continue using a machine that is not in perfect working order. Consult a servicing dealer if in doubt.

The plug must be discon- nected immediately if the cord is damaged – dan- ger of electrocution!

Do not direct the high-pressure jet onto places you cannot see.

Children, animals and bystanders must remain at a distance.

Never direct the high- pressure jet or water hose against the machine itself or against other electrical appliances and equipment – danger of short-circuiting!

Hazardous substances (e. g. asbestos or oil) must not be allowed to escape into the environment unchecked when working with the machine. The applicable environmental regulations must be observed without fail.

Before leaving the machine: Switch off the machine – unplug the power cord.

Surfaces of asbestos cement must never be cleaned with a high-pressure jet. Hazardous, breathable asbestos fibers may be released in addition to the dirt. The danger is greatest when the washed surface has dried.

Never direct the high- pressure jet or water hose against electrical equipment, connections and power cords – dan- ger of short-circuiting!

When the safety equipment is activated, excessive pressure is returned to the intake side of the pump via a safety valve. This safety feature has been set by the manufacturer and must not be adjusted.

Delicate parts made of rubber, fabric or similar materials must not be cleaned with a pencil jet, e. g. from the rotary nozzle. Maintain a sufficient distance

During work · Safety equipment

Page 6 of the Stihl RE163 user manual — Assembling the Unit
Seite 6 · Zum Vergrößern klicken
Seite 6

The machine must be serviced regularly. Do not attempt any maintenance or repair work not described in the Instruction Manual. All other work should be carried out by a servicing dealer.

Assembling the Unit

Switch off the machine before leav- ing it!

The following accessory parts must be fitted before using the machine for the first time.

STIHL recommends the use of genuine STIHL spare parts. Such parts have been optimized for the machine and the user's requirements.

Holders for spray attachment

– Unplug the power plug from the socket

STIHL recommends that maintenance and repair work be carried out only by authorized STIHL dealers. STIHL dealers receive regular training and are supplied with technical information.

Stihl RE163 — Assembling the Unit diagram (page 6)
Abb. 1 · Assembling the Unit

– Disconnect water intake hose between machine and water supply

Never unplug the power plug by pulling on the cord: always grip the plug itself.

Stihl RE163 — Assembling the Unit diagram (page 6)
Abb. 2 · Assembling the Unit

N Slide the upper holder into the mount on the handle and fasten it with the screw

Before starting any work on the machine: Always disconnect the machine from the mains power supply.

Stihl RE163 — Assembling the Unit diagram (page 6)
Abb. 3 · Assembling the Unit

– Use only high-quality spare parts. Otherwise, there may be a risk of accidents or damage to the machine. Contact a servicing dealer if in doubt.

N Slide the lower holder into the mount on the housing – until it engages

– To avoid risks, work on the machine (e. g., power cord replacement) may only be carried out by qualified electricians.

Clean plastic parts with a cloth. Harsh detergents can damage the plastic.

Cleaning ventilation slots in motor housing as needed.

After finishing work · Maintenance and repairs

Page 7 of the Stihl RE163 user manual — RE 143, RE 163
Seite 7 · Zum Vergrößern klicken
Seite 7

Connector on water inlet

Stihl RE163 — RE 143, RE 163 diagram (page 7)
Abb. 4
Stihl RE163 — RE 143, RE 163 diagram (page 7)
Abb. 5

N Remove screw (4)

N Fasten the holder for the flat hose cassette with the included screws (3)

N Fasten the catch hook for the flat hose cassette (5) with the included screw (6)

N Attach the connector (1) to the water inlet (2) and tighten it by hand

N Fasten the catch hook for the flat hose cassette with the included screw (4)

Installing the holder for versions without included flat hose cassette

Holder for flat hose cassette

RE 143, RE 163

Depending on the country, the flat hose cassette is included or is available as a special accessory.

Stihl RE163 — RE 143, RE 163 diagram (page 7)
Abb. 6
Stihl RE163 — RE 143, RE 163 diagram (page 7)
Abb. 7

The holders for the flat hose cassette are included in all versions and can be installed as needed.

Installing the holder for versions with included flat hose cassette

N Remove the screws (1) from the spray gun holder

Stihl RE163 — RE 143, RE 163 diagram (page 7)
Abb. 8

N Position the holder (1) for the high- pressure hose on the bottom of the handle and fasten it with the screws (2)

N Remove screw (2)

N Fasten the holder for the flat hose cassette (1) to the holder on the spray gun (3) with the included screws (2)

Page 8 of the Stihl RE163 user manual — RE 143 PLUS, RE 163 PLUS
Seite 8 · Zum Vergrößern klicken
Seite 8

RE 143 PLUS, RE 163 PLUS

Transporting the Unit

Fitting, removing spray lance

Stihl RE163 — RE 143 PLUS, RE 163 PLUS diagram (page 8)
Abb. 9
Stihl RE163 — RE 143 PLUS, RE 163 PLUS diagram (page 8)
Abb. 10
Stihl RE163 — RE 143 PLUS, RE 163 PLUS diagram (page 8)
Abb. 11

N Slide the crank into the hose reel – until it engages

N Press button (1) and pull handle (2) upward as far as it will go

N Press the spray lance (1) into the mount on the spray gun (2), turn it by 90° so that it engages

N Release button and pull/push on the handle again until the telescopic shafts engage

N Press the spray lance (1) into the mount on the spray gun (2), turn it by 90° and pull it out of the mount

Stihl RE163 — RE 143 PLUS, RE 163 PLUS diagram (page 8)
Abb. 12
Stihl RE163 — RE 143 PLUS, RE 163 PLUS diagram (page 8)
Abb. 13

The machine can be carried using the transport handle.

N Slide nozzle (3) into the mount on the spray lance (1)

N Hold down the nozzle (3) and twist it by 90° to lock it

Show 5 more labels / short text on this page
Height adjustable handle · Spray lance · Removing · Carrying handle · Nozzle
Page 9 of the Stihl RE163 user manual — RE 143 PLUS, RE 163 PLUS
Seite 9 · Zum Vergrößern klicken
Seite 9

Fitting, removing highpressure hose

Disconnecting the high-pressure hose

N Press the nozzle (3) into the mount and twist it by 90° to unlock it

Stihl RE163 — Fitting, removing highpressure hose diagram (page 9)
Abb. 14 · Fitting, removing highpressure hose

RE 143, RE 163

Connecting the high-pressure hose

Stihl RE163 — RE 143, RE 163 diagram (page 9)
Abb. 15

N Pull out the spring clip (1) and pull the high-pressure hose (2) out of the connector

Connecting the high-pressure hose

N Push the high-pressure hose (2) onto the connector of the hose reel

N Push high-pressure hose onto the connector (2)

N Push the spring clip (1) into the connector

N Attach union nut (1) and screw it on and tighten by hand

High-pressure hose and spray gun

Disconnecting the high-pressure hose

N Unscrew the union nut (1)

N Pull high-pressure hose off of connector (2)

Stihl RE163 — RE 143, RE 163 diagram (page 9)
Abb. 16

RE 143 PLUS, RE 163 PLUS

The high-pressure hose is already connected.

N Push the connector of the high- pressure hose (3) into the mount on the spray gun (4) – until it engages

N Actuate the safety catch (5) and pull the high-pressure hose (3) out of the mount on the spray gun

Removing · Fitting · Removing

Page 10 of the Stihl RE163 user manual — Connecting the water supply
Seite 10 · Zum Vergrößern klicken
Seite 10

Flat hose* Connecting

Connecting the water supply

As a rule, always use only one high- pressure hose extension – see "Special accessories"

Stihl RE163 — Connecting the water supply diagram (page 10)
Abb. 17 · Connecting the water supply

In suction operation, the machine can also be connected to rivers, lakes, cisterns and tanks, etc. – see "Connecting to a pressureless water supply".

Briefly rinse out the hose before connecting it to the machine to prevent sand and other particles from entering the machine.

N Press the catch hook (1) and fold out the flat hose cassette (2)

N Remove the flat hose cassette (2) upward from the holder

N Connect hose to water supply (1/2" diameter, length at least 10 m to absorb pressure surges. Maximum length 25 m)

Stihl RE163 — Connecting the water supply diagram (page 10)
Abb. 18 · Connecting the water supply
Stihl RE163 — Connecting the water supply diagram (page 10)
Abb. 19 · Connecting the water supply

N Connect the flat hose to the water supply

N Push the coupling (1) on to the hose connector (2)

N Turn on water supply

* Depending on the country, the flat hose cassette is included or is available as a special accessory

High-pressure hose extension · Connecting the hose

Page 11 of the Stihl RE163 user manual — NOTICE
Seite 11 · Zum Vergrößern klicken
Seite 11
Stihl RE163 — Connecting to a pressureless water supply diagram (page 11)
Abb. 20 · Connecting to a pressureless water supply

Connection to the drinking water main

Connecting to a pressureless water supply

Stihl RE163 — Connecting to a pressureless water supply diagram (page 11)
Abb. 21 · Connecting to a pressureless water supply

The high-pressure cleaner can only be used in suction operation with the suction set (special accessory).

NOTICE

N Unroll the flat hose (3) from the flat hose cassette completely

As a rule, it is advisable to use a water filter.

N Open the safety latch (4) and remove the end of the house with the coupling

N Connect the machine to the pressurized water supply and start it up briefly in accordance with the Instruction Manual

N Lay out the flat hose so that it is free from kinks or loops

N Switch off the machine

N Disconnect the spray attachment from the high-pressure hose

Stihl RE163 — NOTICE diagram (page 11)
Abb. 22

N Unscrew the hose coupling from the water connection

When hooking up to the drinking water main, a backflow preventer (in accordance with IEC/EN 60335-2-79) must be installed between the water tap and the hose.

N Connect the suction set to the water connection with the included connector

Always use the connector included in the suction set. The hose couplings included as standard with the high- pressure cleaner are not leakproof in suction operation and thus are not suitable for drawing in water.

N Push the coupling (5) on to the hose connector (6)

If drinking water has passed through the backflow preventer, it can no longer be regarded as drinking water.

N Turn on water supply

Follow the rules laid down by the local water supply company to prevent water flowing back from the high-pressure cleaner into the drinking water main.

N Fill the suction hose with water and immerse the suction cup of the suction hose in the water tank – do not use dirty water

N Hold down the high-pressure hose by hand

N Switch on the machine

N Wait until a steady jet exits the high- pressure hose

Page 12 of the Stihl RE163 user manual — Connecting to Power Supply
Seite 12 · Zum Vergrößern klicken
Seite 12

N Switch off the machine

Connecting to Power Supply

Connection to the power supply socket

N Connect spray attachment

Before connection to the power supply, check that the machine is switched off – see "Switching off the machine"

N Switch on the machine with the spray gun open

The voltage and frequency of the machine (see rating plate) must match the voltage and frequency of the power connection.

N Actuate the spray gun several times briefly in order to bleed the air out of the machine as quickly as possible

The minimum fuse protection of the power connection must comply with the specifications – see "Specifications".

The machine must be connected to the power supply via an earth-leakage circuit breaker to disconnect the power supply if the differential current to earth exceeds 30 mA for 30 ms.

N Swivel the lower holder upward and remove the power cord

The power connection must correspond to IEC 60364-1 and relevant national regulations.

N Plug the power cord or extension cord into a properly installed outlet

When the machine is switched on, voltage fluctuations that occur under unfavorable mains conditions (high power line impedance) may negatively affect other connected electrical appliances. Trouble is not anticipated at power line impedances less than 0.15 ohms.

The extension cord must have the following minimum cross-section depending on the mains voltage and cord length.

Cord length Minimum cross- section 220 V – 240 V: up to 20 m 1.5 mm2

20 m to 50 m 2.5 mm2

Page 13 of the Stihl RE163 user manual — NOTICE
Seite 13 · Zum Vergrößern klicken
Seite 13

Switching On

Working

N Turn on water supply

NOTICE

Actuating the spray gun

Do not buckle or loop the high-pressure hose.

NOTICE

N Point the spray gun at the object to be cleaned – never at persons!

The machine may only be switched on when the water intake hose is connected and the water supply has been turned on. Otherwise the machine may be damaged due to lack of water.

Do not place any heavy objects on the high-pressure hose, and do not drive any vehicles over it.

N Point the rotary nozzle downwards when starting (if fitted)

Stihl RE163 — NOTICE diagram (page 13)
Abb. 23

N Completely unroll the high-pressure hose

Working pressure and water flow rate can be set on the high-pressure pump for long-term adjustment in line with the cleaning job concerned.

Stihl RE163 — NOTICE diagram (page 13)
Abb. 24
Stihl RE163 — NOTICE diagram (page 13)
Abb. 25

N Press the safety latch (2) downward – the lever (1) is unlatched

N Squeeze the lever (1)

N Turn the master switch to I – now the machine is in standby mode

The motor stops when the lever is released.

N Turn the knob (1) clockwise to increase the working pressure and water flow

NOTICE

N Turn the knob (1) anticlockwise to reduce the working pressure and water flow

The machine must not be operated in standby mode for more than 5 minutes. If work is interrupted for more than 5 min., during breaks or if the machine is left unattended, switch off the machine at the master switch – see "Switching off the machine".

– The pressure in the high-pressure pump is indicated by a pressure gauge (2)

High-pressure hose · Pressure/quantity control · Standby mode

Page 14 of the Stihl RE163 user manual — 1607BA015 KN 670BA006 KN
Seite 14 · Zum Vergrößern klicken
Seite 14
Stihl RE163 — 1607BA015 KN 670BA006 KN diagram (page 14)
Abb. 26

Spray gun, spray lance, cleaning pin and additional accessories can be stored directly on the machine – see "Main Parts".

Stihl RE163 — 1607BA015 KN 670BA006 KN diagram (page 14)
Abb. 27

1607BA015 KN 670BA006 KN

N Hold the detergent tank by both handles and fold it out to the stop

The operating pressure can be infinitely adjusted at the nozzle.

N Unscrew the cap with intake hose from the detergent tank

Jet angle 15°, maximum effect at a distance of approx. 7 cm.

N Fill detergent tank with STIHL detergent diluted as specified

N Turn nozzle sleeve

N Seal the filling opening of the detergent tank with the cap

Nozzle with rotating jet for stubborn dirt on hard surfaces. Maximum effect at a distance of 10 cm.

N Press against the detergent tank until it engages in the housing

The spray attachment can also be used without nozzles at low pressure, e. g., for rinsing with a large flow of water.

Stihl RE163 — 1607BA015 KN 670BA006 KN diagram (page 14)
Abb. 28

Storage compartment for nozzles

Stihl RE163 — 1607BA015 KN 670BA006 KN diagram (page 14)
Abb. 29

N Turn sleeve as far as possible in the direction of the arrow (low-pressure operation)

Detergent can only be drawn into the machine in low-pressure operation.

N Open the flap – the rotary nozzle and fan jet nozzle can be stored in the holders

Show 4 more labels / short text on this page
Nozzles · Storing accessories · Fan-jet nozzle (1) · Rotary nozzle (2)
Page 15 of the Stihl RE163 user manual — 1607BA015 KN 670BA006 KN
Seite 15 · Zum Vergrößern klicken
Seite 15
Stihl RE163 — 1607BA015 KN 670BA006 KN diagram (page 15)
Abb. 30
Stihl RE163 — 1607BA015 KN 670BA006 KN diagram (page 15)
Abb. 31

Using detergent from a separate container

Stihl RE163 — 1607BA015 KN 670BA006 KN diagram (page 15)
Abb. 32

N Use the detergent metering knob to adjust the amount of detergent to be added

N Hold the detergent tank by both handles and fold it out past the stop and out of the housing

Detergent metering knob to the left: 0 % (min) Detergent metering knob to the right: 5 % (max)

N Unscrew the cap with intake hose from the detergent tank

N Fold out the detergent tank

N Unscrew the cap with intake hose from the detergent tank

The intake hose can be pushed into the high-pressure cleaner housing for storage.

N Screw the cap with intake hose onto a separate detergent container

N When applying detergent, start at the bottom and work upwards

The cap has a standard thread and fits all standard detergent containers.

Detergent must not be allowed to dry on the object to be cleaned

N Position the detergent tank in the mounts on the base of the housing

N Slide the intake hose as far as possible into the detergent container

If detergent is no longer to be added:

N Press against the detergent tank until it engages in the housing

N Set the detergent metering knob to 0 % (min)

Precisely calculating/setting the detergent concentration

N Let the high-pressure cleaner continue to run with the spray gun open until no more detergent comes out of the nozzle

For a few detergents, the concentration must be very precisely set. In this case, measure the water flow and detergent consumption.

If high-pressure hose extensions are connected, it is impossible to draw in detergent from the detergent tank.

N Set the nozzle sleeve to low- pressure operation – as described above

Fitting, removing detergent tank

N Set the detergent metering knob to "0 % (min)"

The detergent tank can be removed from the machine e. g. to empty or clean it.

N Hold the spray gun in a suitable empty receptacle (> 20 l) and actuate for exactly 1 minute

Mounting

Page 16 of the Stihl RE163 user manual — – A = 1
Seite 16 · Zum Vergrößern klicken
Seite 16

N Measure the quantity of water "Q" in the container

Ratio 1:1 = 50 % 1:2 = 33.3 % 1:3 = 25 % 1:5 = 16.6 % 1:10 = 9 %

Switching Off

N Fill 2 liters of detergent diluted as directed into a suitable container (with a scale of 0.1 l) – STIHL recommends the use of genuine STIHL detergents

Example:

N Hold the intake hose in the container

1607BA018 KN 650BA015 KN

Calculation ratio of 1:2

N Set the detergent metering knob to the desired concentration: 0 % (min) to 5 % (max)

– A = 1

– B = 2 N Turn the machine switch to 0 and turn off the water supply

N Hold the spray gun in a suitable empty receptacle (> 20 l) and actuate for exactly 1 minute

A x 100 = value in % (A + B)

N Actuate the spray gun until water only drips from the spray head (the machine is now depressurized)

1 x 100 = 33.3 % (1 + 2)

N Read the detergent consumption "QR" on the scale

Calculating the actual detergent concentration:

QR x V = concentration Q

– QR = amount of consumed detergent (in l/min)

– Q = Water without detergent (in l/min)

N Press the safety latch upward – the spray gun is locked to prevent inadvertent operation

– V = Predilution of detergent (in %)

If the actual concentration deviates from the desired concentration, reset knob and repeat measurement if necessary.

N Unplug the power plug from the socket

Calculating the predilution of the detergent in %

N Disconnect hose from the water supply and from the machine

If the predilution is not indicated as a percentage, it can be calculated using the following table:

N Release trigger

Page 17 of the Stihl RE163 user manual — Storing the Machine
Seite 17 · Zum Vergrößern klicken
Seite 17
Stihl RE163 — Storing the Machine diagram (page 17)
Abb. 33 · Storing the Machine

Storing the Machine

Stihl RE163 — Storing the Machine diagram (page 17)
Abb. 34 · Storing the Machine

Store the machine in a dry room where it is protected from frost.

If protection from frost cannot be guaranteed, draw glycol-based antifreeze – like that used in motor vehicles – into the pump:

N Insert the coupling in the mount and guide the flat hose (1) through the opening

N Insert water intake hose in container with antifreeze

N Rinse the connection latches of the spray lance and nozzle with water so that no deposits form

N Insert spray gun without spray lance in the same container

N Close the lock (2)

Stihl RE163 — Storing the Machine diagram (page 17)
Abb. 35 · Storing the Machine

N Roll the high-pressure hose and power cable up on the holders provided for this purpose – see "Main Parts"

N Switch on the machine with the spray gun open

N Actuate the spray gun until a uniform jet emerges

Versions with flat hose cassette*

N Keep leftover antifreeze in a sealed container

N Empty remaining water from the flat hose

N Lay out the flat hose so that it is straight and free from kinks or loops

N Roll up the flat hose

* Depending on the country, the flat hose cassette is included or is available as a special accessory

After use

Page 18 of the Stihl RE163 user manual — Maintenance and Care
Seite 18 · Zum Vergrößern klicken
Seite 18

Maintenance and Care

The following maintenance intervals apply in normal operating conditions. The spec- ified intervals must be shortened accordingly for longer daily working hours. If the machine is only used occasionally, the intervals can be extended accordingly.

at the end of work and/or

visual inspection (condition, leaks) X

Connectors on high-pressure hose

Plug-type coupling of the spray lance and the coupling sleeve of the spray gun clean X X

Water intake screen in the high-pressure inlet

Ventilation openings clean X

Show 17 more labels / short text on this page
before starting work · if damaged · as required · monthly · daily · Complete machine · clean X X · clean X X · grease X · clean X X · replace X · clean X · High pressure nozzle · replace X · check X · Machine supports · replace X
Page 19 of the Stihl RE163 user manual — NOTICE
Seite 19 · Zum Vergrößern klicken
Seite 19

Maintenance

NOTICE

Always remove the nozzle before cleaning it

The couplings on the spray gun for connecting the high-pressure hose and the spray lance must be greased as required.

Always unplug the power cord before servicing or cleaning the machine.

N Rinse the nozzle with water from the front

In order to ensure trouble free operation, we recommend carrying out the following steps whenever the machine is used:

Cleaning the water intake screen

N Rinse the water hose, high- pressure hose, spray lance and accessories with water before fitting them

The water intake screen must be cleaned once per month or more often if necessary.

Stihl RE163 — NOTICE diagram (page 19)
Abb. 36

N Remove all dust and sand from the couplings

Since the pump pressure increases if the nozzle is clogged, it must be cleaned immediately.

N Unscrew the hose connection

Stihl RE163 — NOTICE diagram (page 19)
Abb. 37

N Carefully remove the screen with pliers and rinse it with water

N Before refitting the strainer, ensure that it is undamaged and replace if necessary

Cleaning the ventilation openings

N Switch off the machine

The machine must be kept clean so that cooling air can flow freely through the openings in the machine.

N Actuate the spray gun until water only drips from the spray head – the machine is now depressurized

N Remove the nozzle

N Clean the nozzle with the cleaning pin

Greasing couplings · Cleaning the nozzle

Page 20 of the Stihl RE163 user manual — First use after long periods of storage
Seite 20 · Zum Vergrößern klicken
Seite 20

First use after long periods of storage

Minimize Wear and Avoid Damage

not carry out these maintenance tasks him- or herself, they should be delegated to a dealer.

During long periods of storage, mineral residue from the water may be deposited in the pump. This may cause the motor to start with difficulty or not at all.

Compliance with the specifications of this owner's manual will avoid excessive wear and damage to the machine.

STIHL recommends that maintenance and repair work be carried out only by authorized STIHL dealers. STIHL dealers receive regular training and are supplied with technical information.

The machine must be used, maintained and stored as carefully as described in this owner's manual.

N Connect the machine to the water supply and flush thoroughly with tap water, leave the power cord unplugged while doing so

If these tasks are not performed or are performed improperly, this may result in damage for which the user is responsible. Among other things, this includes:

The user is responsible for all damage caused by failure to comply with the safety, operating and maintenance instructions. This applies in particular for:

N Plug the power plug into the wall socket

– Damage to machine components due to delayed or insufficient performance of maintenance

N Switch on the machine with the spray gun open

– Product modifications not authorized by STIHL

– Corrosion damage and other consequential damages due to improper storage

– Use of accessories that are not approved for the machine, unsuitable or of inferior quality

– Damage to the machine as a result of using replacement parts of inferior quality

– Use of the machine in a manner not in keeping with the intended use

– Use of the machine in sporting events or competitions

Parts Subject to Wear and Tear

– Consequential damages due to continued use of a machine with defective components

Some parts of the machine are subject to normal wear and tear even when the machine is used in conformity with its intended use. These parts must be replaced in due time, depending on the nature and duration of use. These include, among others:

– Damage due to freezing

– Damage due to improper power supply voltage

– Damage due to poor water supply (e.g., cross-section of the intake hose too small)

All of the tasks listed under "Maintenance and Repairs" must be carried out periodically. If the user does

– High-pressure nozzles · – High-pressure hoses · Maintenance work

Page 21 of the Stihl RE163 user manual — First use after long periods of storage
Seite 21 · Zum Vergrößern klicken
Seite 21
Stihl RE163 — First use after long periods of storage diagram (page 21)
Abb. 38 · First use after long periods of storage
Page 22 of the Stihl RE163 user manual — RE 143, RE 143 PLUS
Seite 22 · Zum Vergrößern klicken
Seite 22

1 Spray gun 2 Lever 3 Safety catch 4 Spring button 5 High-pressure hose 6 Spray lance 7 Rotary nozzle 8 High-pressure nozzle, adjustable 9 Handle 10 Upper holder for spray attachment 11 High-pressure hose connection 12 Hose reel 13 Crank for hose reel 14 Button for height adjustment of handle 15 Machine switch 16 Detergent metering knob 17 Holders for power cord 18 Holder for special accessories, e.g., rotary washing brush 19 Storage compartment for nozzles 20 Pressure gauge 21 Lower holder for spray attachment 22 Water attachment 23 Pressure/quantity control knob 24 Carrying handle 25 Hose holder 26 Cleaning pin 27 Spray gun holder 28 Detergent tank 29 Flat hose cassette (included or available as a special accessory depending on the country) # Model plate

Specifications

RE 163, RE 163 PLUS

Power supply: 230 V / 1~ / 50 Hz 230 V - 240 V / 1~ / 50 Hz 5)

Power output3.3 kW 2.4 kW 5)

RE 143, RE 143 PLUS

Ampere rating14.3 A 10 A 5)
Power supply230 V / 1~ / 50 Hz 1), 4)

220 V / 1~ / 50 Hz 2)

Fuse, slow (char- acteristic "C" or "K"):

16 A

220 V / 1~ / 60 Hz 3)

Power output2.9 kW 1) 3)

10 A 5)

2.2 kW 2)

Protection class: I Type of protection: IP X5 5) 230 V - 240 V / 50 Hz version

2.8 kW 4)

Ampere rating12.6 A 1)

10 A 2)

13.2 A 3)

12.2 A 4)

13 A 1) 2) 4)

Fuse, slow (characteristic "C" or "K"):

RE 143, RE 143 PLUS

15 A 3)

Working pressure: 14 Mpa 1) (140 bar) 12 Mpa 2) (120 bar) 12.2 Mpa 3) (122 bar) 12.8 Mpa 4) (128 bar) Max. permissible pressure:

Protection class: I Type of protection: IP X5 1) 230 V / 50 Hz version 2) 220 V / 50 Hz version 3) 220 V / 60 Hz version 4) 230 V / 50 Hz version GB

15 Mpa (150 bar) Max. water feed pressure:

1 Mpa (10 bar) Max. water throughput: 610 l/h 1) 4)

Show 4 more labels / short text on this page
Electrical Specifications · Hydraulic specifications · 520 l/h 2) · 700 l/h 3)
Page 23 of the Stihl RE163 user manual — RE 143 PLUS
Seite 23 · Zum Vergrößern klicken
Seite 23

Water throughput, as per EN 60335-2-79:

Water throughput, as per EN 60335-2-79:

570 l/h 470 l/h 5)

RE 163

Device24 kg Ready for operation: 26.4 kg

Max. suction lift: 0.5 m Max. water feed temperature With pressurized water supply: 60 °C Suction operation: 20 °C Max. kickback force: 27.4 N 20.2 N 5)

RE 163 PLUS

Max. suction lift: 0.5 m Max. water feed temperature With pressurized water supply: 60 °C Suction operation: 20 °C Max. kickback force: 25.1 N 1)

Device25 kg Ready for operation: 27.2 kg
5. 230 V - 240 V / 50 Hz version

20.2 N 2)

RE 143: 9 m, DN 06, steel braided RE 143 PLUS: 12 m, DN 06, steel braided RE 163: 9 m, DN 06, steel braided RE 163 PLUS: 12 m, DN 06, steel braided

28.6 N 3)

25.3 N 4)

1. 230 V / 50 Hz version 2) 220 V / 50 Hz version 3) 220 V / 60 Hz version 4) 230 V / 50 Hz version GB

RE 143, RE 163

Length approx.: 386 mm Width approx.: 377 mm Height approx.: 711 mm

RE 163, RE 163 PLUS

RE 143 PLUS, RE 163 PLUS

Working pressure15 Mpa (150 bar) 12 Mpa 5) (120 bar) Max. permissible pressure:

Length approx.: 386 mm Width approx.: 377 mm Height approx.: 787 mm

12 m, textile braided

16 Mpa (160 bar) Max. water feed pressure:

Sound and vibration levels

1 Mpa (10 bar) Max. water throughput: 650 l/h 520 l/h 5)

Sound pressure level LpA to EN 60335-2-79 Appendix ZAA

RE 143

RE 143 71.7 dB(A) 1)

Device24 kg Ready for operation: 26.4 kg

74.6 dB(A) 2)

75.6 dB(A) 3)

RE 143 PLUS

RE 143 PLUS 77.4 dB(A) 1)

77.9 dB(A) 4)

Device25 kg Ready for operation: 27.2 kg

RE 163 73.5 dB(A) 1)

74.6 dB(A) 5)

RE 163 PLUS 79.7 dB(A) 1)

Show 8 more labels / short text on this page
540 l/h 1) · 470 l/h 2) · 660 l/h 3) · 570 l/h 4) · High-pressure hose · Dimensions · Flat hose · Weight
Page 24 of the Stihl RE163 user manual — REACH
Seite 24 · Zum Vergrößern klicken
Seite 24

Sound power level LwA to EN 60335-2-79 Appendix ZAA

Special Accessories

Pipe cleaning set, 15 m

Stihl RE163 — Special Accessories diagram (page 24)
Abb. 39 · Special Accessories

RE 143 84.8 dB(A) 1)

87.6 dB(A) 2)

88.7 dB(A) 3)

RE 143 PLUS 90.5 dB(A) 1)

RE 163 86.6 dB(A) 1)

Stihl RE163 — Special Accessories diagram (page 24)
Abb. 40 · Special Accessories

87.6 dB(A) 5)

RE 163 PLUS 92.8 dB(A) 1)

There is a mark on the cleaning hose underneath the nozzle (see arrow).

1. 230 V / 50 Hz version 2) 220 V / 50 Hz version 3) 220 V / 60 Hz version 4) 230 V / 50 Hz version GB 5) 230 V - 240 V / 50 Hz version

N Push the hose into the pipe to be cleaned until this mark is reached – then switch on the machine

When this mark appears as the hose is pulled out of the pipe:

As a rule, only one spray lance extension (1) may be used between spray gun and standard spray lance (2).

Vibration level ahv at the handle according to ISO 5349

N Switch off the machine

With fan nozzle < 2.5 m/s2

N Actuate the spray gun until the machine has been depressurized

RA 101

For the sound pressure level and the sound power level, the K-factor in accordance with Directive 2006/42/EC = 1.5 dB(A); for the vibration level, the K-factor in accordance with Directive 2006/42/EC = 2.0 m/s2.

Use the RA 101 either directly or together with the included spray lance extension on the spray gun. Do not install any additional spray lance extension.

N Pull the hose out of the pipe completely

The hose must never be pulled out of the pipe when the machine is switched on.

Wet sand jet-stream appliance

REACH

– 7 m, steel braided

Use the wet sand jet-stream appliance either directly or together with a spray lance extension on the spray gun. Do not install any additional spray lance extension.

– 10 m, steel braided

REACH is an EC regulation and stands for the Registration, Evaluation, Authorisation and Restriction of Chemical substances.

– 20 m, steel braided

Always connect only one high-pressure hose extension between machine and high-pressure hose.

For information on compliance with the REACH regulation (EC) No. 1907/2006 see www.stihl.com/reach

Flat textile hose with cassette

Low-pressure hose for connecting the high-pressure cleaner to the water supply. The cassette permits reeling in

Spray lance extension · 91 dB(A) 4) · High-pressure hose extensions

Page 25 of the Stihl RE163 user manual — Special Accessories
Seite 25 · Zum Vergrößern klicken
Seite 25

and unreeling of the flat textile hose as well as storage in a minimum of space right on the machine

For filtering water from the water main, as well as for use in pressureless suction operation.

Use the rotating wash brush either directly or together with a spray lance extension on the spray gun. Do not install any additional spray lance extension.

Prevents the water from flowing back from the high-pressure cleaner into the drinking water main.

Use the angled spray lance either directly or together with a spray lance extension on the spray gun. Do not install any additional spray lance extension.

– Detergents and care products for various spheres of application

The nozzle can be cleaned with the aid of the cleaning pin supplied.

Ask your STIHL servicing dealer for current information about this and other special accessories.

Angled spay lance, long

Stihl RE163 — Special Accessories diagram (page 25)
Abb. 41 · Special Accessories

Use the long, angled spray lance only directly on the spray gun. Do not install a spray lance extension.

Do not aim around blind corners behind which people may be concealed. The nozzle can be cleaned with the aid of the cleaning pin supplied.

Show 8 more labels / short text on this page
Water filter · Rotating washing brush · Backflow preventer · Angled spray lance · Other special accessories · – Wash brush · – Cleaning kit · – Suction set
Page 26 of the Stihl RE163 user manual — Troubleshooting
Seite 26 · Zum Vergrößern klicken
Seite 26

Troubleshooting

Before working on the machine, unplug the power cord, turn off the water supply and actuate the spray gun until the pressure has been relieved. Fault Cause Remedy Motor does not run when switched on (hums when switched on)

Mains voltage is too low or improper Check electrical connection

Check plug, cable and switch Extension cord with wrong cross-section Use an extension cord with a sufficient cross-section, see "Connecting the machine to the power supply" Extension cord is too long Connect the machine without an exten- sion cord or with a shorter one Mains circuit-breaker has been tripped Switch off the machine, actuate the spray gun until water only drips out of the head, engage the safety catch, reset the mains circuit-breaker Spray gun not actuated Actuate spray gun when switching on the machine Motor constantly switches on and off High-pressure pump or spray attachment is leaky

Have the machine checked by a servicing dealer 1)

Engine stops Machine switches off because the motor is overheating

Check whether the supply voltage and machine voltage match; let the motor cool down for at least 5 minutes Weak, ragged, unclean jet Nozzle fouled Clean nozzle, see "Maintenance"

Page 27 of the Stihl RE163 user manual — Troubleshooting
Seite 27 · Zum Vergrößern klicken
Seite 27

Before working on the machine, unplug the power cord, turn off the water supply and actuate the spray gun until the pressure has been relieved. Fault Cause Remedy

Pressure fluctuates or drops Shortage of water Open water tap completely

Comply with permissible suction lift (suc- tion mode only) High-pressure nozzle in spray head is dirty Clean high-pressure nozzle; see "Maintenance" Water intake strainer in pump inflow clogged Clean water intake strainer; see "Maintenance" High-pressure pump is leaky, valves are defective

Have the machine checked by a servicing dealer 1)

Nozzle clogged Clean nozzle No supply of detergents Detergent tank is empty Fill detergent tank Detergent intake is clogged Eliminate clog Venturi nozzle is worn Have the machine checked by a servicing dealer 1) STIHL recommends STIHL servicing dealers

Page 28 of the Stihl RE163 user manual — Maintenance and Repairs Disposal
Seite 28 · Zum Vergrößern klicken
Seite 28

Maintenance and Repairs Disposal

EC Declaration of Conformity

Users of this machine may only carry out the maintenance and service work described in this user manual. All other repairs must be carried out by a servicing dealer.

Observe all country-specific waste disposal rules and regulations.

ANDREAS STIHL AG & Co. KG Badstr. 115 D-71336 Waiblingen

STIHL recommends that you have servicing and repair work carried out exclusively by an authorized STIHL servicing dealer. STIHL dealers are regularly given the opportunity to attend training courses and are supplied with the necessary technical information.

ModelHigh-pressure cleaners Make: STIHL Type: RE 143, RE 143 PLUS Serial identification number:

STIHL products must not be thrown in the garbage can. Take the product, accessories and packaging to an approved disposal site for environment- friendly recycling.

When repairing the machine, only use replacement parts which have been approved by STIHL for this power tool or are technically identical. Only use high- quality replacement parts in order to avoid the risk of accidents and damage to the machine.

TypeRE 163, RE 163 PLUS Serial identification number:

Contact your STIHL servicing dealer for the latest information on waste disposal.

conforms to the specifications of Directives 2011/65/EU, 2006/42/EC, 2004/108/EC and 2000/14/EC and has been developed and built in compliance with the following standards:

STIHL recommends the use of original STIHL replacement parts.

Original STIHL parts can be identified by the STIHL part number, the { logo and the STIHL parts symbol K (the symbol may appear alone on small parts).

EN ISO 12100-1, EN ISO 12100-2, EN 55014-1, EN 55014-2, EN 60335-1, EN 60335-2-79, EN 61000-3-2, EN 61000-3-3

The measured and guaranteed equivalent sound power level has been determined in accordance with Directive 2000/14/EC, Annex V, and standard ISO 3744.

hereby confirms that

Page 29 of the Stihl RE163 user manual — Maintenance and Repairs Disposal
Seite 29 · Zum Vergrößern klicken
Seite 29

Measured sound power level

Waiblingen, 01.08.2012

Stihl RE163 — Maintenance and Repairs Disposal diagram (page 29)
Abb. 42 · Maintenance and Repairs Disposal

RE 143 84.8 dB(A) 1)

ANDREAS STIHL AG & Co. KG

87.6 dB(A) 2)

p p.

88.7 dB(A) 3)

RE 143 PLUS 90.5 dB(A) 1)

RE 163 86.6 dB(A) 1)

87.6 dB(A) 5)

RE 163 PLUS 92.8 dB(A) 1)

Head of Product Group Management

Guaranteed sound power level

RE 143 86 dB(A) 1)

RE 143 PLUS 92 dB(A) RE 163 88 dB(A) 1)

RE 163 PLUS 94 dB(A) 1)

1. 230 V / 50 Hz version 2) 220 V / 50 Hz version 3) 220 V / 60 Hz version 4) 230 V / 50 Hz version GB 5) 230 V - 240 V / 50 Hz version

All STIHL products comply with the highest quality standards.

An independent organization has certified that all products manufactured by STIHL meet the strict requirements of the ISO 9001 standard for quality management systems in terms of product development, materials purchasing, production, assembly, documentation and customer service.

The technical documentation has been retained by:

ANDREAS STIHL AG & Co. KG Product approval

The year of construction of the machine is shown on the CE plate on the machine.

Show 5 more labels / short text on this page
91 dB(A) 4) · Thomas Elsner · 89 dB(A) 2) · 90 dB(A) 3) · 89 dB(A) 5)
Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Reparatur

Fehlerbehebung

Häufige Probleme, wahrscheinliche Ursachen und Lösungen.

ProblemMögliche UrsacheAbhilfe
Motor does not run when switched on (hums when switched on)Mains voltage is too low or improperCheck electrical connection Check plug, cable and switch p.26
Motor does not run when switched on (hums when switched on)Extension cord with wrong cross-sectionUse an extension cord with a sufficient cross-section, see "Connecting the machine to the power supply" p.26
Motor does not run when switched on (hums when switched on)Extension cord is too longConnect the machine without an exten- sion cord or with a shorter one p.26
Motor does not run when switched on (hums when switched on)Mains circuit-breaker has been trippedSwitch off the machine, actuate the spray gun until water only drips out of the head, engage the safety catch, reset the mains circuit-breaker p.26
Motor does not run when switched on (hums when switched on)Spray gun not actuatedActuate spray gun when switching on the machine p.26
Motor constantly switches on and offHigh-pressure pump or spray attachment is leakyHave the machine checked by a servicing dealer 1) p.26
Engine stopsMachine switches off because the motor is overheatingCheck whether the supply voltage and machine voltage match; let the motor cool down for at least 5 minutes p.26
Weak, ragged, unclean jetNozzle fouledClean nozzle, see "Maintenance" p.26

Frage zu Stihl RE163 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Stihl RE163

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Stihl RE163 PDF-Anleitung

252 Seiten·7.9 MB·Hochdruckreiniger·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…