DE
Siemens logo
Offizielle Bedienungsanleitung

Siemens LC258BA90

156 Seiten·3.7 MB·Dunstabzugshaube·PDF·ENJA
Siemens LC258BA90
Inhaltsverzeichnis 68 Abschnitte General information · I NFORMATION ON PROTECTION OF THE ENVIRONMENT · B EFORE USING THE APPLIANCE FOR THE FIRST TIME · Disposal of transport packaging · … AnzeigenAusblenden
General informationp.1I NFORMATION ON PROTECTION OF THE ENVIRONMENTp.1B EFORE USING THE APPLIANCE FOR THE FIRST TIMEp.1Disposal of transport packagingp.1Disposal of the old appliancep.1Faultsp.1E-no. FDp.1 Safety instructionsp.2Intended usep.2Technical safetyp.2Special information for gas cookersp.3Proper usep.4Correct installationp.4Operating modesp.5Exhaust-air modep.5Appliance dimensions Exhaust airp.5Circulating-air modep.5Appliance dimensions Circulating airp.5w 1 2 3 4 ! 0 8 u tp.6Rotary selectorp.6Displayp.7Status linep.7Settings areasp.7Direction of rotation displayp.7Standard settingsp.7NOTEp.7Change languagep.8Set timep.8Duration of acoustic signalp.8Button soundp.8Display brightnessp.8Contrastp.8Clock displayp.8Timerp.9Select run-on timep.9Select intermittent timep.9Exhaust air / circulating airp.9Brand logo displayp.9Confirmation of standard settingp.9Operationp.10Switch on the fan and select the fan settingsp.10Switch off the fanp.10Intensive setting (fan setting 4)p.10Fan run-onp.10Lightp.11Set timerp.11Intermittentp.11Saturation displays Grease filtersp.12Cleaning and carep.13L OOKING AFTER THE APPLIANCEp.13Metal-mesh grease filtersp.13Appliance surfacesp.13Removing and installing the grease filtersp.14Changing the activated carbon filterp.14Changing the bulbsp.15Installation instructionsp.16Connecting pipesp.16Connection of 150 mm ø exhaust air pipe (recommended size)p.16Connection of 120 mm ø exhaust air pipep.16E LECTRICAL CONNECTIONp.17If a permanent connection is requiredp.17Electrical specificationsp.17Installationp.18Preparing the wall RISK OF INJURY,p.18Max. weight in kg: 40p.18 p.19Removing the safety capsp.19Tabel de matièresp.21
Page 1 of the Siemens LC258BA90 user manual — E-no. FD
Seite 1 · Zum Vergrößern klicken
Seite 1

General information

I NFORMATION ON PROTECTION OF THE ENVIRONMENT

B EFORE USING THE APPLIANCE FOR THE FIRST TIME

Disposal of transport packaging

Your new appliance was sent to you in protective packaging. All utilised materials are environmentally safe and recyclable. Please help us by disposing of the packaging in an environmentally friendly manner.

Before switching on your new appliance, plea- se read the operating instructions carefully. They contain important information on safety and how to use and look after the appliance.

Packaging parts can be hazardous for children. Therefore keep them outside the reach of children.

Keep the operating and instructions in a safe place and pass them on to any subsequent owner of the appliance.

Disposal of the old appliance

Old appliances are not worthless rubbish. Valuable raw materials can be reclaimed by recycling old appliances.

Faults

This appliance is identified according to the European Directive 2002/96/EC on waste electrical and electronic equipment – WEEE). The directive specifies the framework for an EU-wide valid return and re-use of old appliances.

)

Please contact customer service regarding any queries or faults.

(See list of customer service centres).

When calling, please quote:

E-no. FD

Before disposing of your old appliance, render it unusable.

The numbers can be found on the rating plate, after removal of the grease filter, inside the extractor hood. Enter the numbered in the above fields.

Never treat your old appliance as non- recyclable waste!

Please ask your dealer or inquire at your local authority about current means of disposal.

Ensure that the old appliance is kept childproof until it is disposed of.

Page 2 of the Siemens LC258BA90 user manual — Technical safety
Seite 2 · Zum Vergrößern klicken
Seite 2

Safety instructions

Intended use

If the appliance is improperly installed, serviced or repaired, the user may be placed in considerable danger for which the manufacturer is not liable.

This extractor hood complies with the stipulated safety regulations. Improper use may result in injury or damage.

Changes to the electrical or mechanical installation are dangerous and must not be undertaken! They may also cause the extractor hood to malfunction.

The extractor hood may be used in the household only. The manufacturer is not liable for damage which is caused by improper use or incorrect operation.

Simultaneous operation of the extractor hood with a heating appliance which is dependent on ambient air

The manufacturer cannot be made responsible for damage which can be attributed to non-observance of the safety instructions. RISK OF INJURY Do not allow children to play with the extractor hood! Adults and children must never operate the appliance unsupervised – if they are not physically or mentally

Heating appliances which are dependent on ambient air, e.g. gas, oil, wood, or solid-fuel heaters, instantaneous water heaters, hot water boilers, hobs or ovens, and which draw combustion air out of the installation room and whose exhaust gases are conveyed to the exterior by a flue. RISK OF POISONING If the extractor hood is operated at the same time as a heating appliance which is dependent on ambient air, there is a risk of poisoning due to combustion gases being drawn back in.

capable of doing so, – or if they do not have the knowledge and

experience to operate the appliance correctly and safely.

Technical safety

The extractor hood left the factory in perfect condition. Nevertheless check the appliance for visible damage before installation. If it is damaged, do not switch it on!

If the power cord of the extractor hood is damaged, it must be replaced by the manufacturer, his customer service or a similarly qualified person to prevent hazardous situations.

Only a qualified technician may install (including electrical connection), service or repair the extractor hood. Always isolate the extractor hood by pulling out the mains plug or switching off the fuse!

Page 3 of the Siemens LC258BA90 user manual — Special information for gas cookers
Seite 3 · Zum Vergrößern klicken
Seite 3

Safety instructions

Safe operation is possible provided the low pressure in the installation room of the heating appliance does not exceed 4Pa (0.04mbar). This can be achieved if the combustion air can flow through non-closable openings, e.g. in doors, windows, in conjunction with air intake/exhaust air wall boxes or by other technical measures.

Special information for gas cookers

When installing the extractor hood above gas hobs, observe the appropriate national statutory regulations (e.g. in Germany: Technische Regeln Gasinstallation TRGI).

Observe the currently valid installation regulations and instructions of the gas appliance manufacturer.

Siemens LC258BA90 — Special information for gas cookers diagram (page 3)
Abb. 1 · Special information for gas cookers
Siemens LC258BA90 — Special information for gas cookers diagram (page 3)
Abb. 2 · Special information for gas cookers

During installation, ensure that only one side of the extractor hood is situated directly next to a high-sided unit or a wall. Otherwise, there is a risk of heat build-up. The gap between the extractor hood and the wall or high-sided unit must be at least 50 mm. RISK OF BURNS Do not operate more than 2 gas cooking areas simultaneously over a period of max. 15 minutes at maximum thermal load. Due to the effect of the heat there is a risk of burns if the surfaces of the housing are touched!

Siemens LC258BA90 — Special information for gas cookers diagram (page 3)
Abb. 3 · Special information for gas cookers

Adequate intake air must therefore always be provided.

An intake/exhaust air wall box alone does not ensure compliance with the limit value.

Note that one large burner of more than 5 kW (Wok) is equivalent to the power of 2 gas burners.

The extractor hood may be damaged by the intense heat.

If the extractor hood is used in circulating air mode only, it can be operated without any restrictions.

Never operate a gas cooking area without a cooking utensil on it. Regulate the flame in such a way that it does not project over the cooking utensil.

Page 4 of the Siemens LC258BA90 user manual — Proper use
Seite 4 · Zum Vergrößern klicken
Seite 4

Safety instructions

Proper use

Correct installation

Clean the extractor hood thoroughly before using for the first time.

Check the manufacturer’s specifications for the cooker to determine whether an extractor hood can be operated over it.

Before cleaning and servicing the extractor hood, isolate it from the power supply by pulling out the mains plug or switching off the fuse.

If the manufacturer of the cooker has not specified any significant safety distances, the following minimum distances apply – 550 mm between electric hob and the

Bulbs (especially halogen bulbs) become very hot during operation. Even some time after the appliance has been switched off, there is still a risk of burns!

lower edge of the extractor hood – 650 mm between gas hob (upper edge of

pan support) and the lower edge of the extractor hood, (siehe Abbildungen auf Seite 2).

Before changing bulbs, isolate the extractor hood from the power supply and leave the bulbs to cool down!

If various cookers are used, the greatest indicated distance applies.

Do not operate the extractor hood without bulbs inserted.

The width of the extractor hood must correspond to the width of the cooking area.

Always switch on the extractor hood if a hotplate is being used. If the extractor hood is not switched on, condensation may form. As a result, the appliance may corrode.

The extractor hood must not be installed over a solid fuel heating appliance which may be a fire risk (e.g. flying sparks) unless the heating appliance has a closed, non- detachable cover and the country-specific regulations are observed. This restriction does not apply to gas cookers and gas hobs.

Do not place any objects on the extractor hood.

Siemens LC258BA90 — Proper use diagram (page 4)
Abb. 4 · Proper use

To avoid damaging the hob, cover it when installing the extractor hood.

RISK OF FIRE Do not flambé under the extractor hood or work with a naked flame. When switched on, the extractor hood draws flames into the filter. There is a risk of fire due to deposits on the grease filter! Do not leave pans, frying pans or deep-fat fryers unattended if you are cooking food with oils or fats, e.g. chips. Overheated oils or fats can easily ignite!

A risk of fire can be prevented by cleaning the grease filters regularly and changing the activated-carbon filter in good time.

Never operate the extractor hood without grease filters.

Page 5 of the Siemens LC258BA90 user manual — Circulating-air mode
Seite 5 · Zum Vergrößern klicken
Seite 5

Operating modes

The extractor hood can be used in exhaust air and circulating air mode.

Exhaust-air mode

Appliance dimensions Exhaust air

Siemens LC258BA90 — Exhaust-air mode diagram (page 5)
Abb. 5 · Exhaust-air mode
Siemens LC258BA90 — Exhaust-air mode diagram (page 5)
Abb. 6 · Exhaust-air mode
Siemens LC258BA90 — Exhaust-air mode diagram (page 5)
Abb. 7 · Exhaust-air mode

The air which is drawn in is cleaned by the grease filters and conveyed to the exterior by a pipe system.

Circulating-air mode

Appliance dimensions Circulating air

Siemens LC258BA90 — Circulating-air mode diagram (page 5)
Abb. 8 · Circulating-air mode
Siemens LC258BA90 — Circulating-air mode diagram (page 5)
Abb. 9 · Circulating-air mode
Siemens LC258BA90 — Circulating-air mode diagram (page 5)
Abb. 10 · Circulating-air mode

The air which is drawn in is cleaned by the grease filters and an activated carbon filter and conveyed back into the kitchen. An activated carbon filter must be installed to bind odours in circulating-air mode (see ”Removing and installing the grease filters”). The complete installation set as well as the replacement filters are available from specialist outlets, customer service or the Online Shop. The accessory number can be found at the end of the operating instructions.

Page 6 of the Siemens LC258BA90 user manual — Rotary selector
Seite 6 · Zum Vergrößern klicken
Seite 6
Siemens LC258BA90 — w 1 2 3 4 ! 0 8 u t diagram (page 6)
Abb. 11 · w 1 2 3 4 ! 0 8 u t

Below is an overview of the control panel of your extractor hood. Here you will receive a brief explanation on the individual controls.

w 1 2 3 4 ! 0 8 u t

Switch extractor hood on and off Switch on fan setting 1 Switch on fan setting 2 Switch on fan setting 3 Switch on fan setting 4 (Intensive setting) Set fan run-on, run-on time Light on / off Set timer Switch on intermittent ventilation Press briefly = request information Hold down = open or close Standard settings menu

Rotary selector

You can use the rotary selector to change suggested and set values. The rotary selector is retractable. To engage and disengage, depress the rotary selector.

Page 7 of the Siemens LC258BA90 user manual — NOTE
Seite 7 · Zum Vergrößern klicken
Seite 7

Display

The display is divided into different areas:

Status line Direction of rotation display

Siemens LC258BA90 — Display diagram (page 7)
Abb. 12 · Display

Status line

The Status line indicates the time, the selected fan mode and the information text.

Settings areas

The settings areas indicate suggested values which you can change. The active settings area is lit.

By pressing the relevant Function button, you can change from one settings area to the next.

Direction of rotation display

b = Turn rotary selector to the right c = Turn rotary selector to the left

If both direction arrows dare displayed, you can turn the rotary selector in either direction.

Standard settings

Before switching on the appliance, always follow the instructions and warnings in the chapter entitled ”Safety instructions”.

NOTE

If required, set the language for the text display. German has been preset.

The changes to the standard settings will not take effect until the extractor hood has been switched off.

Each change can be saved by holding down the t button or deleted by pressing the w button.

Page 8 of the Siemens LC258BA90 user manual — NOTE
Seite 8 · Zum Vergrößern klicken
Seite 8

Standard settings

Change language

1. Hold down the t button for approx. 3 seconds. The ”Standard settings” menu is opened. The ”Language” settings area is lit.
Siemens LC258BA90 — Standard settings diagram (page 8)
Abb. 13 · Standard settings

2. Set the language with the rotary selector.
3. Press the t button to switch to the next settings area.

Set time

The ”Set time” settings area is lit.

1. Set the time with the rotary selector.
2. Press the t button to switch to the next settings area.

Duration of acoustic signal

The “Acoustic signal duration” settings area is lit.

1. Using the rotary selector, adjust the acoustic signal duration (short, medium or long).
2. Press the t button to switch to the next settings area.

Button sound

The ”Button sound” settings area is lit.

1. Switch the button sound on or off with the rotary selector.
2. Press the t button to switch to the next settings area.

Display brightness

The “Display brightness” settings area is lit.

1. Using the rotary selector, adjust the brightness (night, medium, day).
2. Press the t button to switch to the next settings area.

Contrast

The “Contrast” settings area is lit.

1. Using the rotary selector, adjust the contrast.
2. Press the t button to switch to the next settings area.

Clock display

The ”Clock display” settings area is lit.

1. Switch the clock display on or off with the rotary selector.

NOTE

Please note that when the clock display is switched off, there is no display either when the extractor hood is in an idle state or in operating mode.

2. Press the t button to switch to the next settings area.
Page 9 of the Siemens LC258BA90 user manual — Confirmation of standard setting
Seite 9 · Zum Vergrößern klicken
Seite 9

Standard settings

Timer

The ”Timer” settings area is lit.

1. Using the rotary selector, set the preferred time (5, 10 or 15 minutes).
2. Press the t button to switch to the next settings area.

Select run-on time

The ”Run-on time” settings area is lit.

1. Set the preferred time with the rotary selector.
2. Press the t button to switch to the next settings area.

Select intermittent time

The ”Intermittent time” settings area is lit.

1. Set the intermittent time with the rotary selector.
2. Press the t button to switch to the next settings area.

Exhaust air / circulating air

The extractor hood can be used in exhaust air and circulating air mode.

1. Select the ”Exhaust air/Circulating air” settings area.
2. Set the operating mode with the rotary selector.
Siemens LC258BA90 — Exhaust air / circulating air diagram (page 9)
Abb. 14 · Exhaust air / circulating air

34 , 34 ,

34 , 0 ,

3. Press the t button to switch to the next settings area.

Brand logo display

The brand logo can be switched on or off.

1. Select the “Display/brand logo” settings area.
2. Using the rotary selector, adjust the display.

Press the t button for approx. 3 seconds. The changes to the standard settings are accepted.

Confirmation of standard setting

Page 10 of the Siemens LC258BA90 user manual — Fan run-on
Seite 10 · Zum Vergrößern klicken
Seite 10

Operation

Switch on the fan and select the fan settings

It is recommended to switch on the blower when you start cooking and not to switch it off again until several minutes after you have finished cooking. In this way the kitchen fumes are removed most effectively.

Press the w button. The appliance automatically switches to fan setting 2.

Siemens LC258BA90 — Operation diagram (page 10)
Abb. 15 · Operation

Select the required fan setting by pressing the corresponding Function button (1-3).

Press the w button.

Switch off the fan

Intensive setting (fan setting 4)

The Intensive setting generates maximum performance. It can be used if thick fumes or strong odours occur temporarily.

Press Function button 4.

If the Intensive setting is not switched off by hand, the fan automatically switches back to setting 2 after 10 minutes.

Press the + button.

Fan run-on

Siemens LC258BA90 — Fan run-on diagram (page 10)
Abb. 16 · Fan run-on

01, ( % 2

The fan runs at the selected setting for the set time. Then the fan switches off automatically.

Page 11 of the Siemens LC258BA90 user manual — Intermittent
Seite 11 · Zum Vergrößern klicken
Seite 11

Operation

Light

The light can be switched on and off independently of the fan.

Siemens LC258BA90 — Operation diagram (page 11)
Abb. 17 · Operation
1. Press the 0 button. The ”Light” area is selected automatically.
2. Set the required luminosity with the rotary selector.

The selected luminosity is indicated on the display.

Set timer

The timer runs independently of the extractor hood.

1. Press the W button. The preset running time of the timer is displayed.
Siemens LC258BA90 — Set timer diagram (page 11)
Abb. 18 · Set timer
2. The running time of the timer can be changed with the rotary selector.
3. The time runs automatically.

The elapsing time is indicated on the display.

When the time has elapsed, a signal sounds. Press the W button to end the signal early.

Intermittent

Intermittent ventilation can be used to ventilate the kitchen hourly for the preset time.

1. Select a fan setting (except fan setting 4).
Siemens LC258BA90 — Intermittent diagram (page 11)
Abb. 19 · Intermittent

5 , " ( % 2

2. Press the u button. The ”Intermittent” area is selected automatically.
Page 12 of the Siemens LC258BA90 user manual — Saturation displays Grease filters
Seite 12 · Zum Vergrößern klicken
Seite 12

Operation

Intermittent ventilation starts automatically. The display switches back to idle state after the set time has elapsed.

The saturation of the grease filters can be queried via the Information button. To do this, the extractor hood must be switched on.

Press thetbutton.

Siemens LC258BA90 — Operation diagram (page 12)
Abb. 20 · Operation

Saturation displays Grease filters

NOTE

The saturation display of the grease filters can be reset even before 100 % is reached.

1. Press the t button again. The settings area is lit.
2. Using the rotary selector, set the saturation display to 0 %.

If the t button is lit and a signal sounds when the extractor hood has been switched off, the grease filters are 100% saturated.

1. Clean the grease filters or replace the activated carbon filter.
Siemens LC258BA90 — Saturation displays Grease filters diagram (page 12)
Abb. 21 · Saturation displays Grease filters

!

& ( ( . 6 . 8 7 , . ,

2. Set the indicator to “yes”.
3. Acknowledge the input by pressing the t button.
Page 13 of the Siemens LC258BA90 user manual — Appliance surfaces
Seite 13 · Zum Vergrößern klicken
Seite 13

Cleaning and care

L OOKING AFTER THE APPLIANCE

Metal-mesh grease filters

Suitable cleaning agents and care products for your appliance can be purchased via the Hotline or from the Online Shop (see cover page).

The metal-mesh grease filters absorb the grease particles from the kitchen fumes.

The filter mats consist of fire-proof metal. RISK OF FIRE As the filters become more saturated with greasy residue, the flammability increases. The function of the extractor hood may also be impaired.

Appliance surfaces

The appliance surfaces and controls are scratch-sensitive. Therefore observe the following cleaning instructions: – Avoid cleaning the extractor hood with dry

The risk of fire is prevented by cleaning the metal-mesh grease filters in good time.

When cleaning the grease filters, also remove grease deposits from the accessible parts of the housing with a damp cloth.

cloths, abrasive sponges, scouring agents, cleaning agents containing sand, soda, acid, chlorine or any other aggressive substances. – Clean the appliance surfaces and controls

Cleaning the metal-mesh grease filters ... Under normal operation (daily 1 to 2 hours), the metal-mesh grease filters must be cleaned 1x month.

with a soft, damp cloth, washing-up liquid or a mild window cleaner only. – Do not scrape off dried dirt, but moisten with

a damp cloth. – Clean carefully in the area of the controls to

... in the dishwasher The metal-mesh grease filters can be cleaned in the dishwasher. Slight discolouration may occur but this will not affect the function of the grease filters. The filters must be placed loosely in the dishwasher. They must not be wedged in.

avoid liquid from getting into the electronics.

... by hand When cleaning by hand, soak the grease filters in a hot detergent solution, brush off the dirt, rinse thoroughly and leave to dry. Do not use any aggressive, acidic or alkaline cleaning agents.

If dirt is particularly stubborn, we recommend using a special grease solvent spray. This can be ordered via the Online Shop.

Page 14 of the Siemens LC258BA90 user manual — Changing the activated carbon filter
Seite 14 · Zum Vergrößern klicken
Seite 14

Removing and installing the grease filters

Before removing and installing the grease filters, always follow the instructions and warnings in the chapter entitled ”Safety instructions”!

Activated carbon filters bind the odours in circulating-air mode.

Removing and installing the metal-mesh grease filters 1. Open the lock and fold down the grease filters. In doing so, hold the underside of the grease filters with your other hand.

Installing and removing the activated carbon filters 1. Remove the grease filters (see Removing and installing the metal-mesh grease filters).

Siemens LC258BA90 — Removing and installing the grease filters diagram (page 14)
Abb. 22 · Removing and installing the grease filters
Siemens LC258BA90 — Removing and installing the grease filters diagram (page 14)
Abb. 23 · Removing and installing the grease filters
2. Insert the activated carbon filter. 3. Lock the catch. 4. Reinsert the grease filters (see Removing and installing the metal-mesh grease filters).

Changing the activated carbon filter

Under normal operation (daily 1 to 2 hours) the activated carbon filters must be replaced approximately 2x year. The activated carbon filter is available from specialist outlets, customer service or the Online Shop (see Optional accessories). Use original filters only.

Siemens LC258BA90 — Changing the activated carbon filter diagram (page 14)
Abb. 24 · Changing the activated carbon filter

Activated carbon filters do not contain any pollutants. They can be disposed of in the household refuse.

(for appliances with edge extraction)

2. Clean the grease filters. 3. Reinsert the cleaned grease filters.
Page 15 of the Siemens LC258BA90 user manual — Changing the bulbs
Seite 15 · Zum Vergrößern klicken
Seite 15

Changing the bulbs

Before changing the bulbs, always follow the instructions and warnings in the chapter entitled ”Safety instructions”!

Changing the filament bulbs 1. Lift the bulb cover slightly. 2. Push the bulb cover towards the middle of the appliance.

Siemens LC258BA90 — Changing the bulbs diagram (page 15)
Abb. 25 · Changing the bulbs

The description of changing the bulbs applies to several appliance models.

Changing the halogen bulbs Halogen bulbs become very hot during operation. Even some time after the appliance has been switched off, there is still a risk of burns! Before changing the halogen bulbs, ensure that they have cooled down fully. 1. Carefully remove the bulb ring with a suitable tool.

3. Replace the defective bulb with a new one of the same type and equivalent power (see rating plate). 4. Reinsert the bulb cover.
Siemens LC258BA90 — Changing the bulbs diagram (page 15)
Abb. 26 · Changing the bulbs
Siemens LC258BA90 — Changing the bulbs diagram (page 15)
Abb. 27 · Changing the bulbs
2. Replace the defective bulb with a new one of the same type and equivalent power (see rating plate).
5. Restore the power supply by inserting the mains plug or switching on the fuse.
Siemens LC258BA90 — Changing the bulbs diagram (page 15)
Abb. 28 · Changing the bulbs

Defective bulbs should be replaced immediately to avoid overloading the remaining bulbs.

3. Reinsert the bulb cover. 4. Restore the power supply by inserting the mains plug or switching on the fuse.
Page 16 of the Siemens LC258BA90 user manual — Connection of 120 mm ø exhaust air pipe
Seite 16 · Zum Vergrößern klicken
Seite 16

Installation instructions

Prior to installation, always follow the instructions and warnings in the chapter entitled ”Safety instructions”!

Connecting pipes

The diameter of the exhaust air pipes should not be less than 150 mm.

Exhaust-air mode

Round pipes:

The exhaust air is conveyed upwards via a ventilation shaft or directly through the outer wall to the exterior.

We recommend an inner diameter of 150 mm, however at least 120 mm.

Flat ducts must have the same inner cross-

section as round pipes. There should be no sharp bends. Ø 150 mm approx. 177 cm2 Ø 120 mm approx. 113 cm2

If pipe diameters differ:

Use sealing strips.

Before conveying the exhaust air into a non-functioning smoke or exhaust gas flue, obtain the consent of the appropriate heating engineer.

Connection of 150 mm ø exhaust air pipe (recommended size)

Discharge exhaust air in accordance with the official and statutory regulations (e.g. regional building laws).

Attach exhaust air pipe directly to the air-pipe connector and seal appropriately. If using an aluminium pipe, smooth the connection area beforehand.

If the exhaust air is conveyed through the outer wall, a telescopic wall box should be used.

To ensure optimum performance, the extractor hood requires: – a short, straight exhaust air pipe and – the largest possible pipe diameter.

If pipe bends cannot be avoided, ensure the largest possible radii.

Connection of 120 mm ø exhaust air pipe

Attach reducing connector directly to the air- pipe connector.

Attach exhaust air pipe to the reducing connector.

Seal both joints appropriately.

Use only pipes or hoses made of non- combustible material for installation of the exhaust air duct.

The manufacturer of the extractor hoods is not responsible for complaints which can be attributed to planning and design of the pipework.

Page 17 of the Siemens LC258BA90 user manual — Electrical specifications
Seite 17 · Zum Vergrößern klicken
Seite 17

Installation instructions

E LECTRICAL CONNECTION

If a permanent connection is required

Before connecting the appliance to the power supply, always follow the instructions and warnings in the chapter entitled ”Safety instructions”!

A disconnector must be provided on the installation side. Switches with a contact opening of more than 3 mm and all-pole disconnection are regarded as disconnectors. This includes LS switches, fuses and contactors.

The extractor hood may only be connected by a qualified electrician who is familiar with the regulations of the relevant electricity supply company. RISK OF INJURY If the power cord of the extractor hood is damaged, it must be replaced by the manufacturer, his customer service or a similarly qualified person to prevent hazardous situations.

Electrical specifications

The required connection data can be found on the rating plate inside the appliance when the grease filters have been removed. Length of the power cord: approx. 1.30 m. This extractor hood complies with the EC interference suppression regulations.

The extractor hood may be connected to a correctly installed earthed socket only.

Attach the earthed socket as directly as possible behind the flue duct. – The earthed socket should be connected via

its own circuit. – If the earthed socket is no longer accessible

following installation of the extractor hood, a disconnector must be fitted as for a permanent connection.

Page 18 of the Siemens LC258BA90 user manual — Max. weight in kg: 40
Seite 18 · Zum Vergrößern klicken
Seite 18

Installation

The extractor hood is designed to be mounted on the wall.

Installation preparations 1. Mark a centre line on the wall from the ceiling to the lower edge of the extractor hood. 2. Using the enclosed template, mark positions for the screws and, to facilitate attachment, the contour of the attachment area. The lower edge of the template corresponds to the lower edge of the extractor hood. 3. Drill 2x 8 mm holes for attachment of the extractor hood and 2x 8 mm holes for the fixing bracket for the flue duct and press in wall plugs flush with the wall. 4. Screw on the fixing bracket for the flue duct.

During installation, optional accessories may also require fitting.

Observe the minimum distance between hob and extractor hood (see ”Safety instructions”)!

Avoid damaging the sensitive surfaces!

Preparing the wall RISK OF INJURY,

DAMAGE TO PROPERTY Before drilling the holes for the designated installation location, check for concealed electrical cables and other lines.

The wall must be level and vertical.

The enclosed screws and wall plugs are suitable for solid brickwork. Use the appropriate fixing materials for other wall structures (e.g. plaster board, porous concrete, poroton bricks). Ensure that the wall has adequate load bearing capacity.

Ensure that the depth of the drilled holes corresponds with the length of the screws.

Ensure that the wall plugs are secure.

Max. weight in kg: 40

Design subject to modification in line with technical development.

5. Screw on the brackets for the extractor hood: hand tight, max. 3 Nm. Ensure that the washers and brackets are positioned correctly!

Page 19 of the Siemens LC258BA90 user manual — Removing the safety caps
Seite 19 · Zum Vergrößern klicken
Seite 19

Installation

Attachment and alignment 1. Initially remove the protective foil from the back of the extractor hood and, following installation, remove foil completely. 2. Mount the extractor hood, ensuring that the back is attached firmly to the brackets Ⓐ. 3. Align the extractor hood horizontally by turning the brackets.. If required, the extractor hood can be moved to the right or left Ⓑ.

RISK OF INJURY Check that all locking screws and locking caps have been attached securely! 4. Connect the pipes (see ”Connecting pipes”). 5. Connect to the power supply (see ”Electrical connection”).

Removing the safety caps

Remove the locking caps from the brackets using a suitable tool, e.g. a flat-blade screwdriver.

Locking screws and locking caps 1. Mark the holes for the safety screws. Detach the extractor hood, drill holes for the safety screws and press in wall plugs flush with the wall. 2. Attach the extractor hood and screw in the safety screws tightly. 3. Press the safety caps with the arrow upwards onto the brackets until they click into position Ⓒ.

Page 20 of the Siemens LC258BA90 user manual — Installation
Seite 20 · Zum Vergrößern klicken
Seite 20

Installation

Installing the flue ducts RISK OF INJURY The insides of the flue ducts may have sharp edges. We recommend wearing protective gloves during installation. 1. Separate the flue ducts. To do this, remove the adhesive tape. 2. Remove the protective film from both flue ducts. 3. Insert one flue duct into the other.

4. Place flue ducts on the extractor hood, push the inner flue duct upwards and attach the left and right sides to the fixing bracket.
Siemens LC258BA90 — Installation diagram (page 20)
Abb. 29 · Installation

Note the position of the slots in the flue duct! – Exhaust-air mode: Slots of the inner flue

duct downwards. – Circulating-air modeSlots of the inner flue
5. Screw the inner flue duct with 2 screws to the sides of the fixing bracket.

duct upwards.

Siemens LC258BA90 — Installation diagram (page 20)
Abb. 30 · Installation
Page 21 of the Siemens LC258BA90 user manual — Montage ................................................................................................................ 63
Seite 21 · Zum Vergrößern klicken
Seite 21

Tabel de matières

Informations générales ....................................................................................... 46

Conseils pour le respect de l’environnement 46

Avant la première utilisation 46

Consignes de sécurité 47

Conformité d’utilisation 47

Sécurité technique 47

Consignes spéciales pour les appareils de cuisson au gaz 48

Utilisation correcte 49

Montage correct 49

Modes de service 50

Mode Évacuation de l’air 50

Mode Recyclage de l’air 50

Utilisation 51-57

Nettoyage et entretien ....................................................................................... 58

Dépose et incorporation des filtres à graisse ................................................. 59

Dépose et incorporation des filtres à graisse 59

Dépose et incorporation des filtres au charbon actif 59

Remplacement des ampoules 60

Consignes de montage ....................................................................................... 61

Jonction des conduits 61

Branchement électrique 62

Montage 63

Préparatifs du montage 63

Fixation 64

Montage des capots de cheminée 65

Frage zu Siemens LC258BA90 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Siemens LC258BA90

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Siemens LC258BA90 PDF-Anleitung

156 Seiten·3.7 MB·Dunstabzugshaube·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…