aged 8 years and older as well as by per- sons with diminished bodily, sensory or mental perception, or those who lack knowledge or experience, if they are moni- tored or have received instruction concern- ing use and comprehend the possible dan- gers that can result. Children may not play with the appliance. Cleaning and mainte- nance by the user may not be performed by unsupervised children.
This appliance is intended for domestic use and the household environment only.
Please read these instructions carefully, then act accordingly! Store for future refer- ence. These instructions must be included when transferring this appliance to a new owner.
Risk of electric shock! Switch off the mains voltage supply immediately if a fault occurs. Immediately shut off the cold water supply to the appliance should it leak.
do not play with the appliance.
be hot. Please inform and instruct children appropriately.
undertaken by a specialist who complies with the enclosed installation instructions. The safety information in the installation instructions must be observed. We do not accept liability for damage resulting from failure to heed these instructions and the installation instructions.
suitably qualified specialist.
Congratulations on purchasing this Siemens appliance. You have acquired a top-quality product, which will give you a lot of enjoyment.


Getting to know your appliance
This appliance is an electronically-regulated, pressurized continuous-flow heater for decentrally supplying hot water.
The electronic continuous-flow heater heats the water as it flows through the appliance. One or more taps can be sup- plied with warm water.
1 Display 2 Comfort keys 3 Rotary selector switch

Operating the appliance


The display indicates the current operating state and makes it possible to change various settings and retrieve consumption figures via the menu.

The continuous-flow heater switches on and heats the water when the warm water tap is opened. It switches off again if the water tap is closed.
It is designed to save energy and remains dimmed when the appliance is not being used.
The water temperature is set by turning the rotary selector switch.
Briefly pressing the , , , comfort keys enables you to directly select the temperature respectively saved for each key. The display shows the set temperature as well as the associated text and symbol.
The background lighting and the display readout (e. g. 42 °C) light up if either the water tap is opened, the rotary selector switch is turned, or a comfort key is pressed.
The colour of the background lighting changes depending on the set temperature – the colour ranges from blue (cold) to red (hot). The background lighting switches off about 10 sec- onds after the last operation. The display readout (e. g. 42 °C) dims after approximately 2 minutes.
Showering 38 °C approx. Washing hands 35 °C approx.
Bathing 40 °C approx. Rinsing 48 °C approx.

The preset temperatures saved for each key can be changed.
Briefly pressing the , , , keys enables you to directly select the respective temperature setting (see chapter “Setting the water temperature”).
temperature.

Turning and then pressing the rotary selector switch allows you to set the select- ed water temperature and use the menu (see chapter “Using the menu”).
![Page 3 of the Siemens DE2124628M user manual — Menu item Verbrauch [consumption]](/cdn/reader/d7/d789f613d16583de6fd7030cdcccd64434f89de487d38f2541dd2d1f33ab4741/images/page-3.webp?w=400)
The following settings can be selected
The appliance requires less energy to heat the water and therefore economises on costs. The consumption figures for energy, water and the resulting costs can be displayed. In order to retrieve the consumption figures, it is necessary to make some settings via the menu.

Display consumption figures, see chapter “Menu item Verbrauch [consumption]”
Select the menu items
The following menu items can be selected:
Enter current date and time (in order to retrieve consumption figures later on)
[energy] per kWh and Wasser [water] per m³ (in order to retrieve con- sumption figures later on)
Delete all individual en- tries and reload factory default settings
Example of a menu setting
In this example, the language is to be set to Englisch [english].
The factory setting for the menu language is Deutsch [german]. To change the language to Englisch [ english]:
5 seconds.
[setting]. Press the rotary selector switch.
[language]. Press the rotary selector switch.
Example of a consumption readout
[english]. Press the rotary selector switch. The language is now set to English.
To display the energy consumption:
5 seconds.
and enter settings.
[consumption]. Press the rotary selector switch.
[ energy]. Press the rotary selector switch.

The energy consumption of the selected year is displayed in kWh.
The following symbols and characters may be shown in the display.

[month]. The energy consumption of the selected month is displayed in kWh.
Zapfen [last usage]. The energy consumption of the last usage is displayed in kWh.
menu level by pressing the rotary selector switch or select Zurück [back].
The following consumption information can be selected

Average power consump- tion in kWh per year Jahr [year], Monat [month] or letztes Zapfen [last usage]
Average water consump- tion in m³ per Jahr [year], Monat [month] or letztes Zapfen [last usage]
Average cost per m³ water in euros per Jahr [year], Monat [month] or letztes Zapfen [last usage]
You have the option of limiting the temperature to 42 °C, to e. g. prevent children from being accidentally scalded.
Enter settings, see chap- ter “Menu item Ein- stellung [setting]“
To activate the child lock:
To deactivate the child lock:
or

If the set temperature is not reached because the water flow- rate is too high, then lights up.
The appliance can be operated with pre-warmed water (for example, from a solar energy unit). If the supply water tem- perature is warmer than 30 °C, then the symbol lights up in the display.
We ask you to always provide the E-No. and the FD-No. of your appliance when calling in a customer service engineer. You will find the numbers on the ratings plate on the inner side of the front flap.
The contact information for your country can be found on the last pages of these instructions.
set accordingly to lower temperatures.
manner.
This appliance is labelled in accordance with Euro- pean Directive 2012/19/EU concerning used elec- trical and electronic appliances (waste electrical and electronic equipment – WEEE). The guideline determines the framework for the return and recycling of used appliances as appli- cable throughout the EU.
The symbol lights up if the appliance is economically operated.
Please ask your specialist retailer about current disposal facilities.
until it is warm.
Using the appliance after switching off the water supply
The guarantee conditions for this appliance are as defined by our representative in the country in which it is sold.
Details regarding these conditions can be obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be produced when making any claim under the terms of this guarantee.
fusebox).
In addition to the warranty claims against the vendor arising from the sales contract and in addition to our appliance guar- antee, we offer compensation in accordance with the follow- ing conditions:
has been completely forced out of the water pipe.
The appliance is now ready to operate.
– If water damage is caused due to a malfunction of our
AquaStop system, then we shall compensate damages to private consumers.
– The liability guarantees applies for the service life of the
appliance.
– The prerequisite of the guarantee claim is that the appli-
ance is correctly installed and connected with AquaStop in accordance with our instructions. Our guarantee does not extend to cover defective supply piping or faucets up to the AquaStop connection.
– In general, you neither need to supervise appliances with
AquaStop while they are operating nor do you need to shut off the water supply afterward by closing the water tap. The water tap only needs to be shut off during longer absences from your residence, e.g. when going on holi- days lasting several weeks.
temperature is reached.
Subject to change without notice.
Power limit · Solar heated · Saving energy

If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you can remedy the fault yourself by using the following guidelines. You will save yourself the costs of an unnecessary visit by customer service personnel.
Water flow-rate is too low The filter in either the water tap or the showerhead is clogged.
Remove the filter and either clean it or descale it.
A high water temperature is set, but it is not reached.
The continuous-flow heater is connected to a thermostatically-controlled water tap.
Set the temperature on the continuous-flow heater to „60 °C“.
The display is blank. The fuse in the fusebox has tripped/blown. Check the fuse in the fusebox.
The water is not warm. The supply temperature has reduced. Reduce the water flow on the taps until the desired water temperature is reached.
The temperature of the water leaving the tap is higher than the set temperature.
The temperature of the water supplying the continuous-flow heater is higher than the set temperature (e. g. due to pre-warmed water supplied from a solar water heater).
The thermostatic premixer in the domes- tic supply must be set accordingly to lower temperatures.
lights up in the display. The power limit has been reached. Reduce the water flow at the tap or lower the temperature setting on the appliance.
If the fault could not be eliminated, please call customer service.
Water flow-rate is too low despite cleaning of filter using the water tap or showerhead
A filter in the appliance is clogged. Get a servicing expert to clean the appliance.
The display is blank despite fault-free function of the mains electricity supply fuses.
There is a fault in the appliance. Get a servicing expert to check the appliance.
The display shows the error code “E..”.
There is a fault in the appliance. Get a servicing expert to check the appliance.
The display shows “00,0°C”. The air sensor in the appliance detects air in the water and momentarily switches the heating element off.
After a few seconds, the continuous-flow heater automatically goes back into operation.
Fault Cause Solution · Fault Cause Solution · Fault Cause Solution
Häufige Probleme, wahrscheinliche Ursachen und Lösungen.
| Problem | Mögliche Ursache | Abhilfe | |
|---|---|---|---|
| Water flow-rate is too low | The filter in either the water tap or the showerhead is clogged. | Remove the filter and either clean it or descale it. | p.6 |
| A high water temperature is set, but it is not reached. | The continuous-flow heater is connected to a thermostatically-controlled water tap. | Set the temperature on the continuous-flow heater to „60 °C“. | p.6 |
| The display is blank. | The fuse in the fusebox has tripped/blown. | Check the fuse in the fusebox. | p.6 |
| The water is not warm. | The supply temperature has reduced. | Reduce the water flow on the taps until the desired water temperature is reached. | p.6 |
| The temperature of the water leaving the tap is higher than the set temperature. | The temperature of the water supplying the continuous-flow heater is higher than the set temperature (e. g. due to pre-warmed water supplied from a solar water heater). | The thermostatic premixer in the domes- tic supply must be set accordingly to lower temperatures. | p.6 |
| lights up in the display. | The power limit has been reached. | Reduce the water flow at the tap or lower the temperature setting on the appliance. | p.6 |
| Water flow-rate is too low despite cleaning of filter using the water tap or showerhead | A filter in the appliance is clogged. | Get a servicing expert to clean the appliance. | p.6 |
| The display is blank despite fault-free function of the mains electricity supply fuses. | There is a fault in the appliance. | Get a servicing expert to check the appliance. | p.6 |
| The display shows the error code “E..”. | There is a fault in the appliance. | Get a servicing expert to check the appliance. | p.6 |
| The display shows “00,0°C”. | The air sensor in the appliance detects air in the water and momentarily switches the heating element off. | After a few seconds, the continuous-flow heater automatically goes back into operation. | p.6 |
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.