DE
Siemens logo
Offizielle Bedienungsanleitung

Siemens DE2124628M

44 Seiten·23 MB·Klimaregelung - Sonstiges·PDF·ENITJA
Siemens DE2124628M
Inhaltsverzeichnis 27 Abschnitte Intended Use · Important safety information · detergents! · Operating elements and displays · … AnzeigenAusblenden
Page 1 of the Siemens DE2124628M user manual — Operating instructions
Seite 1 · Zum Vergrößern klicken
Seite 1

Intended Use

  • This appliance can be used by children

aged 8 years and older as well as by per- sons with diminished bodily, sensory or mental perception, or those who lack knowledge or experience, if they are moni- tored or have received instruction concern- ing use and comprehend the possible dan- gers that can result. Children may not play with the appliance. Cleaning and mainte- nance by the user may not be performed by unsupervised children.

This appliance is intended for domestic use and the household environment only.

Important safety information

Please read these instructions carefully, then act accordingly! Store for future refer- ence. These instructions must be included when transferring this appliance to a new owner.

  • Keep children away from the appliance.

Risk of electric shock! Switch off the mains voltage supply immediately if a fault occurs. Immediately shut off the cold water supply to the appliance should it leak.

  • Please monitor children to ensure that they

do not play with the appliance.

  • The mixer and the warm water pipe may

be hot. Please inform and instruct children appropriately.

  • The installation and initial start-up must be

undertaken by a specialist who complies with the enclosed installation instructions. The safety information in the installation instructions must be observed. We do not accept liability for damage resulting from failure to heed these instructions and the installation instructions.

  • Do not use aggressive or abrasive cleaning

detergents!

  • Do not use a steam cleaner.
  • The appliance is only to be descaled by a

suitably qualified specialist.

Congratulations on purchasing this Siemens appliance. You have acquired a top-quality product, which will give you a lot of enjoyment.

Operating elements and displays

Siemens DE2124628M — Operating elements and displays diagram (page 1)
Abb. 1 · Operating elements and displays
Siemens DE2124628M — Operating elements and displays diagram (page 1)
Abb. 2 · Operating elements and displays

Operating instructions

Getting to know your appliance

This appliance is an electronically-regulated, pressurized continuous-flow heater for decentrally supplying hot water.

The electronic continuous-flow heater heats the water as it flows through the appliance. One or more taps can be sup- plied with warm water.

1 Display 2 Comfort keys 3 Rotary selector switch

Page 2 of the Siemens DE2124628M user manual — Rotary selector switch
Seite 2 · Zum Vergrößern klicken
Seite 2

Display

Operating the appliance

Siemens DE2124628M — Display diagram (page 2)
Abb. 3 · Display
Siemens DE2124628M — Display diagram (page 2)
Abb. 4 · Display

The display indicates the current operating state and makes it possible to change various settings and retrieve consumption figures via the menu.

Siemens DE2124628M — Display diagram (page 2)
Abb. 5 · Display

Switching the appliance on and off

The continuous-flow heater switches on and heats the water when the warm water tap is opened. It switches off again if the water tap is closed.

It is designed to save energy and remains dimmed when the appliance is not being used.

Setting the water temperature

The water temperature is set by turning the rotary selector switch.

Briefly pressing the , , , comfort keys enables you to directly select the temperature respectively saved for each key. The display shows the set temperature as well as the associated text and symbol.

The background lighting and the display readout (e. g. 42 °C) light up if either the water tap is opened, the rotary selector switch is turned, or a comfort key is pressed.

The colour of the background lighting changes depending on the set temperature – the colour ranges from blue (cold) to red (hot). The background lighting switches off about 10 sec- onds after the last operation. The display readout (e. g. 42 °C) dims after approximately 2 minutes.

Showering 38 °C approx. Washing hands 35 °C approx.

Bathing 40 °C approx. Rinsing 48 °C approx.

Siemens DE2124628M — Setting the water temperature diagram (page 2)
Abb. 6 · Setting the water temperature

The preset temperatures saved for each key can be changed.

Briefly pressing the , , , keys enables you to directly select the respective temperature setting (see chapter “Setting the water temperature”).

ExampleHow to change the “Washing hands” temperature
  • Briefly press the key.
  • Turn the rotary selector switch to the desired new

temperature.

  • Press and hold the key. The new temperature setting is saved when the display shows the symbol and the text “Washing hands” as well as a readout of the new temperature.

Rotary selector switch

Siemens DE2124628M — Rotary selector switch diagram (page 2)
Abb. 7 · Rotary selector switch

Turning and then pressing the rotary selector switch allows you to set the select- ed water temperature and use the menu (see chapter “Using the menu”).

Page 3 of the Siemens DE2124628M user manual — Menu item Verbrauch [consumption]
Seite 3 · Zum Vergrößern klicken
Seite 3

Using the menu

The following settings can be selected

The appliance requires less energy to heat the water and therefore economises on costs. The consumption figures for energy, water and the resulting costs can be displayed. In order to retrieve the consumption figures, it is necessary to make some settings via the menu.

Siemens DE2124628M — Using the menu diagram (page 3)
Abb. 8 · Using the menu

Display consumption figures, see chapter “Menu item Verbrauch [consumption]”

  • Press and hold the rotary selector switch for at least 5 seconds.

Select the menu items

The following menu items can be selected:

  • Turn the rotary selector switch: to switch between the menu items in the current menu level.
  • Briefly press the rotary selector switch: to navigate to the next menu level or to confirm a selection.

Enter current date and time (in order to retrieve consumption figures later on)

[energy] per kWh and Wasser [water] per m³ (in order to retrieve con- sumption figures later on)

  • Select Zurück [back] in the menu.
  • Press any comfort key.

Delete all individual en- tries and reload factory default settings

Menu item Einstellung [setting]

Example of a menu setting

In this example, the language is to be set to Englisch [english].

The factory setting for the menu language is Deutsch [german]. To change the language to Englisch [ english]:

Menu item Verbrauch [consumption]

  • Press and hold the rotary selector switch for at least

5 seconds.

  • Turn the rotary selector switch and select Einstellung

[setting]. Press the rotary selector switch.

  • Turn the rotary selector switch and select Sprache

[language]. Press the rotary selector switch.

  • Turn the rotary selector switch and select Englisch

Example of a consumption readout

[english]. Press the rotary selector switch. The language is now set to English.

To display the energy consumption:

  • Press and hold the rotary selector switch for at least
  • Wait a moment or press the rotary selector switch.

5 seconds.

  • Turn the rotary selector switch. Select other menu items
  • Turn the rotary selector switch and select Verbrauch

and enter settings.

[consumption]. Press the rotary selector switch.

  • Turn the rotary selector switch and select Energie
  • Press any comfort key to exit the menu.

[ energy]. Press the rotary selector switch.

Show 4 more labels / short text on this page
Open the menu · Exit the menu · or · or
Page 4 of the Siemens DE2124628M user manual — Symbols and readouts shown in display
Seite 4 · Zum Vergrößern klicken
Seite 4
  • Turn the rotary selector switch and select Jahr [year] .

Symbols and readouts shown in display

The energy consumption of the selected year is displayed in kWh.

The following symbols and characters may be shown in the display.

  • Turn the rotary selector switch and select Monat
<Menu selection left, turn the rotary selector switch counterclockwise. >Menu selection right, turn the rotary selector switch clockwise. Temperature in degrees celsius Cost in euros Economical operation Power consumption in kilowatt hours Water flow-rate in litres per minute Wasserverbrauch in Liter Water consumption in cubic metres Child lock active (see chapter “Child lock”) Solar heating active (see chapter “Solar heating”) Power limit reached (see chapter “Power limit”) “Rinsing” water temperature active “Showering” water temperature active “Washing hands” water temperature active “Bathing” water temperature active
Siemens DE2124628M — Symbols and readouts shown in display diagram (page 4)
Abb. 9 · Symbols and readouts shown in display

[month]. The energy consumption of the selected month is displayed in kWh.

  • Turn the rotary selector switch and select letztes

Zapfen [last usage]. The energy consumption of the last usage is displayed in kWh.

  • To retrieve other consumption figures, navigate up one

menu level by pressing the rotary selector switch or select Zurück [back].

  • Press any comfort key to exit the menu.

The following consumption information can be selected

Siemens DE2124628M — Symbols and readouts shown in display diagram (page 4)
Abb. 10 · Symbols and readouts shown in display

Average power consump- tion in kWh per year Jahr [year], Monat [month] or letztes Zapfen [last usage]

Average water consump- tion in m³ per Jahr [year], Monat [month] or letztes Zapfen [last usage]

Average cost per m³ water in euros per Jahr [year], Monat [month] or letztes Zapfen [last usage]

You have the option of limiting the temperature to 42 °C, to e. g. prevent children from being accidentally scalded.

Enter settings, see chap- ter “Menu item Ein- stellung [setting]“

To activate the child lock:

  • Simultaneously press and hold the and keys for a few seconds. The Kindersicherung deaktiviert [child lock deactivated] text appears for a few seconds in the display. The symbol lights up. The child lock is now activated.

To deactivate the child lock:

  • Simultaneously press and hold the and keys for a few seconds. The Kindersicherung deaktiviert [child lock deactivated] text appears for a few seconds in the display. The symbol goes out. The child lock is now deactivated.

or

Page 5 of the Siemens DE2124628M user manual — Winter operation
Seite 5 · Zum Vergrößern klicken
Seite 5

Cleaning

If the set temperature is not reached because the water flow- rate is too high, then lights up.

  • Only wipe off the appliance using a moist cloth.
  • Do not use acidic or abrasive cleaning materials.
  • Do not use a steam cleaner.

The appliance can be operated with pre-warmed water (for example, from a solar energy unit). If the supply water tem- perature is warmer than 30 °C, then the symbol lights up in the display.

Customer Service

We ask you to always provide the E-No. and the FD-No. of your appliance when calling in a customer service engineer. You will find the numbers on the ratings plate on the inner side of the front flap.

The contact information for your country can be found on the last pages of these instructions.

Environmentally-friendly disposal

  • The thermostatic premixer in the domestic supply must be

set accordingly to lower temperatures.

  • Dispose of the packaging in an environmentally sound

manner.

This appliance is labelled in accordance with Euro- pean Directive 2012/19/EU concerning used elec- trical and electronic appliances (waste electrical and electronic equipment – WEEE). The guideline determines the framework for the return and recycling of used appliances as appli- cable throughout the EU.

The symbol lights up if the appliance is economically operated.

  • Turn the rotary selector switch until the symbol lights up.

Startup after power failure

  • Open the warm water tap fully and allow water to flow

Please ask your specialist retailer about current disposal facilities.

until it is warm.

Guarantee

Using the appliance after switching off the water supply

The guarantee conditions for this appliance are as defined by our representative in the country in which it is sold.

Details regarding these conditions can be obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be produced when making any claim under the terms of this guarantee.

  • Switch off the appliance (unscrew the fuse in the

fusebox).

  • Open the warm water tap and keep it open until the air

In addition to the warranty claims against the vendor arising from the sales contract and in addition to our appliance guar- antee, we offer compensation in accordance with the follow- ing conditions:

has been completely forced out of the water pipe.

  • Switch the fuse back on again.

The appliance is now ready to operate.

– If water damage is caused due to a malfunction of our

Saving energy

AquaStop system, then we shall compensate damages to private consumers.

  • Set the desired water temperature directly on the appliance.

– The liability guarantees applies for the service life of the

appliance.

– The prerequisite of the guarantee claim is that the appli-

ance is correctly installed and connected with AquaStop in accordance with our instructions. Our guarantee does not extend to cover defective supply piping or faucets up to the AquaStop connection.

Winter operation

– In general, you neither need to supervise appliances with

AquaStop while they are operating nor do you need to shut off the water supply afterward by closing the water tap. The water tap only needs to be shut off during longer absences from your residence, e.g. when going on holi- days lasting several weeks.

  • Reduce the water flow on the taps until the desired water

temperature is reached.

Subject to change without notice.

Power limit · Solar heated · Saving energy

Page 6 of the Siemens DE2124628M user manual — Faults that are automatically remedied
Seite 6 · Zum Vergrößern klicken
Seite 6

A fault, what to do?

If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you can remedy the fault yourself by using the following guidelines. You will save yourself the costs of an unnecessary visit by customer service personnel.

Faults that the customer can troubleshoot himself

Water flow-rate is too low The filter in either the water tap or the showerhead is clogged.

Remove the filter and either clean it or descale it.

A high water temperature is set, but it is not reached.

The continuous-flow heater is connected to a thermostatically-controlled water tap.

Set the temperature on the continuous-flow heater to „60 °C“.

The display is blank. The fuse in the fusebox has tripped/blown. Check the fuse in the fusebox.

The water is not warm. The supply temperature has reduced. Reduce the water flow on the taps until the desired water temperature is reached.

The temperature of the water leaving the tap is higher than the set temperature.

The temperature of the water supplying the continuous-flow heater is higher than the set temperature (e. g. due to pre-warmed water supplied from a solar water heater).

The thermostatic premixer in the domes- tic supply must be set accordingly to lower temperatures.

lights up in the display. The power limit has been reached. Reduce the water flow at the tap or lower the temperature setting on the appliance.

If the fault could not be eliminated, please call customer service.

Faults that the customer service specialist should troubleshoot

Water flow-rate is too low despite cleaning of filter using the water tap or showerhead

A filter in the appliance is clogged. Get a servicing expert to clean the appliance.

The display is blank despite fault-free function of the mains electricity supply fuses.

There is a fault in the appliance. Get a servicing expert to check the appliance.

The display shows the error code “E..”.

There is a fault in the appliance. Get a servicing expert to check the appliance.

Faults that are automatically remedied

The display shows “00,0°C”. The air sensor in the appliance detects air in the water and momentarily switches the heating element off.

After a few seconds, the continuous-flow heater automatically goes back into operation.

Fault Cause Solution · Fault Cause Solution · Fault Cause Solution

Reparatur

Fehlerbehebung

Häufige Probleme, wahrscheinliche Ursachen und Lösungen.

ProblemMögliche UrsacheAbhilfe
Water flow-rate is too lowThe filter in either the water tap or the showerhead is clogged.Remove the filter and either clean it or descale it. p.6
A high water temperature is set, but it is not reached.The continuous-flow heater is connected to a thermostatically-controlled water tap.Set the temperature on the continuous-flow heater to „60 °C“. p.6
The display is blank.The fuse in the fusebox has tripped/blown.Check the fuse in the fusebox. p.6
The water is not warm.The supply temperature has reduced.Reduce the water flow on the taps until the desired water temperature is reached. p.6
The temperature of the water leaving the tap is higher than the set temperature.The temperature of the water supplying the continuous-flow heater is higher than the set temperature (e. g. due to pre-warmed water supplied from a solar water heater).The thermostatic premixer in the domes- tic supply must be set accordingly to lower temperatures. p.6
lights up in the display.The power limit has been reached.Reduce the water flow at the tap or lower the temperature setting on the appliance. p.6
Water flow-rate is too low despite cleaning of filter using the water tap or showerheadA filter in the appliance is clogged.Get a servicing expert to clean the appliance. p.6
The display is blank despite fault-free function of the mains electricity supply fuses.There is a fault in the appliance.Get a servicing expert to check the appliance. p.6
The display shows the error code “E..”.There is a fault in the appliance.Get a servicing expert to check the appliance. p.6
The display shows “00,0°C”.The air sensor in the appliance detects air in the water and momentarily switches the heating element off.After a few seconds, the continuous-flow heater automatically goes back into operation. p.6

Frage zu Siemens DE2124628M stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Siemens DE2124628M

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Siemens DE2124628M PDF-Anleitung

44 Seiten·23 MB·Klimaregelung - Sonstiges·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…