Siemens DE10104M

56 Seiten·2.3 MB·Klimaregelung - Sonstiges·PDF·ENITJA
Siemens DE10104M
Inhaltsverzeichnis 38 Abschnitte without disconnecting the power supply beforehand. ■ Only connect the continuous- · appliance. ■ Please monitor children to en- · is suitable for connection to DVGW-tested plastic pipes. ■ After installation, electri- · the appliance. ■ This appliance can be used by · … AnzeigenAusblenden
Page 1 of the Siemens DE10104M user manual — without disconnecting the power supply beforehand. ■ Only connect the continuous-
Seite 1 · Zum Vergrößern klicken
Seite 1

Safety information This appliance is intended for domestic use and the household environment only.

  • In order to avoid potential

sources of danger, repairs and maintenance may only be undertaken by a suitably qualified specialist. ■Shut off the water supply be-

  • Install and operate the appli-

ance as described in the text and illustrations. We do not accept liability for damage resulting from failure to heed these instructions. ■This appliance is intended

fore connecting the appliance. The electrical connection must be disconnected from the mains supply. Unscrew the fuse or switch off the circuit breaker. ■Never open the appliance

for use up to an altitude of 2000 m above sea level. ■The appliance may only be in-

without disconnecting the power supply beforehand. ■ Only connect the continuous-

stalled and stored in a frost-free room (due to residual water).

flow heater to a cold water line. ■Connect the water supply first,

Risk of electric shock! Switch off the mains volt- age supply immediately if a fault occurs (DE05101M, DE06101M, DE06111M, DE08101M, DE08111M) or disconnect the plug from the mains supply (DE04101M, DE10104M). Immediately shut off the cold water supply to the appliance should it leak. ■The appliance may only

circulate water through the ap- pliance and then connect the electrical supply. ■Observe the statutory regula-

tions as well as the connection regulations of the electrical and water utility companies. ■Compliance with the

IEC60364-7-701 (DIN VDE 0100 Part 701) must be observed during installa- tion of the appliance or the electrical accessories. ■During installation, an all-pole

be connected and put into operation by a qualified professional.

separator must be fitted with a minimum contact gap of 3 mm.

Page 2 of the Siemens DE10104M user manual — the appliance. ■ This appliance can be used by
Seite 2 · Zum Vergrößern klicken
Seite 2
  • The continuous-flow heater is

ence, if they are monitored or have received instruction con- cerning use and comprehend the possible dangers that can result. Children may not play with the appliance. Cleaning and maintenance by the user may not be performed by un- supervised children. ■Keep children away from the

a Class I appliance and must be connected to the protective earth. ■Permanently installed appli-

ances must be permanently connected to fixed wiring. The conductor cross-section must comply with the appliance being installed. ■Caution: Earthed water pipes

appliance. ■ Please monitor children to en-

may give the appearance of a connected protective earth. ■The continuous-flow heater

sure that they do not play with the appliance. ■The warm water pipe may be

is suitable for connection to DVGW-tested plastic pipes. ■ After installation, electri-

hot. Please inform and instruct children appropriately. ■If the power cord of this unit

cally live parts must be touch protected. ■The appliance should be dis-

is damaged, it must be re- placed by the manufacturer, an authorised servicing agent or a similarly qualified person so as to avoid danger. ■Do not use aggressive or abra-

connected from the electrical mains supply when working on the water supply. After ser- vice work is complete, proceed as during the first-time appli- ance start-up. ■No changes may be made to

sive cleaning detergents! ■Do not use a steam cleaner.

  • The appliance is only to be

the appliance. ■ This appliance can be used by

descaled by a suitably quali- fied specialist.

children aged 8 years and old- er as well as by persons with diminished bodily, sensory or mental perception, or those who lack knowledge or experi-

Page 3 of the Siemens DE10104M user manual — Only for DE05101M, DE06101M, DE06111M, DE08101M and DE08111M (fixed electrical connection)
Seite 3 · Zum Vergrößern klicken
Seite 3

Congratulations on purchasing this Siemens appliance. You have acquired a top-quality product, which will give you a lot of enjoyment.

This installation and operating instruction manual describes various appliance types:

Over-sink appliances:

Please read this installation and operating in- struction manual carefully, then act accordingly! Store for future reference.

– DE06111M and DE08111M:

for fixed electrical connection

Undersink appliances:

– DE04101M and DE10104Mwith plug connection

Installation instructions

– DE05101M, DE06101M and DE08101M:

for fixed electrical connection

Install the continuous-flow heater as described in the illustrated section. Observe the instructions in the text.

Only for permanently installed appliances: The device is compliant to IEC 61000-3-12.

The illustrations can be found in the centre of the instruction manual.

II. Preparations for installation

Unpacking

  • Shut off the water supply before connecting

the appliance. The electrical connection must be disconnected from the mains supply. Un- screw the fuse or switch off the circuit breaker.

  • Inspect the new appliance for transport damage!
  • Please dispose of the packaging, and if appli-

cable, the old appliance in an environmentally- friendly manner.

For all appliances

A clearance of about 60 mm on all sides of the appliance is required for installation.

I. Scope of delivery

  • Observe the technical appliance data.

2 Mounting (3 screws, 3 wall plugs)

  • Break out the installation bracket from the rear

3 Operation indicator (only on DE06111M and DE08111M)

of the appliance (A).

Only for DE04101M and DE10104M

  • Break out one of the side knock-outs ( B1 ) pro-

vided for an incoming electrical supply cable.

  • Feed the desired length of the incoming electri-

cal supply cable downwards through the knock- out (B2).

Product description

The electronic continuous-flow heater is suitable for both open (unpressurised) and closed (pressurised) connections. It heats the water as it passes through the appliance.

  • Important: Connect the unit only to a mains

socket with protective contact that is installed according to regulations. Do not use an exten- sion cord. If necessary, equip the unit with a longer cord.

The continuous-flow heater switches on and heats the water when the warm water tap is opened. It switches off as soon as the tap is closed.

Only for DE05101M, DE06101M, DE06111M, DE08101M and DE08111M (fixed electrical connection)

The appliance may not be operated with pre-heated water, as otherwise the overtemperature protection will trip.

  • Press the upper and lower latches ( C1 ), then

remove the housing cover (C2).

Show 5 more labels / short text on this page
1 Housing · 4 Installation bracket · 5 Mounting bracket · 6 Aerator · 7 Documentation
Page 4 of the Siemens DE10104M user manual — Only for DE05101M, DE06101M, DE06111M, DE08101M and DE08111M (fixed electrical connection)
Seite 4 · Zum Vergrößern klicken
Seite 4

III. Wall mounting

IV. Water connection

Leftpressurised (closed); right: unpressurised (open)

Undersink appliances

  • Attach mounting template D to the wall.
  • Mark the locations for the holes; drill the holes
  • The appliance is only approved for heating water

and insert the wall plugs.

with a specific electric resistance of ≥ 1 300 Ωcm at 15 °C. Your water utility company can give you information about the specific water resistance.

  • Attach the installation bracket to the wall using

the screws (D1).

Only for permanently installed appliances:

Installation

  • Pass the connection cable through the cable
  • Ensure the axial fit of the connection pipes in the

grommet, suspend the appliance in the instal- lation bracket and screw it onto the mounting bracket (D2).

nozzles.

  • Tighten the union nuts on the nozzles with an

open-end wrench and counter hold with a suit- able open-end wrench.

Only for appliances with mains plug:

  • The T-piece (for the pressurised connection)
  • Suspend the appliance in the installation bracket

and flexible connection hose are available commercially.

and screw it onto the mounting bracket (D3).

Over-sink appliances

  • Only the approved unpressurised valves may be

used when connecting without pressure (Special accessories: Single-lever mixer tap BZ13062, Two handle fixture BZ13051).

  • Attach mounting template E to the wall.
  • Mark the locations for the holes; drill the holes

and insert the wall plugs.

  • Exchange the perlator from the tap fixture with
  • Attach the installation bracket to the wall ( E1 ).

the supplied aerator to change the spray pattern of the tap.

  • Pass the connection cable through the cable

grommet, suspend the appliance in the instal- lation bracket and screw it onto the mounting bracket (E2).

Controlling temperature

The supply temperature (probably lower in winter) and pressure fluctuations can influence the tem- perature of the water leaving the tap.

Only for DE05101M, DE06101M, DE06111M, DE08101M and DE08111M (fixed electrical connection)

  • Turn the valve slowly in the closed direction for

higher temperatures (F1).

  • The variants for feed through of cables using
  • Add cold water for lower temperatures ( F2 ).

flush mounting electrical connection should be observed on the mounting template.

  • The cable grommet must completely enclose the

connection cable to guarantee optimum protec- tion against dampness. The opening must be sealed watertight if it is damaged.

  • Use the openings provided on the rear for

mounting.

Page 5 of the Siemens DE10104M user manual — DE04101M and DE10104M
Seite 5 · Zum Vergrößern klicken
Seite 5

V. Electrical connection

VI. First start-up

DE05101M, DE06101M, DE06111M, DE08101M and DE08111M (fixed electrical connection)

Initial rinsing

  • Open the warm water tap and allow water to

flow for at least 1 minute (flow-rate at least 2 litres per minute). Only then (for safety rea- sons) will the appliance begin to heat. Info: The appliance will not heat if the dispensed water flow is interrupted prematurely. Open the warm water tap again and allow water to flow for at least 1 minute.

  • Connect the appliance on the terminal strip in

accordance with the connection schematic.

  • Put on the housing cover and push it onto the

rear wall of the appliance so that the upper and lower latches engage.

DE04101M and DE10104M

Replacing the Power Supply Cord:

  • The power supply cord must be replaced by our

customer service only in order to avoid a hazard. The mains plug must be pulled before replacing.

For all appliances

  • Switch off the circuit-breakers/fuses or remove
  • Vent the continuous-flow heater: Fully open

the mains plug.

the warm water tap and flush out the appliance for about 1 minute (G), until bubbles no longer emerge.

  • Remove the flow-rate limiter ( H1 – H4 ).
Siemens DE10104M — For all appliances diagram (page 5)
Abb. 1 · For all appliances

Controlling temperature

The supply temperature (probably lower in winter) and pressure fluctuations can influence the temper- ature of the water leaving the tap (see Fig. IV, left: pressurised [closed], right: unpressurised [open]).

  • Turn the valve slowly in the closed direction for

higher temperatures (F1).

  • Add cold water for lower temperatures ( F2 ).

After installation

  • Hand over the installation and operating instruc-

tions to the user and explain how the appliance operates.

DE05101M, DE06101M, DE06111M, DE08101M and DE08111M (fixed electrical connection)

Switch on the fuses.

DE04101M and DE10104M

  • Insert the plug into the mains socket.
Page 6 of the Siemens DE10104M user manual — Technical data
Seite 6 · Zum Vergrößern klicken
Seite 6

Technical data

Siemens DE10104M — Technical data diagram (page 6)
Abb. 2 · Technical data

Electrical connection [V] 230

Minimum cable cross-section [mm²] 1.5 2.5 4

Rated current [A] 15.7 19.1 26 31.3 26 31.3

Fuse protection [A] 16 20 32

Water connection thread [Inch] G 3/8 G 3/8 G 3/8 G 3/8 G 1/2 G 1/2

Supply temp. max. [°C] 20

Warm water output at supply temp. of 12 °C to 38 °C

Protection type IP 24

[bar] < 0.25 < 0.25 < 0.25 < 0.25 < 0.25 < 0.25

Switch on flow [l/min] 1.8 1.8 / 1.9 1.8 / 2.1 1.8 / 2.3 1.8 / 2.1 1.8 / 2.3

Switch off flow [l/min] 1.6 1.6 / 1.7 1.6 / 2.0 1.6 / 2.2 1.6 / 2.0 1.6 / 2.2

Flow lomit at [l/min] 2 2 3 4 3 4

Application area in waterspecific electric resistance at 15 °C

[Ωcm] ≥ 1 300 ≥ 1 300 ≥ 1 300 ≥ 1 300 ≥ 1 300 ≥ 1 300

Rated pressure [MPa (bar)] 1.0 (10.0) 1.0 (10.0) 1.0 (10.0) 1.0 (10.0) 1.0 (10.0) 1.0 (10.0)

Energy efficiency class A

Annual energy consumption [kWh] 467 470 470 471 470 471

Daily energy consumption [kWh] 2.145 2.150 2.154 2.161 2.154 2.161

Sound power level [dB] 15

Hot water heating energy efficiency [%] 39.4 39.3 39.2 39.1 39.2 39.1

Page 7 of the Siemens DE10104M user manual — Regulating water temperature
Seite 7 · Zum Vergrößern klicken
Seite 7

The temperature of the water leaving the tap is dependent on the flow of water:

ΔT [°C]

50 7,2 kW 6,0 kW 4,5 kW 3,6 kW

Q [l/min]

1,2 1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8 3,0 3,2 3,4 3,6 3,8 4,0 4,2

Operating instructions

Operation

The electronic continuous-flow heaters of this series operate automatically.

Please read and observe the detailed safety instructions at the start of these instructions!

  • Important: The appliance may never be exposed

Switching on

  • Open the tap fully. The electronic continuous-

Risk of electric shock! Switch off the mains voltage supply immediately if a fault occurs (DE05101M, DE06101M, DE06111M, DE08101M, DE08111M) or disconnect the plug from the mains supply (DE04101M, DE10104M).

flow heater switches on. The water is heated as it flows through the appliance. The over-sink appliances DE06111M and DE08111M feature an automatic operation indi- cator. The operation indicator lights yellow at half power and red at full power, dependent on the water flow rate.

  • Immediately shut off the cold water supply to

the appliance should it leak.

Switching off

  • Close the tap, and the appliance will switch off.

Regulating water temperature

  • Open the tap fully, and the appliance switches on.
  • Now increase the temperature of the water by

reducing the flow of water.

Info: In winter, the temperature of the water supply may be lower, so that the temperature of the water leaving the tap will not be reached. Please proceed as described under “Water connection”.

to frost!

Page 8 of the Siemens DE10104M user manual — Customer Service
Seite 8 · Zum Vergrößern klicken
Seite 8

Cleaning

Disposal

Do not use aggressive or abrasive cleaning detergents!

This appliance is labelled in accordance with European Directive 2012/19/EU con- cerning used electrical and electronic ap- pliances (waste electrical and electronic equipment – WEEE). The guideline determines the framework for the return and recycling of used appli- ances as appli cable throughout the EU.

Do not use a steam cleaner.

  • Clean appliance externally with a mild cleaning

agent.

  • Clean the dirt and lime scale deposits in the

aerator filter.

Maintenance

Please ask your specialist retailer about current disposal facilities

Repairs and maintenance may only be carried out by an authorised customer service representative to avoid potential sources of danger.

Guarantee

  • The electrical mains supply and the water supply

The guarantee conditions for this appliance are as defined by our representative in the country in which it is sold. Details regarding these conditions can be obtained from the dealer, from whom the appliance was purchased, or directly from our repre- sentative in the country. Furthermore, the guaran- tee conditions can also be found on the Internet at the website address stated. The bill of sale or receipt must be produced when making any claims under the terms of this guarantee.

must be shut off before all work on the appliance.

Customer Service

We ask you to always provide the E-No. and the FD-No. of your appliance when calling in a custom- er service engineer.

You will find the number between both water con- nection nozzles of the continuous-flow heater.

Subject to change without notice.

Page 9 of the Siemens DE10104M user manual — A fault, what to do?
Seite 9 · Zum Vergrößern klicken
Seite 9

A fault, what to do?

If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you can remedy the fault yourself by using the following guidelines. You will save yourself the costs of an un- necessary visit by customer service personnel.

Fault Cause Solution Who

The appliance does not start (heat), no water flows.

The fuse in the house electri- cal installation has tripped/ blown.

Check the fuse in the house electrical installation.

Power failure or initial start-up.

Starts rinsing: Open the warm water tap and allow water to flow for at least 30 seconds (flow-rate at least 2 litres per minute). Only then (for safety reasons) will the appliance begin to heat.

The air sensor in the appli- ance detects air in the water and momentarily switches the heating element off.

Should the appliance not start because of a reduced flow-rate, remove the perlator, shower head or similar before start and repeat the process.

The desired water temperature leav- ing the tap is no longer reached.

The supply temperature has reduced.

Reduce the water flow on the taps until the desired water temperature is reached.

Water flow-rate is too low.

The filter in either the water tap or the showerhead is clogged.

Remove the filter and either clean it or descale it.

The filter in the corner regu- lating valve is clogged.

Remove, clean and reinstall the filter. Circulate water through the appliance. If necessary, repeat this procedure until the filter is free of particles.

The water is not sufficiently warm.

The appliance‘s automatic circuit breaker has been tripped.

Get the appliance’s automatic cir- cuit breaker checked by an electri- cian. Check the permissible supply temperature.

Water flow-rate is too high and/or the cold water supply temperature is too low.

Use the angle valve to regulate the flow-rate. Check the flow-rate limiter or replace it with a smaller one.

If the fault could not be eliminated, please call customer service.

Show 7 more labels / short text on this page
Customer · Customer · Customer · Customer · Servicing expert · Servicing expert · Servicing expert
Page 10 of the Siemens DE10104M user manual — A fault, what to do?
Seite 10 · Zum Vergrößern klicken
Seite 10
Page 10 of the Siemens DE10104M user manual — A fault, what to do?
Reparatur

Fehlerbehebung

Häufige Probleme, wahrscheinliche Ursachen und Lösungen.

ProblemMögliche UrsacheAbhilfe
The appliance does not start (heat), no water flows.The fuse in the house electri- cal installation has tripped/ blown.Check the fuse in the house electrical installation. p.9
The appliance does not start (heat), no water flows.Power failure or initial start-up.Starts rinsing: Open the warm water tap and allow water to flow for at least 30 seconds (flow-rate at least 2 litres per minute). Only then (for safety reasons) will the appliance begin to heat. Should the appliance not start because of a reduced flow-rate, remove the perlator, shower head or similar before start and repeat the process. p.9
The appliance does not start (heat), no water flows.The air sensor in the appli- ance detects air in the water and momentarily switches the heating element off. p.9
The desired water temperature leav- ing the tap is no longer reached.The supply temperature has reduced.Reduce the water flow on the taps until the desired water temperature is reached. p.9
Water flow-rate is too low.The filter in either the water tap or the showerhead is clogged.Remove the filter and either clean it or descale it. p.9
Water flow-rate is too low.The filter in the corner regu- lating valve is clogged.Remove, clean and reinstall the filter. Circulate water through the appliance. If necessary, repeat this procedure until the filter is free of particles. p.9
The water is not sufficiently warm.The appliance‘s automatic circuit breaker has been tripped.Get the appliance’s automatic cir- cuit breaker checked by an electri- cian. Check the permissible supply temperature. p.9
The water is not sufficiently warm.Water flow-rate is too high and/or the cold water supply temperature is too low.Use the angle valve to regulate the flow-rate. Check the flow-rate limiter or replace it with a smaller one. p.9

Frage zu Siemens DE10104M stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Siemens DE10104M

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Siemens DE10104M PDF-Anleitung

56 Seiten·2.3 MB·Klimaregelung - Sonstiges·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…