AY -A07BE AY -A09BE AY -A12BE AH-A07BE AH-A09BE AH-A12BE
ENGLISH DEUTSCH FRANÇAIS ESPAÑOL ITALIANO PORTUGUÊS ΕΛΛΗΝΙΚΑ NEDERLANDS HECCRBQ TÜRKÇE
SPLIT TYPE ROOM AIR CONDITIONER ZWEITEILIGES KLIMAGERÄT CLIMATISEUR INDIVIDUEL EN DEUX PARTIES ACONDICIONADOR DE AIRE DE DOBLE SERVICIO CONDIZIONATORE D'ARIA DA CAMERA TIPO SPLIT AR CONDICIONADO DE DUAS UNIDADES ΑΙΡΚÃΝΤΙΣΙÃΝ ∆ΩΜΑΤΙÃΥ ΤΥΠÃΥ SPLIT SPLIT-AIRCONDITIONER SPL∑T KL∑MA VTCNZSQ RJZLBWBJZTH LDE;KJXZJUJ NBGF
INDOOR UNIT ZIMMERGERÄT UNIT INTERIEURE UNIDAD INTERIOR UNITA' INTERNA UNIDADE INTERIOR ΕΣΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ BINNEN-UNIT ∑Ç ÜN∑TE DZENHTZZBQ ;KJR
OUTDOOR UNIT AUSSENGERÄT UNIT EXTERIEURE UNIDAD EXTERIOR UNITA' ESTERNA UNIDADE EXTERIOR Ε¥ΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ BUITEN-UNIT DIΩ ÜN∑TE ZFHEÖZBQ ;KJR
OPERATION MANUAL BEDIENUNGSANLEITUNG NOTICE D'UTILISATION MANUAL DE INSTRUCCIONES MANUALE DI ISTRUZIONE MANUAL DE INSTRUÇÕES ΕΓÌΕΙΡΙ∆ΙÃ ΛΕΙΤÃΥΡΓΙΑΣ GEBRUIKSAANWIJZING KULLANMA KILAVUZU РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
AE-A07BE AE-A09BE AE-A12BE AU-A07BE AU-A09BE AU-A12BE




CAUTIONS FOR USE
1 Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage. 2 Do not operate the buttons with wet hand. It may cause electric shock. 3 For safety, turn the circuit breaker off when not using the unit for an extended period of time. 4 Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly in place. 5 Do not put anything on the outdoor unit nor step on it. The object or the person may fall down or drop, causing injury. 6 This unit is designed for residential use. Do not use for other applications such as in a kennel or greenhouse to raise animals or grow plants. 7 Do not place a vessel with water on the unit. If water penetrates into the unit, electrical insulations may deteriorate and cause electric shock. 8 Do not block the air inlets nor outlets of the unit. It may cause insufficient performance or troubles. 9 Be sure to stop the operation and turn the circuit breaker off before performing any maintenance or cleaning. A fan is rotating inside the unit and you may get injured. 10 Do not splash or pour water directly on the unit. Water can cause electrical shock or equipment damage. 11 This appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.

WHEN POWER FAILURE OCCURS This air conditioner has a memory function to store settings when a power failure occurs. After power recovery, the unit will automatically re-start in the same settings which were active before the power failure, except for timer settings. If the timers were set before a power failure, they will need to be re-set after power recovery.
PREHEATING FUNCTION In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on to prevent cold air from blowing out of the unit.
Below are some simple ways to save energy when you use your air conditioner.


4 AUX. Button
6 Power Supply Cord
8 Vertical Adjustment Louvres
9 Horizontal Adjustment Louvres
w AUTO FAN SPEED Lamp (green )
e FAN SPEED Lamp (green )
w e r t
r TIMER Lamp (orange )
t OPERATION Lamp (red )
u Refrigerant Tube and




2 DISPLAY (Liquid Crystal Display)
4 THERMO. (Thermostat) Button
7 TIMER ON Button (for setting the timer)
8 ONE-HOUR OFF TIMER Button
5 6 7 8 9 0 q w
9 TIMER OFF Button (for setting the timer)
q TIMER CANCEL Button
(The heat mode symbol is provided only on models AY-A07BE/AY-A09BE/AY-A12BE)

: HEAT : DRY (only for AY-A07BE/ AY-A09BE/AY-A12BE)
r FAN SPEED SYMBOLS
: AUTO : Manual setting
(The heat mode symbol is provided only on models AY-A07BE/AY-A09BE/AY- A12BE)
t TEMPERATURE AND TIMER COUNT DOWN
u TIMER ON/TIMER OFF INDICATOR
Indicates when timer on or timer off is set.

LOADING BATTERIES Use two size-AAA (R03) batteries.
1 Remove the battery cover at the back of the remote control. 2 Insert batteries in the compart- ment, making sure the ± and
— polarities are correctly aligned.
Point the remote control towards the unit’s signal receiver window and press the desired button. The unit generates a beep when it re- ceives the signal.





In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature when the unit is turned on.
Automatic Operation Mode Thermostat Setting Below 24°C DRY Room Temp. at start-up 24°C-26°C COOL 24°C 26°C-28°C COOL 25°C Above 28°C COOL 26°C
Automatic Operation Mode Thermostat Setting Below 21°C HEAT 23°C 21°C-24°C DRY Room Temp. at start-up 24°C-26°C COOL 24°C 26°C-28°C COOL 25°C Above 28°C COOL 26°C

During opration, the FAN SPEED Lamp will light up in 3 levels (2 levels for DRY mode) on the indicator panel of the unit to indicate the fan speed.
When fan speed is set to AUTO When fan speed is set to manual
To turn off the FAN SPEED Lamp, press the DISPLAY button.

VERTICAL AIR FLOW DIRECTION
The air flow direction is automatically preset in each mode as follows for optimum comfort:
Adjustment range
Press the SWING button on the remote control once. • The vertical adjustment louvre will change its angle continu- ously.
COOL and DRY mode HEAT mode (only for AY-A07BE/AY-A09BE/ AY-A12BE)
The adjustment range is narrower the SWING range in order to pre- vent condensation from dripping.
The range is wide so the air flow can be directed toward the floor.
Hold the horizontal adjustment louvre as shown in the diagram and adjust the air flow direction.
Never attempt to adjust the vertical adjustment louvres manually.

When the ONE-HOUR OFF TIMER is set, the unit will stop operating after one hour.
Press the CANCEL button. • The orange TIMER lamp ( ) on the unit will turn off.
Or, turn the unit off by pressing the ON/OFF but- ton. • The red OPERATION lamp ( ) and the orange TIMER lamp ( ) on the unit will turn off.

TIMER OFF
The unit will turn off automatically according to your setting. Timer duration can be set from minimum 0.5 hours (30 minutes) to maximum 12 hours. Up to 9.5 hours, you can set by 0.5 hours (30 minutes) increments and from 10 to 12 hours, by 1 hour increment.
Point the remote control at the signal receiver win- dow on the unit. 1 Press the TIMER OFF ( ) button and set time as desired.
Hold the button pressed down for fast setting.
stop the operation 2.5 hours later.
When the TIMER OFF is set, the temperature setting is automatically adjusted to prevent the room from becoming excessively hot or too cold while you sleep. (Auto Sleep function)
Press the CANCEL button.
COOL/DRY MODE: • One hour after the timer operation begins, the temperature setting rises 1°C higher than the original thermostat setting.
Press the TIMER button which you wish to change, (TIMER OFF or TIMER ON) and change the time setting.

The unit will turn on automatically according to your setting. Timer duration can be set from minimum 0.5 hours (30 minutes) to maximum 12 hours. Up to 9.5 hours, you can set by 0.5 hours (30 minutes) increments and from 10 to 12 hours, by 1 hour increment.
Point the remote control at the signal reciever window on the unit. 1 Press the TIMER ON ( ) button. • The time setting will change as you press the button as follows.
Hold the button pressed down for fast setting.
Select the mode, temperature and fan speed set- ting as desired.
room temperature to be as desired 6.5 hours later.

Use this mode when the remote control is not available.

Lift the front panel of the indoor unit and press the AUX. button on the operation panel.
Press the AUX. button on the operation panel again.
Air Purifying Filter During operation of the air conditioner, the air purifying filter removes dust and tobacco smoke from the air and discharges clean air. The apatite antibacterial material used in the air purifying filter suppresses activities of adsorbed viruses and other germs. The replacement period for the disposable type is approximately 3~6 months. Contact your dealer for the purchase of this option.

Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance.
CLEANING THE FILTERS The air filters should be cleaned every two weeks.
1 TURN OFF THE UNIT 2 REMOVE THE FILTERS 1 Lift the open panel. 2 Push the air filters up slightly to unlock them. 3 Pull the air filters down to remove them. 3 CLEAN THE FILTERS Use a vacuum cleaner to remove dust. If the filters are dirty, wash them with warm water and a mild detergent. Dry filters in the shade before reinstalling. 4 REINSTALL THE FILTERS 1 Reinstall the filters in the original positions. 2 Close the front panel. 3 Push the center part of the panel firmly to lock it in place.

1 Operate the unit in the COOL mode, temperature setting 32°C, for about half a day to allow the mechanism to thoroughly dry. 2 Stop the operation and unplug the unit. Turn off the circuit breaker, if you have one exclusively for the air conditioner. 3 Clean the filters, then reinstall them.
1 Make sure that the air filters are not dirty. 2 Make sure that nothing obstructs the air inlet or outlet.

UNIT DOES NOT OPERATE The unit will not operate if it is turned on immediately after it is turned off. The unit will not operate immediately after the mode is changed. This is to protect the internal mechanisms. Wait 3 minutes before operating the unit.
SWISHING NOISE The soft, swishing noise is the sound of the refrigerant flowing inside the unit.
UNIT DOES NOT SEND OUT WARM AIR (Models AY-A07BE/AY-A09BE/AY-A12BE) The unit is preheating or de-icing.
ODORS Carpet and furniture odors that entered into the unit and the air conditioner's inner component odors at the early stage of installation may be sent out from the unit.
CRACKING NOISE The unit may produce a cracking noise. This sound is generated by the friction of the front panel and other components expanding or connecting due to a temperature change.
If the unit appears to be malfunctioning, check the following points before calling for service.
Check to see if the circuit breaker has tripped or the fuse has blown.
Check the filters. If dirty, clean them.
Check the outdoor unit to make sure nothing is blocking the air inlet or outlet.
Check the thermostat is proper setting.
Make sure windows and doors are closed tightly.
A large number of people in the room can prevent the unit from achieving the desired temperature.
Check whether any heat- generating appliances are operating in the room.
Check whether the remote control batteries have be- come old and weak.
Try to send the signal again with the remote control pointed properly towards the unit’s signal receiver window.
Check whether the remote control batteries are in- stalled with the polarities properly aligned.
Please call for service when OPERATION Lamp and TIMER Lamp on the indicator panel blink.
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.