DE
Sharp logo
Offizielle Bedienungsanleitung

Sharp AE-A07BE

147 Seiten·4 MB·Klimaanlage·PDF·ENJA
Sharp AE-A07BE
Inhaltsverzeichnis 55 Abschnitte AY -A07BE AY -A09BE AY -A12BE AH-A07BE AH-A09BE AH-A12BE · AY-A07BE AY-A09BE AY-A12BE AH-A07BE AH-A09BE AH-A12BE · AE-A07BE AE-A09BE AE-A12BE AU-A07BE AU-A09BE AU-A12BE · CONTENTS · … AnzeigenAusblenden
AY -A07BE AY -A09BE AY -A12BE AH-A07BE AH-A09BE AH-A12BEp.1AY-A07BE AY-A09BE AY-A12BE AH-A07BE AH-A09BE AH-A12BEp.1AE-A07BE AE-A09BE AE-A12BE AU-A07BE AU-A09BE AU-A12BEp.1CONTENTSp.3PRECAUTIONSp.3WARNINGS FOR USEp.3WARNINGS FOR INSTALLATION / REMOVAL / REPAIRp.3CAUTIONS FOR USEp.4CAUTIONS FOR LOCATION / INSTALLATIONp.4ADDITIONAL NOTES ON OPERATIONp.5OPERATING TEMPERATURE RANGEp.5NOTES FOR MODELS AY-A07BE/AY-A09BE/AY-A12BEp.5DE-ICING FUNCTIONp.5HEATING EFFICIENCYp.5TIPS ON SAVING ENERGYp.5SET THE CORRECT TEMPERATUREp.5PART NAMESp.6INDOOR UNITp.6OUTDOOR UNITp.6AE-A07BE AU-A07BEp.6REMOTE CONTROLp.71 TRANSMITTERp.7L.C.D. REMOTE CONTROL DISPLAYp.7: AUTO : COOLp.7INDICATORp.7USING THE REMOTE CONTROLp.8NOTES:p.8HOW TO USE THE REMOTE CONTROLp.8CAUTIONp.9BASIC OPERATIONp.10ADJUSTING THE AIR FLOW DIRECTIONp.12VERTICAL AIR FLOW DIRECTIONp.12HOW TO ADJUST THE AIR FLOW DIRECTIONp.12Adjustment rangep.12HORIZONTAL AIR FLOW DIRECTIONp.12ONE-HOUR OFF TIMERp.13TO CANCELp.13TIMER OPERATIONp.14TIMER OFFp.140.5H 1.0H 1.5H 10H 11H 12Hp.14TO CANCEL TIMER TIPS ABOUT TIMER OFF OPERATIONp.14TO CHANGE TIMER SETTINGp.14TIMER ONp.15NOTES FOR TIMER SETTING AND OPERATIONp.15AUXILIARY MODEp.16OPTION KITp.16Type AZ-F900Bp.16MAINTENANCEp.17CLEANING THE UNIT AND THE REMOTE CONTROLp.17BEFORE CALLING FOR SERVICEp.18The following conditions do not denote equipment malfunctionsp.18WATER VAPOURp.18IF THE UNIT FAILS TO OPERATEp.18IF THE UNIT FAILS TO COOL (OR HEAT) THE ROOM EFFECTIVELYp.18IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNALp.18
Page 1 of the Sharp AE-A07BE user manual — AY-A07BE AY-A09BE AY-A12BE AH-A07BE AH-A09BE AH-A12BE
Seite 1 · Zum Vergrößern klicken
Seite 1
Sharp AE-A07BE — AY -A07BE AY -A09BE AY -A12BE AH-A07BE AH-A09BE AH-A12BE diagram (page 1)
Abb. 1

R

AY -A07BE AY -A09BE AY -A12BE AH-A07BE AH-A09BE AH-A12BE

ENGLISH DEUTSCH FRANÇAIS ESPAÑOL ITALIANO PORTUGUÊS ΕΛΛΗΝΙΚΑ NEDERLANDS HECCRBQ TÜRKÇE

SPLIT TYPE ROOM AIR CONDITIONER ZWEITEILIGES KLIMAGERÄT CLIMATISEUR INDIVIDUEL EN DEUX PARTIES ACONDICIONADOR DE AIRE DE DOBLE SERVICIO CONDIZIONATORE D'ARIA DA CAMERA TIPO SPLIT AR CONDICIONADO DE DUAS UNIDADES ΑΙΡΚÃΝΤΙΣΙÃΝ ∆ΩΜΑΤΙÃΥ ΤΥΠÃΥ SPLIT SPLIT-AIRCONDITIONER SPL∑T KL∑MA VTCNZSQ RJZLBWBJZTH LDE;KJXZJUJ NBGF

INDOOR UNIT ZIMMERGERÄT UNIT INTERIEURE UNIDAD INTERIOR UNITA' INTERNA UNIDADE INTERIOR ΕΣΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ BINNEN-UNIT ∑Ç ÜN∑TE DZENHTZZBQ ;KJR

OUTDOOR UNIT AUSSENGERÄT UNIT EXTERIEURE UNIDAD EXTERIOR UNITA' ESTERNA UNIDADE EXTERIOR Ε¥ΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ BUITEN-UNIT DIΩ ÜN∑TE ZFHEÖZBQ ;KJR

OPERATION MANUAL BEDIENUNGSANLEITUNG NOTICE D'UTILISATION MANUAL DE INSTRUCCIONES MANUALE DI ISTRUZIONE MANUAL DE INSTRUÇÕES ΕΓÌΕΙΡΙ∆ΙÃ ΛΕΙΤÃΥΡΓΙΑΣ GEBRUIKSAANWIJZING KULLANMA KILAVUZU РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

AY-A07BE AY-A09BE AY-A12BE AH-A07BE AH-A09BE AH-A12BE

AE-A07BE AE-A09BE AE-A12BE AU-A07BE AU-A09BE AU-A12BE

Page 2 of the Sharp AE-A07BE user manual — AY -A07BE AY -A09BE AY -A12BE AH-A07BE AH-A09BE AH-A12BE
Seite 2 · Zum Vergrößern klicken
Seite 2
Page 2 of the Sharp AE-A07BE user manual — AY -A07BE AY -A09BE AY -A12BE AH-A07BE AH-A09BE AH-A12BE
Page 3 of the Sharp AE-A07BE user manual — Inhaltsverzeichnis
Seite 3 · Inhalt
Inhalt

Inhalt

AY -A07BE AY -A09BE AY -A12BE AH-A07BE AH-A09BE AH-A12BEp.1AY-A07BE AY-A09BE AY-A12BE AH-A07BE AH-A09BE AH-A12BEp.1AE-A07BE AE-A09BE AE-A12BE AU-A07BE AU-A09BE AU-A12BEp.1CONTENTSp.3PRECAUTIONSp.3WARNINGS FOR USEp.3WARNINGS FOR INSTALLATION / REMOVAL / REPAIRp.3CAUTIONS FOR USEp.4CAUTIONS FOR LOCATION / INSTALLATIONp.4ADDITIONAL NOTES ON OPERATIONp.5OPERATING TEMPERATURE RANGEp.5NOTES FOR MODELS AY-A07BE/AY-A09BE/AY-A12BEp.5DE-ICING FUNCTIONp.5HEATING EFFICIENCYp.5TIPS ON SAVING ENERGYp.5SET THE CORRECT TEMPERATUREp.5PART NAMESp.6INDOOR UNITp.6OUTDOOR UNITp.6AE-A07BE AU-A07BEp.6REMOTE CONTROLp.71 TRANSMITTERp.7L.C.D. REMOTE CONTROL DISPLAYp.7: AUTO : COOLp.7INDICATORp.7USING THE REMOTE CONTROLp.8NOTES:p.8HOW TO USE THE REMOTE CONTROLp.8CAUTIONp.9BASIC OPERATIONp.10ADJUSTING THE AIR FLOW DIRECTIONp.12VERTICAL AIR FLOW DIRECTIONp.12HOW TO ADJUST THE AIR FLOW DIRECTIONp.12Adjustment rangep.12HORIZONTAL AIR FLOW DIRECTIONp.12ONE-HOUR OFF TIMERp.13TO CANCELp.13TIMER OPERATIONp.14TIMER OFFp.140.5H 1.0H 1.5H 10H 11H 12Hp.14TO CANCEL TIMER TIPS ABOUT TIMER OFF OPERATIONp.14TO CHANGE TIMER SETTINGp.14TIMER ONp.15NOTES FOR TIMER SETTING AND OPERATIONp.15AUXILIARY MODEp.16OPTION KITp.16Type AZ-F900Bp.16MAINTENANCEp.17CLEANING THE UNIT AND THE REMOTE CONTROLp.17BEFORE CALLING FOR SERVICEp.18The following conditions do not denote equipment malfunctionsp.18WATER VAPOURp.18IF THE UNIT FAILS TO OPERATEp.18IF THE UNIT FAILS TO COOL (OR HEAT) THE ROOM EFFECTIVELYp.18IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNALp.18
Page 4 of the Sharp AE-A07BE user manual — CAUTIONS FOR LOCATION / INSTALLATION
Seite 4 · Zum Vergrößern klicken
Seite 4

PRECAUTIONS

CAUTIONS FOR USE

1 Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage. 2 Do not operate the buttons with wet hand. It may cause electric shock. 3 For safety, turn the circuit breaker off when not using the unit for an extended period of time. 4 Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly in place. 5 Do not put anything on the outdoor unit nor step on it. The object or the person may fall down or drop, causing injury. 6 This unit is designed for residential use. Do not use for other applications such as in a kennel or greenhouse to raise animals or grow plants. 7 Do not place a vessel with water on the unit. If water penetrates into the unit, electrical insulations may deteriorate and cause electric shock. 8 Do not block the air inlets nor outlets of the unit. It may cause insufficient performance or troubles. 9 Be sure to stop the operation and turn the circuit breaker off before performing any maintenance or cleaning. A fan is rotating inside the unit and you may get injured. 10 Do not splash or pour water directly on the unit. Water can cause electrical shock or equipment damage. 11 This appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.

CAUTIONS FOR LOCATION / INSTALLATION

  • Make sure to connect the air conditioner to power supply of the rated voltage and frequency. Use of a power supply with improper voltage and frequency can result in equipment damage and possible fire.
  • Do not install the unit in a place where inflammable gas may leak. It may cause fire. Install the unit in a place with minimal dust, fumes and moisture in the air.
  • Arrange the drain hose to ensure smooth drainage. Insufficient drainage may cause wetting of the room, furniture etc.
  • Make sure a leak breaker or a circuit breaker is installed, depending on the installation location, to avoid electrical shock.
Page 5 of the Sharp AE-A07BE user manual — SET THE CORRECT TEMPERATURE
Seite 5 · Zum Vergrößern klicken
Seite 5

ADDITIONAL NOTES ON OPERATION

OPERATING TEMPERATURE RANGE

INDOOR TEMP.OUTDOOR TEMP. COOLINGupper limit32˚C D.B. 23˚C W.B.43˚C D.B. - lower limit21˚C D.B. 15˚C W.B.21˚C D.B. - HEATING (AY-A07BE/AY-A09BE/ AY-A12BE only)upper limit27˚C D.B. -24˚C D.B. 18˚C W.B. lower limit20˚C D.B. --8.5˚C D.B. -9.5˚C W.B.

WHEN POWER FAILURE OCCURS This air conditioner has a memory function to store settings when a power failure occurs. After power recovery, the unit will automatically re-start in the same settings which were active before the power failure, except for timer settings. If the timers were set before a power failure, they will need to be re-set after power recovery.

NOTES FOR MODELS AY-A07BE/AY-A09BE/AY-A12BE

PREHEATING FUNCTION In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on to prevent cold air from blowing out of the unit.

DE-ICING FUNCTION

  • When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the inside and outside fans stop operating.
  • After de-icing is completed, the unit automatically resumes operation in the HEAT mode.

HEATING EFFICIENCY

  • The unit employs a heat pump that draws heat from the outside air and releases it into the room. The outside air temperature therefore greatly affects the heating efficiency.
  • If the heating efficiency is reduced due to low outside temperatures, use an additional heater.
  • It takes time to warm up and heat the entire room because of the forced air circulation system.

TIPS ON SAVING ENERGY

Below are some simple ways to save energy when you use your air conditioner.

SET THE CORRECT TEMPERATURE

  • Setting the thermostat 1°C higher than the desired temperature in the COOL mode (and 2°C lower in the HEAT mode with models AY-A07BE/AY-A09BE/AY-A12BE) will save approximately 10 percent in power consumption.
  • Setting the temperature lower than necessary during cooling operation will result in increased power consumption. BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
  • Blocking direct sunlight during cooling operation will reduce power consumption.
  • Close the windows and doors during cooling opeation (and heating operation with models AY-A07BE/AYA09BE/AY-A12BE). SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR CIRCULATION KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION MAKE MOST OF THE TIMER OFF FUNCTION DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN EXTENDED PERIOD OF TIME
  • The indoor unit still consumes a small amount of power when it is not operating.
Page 6 of the Sharp AE-A07BE user manual — AE-A07BE AU-A07BE
Seite 6 · Zum Vergrößern klicken
Seite 6

PART NAMES

INDOOR UNIT

Sharp AE-A07BE — INDOOR UNIT diagram (page 6)
Abb. 2

4 AUX. Button

6 Power Supply Cord

8 Vertical Adjustment Louvres

9 Horizontal Adjustment Louvres

w AUTO FAN SPEED Lamp (green )

e FAN SPEED Lamp (green )

w e r t

r TIMER Lamp (orange )

t OPERATION Lamp (red )

OUTDOOR UNIT

u Refrigerant Tube and

Sharp AE-A07BE — OUTDOOR UNIT diagram (page 6)
Abb. 3

AE-A07BE AU-A07BE

Sharp AE-A07BE — AE-A07BE AU-A07BE diagram (page 6)
Abb. 4
Show 18 more labels / short text on this page
1 Inlet (Air) · 2 Open Panel · 3 Air Filters · 5 RECEIVER Window · 7 Indicator Panel · 0 Outlet (Air) · q · q Remote Control · y Inlet(Air) · y · Interconnecting Cord · u · i Drainage Hose · o Outlet(Air) · y · u · o · o
Page 7 of the Sharp AE-A07BE user manual — INDICATOR
Seite 7 · Zum Vergrößern klicken
Seite 7

REMOTE CONTROL

1 TRANSMITTER

Sharp AE-A07BE — 1 TRANSMITTER diagram (page 7)
Abb. 5

2 DISPLAY (Liquid Crystal Display)

4 THERMO. (Thermostat) Button

7 TIMER ON Button (for setting the timer)

8 ONE-HOUR OFF TIMER Button

5 6 7 8 9 0 q w

9 TIMER OFF Button (for setting the timer)

q TIMER CANCEL Button

(The heat mode symbol is provided only on models AY-A07BE/AY-A09BE/AY-A12BE)

L.C.D. REMOTE CONTROL DISPLAY

: AUTO : COOL

Sharp AE-A07BE — : AUTO : COOL diagram (page 7)
Abb. 6

: HEAT : DRY (only for AY-A07BE/ AY-A09BE/AY-A12BE)

r FAN SPEED SYMBOLS

: AUTO : Manual setting

(The heat mode symbol is provided only on models AY-A07BE/AY-A09BE/AY- A12BE)

t TEMPERATURE AND TIMER COUNT DOWN

INDICATOR

u TIMER ON/TIMER OFF INDICATOR

Indicates when timer on or timer off is set.

Show 11 more labels / short text on this page
3 ON/OFF Button · 5 DISPLAY Button · 6 MODE Button · 0 FAN Button · w SWING Button · e MODE SYMBOLS · t · y · r · u · y TRANSMITTING SYMBOL
Page 8 of the Sharp AE-A07BE user manual — HOW TO USE THE REMOTE CONTROL
Seite 8 · Zum Vergrößern klicken
Seite 8

USING THE REMOTE CONTROL

LOADING BATTERIES Use two size-AAA (R03) batteries.

1 Remove the battery cover at the back of the remote control. 2 Insert batteries in the compart- ment, making sure the ± and

— polarities are correctly aligned.

  • Lines will be indicated on the display when batteries are properly installed. 3 Reinstall the battery cover.

NOTES:

  • The battery life is approximately one year in normal use.
  • When you replace the batteries, always change both batteries, and make sure they are the same type.
  • If the remote control does not operate properly after replacing the batteries, take out the batteries and reinstall them again after 30 seconds.
  • If you will not be using the unit for a long time, remove the batteries from the remote control.

HOW TO USE THE REMOTE CONTROL

Point the remote control towards the unit’s signal receiver window and press the desired button. The unit generates a beep when it re- ceives the signal.

  • Make sure there is no curtain or other object between the remote control and the unit.
  • The remote control can send signals from up to 7 metres away.
Show 5 more labels / short text on this page
+ · - · - · + · Remote control cover
Page 9 of the Sharp AE-A07BE user manual — CAUTION
Seite 9 · Zum Vergrößern klicken
Seite 9

CAUTION

  • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light.
  • Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal.
  • The unit can be affected by signals transmitted from the remote control of a television, VCR or other equipment used in the same room.
  • Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit and remote control from moisture and shock which can discolour or damage them.
Page 10 of the Sharp AE-A07BE user manual — BASIC OPERATION
Seite 10 · Zum Vergrößern klicken
Seite 10

BASIC OPERATION

Sharp AE-A07BE — BASIC OPERATION diagram (page 10)
Abb. 7
Press the MODE button to select the 1 operation mode. AUTO HEAT COOL DRY HEAT ( is only for AY-A07BE/AY-A09BE/AY-A12BE) Press the ON/OFF button to start op2 eration. • The red OPERATION lamp ( ) on the unit will light. 1 Press the ON/OFF button to start op2 eration. • The red OPERATION lamp ( ) on the unit will light. 3 Press the THERMO. button to set the desired temperature. AUTO/DRY MODE The temperature can be changed in 1°C increments within the range of 2°C higher to 2°C lower from the temperature automatically determined by the air conditioner. COOL(HEAT for AY-A07BE/AY-A09BE/AY-A12BE)MODE The temperature can be set within the range of 18 to 32°C. Please the FAN button to set the de4 sired fan speed. AUTO SOFT LOW HIGH • In the DRY mode, the fan speed is preset to AUTO and cannot be changed.
  • The red OPERATION lamp ( ) on the unit will turn off.
Page 11 of the Sharp AE-A07BE user manual — BASIC OPERATION
Seite 11 · Zum Vergrößern klicken
Seite 11
Sharp AE-A07BE — BASIC OPERATION diagram (page 11)
Abb. 8

In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature when the unit is turned on.

Automatic Operation Mode Thermostat Setting Below 24°C DRY Room Temp. at start-up 24°C-26°C COOL 24°C 26°C-28°C COOL 25°C Above 28°C COOL 26°C

Automatic Operation Mode Thermostat Setting Below 21°C HEAT 23°C 21°C-24°C DRY Room Temp. at start-up 24°C-26°C COOL 24°C 26°C-28°C COOL 25°C Above 28°C COOL 26°C

Sharp AE-A07BE — BASIC OPERATION diagram (page 11)
Abb. 9

During opration, the FAN SPEED Lamp will light up in 3 levels (2 levels for DRY mode) on the indicator panel of the unit to indicate the fan speed.

When fan speed is set to AUTO When fan speed is set to manual

To turn off the FAN SPEED Lamp, press the DISPLAY button.

Page 12 of the Sharp AE-A07BE user manual — CAUTION
Seite 12 · Zum Vergrößern klicken
Seite 12

ADJUSTING THE AIR FLOW DIRECTION

VERTICAL AIR FLOW DIRECTION

The air flow direction is automatically preset in each mode as follows for optimum comfort:

COOL and DRY modeHorizontal air flow HEAT mode (only for AY-A07BE/AY-A09BE/AY-A12BE)Diagonal air flow

HOW TO ADJUST THE AIR FLOW DIRECTION

Adjustment range

Press the SWING button on the remote control once. • The vertical adjustment louvre will change its angle continu- ously.

COOL and DRY mode HEAT mode (only for AY-A07BE/AY-A09BE/ AY-A12BE)

  • Press the SWING button again when the vertical adjustment louvre is at the desired position.
  • The louvre will stop moving within the range shown in the diagram.
  • The adjusted position will be memorized and will be automatically set to the same position when operated the next time.

The adjustment range is narrower the SWING range in order to pre- vent condensation from dripping.

The range is wide so the air flow can be directed toward the floor.

HORIZONTAL AIR FLOW DIRECTION

Hold the horizontal adjustment louvre as shown in the diagram and adjust the air flow direction.

CAUTION

Never attempt to adjust the vertical adjustment louvres manually.

  • Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction when the remote control is used for the adjustment.
  • When the vertical adjustment louvre is positioned at the lowest position in the COOL or DRY mode for an extended period of time, condensation may result.
Page 13 of the Sharp AE-A07BE user manual — NOTES:
Seite 13 · Zum Vergrößern klicken
Seite 13

ONE-HOUR OFF TIMER

When the ONE-HOUR OFF TIMER is set, the unit will stop operating after one hour.

  • 1 Press the ONE-HOUR OFF TIMER button.
  • The remote control displays “ ”.
  • The orange TIMER lamp ( ) on the unit will light up.
  • The unit will stop operating after one hour.

TO CANCEL

Press the CANCEL button. • The orange TIMER lamp ( ) on the unit will turn off.

Or, turn the unit off by pressing the ON/OFF but- ton. • The red OPERATION lamp ( ) and the orange TIMER lamp ( ) on the unit will turn off.

NOTES:

  • The ONE-HOUR OFF TIMER operation has priority over TIMER ON and TIMER OFF operations.
  • When the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will operate for an hour with the formerly set condition.
  • If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER activiates, press the ONE-HOUR OFF TIMER button again during operation.
Page 14 of the Sharp AE-A07BE user manual — TO CHANGE TIMER SETTING
Seite 14 · Zum Vergrößern klicken
Seite 14

TIMER OPERATION

TIMER OFF

The unit will turn off automatically according to your setting. Timer duration can be set from minimum 0.5 hours (30 minutes) to maximum 12 hours. Up to 9.5 hours, you can set by 0.5 hours (30 minutes) increments and from 10 to 12 hours, by 1 hour increment.

Point the remote control at the signal receiver win- dow on the unit. 1 Press the TIMER OFF ( ) button and set time as desired.

  • The time setting will change as you to press the button as follows,

0.5H 1.0H 1.5H 10H 11H 12H

Hold the button pressed down for fast setting.

  • The orange TIMER lamp ( ) on the unit will light.
  • The unit will generate a beep when it receives the signal.
  • The time setting will count down to show remaining time.
ExampleWhen you wish to

stop the operation 2.5 hours later.

TO CANCEL TIMER TIPS ABOUT TIMER OFF OPERATION

When the TIMER OFF is set, the temperature setting is automatically adjusted to prevent the room from becoming excessively hot or too cold while you sleep. (Auto Sleep function)

Press the CANCEL button.

  • The orange TIMER lamp ( ) on the unit will turn off.

COOL/DRY MODE: • One hour after the timer operation begins, the temperature setting rises 1°C higher than the original thermostat setting.

HEAT MODE(only for models AY-A07BE/AY-A09BE/AY-A12BE)

TO CHANGE TIMER SETTING

  • One hour after the timer operation begins, the temperature setting drops 3°C lower than the original thermostat setting.

Press the TIMER button which you wish to change, (TIMER OFF or TIMER ON) and change the time setting.

Page 15 of the Sharp AE-A07BE user manual — NOTES FOR TIMER SETTING AND OPERATION
Seite 15 · Zum Vergrößern klicken
Seite 15

TIMER ON

The unit will turn on automatically according to your setting. Timer duration can be set from minimum 0.5 hours (30 minutes) to maximum 12 hours. Up to 9.5 hours, you can set by 0.5 hours (30 minutes) increments and from 10 to 12 hours, by 1 hour increment.

Point the remote control at the signal reciever window on the unit. 1 Press the TIMER ON ( ) button. • The time setting will change as you press the button as follows.

0.5H 1.0H 1.5H 10H 11H 12H

Hold the button pressed down for fast setting.

  • The orange TIMER lamp ( ) on the unit will light.
  • The unit will generate a beep when it receives the signal.
  • The time setting will count down to show remaining time.

Select the mode, temperature and fan speed set- ting as desired.

  • When the temperature is set with the TIMER ON, the temperature will show in the display for 5 seconds and then return to the time display.
  • If you do not change the setting, the unit will operate with the latest setting.
  • The unit will turn on prior to the set time to allow the room to reach the desired temperature by the programmed time. (Awaking function)
ExampleWhen you wish the

room temperature to be as desired 6.5 hours later.

NOTES FOR TIMER SETTING AND OPERATION

  • The latest time setting will be memorized and will appear on the remote control display the next time you set the TIMER OFF or TIMER ON.
  • TIMER OFF and TIMER ON can not be set together. The latest set TIMER will be active.
  • When ONE-HOUR OFF TIMER is set, TIMER OFF and TIMER ON will not be available.
  • When ONE-HOUR OFF TIMER is set during TIMER OFF or TIMER ON duration, the TIMER ON or TIMER OFF will be cancelled.
Page 16 of the Sharp AE-A07BE user manual — Type AZ-F900B
Seite 16 · Zum Vergrößern klicken
Seite 16

AUXILIARY MODE

Use this mode when the remote control is not available.

Sharp AE-A07BE — AUXILIARY MODE diagram (page 16)
Abb. 10

Lift the front panel of the indoor unit and press the AUX. button on the operation panel.

  • The red OPERATION lamp ( ) on the unit will light and the unit will start operating in the AUTO mode.
  • The fan speed and temperature setting are set to AUTO.

Press the AUX. button on the operation panel again.

  • The red OPERATION lamp ( ) on the unit will turn off.

OPTION KIT

Air Purifying Filter During operation of the air conditioner, the air purifying filter removes dust and tobacco smoke from the air and discharges clean air. The apatite antibacterial material used in the air purifying filter suppresses activities of adsorbed viruses and other germs. The replacement period for the disposable type is approximately 3~6 months. Contact your dealer for the purchase of this option.

Type AZ-F900B

Page 17 of the Sharp AE-A07BE user manual — CAUTION
Seite 17 · Zum Vergrößern klicken
Seite 17

MAINTENANCE

CAUTION

Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance.

CLEANING THE FILTERS The air filters should be cleaned every two weeks.

1 TURN OFF THE UNIT 2 REMOVE THE FILTERS 1 Lift the open panel. 2 Push the air filters up slightly to unlock them. 3 Pull the air filters down to remove them. 3 CLEAN THE FILTERS Use a vacuum cleaner to remove dust. If the filters are dirty, wash them with warm water and a mild detergent. Dry filters in the shade before reinstalling. 4 REINSTALL THE FILTERS 1 Reinstall the filters in the original positions. 2 Close the front panel. 3 Push the center part of the panel firmly to lock it in place.

CLEANING THE UNIT AND THE REMOTE CONTROL

CAUTION

  • Wipe them with a soft cloth.
  • Do not directly splash or pour water on them. We can cause electrical shock or equipment damage.
  • Do not use hot water, thinner, abrasive powders or strong solvents.
Sharp AE-A07BE — CAUTION diagram (page 17)
Abb. 11

1 Operate the unit in the COOL mode, temperature setting 32°C, for about half a day to allow the mechanism to thoroughly dry. 2 Stop the operation and unplug the unit. Turn off the circuit breaker, if you have one exclusively for the air conditioner. 3 Clean the filters, then reinstall them.

1 Make sure that the air filters are not dirty. 2 Make sure that nothing obstructs the air inlet or outlet.

Page 18 of the Sharp AE-A07BE user manual — IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL
Seite 18 · Zum Vergrößern klicken
Seite 18

BEFORE CALLING FOR SERVICE

The following conditions do not denote equipment malfunctions

UNIT DOES NOT OPERATE The unit will not operate if it is turned on immediately after it is turned off. The unit will not operate immediately after the mode is changed. This is to protect the internal mechanisms. Wait 3 minutes before operating the unit.

SWISHING NOISE The soft, swishing noise is the sound of the refrigerant flowing inside the unit.

WATER VAPOUR

  • In the COOL and DRY operation, water vapour can sometimes be seen at the air outlet due to the difference between the room air temperature and the air discharged by the unit.
  • In the HEAT operation, water vapour may flow out of the outdoor unit during de-icing. (Only in models AYA07BE/AY-A09BE/AY-A12BE)

UNIT DOES NOT SEND OUT WARM AIR (Models AY-A07BE/AY-A09BE/AY-A12BE) The unit is preheating or de-icing.

ODORS Carpet and furniture odors that entered into the unit and the air conditioner's inner component odors at the early stage of installation may be sent out from the unit.

CRACKING NOISE The unit may produce a cracking noise. This sound is generated by the friction of the front panel and other components expanding or connecting due to a temperature change.

If the unit appears to be malfunctioning, check the following points before calling for service.

IF THE UNIT FAILS TO OPERATE

Check to see if the circuit breaker has tripped or the fuse has blown.

IF THE UNIT FAILS TO COOL (OR HEAT) THE ROOM EFFECTIVELY

Check the filters. If dirty, clean them.

Check the outdoor unit to make sure nothing is blocking the air inlet or outlet.

Check the thermostat is proper setting.

Make sure windows and doors are closed tightly.

A large number of people in the room can prevent the unit from achieving the desired temperature.

Check whether any heat- generating appliances are operating in the room.

IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL

Check whether the remote control batteries have be- come old and weak.

Try to send the signal again with the remote control pointed properly towards the unit’s signal receiver window.

Check whether the remote control batteries are in- stalled with the polarities properly aligned.

Please call for service when OPERATION Lamp and TIMER Lamp on the indicator panel blink.

Frage zu Sharp AE-A07BE stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Sharp AE-A07BE

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Sharp AE-A07BE PDF-Anleitung

147 Seiten·4 MB·Klimaanlage·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…