Instructions and Guarantee
This equipment needs to be installed and put into service in accordance
with the information provided in this manual

This Thermometer is intended to be used as the intermittent measurement of human body temperature for people of all ages in the home environment. Utilizing infrared technology, this thermometer takes temperatures in seconds by measuring heat generated by the ear. This product conforms to the provisions of the EC directive MDD(93/42/EEC). Its advantages include: 1. Ear measurement 2. Probe cover not required 3. Waterproof probe design 4. One-second reading 5. Auto power off for power saving 6. Low-battery Indicator 7. Warning indication - indications for battery condition and measuring range. 8. Jumbo LCD Display 9. Memory function
When using this product, please be sure to follow all the notes listed below. Any action against these notices may cause injury or affect the accuracy.
1. Do not disassemble, repair, or remodel the thermometer. 2. Be sure to clean the thermometer lens each time after usage. 3. Avoid direct finger contact with the lens. 4. No modification of this equipment is allowed. 5. It is recommended that user may take 3 temperatures. If they are different, use the highest reading. 6. Do not expose the thermometer to extreme temperature, very high humidity, or direct sunlight. 7. Avoid extreme shock or dropping the device. 8. Before the measurement, users and thermometer should stay in steady state room condition for at least 30 minutes. 9. Avoid measuring temperature for 30 minutes after exercise, bathing, or returning from outdoors.

10. To protect the environment, dispose of empty batteries at appropriate collection sites according to national or local regulations. 11. It is ill-advised to disassemble the thermometer. 12. Please use the thermometer solely for its intended purpose. 13. Carefully hold the device when in use to avoid dropping the device. 14. Allow one minute between successive measurements as slight variations may occur if measurements are taken over a short period of time. Use average temperatures instead. 15. There are no absolute body temperature standards. Keep reliable records of your personal temperature to serve as a reference for judging a fever. 16. Under any circumstances, the temperature taking result is ONLY for reference. Before taking any medical action, please consult your doctor. 17. It is recommended calibrate the device every 1 year.

Memory symbol and sets of records
Celcius scale Fahrenheit scale
Smiling face Measurement
Scan in progress Frowning face Measurement ≥38.0°C(≥ 100.4°F) Fever
Temperature in degrees · Low battery warning · No Fever

Under 1 year Have child lay flat with the head sideways, so that the ear is facing upwards. Gently pull the ear straight back.
1 year + Stand behind and slightly to the side of the child/adult. Gently pull the ear up and back to straighten the ear canal.
3. Insert the probe into the ear canal (the probe must insert well to ensure an accurate temperature measurement), then press the Power & Measure Button for about 1 second, release the button and you will hear 1 short beep sound means complete the measurement. 4. You may take out the device to read the measurement result. 5. The backlight display will remain light for approximately 5 seconds each time the Power & Measure Button is pressed, after each reading is completed, and each time the Memory button is pressed to recall a previous reading. 6. The thermometer will automatically shut off after one minute without use.



The readings If the temperature measurement is below 38°C (100.4°C), a smiling face will be appear next to the reading.
If the reading is 38°C (100.4°C) or above, a frowning face will be displayed.
Changing °C/ °F, please make sure the device is in power on condition. Press the Power & Measure and Memory Recall buttons together to toggle between °C and °F.
You can recall up to 10 stored measurements in memory to share with your doctor or trained healthcare professional. 1. Press the Memory Recall button. The first reading displayed is the latest measurement stored in memory. 2. Continue to press the Memory Recall button button to view the next previously stored measurement. 3. Any new measurement will be recorded and the oldest memory deleted without you having to do anything.

For home use device disinfection, 70% Ethanol or Isopropyl alcohol (available in the pharmacy) can be used. Clean the measuring sensor after each use. Use a clean cloth or cotton bud that can be moistened with 70 % alcohol.
Lens/ Measurement Sensor Gently clean with an alcohol swab. Do not use water to wash the thermometer lens directly.
Thermometer Clean with a soft, dry cloth. Do not use water to rinse the device.
This product conforms to the provisions of the EC directive MDD(93/ 42/ EEC). The following standards apply to design and/or manufacture of the products:
ISO 80601-2-56 Medical electrical equipment -- Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement
IEC/EN 60601-1 Medical electrical equipment- Part 1: General requirement for safety
IEC/EN 60601-1-2 Medical electrical equipment- Part 2: Collateral standard: Electromagnetic compatibility - Requirements and tests
IEC/EN 60601-1-11 Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment


Low battery warning When the batteries get weak, the battery warning symbol appears . It is still possible to measure temperature. The batteries must be replaced. When the battery symbol flashes and Lo appears in the display, the batteries must be replaced. If the batteries are too flat, then the thermometer will switch off automatically.
Replacing the Battery 1. Use a Phillips head screwdriver to loosen battery cover screw. Remove the battery cover. 2. Remove used battery. 3. Replace with a lithium 3V CR2032 battery in designated area. The + sign on the battery should be facing upwards. 4. Place the battery cover on the thermometer and tighten the screw to secure it in place.


This device is an adjusted mode clinical thermometer the validated information for clinical accuracy in each adjusted mode are: GroupA1: ∆cb=-0.01°C, LA=0.18, δr = ±0.08°C GroupA2: ∆cb= 0.06°C, LA=0.22, δr = ±0.08°C GroupB : ∆cb=-0.01°C, LA=0.20, δr = ±0.07°C GroupC : ∆cb=-0.01°C, LA=0.18, δr = ±0.07°C
When a malfunction or incorrect temperature measurement occurs, an error message will appear as described below.

Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information.
1. Electromagnetic/Radio Frequency Interference (EMC/RFI): Readings may be affected if the unit is operated within a radio frequency electromagnetic field strength of approximately 3 volts per metre, but the performance of the instrument will not be permanently affected. Care should be taken to keep the thermometer at least 15cm/6 inches away from R/C transmitters to avoid radio frequency interference. 2. Avoid keeping the thermometer too close to objects that continuously generate high heat (like a hot plate) for long periods of time, which can cause overheating of the thermometer.

Table 1 For all ME EQUIPMENT and ME SYSTEMS

Table 2 For all ME EQUIPMENT and ME SYSTEMS

Table 3 For EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING
Guidance and manufacturer’s declaration-electromagnetic immunity
The Ear Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the Ear Thermometer should assure that it is used in such an environment.
Immunity test IEC 60601 test level
Compliance level Electromagnetic environment-guidance
Conducted RF IEC 61000-4-6
3Vrms 150kHz to 80 MHz
Portable and mobile RF communications equipment should be used no closer to any part of the Ear Thermometer, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance. d=1.2 d=1.2 80 MHz to 800 MHZ d=2.3 800 MHz to 2,5 Ghz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey,” should be less than the compliance level in each frequency range.” Interference may occur in the vicinity of equipment marked with the following symbol:
Radiated RF IEC 61000-4-3
3V/m 80MHz to 2.5 GHz
Field strengths from fixed transmitters, such as base stations from radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast can not be predicted theoretic call with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Ear Thermometer is used exceeds the applicable RF compliance level above, the Ear Thermometer should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the Ear Thermometer. Over the frequency range 150kHz to 80MHz, field strengths should be less than [V1] V/m.
3 Vrms · 3 V/m

Table 4 For EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING
Recommended separation distances between portable and mobile RF communications equipment and the Ear Thermometer
The Ear Thermometer is intended for use in an electromagnetic environment in which radiated RF distances are controlled. The customer or the user of the Ear Thermometer can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Ear Thermometer as recommended below according to the maximum output power of the communications equipment.
Rated maximum output power of
Separation distance according to frequency of transmitter / m
150 kHz to 80 MHZ d=1.2
80 MHz to 800 MHZ d=1.2
800 MHz to 2.5 GHz d=2.3
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
1 1.2 1.2 2.3
10 3.8 3.8 7.3
100 12 12 23
2 YEAR GUARANTEE FKA Brands Ltd guarantees this product from defect in material and workmanship for a period of 2 years from the date of purchase, except as noted below. This FKA Brands Ltd product guarantee does not cover damage caused by misuse or abuse; accident; the attachment of any unauthorised accessory; alteration to the product; or any other conditions whatsoever that are beyond the control of FKA Brands Ltd. This guarantee is effective only if the product is purchased and operated in the UK / EU. A product that requires modification or adaptation to enable it to operate in any country other than the country for which it was designed, manufactured, approved and / or authorised, or repair of products damaged by these modifications is not covered under this guarantee. FKA Brands Ltd shall not be responsible for any type of incidental, consequential or special damages. To obtain guarantee service on your product, return the product post-paid to your local service centre along with your dated sales receipt (as proof of purchase). Upon receipt, FKA Brands Ltd will repair or replace, as appropriate, your product and return it to you, post-paid. Guarantee is solely through Salter Service Centre. Service of this product by anyone other than the Salter Service Centre voids the guarantee. This guarantee does not affect your statutory rights. For your local Salter Service Centre, go to www.salterhousewares.co.uk/servicecentres
transmitter / W

The CE marking with the Registration Number of the Notified Body. This denotes the compliance of European Medical Device Directive 93/42/EEC
Consult the instruction for use
Disposal information: Should you wish to dispose of the article, do so in accordance with current regulations. Details are available from your local authority
Type of protection of applied part against electric shock, body floating
This product meets the basic safety and essential performance requirements indicated in the IP22 conditioning test (protection against solid foreign objects of 12.5mm Ø and greater and against vertically falling water drops when enclosure tilted up to 15°)
Manufacturer’s name and address
SN YYMWWWXXXXX SN: Product Serial Number YY: year, MM: month, WWW: working sheet, XXXXX: serial no.
The empty, completely flat batteries must be disposed of through specially designated collection boxes, recycling points or electronics retailers. You are legally required to dispose of the batteries.
RoHS This product fulfilling the requirements of the RoHS Directive 2011/65/EU.
This product fulfilling the requirements of the REACH Directive EC 1907/2006 and its amendments, do not contain Substances of Very High Concern in concentration above the limit of 0.1 %. No substance(s) is/are present in the parts of the product above the concentration of 0.1 % weight by weight.
Temperature limits · European Authorized Representative
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.