Philips PSD1211

360 Seiten·2.9 MB·Beleuchtung·PDF·ENJA
Philips PSD1211
Inhaltsverzeichnis 16 Abschnitte PSD1211 · Important · Contraindications Do not use the Philips BlueControl: · - If you have any known idiopathic · … AnzeigenAusblenden
Page 1 of the Philips PSD1211 user manual — PSD1211
Seite 1 · Zum Vergrößern klicken
Seite 1

PSD1211

Philips PSD1211 — PSD1211 diagram (page 1)
Abb. 1
Page 2 of the Philips PSD1211 user manual — PSD1211
Seite 2 · Zum Vergrößern klicken
Seite 2
Philips PSD1211 — PSD1211 diagram (page 2)
Abb. 2
Page 3 of the Philips PSD1211 user manual — PSD1211
Seite 3 · Zum Vergrößern klicken
Seite 3
Page 3 of the Philips PSD1211 user manual — PSD1211
Page 4 of the Philips PSD1211 user manual — Important
Seite 4 · Zum Vergrößern klicken
Seite 4

Read this user manual carefully before you use the Philips BlueControl and save the user manual for future reference. To achieve optimal treatment results, use the device according to the treatment schedule and the instructions in this user manual.

List of product codes

- Kit PSK0202/10 - Device PSD1211/10 - Fixation strap PSS1210/10 - Adapter with USB cable PR3089

The Philips BlueControl is intended to provide phototherapeutic light to the body. The Philips BlueControl is generally indicated to treat dermatological conditions. The Philips BlueControl is a wearable medical device using blue LED light to treat mild to moderate psoriasis vulgaris for adults only (i.e. people over the age of 18) in the home environment.

Important

Contraindications Do not use the Philips BlueControl:

- If your skin is burnt or sunburnt. - If you have a fever. - If you have a known sun allergy. - If you are allergic to the surface

materials of the Philips BlueControl device (polycarbonate or polyester/ elastane mix).

Introduction · Intended use

Page 5 of the Philips PSD1211 user manual — skin more susceptible to irritation. - If you have infections, unhealed
Seite 5 · Zum Vergrößern klicken
Seite 5

- If you have any known idiopathic

dermatosis such as porphyria, polymorphic light eruption, chronic actinic dermatitis, actinic prurigo or solar urticaria that causes photosensitivity. - If you have any known disease

related to low immunity. - If you have active skin cancer, if you

have a history of skin cancer or any other localised cancer, precancerous lesions or large moles in the areas to be treated. - If you are taking photosensitising

agents or medications, check the package insert of your medicine and never use the device if it is stated that it can cause photo-allergic reactions, photo-toxic reactions or if you have to avoid sun when taking this medicine. - If you are on steroids, it makes the

skin more susceptible to irritation. - If you have infections, unhealed

tattoos, burns, inflammation of hair follicles, open lacerations, abrasions, herpes simplex, or wounds in the areas to be treated.

Page 6 of the Philips PSD1211 user manual — Danger
Seite 6 · Zum Vergrößern klicken
Seite 6

- Avoid treatment of skin areas with

tattoos, there is no information available yet about possible reactions. - If you have uncontrolled arterial

hypertension, a history of stroke, myocardial infarction, angina pectoris, arteriosclerotic vascular disease (ASVD). - If you are pregnant or breastfeeding. - If you have schizophrenia, borderline

syndrome or severe depression. - If you have any sensory deprivation

or have been diagnosed with shingles or post-herpetic neuralgia, especially in the area to be treated. - If you have any anatomical pathology

or other physical limitation which would prevent you from placing the Philips BlueControl successfully. - If you have an active implanted

device, such as a cardiac pacemaker, defibrillator, neurostimulator, cochlear implant, or an active drug administration device. - If you are in poor general health. Important safety information

Danger

- Keep the adapter dry.

Page 7 of the Philips PSD1211 user manual — Warning
Seite 7 · Zum Vergrößern klicken
Seite 7

Warning

- Never immerse the Philips BlueControl

in water or any other liquid. - Never wear the Philips BlueControl

while it is charging. - Never look directly into the light

source during use. - Do not open or modify the Philips

BlueControl during the lifetime of the device. - Do not use the Philips BlueControl

in wet and/or hot surroundings, such as a sauna or bathroom. - The Philips BlueControl is not

intended to be used by persons younger than 18 and persons with reduced physical, sensory or mental capabilities. - This is a medical device. Keep the

device out of the reach of children. - Only charge the Philips BlueControl

with the USB cable and the adapter supplied (PR3089). - The Philips BlueControl is specifically

designed to treat psoriasis vulgaris. Do not use it for any other purpose.

Page 8 of the Philips PSD1211 user manual — - Remove the Philips BlueControl
Seite 8 · Zum Vergrößern klicken
Seite 8

- Always check the Philips

BlueControl, the USB cable and the adapter for damage before use. - Do not use the device if it is closer than

1 metre to wireless communication equipment, such as wireless home network routers and mobile phones. This wireless communication equipment may cause electromagnetic interference that prevents the device from operating properly. - If the USB cable, the adapter or

the Philips BlueControl is damaged, stop using it and contact the Philips Consumer Care Centre at this telephone number 00800-7445 4778. Caution

- Remove the Philips BlueControl

from the fixation strap before you wash the fixation strap. - Use, charge and store the Philips

BlueControl at a temperature between 10°C and 35°C and at a relative humidity between 30% and 90%. - Read section ‘Contraindications’

to find out if any apply to you before you start using the Philips BlueControl.

Page 9 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 9 · Zum Vergrößern klicken
Seite 9

- To prevent damage to the drum of the

washing machine, to other laundry in the drum or the fabric of the fixation strap, close the Velcro fasteners of the slings and wash the fixation strap and the slings in a fine-mesh washing bag. - Always use the Philips BlueControl

in the fixation strap with one of the slings provided, as the fixation strap and the slings have been specially designed for this device. - Philips BlueControl is intended for

daily use. The exact usage time is stated in chapter ‘Using your Philips BlueControl’, section ‘Treatment schedule’.

The Philips BlueControl complies with the standard of basic safety for medical devices (IEC60601-1) and with the relevant collateral and particular standards for non-laser light source medical equipment for home use: EN 60601-1[1], EN 60601-1-11 [3], EN 60601-2-57 [2], and EN 60601-1-2 [4]. Regarding electromagnetic compatibility (EMC) and electromagnetic fields (EMF), the device should be kept away from radio frequency (RF) equipment to avoid interference.

Compliance

Page 10 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 10 · Zum Vergrößern klicken
Seite 10

General description (Fig. 1)

1 Philips BlueControl 2 On/off button and LED indicator 3 Micro USB socket 4 Sensor 5 Fixation strap 6 Short sling for lower arm or ankle 7 Medium-long sling for upper arm or knee 8 Long sling for leg 9 Adapter housing 10 European plug 11 UK plug 12 USB cable 13 Carry case

Fully charge the Philips BlueControl before you use it for the first time. When fully charged, the Philips BlueControl has enough power for at least four treatments. It is recommended to charge the Philips BlueControl every day. You can charge the Philips BlueControl with the adapter and USB cable supplied. The adapter and USB cable have an expected life time of at least 3 years in normal intended operation. The device has a useful life of at least 3 years if used in accordance with its intended use. When the BlueControl is connected to the charger and in charging mode, the charger PR3089 is to be considered as a part of the medical system.

Charging

Page 11 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 11 · Zum Vergrößern klicken
Seite 11

Charging with the adapter

It takes approximately 3 hours to fully charge the Philips BlueControl.

1 Put the European or UK mains plug in the

adapter and lock it into place.

2 Insert the standard USB plug into the socket

on the adapter.

3 Insert the adapter into the wall socket

(100V-240V).

4 Insert the micro USB plug into the socket on

the Philips BlueControl. , When the Philips BlueControl is connected to

the mains, it beeps once and the LED indicator starts flashing green slowly to indicate that charging has started.

5 When the Philips BlueControl is fully charged,

the LED indicator lights up solid green.

6 Remove the adapter from the wall socket and

pull the micro USB plug out of the micro USB socket on the Philips BlueControl.

Page 12 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 12 · Zum Vergrößern klicken
Seite 12

Using your Philips BlueControl

Always stick to the recommended treatment

schedule. Do not treat each plaque more than once a day. The Philips BlueControl has been designed for daily use on psoriasis vulgaris plaques. We recommend treating single, non-overlapping psoriasis vulgaris plaques only once a day. A single treatment takes approximately 30 minutes, but can be extended to 40 minutes depending on your skin sensitivity and possible treatment pauses during treatment. For example, if the infrared sensor senses a too high skin temperature, the treatment is briefly paused for safety reasons. Treatment resumes automatically when the skin has cooled down. Following this treatment advice ensures that you do not exceed the daily light dose of 90 J/cm² per plaque. Blue light treatment can be combined with vitamin D creams. Apply the cream after the treatment. For other combination treatments with blue light, please consult your doctor. We do not recommend using topical medication, creams or lotions immediately before and during treatment with the Philips BlueControl. In case of unpleasant effects such as excessive, non-resolving skin redness, worsening of plaques or pain, stop the therapy immediately and consult your doctor if necessary. It is possible that you experience slight tanning of the area treated. This should diminish within a few days after the therapy has been stopped. A temporary increased redness of the treated area after treatment is normal but should also diminish.

Treatment schedule

Page 13 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 13 · Zum Vergrößern klicken
Seite 13

Preparing the Philips BlueControl for use

To place the Philips BlueControl in the fixation strap and to position it correctly on your body, follow the steps below. The fixation strap has an expected lifetime of at least 1 year if used in accordance with its intended use. There are three slings: a short sling for lower arm or ankle, a medium-long sling for upper arm or knee, and a long sling for the leg.

1 Place the Philips BlueControl in the fixation

strap.

2 Select the suitable sling for the area to be

treated on the arm or the leg.

3 To attach the selected sling to the fixation

strap, pull one end of the sling through one ring of the fixation strap (1) and fasten it with the Velcro fastener (2).

4 Remove clothing from the area to be treated.

5 Position the fixation strap on top of the

psoriasis plaque on your arm or leg (1). Wrap the sling around your arm or leg (2).

Page 14 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 14 · Zum Vergrößern klicken
Seite 14

6 Pull the sling through the other ring (1).

Then wrap the sling around your arm or leg once more and fasten it with the Velcro fastener (2).

1 Press the on/off button to switch on the Philips

BlueControl.

Do not intentionally touch the sensor in the centre of the Philips BlueControl when it is switched on.

Do not cover the Philips BlueControl with other textile materials than the fixation strap when it is switched on.

2 The Philips BlueControl flashes blue to indicate

that it is ready for treatment. The treatment starts soon after the sensor detects the skin to be treated. , The LED indicator lights up solid blue and a

sequence of two tones indicates the treatment is in progress.

3 The Philips BlueControl automatically switches

off after the treatment time (approximately 30 minutes) has elapsed.

Treatment procedure

Page 15 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 15 · Zum Vergrößern klicken
Seite 15

1 If you want to interrupt the treatment briefly,

simply remove the Philips BlueControl or press the on/off button to switch it off.

Note: If you remove the Philips BlueControl or press the on/off button to stop treatment before the treatment time has elapsed and you do not resume the treatment within 2 hours, the timer automatically resets. If you resume the treatment within 2 hours, the countdown of the treatment time will continue where it left off. When a treatment is resumed, there will be no sequence of 2 tones.

Treatment ends automatically after the treatment time has elapsed, unless you remove the Philips BlueControl or press the on/off button to stop treatment earlier.

1 Open the Velcro fastener of the sling at one

end (1) and pull the strap out of the ring of the fixation strap (2).

2 Unwrap the sling (1) and remove the fixation

strap from your psoriasis plaque (2).

3 Recharge the Philips BlueControl. You can take

the device out of the fixation strap or charge it while it stays in the fixation strap.

Interrupting treatment · After treatment

Page 16 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 16 · Zum Vergrößern klicken
Seite 16

Light and sound signals during use

Overheating signal Overheating of the device.

1 If the device measures a too high device

temperature, the Philips BlueControl switches off for safety reasons. , The LED indicator lights up solid orange and

a long 3-second tone indicates that the Philips BlueControl switches off.

2 If you try to restart the Philips BlueControl

before it has cooled down, the LED indicator flashes orange for 5 seconds. Cooling down may take several minutes. Overheating of the skin.

1 If the device measures a too high skin

temperature, the Philips BlueControl temporarily switches off for safety reasons. , The LED indicator flashes blue slowly until the

skin temperature has cooled down, the Philips BlueControl switches on again automatically.

Battery level signals When you press the on/off button and the LED indicator lights up solid red and you hear 3 beeps, the battery of the Philips BlueControl is empty.

1 You have to charge the battery before you

can start a new treatment. Charge for at least 45 minutes to be able to complete one full treatment.

Page 17 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 17 · Zum Vergrößern klicken
Seite 17

Do not immerse the Philips BlueControl in water or rinse it under the tap.

Always remove the Philips BlueControl from the fixation strap before you put the fixation strap in the washing machine to clean it.

1 Remove the Philips Blue Control from the

fixation strap.

2 Clean the Philips BlueControl with a damp

cloth.

3 Clean the sensor with alcohol and a cotton

bud at an ambient temperature once a week.

4 The fixation strap and the slings can be washed

in the washing machine.

Cleaning

Page 18 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 18 · Zum Vergrößern klicken
Seite 18

The device comes with a carry case with storage spaces for all parts.

1 Use the storage case to store the device and

its parts if you do not use it.

2 If you want to take the device with you to

work or while travelling, we advise you to put it in the carry case for extra protection.

This chapter summarises the most common problems you could encounter with the Philips BlueControl. If you are unable to solve the problem with the information below, contact the Philips Consumer Care Centre.

Problem Possible cause Solution

I cannot switch on the Philips BlueControl even though it is fully charged.

The sensor is dirty.

Clean the sensor with alcohol and a cotton bud (see chapter ‘Cleaning’).

The Philips BlueControl suddenly switches off during treatment.

The preset time has elapsed.

The Philips BlueControl has been programmed to switch off automatically after the treatment time has elapsed.

Storage · Troubleshooting

Page 19 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 19 · Zum Vergrößern klicken
Seite 19

Problem Possible cause Solution

The sensor is blocked.

Check the position of the Philips BlueControl in the fixation strap. Make sure the material of the fixation strap or clothing does not cover the sensor. If the sensor is not covered but the Philips BlueControl still switches off, the skin temperature is too high. The Philips BlueControl will switch on automatically when the skin has cooled down.

The rechargeable battery is empty.

The LED indicator flashes red. Charge the Philips BlueControl (see chapter ‘Charging’).

The Philips BlueControl suddenly switches off with a long beep during treatment and the LED indicator lights up solid orange.

The temperature of the Philips BlueControl itself is too high and the Philips BlueControl switched off for safety reasons.

Let the Philips BlueControl cool down for 10 minutes. Put the Philips BlueControl back onto your skin and press the on/off button to resume treatment.

The Philips BlueControl suddenly interrupts the treatment and slowly flashes blue.

The device measured a too high skin temperature and paused the treatment to allow the skin to cool down.

No action required. The treatment restarts automatically after the device measures a skin temperature in the safe range.

Page 20 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 20 · Zum Vergrößern klicken
Seite 20

Problem Possible cause Solution

The Philips BlueControl is switched off with a long beep and the LED indicator flashes orange.

The Philips BlueControl was interrupted too many times during treatment, for instance because the sensor sensed a too high skin temperature or because maximum treatment time of 40 minutes was exceeded.

If this happens a few times, contact Philips.

The LED indicator lights up solid orange when I press the on/off button.

The device temperature is too high and the Philips BlueControl switched off for safety reasons.

Let the Philips BlueControl cool down for 10 minutes. Put the Philips BlueControl back onto your skin and press the on/off button to resume treatment.

The LED indicator lights up solid red for 5 seconds and the Philips BlueControl beeps 3 times when I press the on/off button.

The rechargeable battery is empty.

Charge the Philips BlueControl (see chapter ‘Charging’).

The adapter becomes warm during charging.

This is normal. No action required.

Page 21 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 21 · Zum Vergrößern klicken
Seite 21

Problem Possible cause Solution

The LED indicator does not flash green when the micro USB plug is inserted into the micro USB socket of the Philips BlueControl.

The adapter is not inserted or not inserted properly into the wall socket.

Insert the adapter into the wall socket properly.

The standard USB plug is not inserted or inserted properly into the adapter.

Insert the standard USB plug into the adapter properly.

The wall socket is not live.

Connect another appliance to the same wall socket to check if the wall socket is live. If the wall socket is live, but the Philips BlueControl does not charge, contact Philips.

The Philips BlueControl becomes warm during use.

This is normal. No action required.

Page 22 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 22 · Zum Vergrößern klicken
Seite 22

If you need service or information or if you have a problem, please contact the Philips Consumer Care Centre at telephone number 00800-7445 4778.

Guarantee restrictions The guarantee does not cover standard wear and tear. The guarantee becomes invalid if the Philips BlueControl is not used according to the instructions in this user manual.

Manufacturer’s legal address Philips Electronics Nederland BV Philips Light & Health High Tech Campus 5 5656AE Eindhoven The Netherlands

- This symbol means that this product shall not

be disposed of with normal household waste (2012/19/EU).

- This symbol means that this product contains a built-

in rechargeable battery which shall not be disposed of with normal household waste (2006/66/EC). We strongly advise you to take your product to an official collection point or a Philips service centre to have a professional remove the rechargeable battery. - Follow your country’s rules for the separate

collection of electrical and electronic products and rechargeable batteries. Correct disposal helps prevent negative consequences for the environment and human health.

Guarantee and support · Recycling

Page 23 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 23 · Zum Vergrößern klicken
Seite 23

Removing the rechargeable battery

This procedure is irreversible. You cannot use the device anymore after this procedure.

1 Make sure the rechargeable battery is empty.

2 Open the device by removing the transparent

lower part from the metal upper part.

3 Remove the battery with appropriate tools.

Philips BlueControl is certified as medical non-laser light source equipment. While in operation it generates blue light with the following specification:

Class Medical device Class IIa

Risk Group 1 according EN 60601-2-57, meaning no risk in normal intended use.

Show 6 more labels / short text on this page
Specifications · Device PSD1211 · Voltage 100-240 V · Frequency 50-60 Hz · Input 7 W · Optical output classification
Page 24 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 24 · Zum Vergrößern klicken
Seite 24

Power density 200 mW/cm² (peak), 40 mW/cm² (average), maximum variation across the treatment area is

Max. daily dose per plaque 90 J/cm²

Battery type 3.7V /rated capacity 6.1 Whr Lithium-ion battery

Adapter with USB cable PR3089

Input 100-240 V AC / 50-60Hz

Output 5V DC / 7 W

Fabric composition 66 % polyamide; 20 % polyester; 10 % elastane; 4 % polyurethane

Temperature from +10°C to +35°C

Relative humidity from 30% to 90%

Temperature from -20°C to +35°C

Relative humidity from 30% to 90% (no condensation)

Show 4 more labels / short text on this page
Device PSD1211 · Fixation strap PSS1210 · Operating conditions · Storage conditions
Page 25 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 25 · Zum Vergrößern klicken
Seite 25

Symbols on device There are several safety warning labels on the device, the fixation strap and in the user manual. Not following these warnings may result in one or more of the following hazards: electrical shock, skin burn, retinal damage and/or fire.

- This yellow/black symbol on the device label is a

Read the user manual before you start using the device.

- This yellow/black symbol on the device label

means: Do not stare at the light source. Risk Group 1 product (IEC60601-2-57:2011).

- This symbol meansPhilips BlueControl is specified

as applied part type BF. B indicates that it is used on the Body and F indicates that it is Floating from (not connected to) the mains voltage.

- This symbol means: Conforms to EC Directives.

CE stands for ‘Conformité Européenne’.

Explanation of symbols

Page 26 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 26 · Zum Vergrößern klicken
Seite 26

- This symbol means ‘Manufactured by’ and provides

the address of the legal manufacturer.

- This symbol means: Made in the Netherlands.

- This symbol indicates input for power supply.

PR3089 below this symbol means that the device may only be charged with the adapter that is supplied in the package. Usage of other adapters may not be safe and could lead to electrical shock. The adapter has the following electrical specification: Input 100-240V AC / 50-60 Hz, output 5V DC / 7 W. When charging the device, make sure that the adapter and the device are positioned in such a way that the adapter and device can always be disconnected easily. - This symbol means: keep dry.

- This symbol indicates the serial number of the

device.

Page 27 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 27 · Zum Vergrößern klicken
Seite 27

- This symbol indicates the USB connector.

- This symbol means that the device uses LI-ION

rechargeable batteries.

- This symbol indicates that the adapter is double

insulated (Class II).

- This symbol indicates that the adapter may only be

used indoors.

Symbols on fixation strap

- This symbol meansWash at a maximum

temperature of 60°C.

Symbols on adapter

Page 28 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 28 · Zum Vergrößern klicken
Seite 28

- This symbol means: Do not bleach.

- This symbol means: Do not tumble-dry.

- This symbol means: Do not iron.

- This symbol means: Do not dry clean.

- This symbol means: Made in China.

Page 29 of the Philips PSD1211 user manual — - To prevent damage to the drum of the
Seite 29 · Zum Vergrößern klicken
Seite 29

- This symbol means: Read the user manual.

- This symbol indicates the batch code.

Reparatur

Fehlerbehebung

Häufige Probleme, wahrscheinliche Ursachen und Lösungen.

ProblemMögliche UrsacheAbhilfe
The sensor is blocked.Check the position of the Philips BlueControl in the fxi ation strap. Make sure the material of the fxi ation strap or clothing does not cover the sensor. If the sensor is not covered but the Philips BlueControl still switches off, the skin temperature is too high. The Philips BlueControl will switch on automatically when the skin has cooled down. p.19
The rechargeable battery is empty.The LED indicator flashes red. Charge the Philips BlueControl (see chapter ‘Charging’). p.19
The temperature of the Philips BlueControl itself is too high and the Philips BlueControl switched off for safety reasons.Let the Philips BlueControl cool down for 10 minutes. Put the Philips BlueControl back onto your skin and press the on/off button to resume treatment. p.19
The device measured a too high skin temperature and paused the treatment to allow the skin to cool down.No action required. The treatment restarts automatically after the device measures a skin temperature in the safe range. p.19
The Philips BlueControl was interrupted too many times during treatment, for instance because the sensor sensed a too high skin temperature or because maximum treatment time of 40 minutes was exceeded.If this happens a few times, contact Philips. p.20
The device temperature is too high and the Philips BlueControl switched off for safety reasons.Let the Philips BlueControl cool down for 10 minutes. Put the Philips BlueControl back onto your skin and press the on/off button to resume treatment. p.20
The rechargeable battery is empty.Charge the Philips BlueControl (see chapter ‘Charging’). p.20
This is normal.No action required. p.20
The adapter is not inserted or not inserted properly into the wall socket.Insert the adapter into the wall socket properly. p.21
The standard USB plug is not inserted or inserted properly into the adapter.Insert the standard USB plug into the adapter properly. p.21
The wall socket is not live.Connect another appliance to the same wall socket to check if the wall socket is live. If the wall socket is live, but the Philips BlueControl does not charge, contact Philips. p.21

Frage zu Philips PSD1211 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Philips PSD1211

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.