English Page 4 • Keep pages 3 and 46 open when reading these operating instructions.
Français Page 8 • Pour le mode d'emploi dépliez les pages 3 et 46.
Deutsch Seite 11 • Schlagen Sie beim Lesen der Gebrauchsanweisung Seiten 3 und 46 auf.
Nederlands Pagina 14 • Sla bij het lezen van de gebruiksaanwijzing de pagina's 3 en 46 op.
Italiano Pagina 17 • Prima di usare l'apparecchio, aprite la pagina 3 e là paginà 46 e leggete attentamente le istruzioni per l'uso.
Español Página 20 • Desplegar la página 3 y la página 46 al leer las instrucciones de manejo.
Português Página 23 • Durante a leitura do modo de emprêgo, desdobre e verifique a pág. 3 e pág. 46.
Dansk Side 26 • Hold side 3 og side 46 opslået mens De læser brugsanvisningen.
Norsk Side 29 • Slå opp på side 3 og side 46 før De leser videre.
Svenska Sid 32 • Ha sidan 3 och sidan 46 utvikt när ni läser bruksanvisningen.
Suomi Sivu 35 • Pidä sivut 3 ja 46 auki samalla kun luet käyttöohjetta.
Ελληνικά Σελίδα 38 • Για τις δηγίες ρήσεως, ανίτε τις σελίδες 3 και 46.



English for the Hepa filters. Moreover, their overall performance will remain virtually constant over the life of the filters.
❸Hepa filter The last filter is the Hepa filter. This filter takes out all the remaining smaller particles. The filter is made from glass fibres closely matted such that particles cannot pass through. Similar filters are used in most hospital operating rooms.
To prevent respiratory problems, clean air in your home is a basic requirement. Your Philips Air Cleaner helps you to purify the air effectively by catching up to 99% of the airborne particles. This includes allergens such as house dust and pollen as well as viruses and bacteria.
None of these particles are useful for the human body. Some of them are actually very harmful and may cause serious complaints and diseases. The particles vary in size from 0.1 to 100 micron (1 micron = 0.001 mm).
How does the Philips Air Cleaner work?
The Air Cleaner takes air from near the floor where particles concentrations are greatest and after cleaning blows it towards the ceiling.
To remove even the smallest particles from the air, the appliance employs a unique 3-stage Air Cleaner filter:
❶Pre-filter The Pre-filter catches the larger dust particles floating in the air, such as fluff and hairs.
Which size of Air Cleaner is suitable?
❷Rota filter The rotating disc filter takes out the particles of 2 micron and more (e.g. pollen). On entering one of the channels of the filter a particle is centrifuged against the side of this channel. The air will pass through the channel but the particle remains stuck against the channel wall. This unique and patented filter ensures a long life
Positioning · Additional measures

How to clean or replace the filters
Removing the filters - Set the speed selector to position O (fig. 9). - Remove the mains plug from the wall socket. - Remove the front cover (fig. 10). - Remove the Hepa filters (fig. 11). - Turn the Hepa filters. - Compare the colour of their undersides with
General description (fig. 8)
A Air inlets (3) B Pre-filter C Rota filter D Fixing nut for Rota filter E Hepa filters
the colours on the “Filter full” indicator (fig. 12). - Replace the Hepa filters as soon as the colour
of their undersides corresponds to the darkest grey on the “Filter full” indicator (fig. 13). - Remove the Pre-filter (fig. 14). - Remove the Rota filter (fig. 15). To place the filters back reverse this process.
type HR 4320: 2 filters type HR 4330: 3 filters F Pilot light "On" G Air outlet H Speed control
Safety lock The front cover has a safety lock which prevents you from opening the cover whilst the Air Cleaner is switched on. The safety lock also prevents you from switching on if the front cover is removed.
How to use · O = off

Cleaning the Pre-filter and the Rota filter
- Wash (fig. 16) or vacuum clean the Pre-filter.
You can remove fluff or hairs e.g. using a soft brush. - Wash (fig. 17) or vacuum clean the Rota filter.
If washed with a detergent, rinse the filters with clean warm water (fig. 18). Allow the filters to air-dry thoroughly (fig. 19) before reassembly. The Rota filter can also be washed in a dishwasher.
Replacement Hepa filters New Hepa filters are available at your dealer under number HR 4920.
Automatic overheating safety device
To prevent damage and reduce safety risks the overheating safety device switches off the fan motor if it becomes too hot. To indicate that the appliance is still in switched- on position and connected to the mains, the pilot light will remain on.
If this happens: - Set the speed selector to position O (= Off). - Remove the mains plug from the wall socket.
(The pilot light goes out.) - Wait for the motor to cool down (approx.
15 minutes). - Open the appliance. Check that the filters are
not blocked and that nothing is obstructing the airflow. - Check that the Rota filter can rotate freely if
moved by hand (fig. 20). - Close the appliance. Put the mains plug back
into the wall socket and switch on.
If the automatic overheating device is activated repeatedly, it is advisable to take the appliance to your dealer for technical inspection.