DE
Philips logo
Offizielle Bedienungsanleitung

Philips DE5205

214 Seiten·3 MB·Luftbefeuchter & -entfeuchter·PDF·ENJA
Philips DE5205
Inhaltsverzeichnis 57 Abschnitte DE5205 · EN User manual 1 · FR Mode d’emploi 105 · DA Brugervejledning 19 · … AnzeigenAusblenden
DE5205p.1EN User manual 1p.1FR Mode d’emploi 105p.1DA Brugervejledning 19p.1IT Manuale utente 129p.1DE Benutzerhandbuch 39p.1NL Gebruiksaanwijzing 151p.1ES Manual del usuario 63p.1NO Brukerhåndbok 173p.1FI Käyttöopas 85p.1SV Användarhandbok 193p.1Contentsp.31 Importantp.4Safetyp.4Dangerp.4Warningp.4Cautionp.5the dehumidifier directly atp.6condensation inside the dehumidifier. • To prevent interference,p.7by pulling the power cord. • This appliance is notp.7dehumidifier in a room with major temperature changes, as this may causep.72 Your Philips 2-in-1 Air Dehumidifier and Purifierp.8Product Overview (fig. a )p.8Controls Overview (fig. b )p.83 Getting startedp.9Positioning the dehumidifierp.9Installing the filterp.94 Using the dehumidifierp.10The air quality lightp.10Setting the humidity levelp.10Turning on and offp.10Changing the fan speedp.11Using the purification only modep.11Setting the Timerp.12Using the swing functionp.12Defrosting the dehumidifierp.125 Draining the dehumidifierp.13Emptying the water tankp.13Setting the child lockp.13Using the light on/off functionp.13Using the continuous drainagep.136 Cleaningp.14Cleaning the body of the dehumidifierp.14Cleaning the water tankp.15Cleaning the pre-filterp.157 Replacing the filterp.16Cleaning the air quality sensorp.16Filter replacement indicatorp.16Replacing the filterp.168 Storagep.179 Troubleshootingp.1810 Guarantee and servicep.20Order parts or accessoriesp.20HFC Informationp.2011 Noticesp.20Electromagnetic fields (EMF)p.20Recyclingp.20
Page 1 of the Philips DE5205 user manual — ES Manual del usuario 63
Seite 1 · Zum Vergrößern klicken
Seite 1
Philips DE5205 — DE5205 diagram (page 1)
Abb. 1
Philips DE5205 — DE5205 diagram (page 1)
Abb. 2
Philips DE5205 — DE5205 diagram (page 1)
Abb. 3
Philips DE5205 — DE5205 diagram (page 1)
Abb. 4

DE5205

Philips DE5205 — DE5205 diagram (page 1)
Abb. 5
Philips DE5205 — DE5205 diagram (page 1)
Abb. 6

a b c d e f g h i

EN User manual 1

FR Mode d’emploi 105

DA Brugervejledning 19

IT Manuale utente 129

DE Benutzerhandbuch 39

NL Gebruiksaanwijzing 151

© 2016 Koninklijke Philips N.V. All rights reserved.

ES Manual del usuario 63

NO Brukerhåndbok 173

FI Käyttöopas 85

SV Användarhandbok 193

Show 7 more labels / short text on this page
a · b · d · e · f · 4241 210 92712 · j k
Page 2 of the Philips DE5205 user manual — DE5205
Seite 2 · Zum Vergrößern klicken
Seite 2
Philips DE5205 — DE5205 diagram (page 2)
Abb. 7
Philips DE5205 — DE5205 diagram (page 2)
Abb. 8
Page 3 of the Philips DE5205 user manual — Inhaltsverzeichnis
Seite 3 · Inhalt
Inhalt

Inhalt

DE5205p.1EN User manual 1p.1FR Mode d’emploi 105p.1DA Brugervejledning 19p.1IT Manuale utente 129p.1DE Benutzerhandbuch 39p.1NL Gebruiksaanwijzing 151p.1ES Manual del usuario 63p.1NO Brukerhåndbok 173p.1FI Käyttöopas 85p.1SV Användarhandbok 193p.1Contentsp.31 Importantp.4Safetyp.4Dangerp.4Warningp.4Cautionp.5the dehumidifier directly atp.6condensation inside the dehumidifier. • To prevent interference,p.7by pulling the power cord. • This appliance is notp.7dehumidifier in a room with major temperature changes, as this may causep.72 Your Philips 2-in-1 Air Dehumidifier and Purifierp.8Product Overview (fig. a )p.8Controls Overview (fig. b )p.83 Getting startedp.9Positioning the dehumidifierp.9Installing the filterp.94 Using the dehumidifierp.10The air quality lightp.10Setting the humidity levelp.10Turning on and offp.10Changing the fan speedp.11Using the purification only modep.11Setting the Timerp.12Using the swing functionp.12Defrosting the dehumidifierp.125 Draining the dehumidifierp.13Emptying the water tankp.13Setting the child lockp.13Using the light on/off functionp.13Using the continuous drainagep.136 Cleaningp.14Cleaning the body of the dehumidifierp.14Cleaning the water tankp.15Cleaning the pre-filterp.157 Replacing the filterp.16Cleaning the air quality sensorp.16Filter replacement indicatorp.16Replacing the filterp.168 Storagep.179 Troubleshootingp.1810 Guarantee and servicep.20Order parts or accessoriesp.20HFC Informationp.2011 Noticesp.20Electromagnetic fields (EMF)p.20Recyclingp.20
Page 4 of the Philips DE5205 user manual — Warning
Seite 4 · Zum Vergrößern klicken
Seite 4

1 Important

fire hazard and/ or electric shock.

  • If the power cord is

damaged, you must have it replaced by Philips, a service center authorized by Philips, or similarly qualified persons in order to avoid a hazard.

Safety

Read this user manual carefully before you use the dehumidifier, and save it for future reference.

Danger

  • Do not spray any
  • Do not use the appliance

flammable materials such as insecticides or fragrance around the dehumidifier to avoid electric shock and/or a fire hazard.

if the plug, the power cord, or the appliance itself is damaged.

  • This appliance is not

intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

  • Do not drink the

accumulated water, use it to feed animals, nor to water plants. Empty the water tank, and pour the water down the drain.

Warning

  • Check if the voltage

indicated on the bottom or indicated at the rear of the appliance corresponds to the local power voltage before you connect the appliance.

  • Children should be

supervised to ensure that they do not play with the appliance.

  • Connect the dehumidifier
  • Do not start or stop the

to the power socket exclusively, and do not connect it through an extension cord to prevent

dehumidifier by plugging and unplugging the power cord.

Page 5 of the Philips DE5205 user manual — Caution
Seite 5 · Zum Vergrößern klicken
Seite 5
  • Do not block the air inlet
  • Do not use this

and outlet, e.g. by placing items on the air outlet or in front of the air inlet.

dehumidifier when you have used indoor smoke- type insect repellents or in places with oily residues, burning incense, or chemical fumes.

  • Do not insert your fingers

or objects into the air inlet and outlet to prevent physical injury or product malfunction.

  • Do not operate or store the

dehumidifier under direct sunlight.

Caution

  • Do not use the
  • Do not turn the appliance

dehumidifier near gas appliances, heating devices or fireplaces.

on and off frequently.

  • If the power socket used

to power the dehumidifier has poor connections, the plug of the dehumidifier becomes hot. Make sure you plug the dehumidifier into properly connected power socket.

  • Do not use the

dehumidifier in a bathroom or other places where it is likely to come in contact with water, or wash it with water.

  • When you use the
  • Always place and use the

dehumidifier for drying laundry, hang your clothes from a distance where water droplets will not drip onto the dehumidifier.

dehumidifier on a dry, stable, level, and horizontal surface.

  • Leave at least 40 cm free

space behind and on both sides of the dehumidifier and leave at least 60 cm free space above it. Insufficient ventilation may cause overheating or fire hazard.

  • The dehumidifier is only

intended for household use under normal operating conditions (5°C - 35°C).

  • Do not use the

dehumidifier in a room with major temperature changes.

Page 6 of the Philips DE5205 user manual — the dehumidifier directly at
Seite 6 · Zum Vergrößern klicken
Seite 6
  • Run the power cord under
  • Do not stand on, sit

carpeting, rugs, or runners. Arrange the cord away from areas where it may be tripped over.

on, or lean against the dehumidifier. This may cause the dehumidifier to tip over causing injury.

  • Make sure the filters and
  • Do not remove or dismantle

the water tank are properly installed before you switch on the dehumidifier.

the float in the tank; otherwise, the dehumidifier cannot detect when the tank is full and could result in water leakage.

  • Do not touch the swing

louver.

  • Avoid knocking against the
  • Do not use detergents,

dehumidifier (the air inlet and outlet in particular) with hard objects.

cleaning agents, abrasive powders, chemically treated dusters, gasoline, benzene, thinners or other solvents, as they can damage the dehumidifier or the water tank. This may result in water leakage.

  • Always unplug the

dehumidifier after use and before you move or clean it.

  • Power off and unplug

the dehumidifier before draining the water from the tank. Otherwise, this may result in water leakage.

  • Mildew may form in the

water tank, clean it every week with tap water. Then, wipe with a soft, dry cloth.

  • Always move the

dehumidifier in an upright position with handle, and do not carry it horizontally.

  • If you do not use the

dehumidifier for an extended period of time, make sure all parts are clean and dry.

  • Do not drop the

dehumidifier as this may cause personal injury, and damage to the floor or household items as a result of water spillage.

  • Do not use the dehumidifier

for food preservation, art or scientific works.

  • Do not point the airflow of
  • Do not place anything on

the dehumidifier directly at

top of the dehumidifier.

Page 7 of the Philips DE5205 user manual — dehumidifier in a room with major temperature changes, as this may cause
Seite 7 · Zum Vergrößern klicken
Seite 7

the body for a prolonged period of time, especially where there is someone who is unable to adjust the humidity. For instance: infant, child, or elderly person. This may harm the physical condition and lead to dehydration.

condensation inside the dehumidifier. • To prevent interference,

place the appliance at least 2m away from electrical appliances that use airborne radio waves such as TVs, radios, and radio- controlled clocks. • The appliance does not

remove carbon monoxide (CO) or radon (Rn). It cannot be used a safety device in case of accidents with combustion processes and hazardous chemicals. • Never move the appliance

  • Use the dehumidifier with

appliance directly below an air conditioner to prevent condensation from dripping onto the appliance which will cause short circuit and leakage of electricity. • Only use the original

by pulling the power cord. • This appliance is not

a substitute for proper ventilation, regular vacuum cleaning, or use of an extractor hood or fan while cooking. • If the appliance is not used

Philips filters specially intended for this appliance. Do not use any other filters. • Burning the filter may

for a long period of time, remove the filter from the dehumidifier and store it separately in a cool, dry place. • Do not sit or stand on the

cause irreversible damage to humans or other creatures. Do not use the filter as fuel or for similar purposes. • Always lift or move the

appliance. The appliance is equipped with unilateral rotating wheels. Sitting or standing on the appliance may lead to potential injury. Fuse Specification: T2.0A 250V T5.0A 250V

appliance by the handle at the top of the appliance. • Do not use the

dehumidifier in a room with major temperature changes, as this may cause

Page 8 of the Philips DE5205 user manual — Controls Overview (fig. b )
Seite 8 · Zum Vergrößern klicken
Seite 8

2 Your Philips 2-in-1 Air Dehumidifier and Purifier

Congratulations on your purchase, and welcome to Philips!

To fully benefit from the support that Philips offers, register your product at www.Philips.com/welcome

Product Overview (fig. a )

aHandlehUnilateral rotating wheels bLouveriDisplay panel cAir outletjContinuous drainage outlet dAir quality sensorkPower cord eAir quality lightlRear cover with air inlet fWater tankmPre-filter gHosenNanoProtect filter Series 1 (FY1119)
Philips DE5205 — Product Overview (fig. a ) diagram (page 8)
Abb. 9 · Product Overview (fig. a )

Controls Overview (fig. b )

aOn/off buttonfHumidity level setting button bChild lock buttongLight on/off button cAuto swing buttonhPurification ONLY button dFan speed buttoniTimer button eDisplay screen
Philips DE5205 — Controls Overview (fig. b ) diagram (page 8)
Abb. 10 · Controls Overview (fig. b )
Filter replacement alertAuto mode icon Auto defrosting indicatorLaundry drying mode icon Water tank full alertContinuous mode icon Pre-filter cleaning alertPurification ONLY mode icon
Philips DE5205 — Controls Overview (fig. b ) diagram (page 8)
Abb. 11 · Controls Overview (fig. b )

Display panel

Page 9 of the Philips DE5205 user manual — Installing the filter
Seite 9 · Zum Vergrößern klicken
Seite 9

3 Getting started

Positioning the dehumidifier

To increase the dehumidifying effectiveness, position the dehumidifier in a location that can draw the most air.

Installing the filter

  • Make sure that the appliance is

unplugged before installing the filter.

  • When the dehumidifier is operating,

do not open exterior doors or windows.

Before using the appliance, remove all packaging materials from the filter and place the filter into the appliance as described as follows. 1 Pull the top part of the rear panel to remove it from the appliance (fig.c). 2 Take out the filter and the pre-filter (fig.d). 3 Remove all packaging materials from the filter (fig.e). 4 Place the filter into the dehumidifier and then the pre-filter (fig.f).

  • Make sure that the filter and the

pre-filter are properly attached to the dehumidifier.

5 Reattach the rear cover by pressing the bottom part of the rear cover onto the appliance first (1). Then, gently push the rear cover against the body of the appliance (2) (fig.g). 6 Wash your hands thoroughly after installing filters.

Page 10 of the Philips DE5205 user manual — Turning on and off
Seite 10 · Zum Vergrößern klicken
Seite 10

4 Using the dehumidifier

2 Touch the button once to turn on the appliance (fig.h).

» The current humidity level is

displayed on the screen.

» After measuring the air quality for a short time, the air quality sensor automatically selects the color of the air quality light.

The air quality light

Color of the air quality lightAir quality level BlueGood Blue-violetFair Red-purpleUnhealthy RedVery unhealthy

» The dehumidifier goes to combi

AUTO mode. 3 Touch and hold for 3 seconds to turn off the appliance.

Setting the humidity level

The air quality light automatically goes on when the appliance is switched on, and lights up all colors in sequence. In a short time the air quality sensors select the color that corresponds to the surrounding air quality of airborne particles.

You can set the desired humidity level to 40, 50, 60, 70, or 80 percent. 1 Touch the button one or more times to set the desired humidity level, and the humidity indicator lights up (fig.i).

Turning on and off

  • When the humidity is decreased to
  • For optimum performance, close

the selected level, the dehumidifier automatically stops dehumidifying the air, but the fan will continue working. • If you do not set the humidity level,

doors and windows. • Keep curtains away from the air

inlet or air outlet. • For optimum dehumidification

efficiency, place the dehumidifier in a flat, stable surface. • Before turning on the dehumidifier,

the default humidifier is 60%.

  • You can touch the button for 5 seconds to display the current ambient temperature.

check if the power voltage corresponds to the voltage printed on the dehumidifier.

1 Put the plug of the dehumidifier in the wall outlet.

  • A comfortable humidity level is from

40RH% to 60RH%.

» The dehumidifier beeps.

Page 11 of the Philips DE5205 user manual — Using the purification only mode
Seite 11 · Zum Vergrößern klicken
Seite 11
Philips DE5205 — Changing the fan speed diagram (page 11)
Abb. 12 · Changing the fan speed

In continuous mode, the appliance constantly works with the optimal dehumidifying settings. 1 Touch the button repeatedly to select the continuous mode (fig.j).

dehumidifier directly at the body for a prolonged period of time, especially where there is someone who is unable to adjust the humidity. • When you use the dehumidifier

» The and display on the screen.

for laundry drying, hang your clothes from a distance where water droplets will not drip onto the dehumidifier. • Make sure the air inlet and outlet

Changing the fan speed

You can select the desired fan speed (Auto,1, 2 ,3 and 4), or clothes dry mode.

are not blocked by the clothes. • Make sure that you dry the clothes

on a safe and secure place from dropping to block the air inlet and outlet.

  • Touch the fan speed button repeatedly to select the auto mode (fig. k ).
Philips DE5205 — Changing the fan speed diagram (page 11)
Abb. 13 · Changing the fan speed

directly onto the clothes to dry your clothes more efficiently.

  • You can adjust the humidity settings

manually by touching the button.

Using the purification only mode

  • Touch the fan speed button repeatedly to select the fan speed you need (fig. l ).

The appliance can be used in purification only mode. 1 Touch the button to access purification only mode (fig.n).

» The appliance operates under

  • Touch the button until is displayed to select the laundry drying mode (fig. m ).

auto mode by default.

» The dehumidifier will stop dehumidifying the air.

» The dehumidifier goes to

» The and the display on the screen.

laundry drying mode.

» The dehumidifier operates under

the highest fan speed.

» and display on the screen.

Show 4 more labels / short text on this page
Continuous mode · Auto · Manual · Laundry drying mode
Page 12 of the Philips DE5205 user manual — Using the swing function
Seite 12 · Zum Vergrößern klicken
Seite 12

2 Touch the fan speed button to select the desired fan speed (fig.o).

Setting the Timer

» The fan speed and display on the screen. 3 Touch the button again to exit the purification only mode.

With the timer function, you can let the dehumidifier operate for a set number of hours. When the set time has elapsed, the dehumidifier automatically turns off. The timer is available from 1 to 9 hours. 1 Touch the button to activate the timer (fig.q). 2 Touch the button repeatedly to choose the number of hours you want the dehumidifier to operate (fig.r). • To deactivate the timer function, touch the button repeatedly until is displayed on the screen.

» The dehumidifier goes to combi

AUTO mode.

Philips DE5205 — Setting the Timer diagram (page 12)
Abb. 14 · Setting the Timer

appliance works, it goes to purification only mode when touching the button. • Humidity setting and laundry drying

Using the swing function

Defrosting the dehumidifier

The louver is able to swing up to 90 degrees. Use the swing function to direct the air flow. 1 Touch the button to activate the swing function (fig.p). 2 Touch the button again to deactivate the swing function.

Philips DE5205 — Using the swing function diagram (page 12)
Abb. 15 · Using the swing function
Philips DE5205 — Using the swing function diagram (page 12)
Abb. 16 · Using the swing function

The dehumidifier is equipped with a defrosting sensor to make sure it is in optimal condition when being used in cold weather. The dehumidifier automatically detects if defrosting is required.

turn the louver upward to increase the dehumidifying efficiency.

When defrosting is required:

» The indicator is on (fig.s).

» Defrosting will begin defrosting

and continue until the dehumidifier is completely defrosted.

Page 13 of the Philips DE5205 user manual — Using the continuous drainage
Seite 13 · Zum Vergrößern klicken
Seite 13

5 Draining the dehumidifier

  • During defrosting, the dehumidifier

operates in clothes dry mode. • The dehumidifier will resume

working and operate the previous settings after defrosting is completed.

Emptying the water tank

When the water tank is full:

Setting the child lock

» The appliance beeps, and the

indicator is on.

1 Touch and hold the child lock button for 3 seconds to activate child lock (fig.t).

» The appliance goes to purification

only mode automatically. 1 Place your fingers in the side recess of the dehumidifier, and gently pull the water tank out. Hold the sides of the water tank, and remove it from the dehumidifier (fig.v). 2 Empty the water into a sink (fig.w). 3 Wipe the outside of the water tank dry with a clean cloth (fig.x). 4 Put the water tank back into the dehumidifier (fig.y).

» "L" displays on the screen for 3 seconds.

» When the child lock is on, all the other buttons are not responsive. 2 Touch and hold the child lock button for 3 seconds again to deactivate child lock (fig.u).

» "UL" displays on the screen for 3 seconds.

Using the light on/off function

  • The dehumidifier will resume

working after the water tank is emptied.

With the light on/off button, you can switch on or off the air quality light, the display screen and the function indicators if desired. 1 Touch the light on/off button once, the air quality light will go off. 2 Touch the light on/of button again, the display screen will dimmed. 3 Touch the light on/off button for the third time, all lights will be on again.

Using the continuous drainage

The dehumidifier can also drain excess water by attaching a hose. This allows you to operate the dehumidifier without emptying the water tank. 1 Turn off the dehumidifier and unplug from the wall outlet. 2 Open protective cover of the drainage hole (fig.z).

Page 14 of the Philips DE5205 user manual — Cleaning the body of the dehumidifier
Seite 14 · Zum Vergrößern klicken
Seite 14

3 Remove the water tank from the dehumidifier (fig.v). 4 Insert the Philips provided hose into the drainage hole (fig.{). 5 Push the protective cover of drainage outlet rightwards to open it (fig.|). 6 Connect the hose to the drainage outlet (fig.}). 7 Put the water tank back into the dehumidifier (fig.y).

6 Cleaning

  • Always turn the appliance off and

unplug the appliance from the electrical outlet before cleaning. • Never immerse the appliance in

water or any other liquid. • Never use abrasive or aggressive

cleaning agents such as bleach or alcohol to clean any part of the appliance. • Only the pre-filter is washable. The

  • Put the water tank back in to

air purification filter is not washable. • Do not attempt to clean the filter or

the dehumidifier even using the continuous drainage, or the dehumidifier can not operate normally. • Make sure the hose fits tightly

air quality sensor with a vacuum.

Cleaning the body of the dehumidifier

so that no water leaks from the dehumidifier. • When using the continuous

drainage, make sure the hose is laid flat and not knotted. • Make sure the hose is not immersed

Regularly clean the inside and outside of the dehumidifier to prevent dust from collecting. 1 Use a soft, dry cloth to clean both the interior and exterior of the appliance. 2 The air outlet can also be cleaned with a dry, soft cloth.

in water, nor raised higher than the continuous drainage hole. • Place the outlet of the hose in

somewhere it can easily drain. • Check the dehumidifier once a week

when draining water continuously or left unattended for an extended period of time.

Page 15 of the Philips DE5205 user manual — Cleaning the pre-filter
Seite 15 · Zum Vergrößern klicken
Seite 15

5 Allow the pre-filter to air dry thoroughly before placing back in the dehumidifier.

Cleaning the water tank

Clean the water tank every day to keep it clean. 1 Switch off the dehumidifier and unplug from the electrical outlet. 2 Remove the water tank from the dehumidifier (fig.v). 3 Fill the water tank for 1/3 with water (fig.~). 4 Add some mild washing-up liquid to the water in the water tank. 5 Wash the water tank under a running tap water, and clean the insides of it with a soft clean cloth (fig.5). 6 Wipe the outside of the water tank dry with a clean cloth (fig.x). 7 Put the water tank back into the dehumidifier (fig.y).

  • To optimize the lifetime of the

pre-filter, make sure it dries completely after cleaning. • Wash your hands after handling the

filter.

6 Put the pre-filter back into the appliance (fig.‚). 7 Reattach the rear panel by pressing the bottom part of the rear panel onto the appliance first (1). Then, gently push the panel against the body of the appliance (2) (fig.g). 8 Put the plug of the dehumidifier in the wall outlet. 9 Touch and hold the timer button for 3 seconds to reset the pre-filter. 10 Wash your hands thoroughly after cleaning the filter.

Cleaning the pre-filter

Clean the pre-filter when F0 and are displayed on the screen.

  • The pre-filter is washable and

vacuum cleanable.

1 Switch off the dehumidifier and unplug from the electrical outlet. 2 Hold the dehumidifier and pull the top part of the rear cover towards you (fig.c). 3 Detach the pre-filter from the appliance (fig.€). 4 If the pre-filter is very dirty, use a soft brush to brush away the dust. Wash the pre-filter under a running tap water (fig.;).

Page 16 of the Philips DE5205 user manual — Replacing the filter
Seite 16 · Zum Vergrößern klicken
Seite 16

7 Replacing the filter

Cleaning the air quality sensor

Clean the air quality sensor every 2 months for optimal functioning of the dehumidifier.

Filter replacement indicator

  • If the humidity level in the room

This dehumidifier is equipped with a filter replacement indicator to make sure that the air filter is in optimal condition when the dehumidifier is operating. When the filter needs to be replaced, the filter replacement alert displays on the screen.

is very high, condensation may develop on the air quality sensor and the air quality light may indicate a more poor air quality even though the air quality is actually good. If this occurs, clean the air quality sensor or use the dehumidifier on a manual speed setting. • If the dehumidifier is used in a dusty

If the filter is not replaced in 14 days, the dehumidifier will stop operating and automatically lock. You need to replace the filter immediately.

environment, it may need to be cleaned more often.

1 Switch off the dehumidifier and unplug from the wall outlet. 2 Clean the air quality sensor inlet and outlet with a soft brush (fig.ƒ). 3 Remove the air quality sensor cover (fig.„). 4 Clean the air quality sensor, the dust inlet and the dust outlet with a damp cotton swab (fig.…). 5 Dry all parts thoroughly with a dry cotton swab. 6 Reattach the air quality sensor cover (fig.†).

Replacing the filter

  • The filter is not washable nor

reusable. • Always turn off the dehumidifier and

unplug from the electrical outlet before replacing the filter. • Do not clean the filter with a

vacuum.

Replace the filter when A5 and display on the screen. 1 Switch off the dehumidifier and unplug from the wall outlet. 2 Take out the used filter according to the filter alert light status displayed on the screen. Discard used filters (fig.‡).

Page 17 of the Philips DE5205 user manual — 8 Storage
Seite 17 · Zum Vergrößern klicken
Seite 17

8 Storage

  • Do not touch the pleated filter

surface, or smell the filters as they have collected pollutants from the air.

1 Turn off the dehumidifier and unplug from the wall outlet. 2 Clean the dehumidifier, air quality sensor, empty the water tank and wash the pre-filter (see chapter ‘Cleaning’). 3 Let all parts dry thoroughly before storing. 4 Wrap the filter and pre-filter separately in air tight plastic bags. 5 Store the dehumidifier, filters and pre-filter in a cool, dry location. 6 Always thoroughly wash hands after handling filters.

3 Remove all packaging material from the new filter (fig.e). 4 Place the new filter into the appliance (fig.ˆ). 5 Put the plug of the dehumidifier in to wall outlet. 6 Touch and hold the timer button for 3 seconds to reset the filter lifetime counter. 7 Wash your hands thoroughly after changing the filter.

Page 18 of the Philips DE5205 user manual — 9 Troubleshooting
Seite 18 · Zum Vergrößern klicken
Seite 18

9 Troubleshooting

This chapter summarizes the most common problems you could encounter with the dehumidifier. If you are unable to solve the problem with the information below, visit www.philips.com/support or contact the Consumer Care Center in your country for assistance.

  • The timer is set to a specific time interval. Reset or turn off the timer.
  • Try a different electrical outlet or check the wall switch.
  • Make sure that the water tank is empty and placed in the dehumidifier properly.
  • The filter alert status is displaying the filter code. Replace the corresponding filter and reset the filter lifetime counter (see chapter "Replacing the filter").

The appliance does not work even though it is plugged in to the wall outlet and switched on.

The dehumidifier does not work even though it is switched on.

  • The filter replacement indicator has been on continuously but you have not replaced the corresponding filter, and the appliance is now locked. In this case, replace the filter and reset the filter lifetime counter.

The water tank is empty but the indictor is still on.

  • Remove the water tank from the dehumidifier and place it back to the dehumidifier again.

There is no air dehumidification in the room or the dehumidifying effectiveness is low.

  • Make sure that the filters are clean and in good condition.
  • Make sure the air inlet and outlet are not blocked.
  • The room humidity is below what the dehumidifier is set to. Select a lower humidity level.
  • Make sure that no exterior doors or windows are open.
  • The current temperature is low in the room. Try again until the temperature rises up.

Water leaks from the dehumidifier.

  • Make sure that the dehumidifier is in good condition and the water tank is not cracked.

The dehumidifier does not collect water.

  • The humidity is low. The dehumidifier automatically resumes working when the humidity level is increased.
  • The temperature is low. Wait until the temperature rises up.

Problem Possible solution

Page 19 of the Philips DE5205 user manual — 9 Troubleshooting
Seite 19 · Zum Vergrößern klicken
Seite 19

The airflow that comes out of the air outlet is significantly weaker than before.

  • The pre-filter is dirty. Clean the pre-filter (see chapter "Cleaning").

The air quality does not improve, even though the appliance has been operating for a long time.

  • One of the filters has not been placed in the appliance. Make sure that all filters are properly installed in the following order, starting with the innermost filter: 1) NanoProtect filter Series 1 ( FY1119 ); 2) pre-filter.
  • The air quality sensor is wet. Make sure that the air quality sensor is clean and dry (see chapter "Cleaning").

The color of the air quality light always stays the same.

  • The air quality sensor is dirty. Clean the air quality sensor (see chapter "Cleaning").
  • The first few times you use the dehumidifier, it may produce a plastic smell. This is normal. The dehumidifier may also produce an unpleasant smell when the filter is dirty. In this case, clean or replace the appropriate filter.
  • If the dehumidifier produces a burnt odor, switch OFF and unplug from the electrical outlet. Contact the Consumer Care Center in your country for assistance.

The dehumidifier produces a unpleasant smell.

  • If the dehumidifier is too loud, change the fan speed to a lower fan speed level. When using the product in a bedroom at night, choose a lower fan speed.
  • Make sure that the dehumidifier is placed on a flat and stable surface.

The dehumidifier is loud.

The dehumidifier still indicates that I need to replace a filter, but I already did.

  • Perhaps you did not reset the filter lifetime counter. Plug in the dehumidifier, touch to switch on the dehumidifier, and touch and hold the timer button for 3 seconds.

Error codes "E1", "E2", "E3" “E4” or "E5" displays on the screen.

  • The dehumidifier has malfunctions. Contact the Consumer Care Center in your country.

Problem Possible solution

Page 20 of the Philips DE5205 user manual — 11 Notices
Seite 20 · Zum Vergrößern klicken
Seite 20

10 Guarantee and service

Compliance with EMF Koninklijke Philips N.V. manufactures and sells many products targeted at consumers, which, like any electronic apparatus, in general have the ability to emit and receive electromagnetic signals. One of Philips’ leading Business Principles is to take all necessary health and safety measures for our products, to comply with all applicable legal requirements and to stay well within the EMF standards applicable at the time of producing the products. Philips is committed to develop, produce and market products that cause no adverse health effects. Philips confirms that if its products are handled properly for their intended use, they are safe to use according to scientific evidence available today. Philips plays an active role in the development of international EMF and safety standards, enabling Philips to anticipate further developments in standardization for early integration in its products.

If you need information or if you have a problem, please visit the Philips website at www.philips.com or contact the Philips Consumer Care Center in your country (you can find its phone number in the worldwide guarantee leaflet). If there is no Consumer Care Center in your country, go to your local Philips dealer.

Order parts or accessories

If you have to replace a part or want to purchase an additional part, go to your Philips dealer or visit www.philips.com/ support.

If you have problems obtaining the parts, please contact the Philips Consumer Care Center in your country (you can find its phone number in the worldwide guarantee leaflet).

HFC Information

R134a is hermetically sealed within the product. Refrigerant: R134a Weight: 0.155Kg GWP: 1430 CO2 equivalent: 0.22165 tons

11 Notices

Electromagnetic fields (EMF)

Recycling

This Philips appliance complies with all applicable standards and regulations regarding exposure to electromagnetic fields.

This symbol means that this product shall not be disposed of with normal household waste (2012/19/EU).

Follow your country’s rules for the separate collection of electrical and electronic products. Correct disposal helps prevent negative consequences for the environment and human health.

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Frage zu Philips DE5205 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Philips DE5205

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Philips DE5205 PDF-Anleitung

214 Seiten·3 MB·Luftbefeuchter & -entfeuchter·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…