GWP3 – AUTOMATIC SUBMERSIBLE WATER PUMP FOR DIRTY WATER Introduction To all residents of the European Union Important environmental information about this product

  • This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules. If in doubt, contact your local waste disposal authorities. Thank you for choosing Perel! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, don't install or use it and contact your dealer. Safety Instructions
  • Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems.
  • This device falls under protection class I. It is therefore essential that the device be earthed. Have a qualified person carry out the electric connection.
  • Make sure that the available voltage does not exceed the voltage stated in the specifications of this manual.
  • Do not crimp the power cord and protect it against damage. Have an authorised dealer replace it if necessary.
  • Disconnect the device from the mains to clean it or when it is not in use. Handle the power cord by the plug only.
  • Not covered by warranty: damage caused by user modifications to the device, destruction of rotating mechanical seal by dry-running or addition of foreign bodies in water, blockage of running wheel through foreign bodies, transport damage, damage caused by unauthorized persons.
  • This device should not be used by children and persons with diminished physical, sensory or mental capacities, or by persons lacking knowledge or experience, except if those persons have received, through a person responsible for their safety, of supervision or prior instructions as regards the use of this device. Before Start-Up, Note the Following
  • The pump can be connected to any shock-proof plug which has been installed according to regulations. The plug must have a supply voltage of 230VAC~50Hz. Fuse min. 6 amp.

When used near swimming pools or garden ponds and in their area of protection, the pump must be equipped with a ground-fault circuit interrupter with a nominal trip current of max. 30mA (according to VDE 0100, parts 702 and 738). Do not operate the pump when people are in the garden or pool! Please contact your electrician!

  • Before starting to run your new submersible pump, please have the ground connection and the zero conductor checked by an expert.
  • Fault current breaker switch must comply with the safety regulations of the power plants and they must work faultlessly.
  • The electrical connections must be protected from moisture.
  • If there is danger of flooding, the electrical connections must be taken to higher ground.
  • Circulation of aggressive fluids as well as the circulation of abrasive materials must be avoided at all costs.
  • The submersible motor-driven pump must be protected from frost.
  • The pump must be protected from running dry.
  • Access on the part of children should also be prevented with appropriate measures.

GWP3 PEREL 2

Page 2 of the Perel GWP3 user manual — GWP3 PEREL 3
Seite 2 · Zum Vergrößern klicken
Seite 2
  • Consistency Your submersible pump is designated for the circulation of water with a maximum temperature of 35°C. This pump may not be used for any other fluids and other chemical product. Installation The submersible motor pump can be installed as follows:
  • in a stationary position with fixed pipeline;
  • in a stationary position with a flexible hose pipe. NOTE: Never install the pump by suspending it unsupported from its delivery pipe or power cable. The submersible

motor pump must be suspended from the specially provided handle or be placed on the bottom of the shaft. To guarantee that the pump works properly, the bottom of the shaft must be kept free of sludge and dirt. If the water level sinks too far, any sludge in the shaft will dry out quickly and stop the pump from starting up. It is therefore necessary to check the submersible motor pump regularly (by carrying out start-up tests). The floater is adjusted in a way that the pump can immediately be started. The pump shaft should have minimum dimensions of 40 x 40 x 50cm so that the floating switch can move freely. Mains Supply Your new submersible pump is equipped with a shock-proof plug according to regulations. The pump is designed to be connected to a 230VAC~50Hz safety socket. Make sure that the socket is sufficiently secured (min. 6A) and is in excellent condition. Insert the plug into the socket to operate the pump. NOTE: If the mains cable or plug suffers any damage from external action, repairs to the cable are prohibited. This

  • work may only be performed by a qualified electrician. Areas of Use This pump is used primarily as cellar pump. When installed in a shaft, this pump provides protection from flooding. The pump can also be used wherever water has to be moved from one place to another, e.g. in the home, agriculture, horticulture, plumbing and many other applications. Setting to Work After having read these instructions carefully, you can set your pump to work, reconsidering the following items:
  • check if the pump rests on the ground of the shaft;
  • check if the pressure cord has been attached properly;
  • check the electrical connection (230VAC~50 Hz);
  • check if the socket is in good condition;
  • make sure that water and humidity can never come to the mains supply;
  • avoid dry-running. Setting the ON/OFF Operating Point The ON and OFF operating point of the float switch can be set by adjusting the float switch in its latching holder. Before putting the pump into operation, please check the following:
  • The float switch must be installed so that the level of the ON operating point and the level of the OFF operating point can be reached easily and with little force. To check this, place the pump in a vessel filled with water, raise the float switch carefully by hand and then lower it again. As you do so, note whether the pump switches on and off.
  • Make sure that the distance between the float switch head and the latching holder is not too small. Proper

GWP3 PEREL 3

Page 3 of the Perel GWP3 user manual — GWP3 PEREL 4
Seite 3 · Zum Vergrößern klicken
Seite 3
ProblemPossible CauseSuggested Solution Pump does not start- No mains supply - Floater does not switch- Check mains supply - Bring floater in a higher position No flow- Inlet sieve is clogged - Pressure hose is bent- Clean inlet sieve water jet - Reset hose Pump does not switch off- Floater cannot sink down- Place pump properly on shaft ground Insufficient flow- Inlet sieve is clogged - Reduced pumping capacity by dirty and abrasive water- Clean inlet sieve - Clean pump and replace worn out parts Pump switches off after short operating period- Thermal cut-out stops pump due to dirty water - Water is too hot; thermal cut-out stops pump- Remove mains plug, clean pump and shaft - Make sure the water temperature of 35°C is not exceeded

GWP3 PEREL 4

Reparatur

Fehlerbehebung

Häufige Probleme, wahrscheinliche Ursachen und Lösungen.

ProblemMögliche UrsacheAbhilfe
Pump does not start- No mains supply - Floater does not switch- Check mains supply - Bring floater in a higher position p.3
No flow- Inlet sieve is clogged - Pressure hose is bent- Clean inlet sieve water jet - Reset hose p.3
Pump does not switch off- Floater cannot sink down- Place pump properly on shaft ground p.3
Insufficient flow- Inlet sieve is clogged - Reduced pumping capacity by dirty and abrasive water- Clean inlet sieve - Clean pump and replace worn out parts p.3
Pump switches off after short operating period- Thermal cut-out stops pump due to dirty water - Water is too hot; thermal cut-out stops pump- Remove mains plug, clean pump and shaft - Make sure the water temperature of 35°C is not exceeded p.3

Frage zu Perel GWP3 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Perel GWP3

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Perel GWP3 PDF-Anleitung

19 Seiten·307 KB·Gartenpumpe·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…