GWP3 – AUTOMATIC SUBMERSIBLE WATER PUMP FOR DIRTY WATER Introduction To all residents of the European Union Important environmental information about this product
When used near swimming pools or garden ponds and in their area of protection, the pump must be equipped with a ground-fault circuit interrupter with a nominal trip current of max. 30mA (according to VDE 0100, parts 702 and 738). Do not operate the pump when people are in the garden or pool! Please contact your electrician!

motor pump must be suspended from the specially provided handle or be placed on the bottom of the shaft. To guarantee that the pump works properly, the bottom of the shaft must be kept free of sludge and dirt. If the water level sinks too far, any sludge in the shaft will dry out quickly and stop the pump from starting up. It is therefore necessary to check the submersible motor pump regularly (by carrying out start-up tests). The floater is adjusted in a way that the pump can immediately be started. The pump shaft should have minimum dimensions of 40 x 40 x 50cm so that the floating switch can move freely. Mains Supply Your new submersible pump is equipped with a shock-proof plug according to regulations. The pump is designed to be connected to a 230VAC~50Hz safety socket. Make sure that the socket is sufficiently secured (min. 6A) and is in excellent condition. Insert the plug into the socket to operate the pump. NOTE: If the mains cable or plug suffers any damage from external action, repairs to the cable are prohibited. This

Häufige Probleme, wahrscheinliche Ursachen und Lösungen.
| Problem | Mögliche Ursache | Abhilfe | |
|---|---|---|---|
| Pump does not start | - No mains supply - Floater does not switch | - Check mains supply - Bring floater in a higher position | p.3 |
| No flow | - Inlet sieve is clogged - Pressure hose is bent | - Clean inlet sieve water jet - Reset hose | p.3 |
| Pump does not switch off | - Floater cannot sink down | - Place pump properly on shaft ground | p.3 |
| Insufficient flow | - Inlet sieve is clogged - Reduced pumping capacity by dirty and abrasive water | - Clean inlet sieve - Clean pump and replace worn out parts | p.3 |
| Pump switches off after short operating period | - Thermal cut-out stops pump due to dirty water - Water is too hot; thermal cut-out stops pump | - Remove mains plug, clean pump and shaft - Make sure the water temperature of 35°C is not exceeded | p.3 |
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.