DE
Perel logo
Offizielle Bedienungsanleitung

Perel EVM440

27 Seiten·510 KB·Thermometer·PDF·ENITJA
Perel EVM440
Inhaltsverzeichnis 1 Abschnitte USER MANUAL AnzeigenAusblenden
Page 1 of the Perel EVM440 user manual
Seite 1 · Zum Vergrößern klicken
Seite 1
Perel EVM440 diagram (page 1)
Abb. 1

NON-CONTACT INFRARED THERMOMETER WITH LASER CONTACTVRIJE IR-THERMOMETER MET LASERPOINTER THERMOMÈTRE IR SANS CONTACT AVEC POINTEUR LASER TERMÓMETRO IR DE BOLSILLO CON PUNTERO LÁSER INFRAROT-THERMOMETER MIT LASERPOINTER TERMÓMETRO COM INFRAVERMELHOS E LASER

Perel EVM440 diagram (page 1)
Abb. 2

USER MANUAL 2 GEBRUIKERSHANDLEIDING 6 MODE D'EMPLOI 10 MANUAL DEL USUARIO 14 BEDIENUNGSANLEITUNG 18 MANUAL DO UTILIZADOR 22

Page 2 of the Perel EVM440 user manual — 3. General Guidelines
Seite 2 · Zum Vergrößern klicken
Seite 2

USER MANUAL

1. Introduction

To all residents of the European Union

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules.

If in doubt, contact your local waste disposal authorities. Thank you for choosing Perel! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, don't install or use it and contact your dealer.

First use: laser warning sticker

The device is labelled with a laser warning sticker in English. The package contains stickers in other languages. If the user does not understand English, put the sticker with the language on the device.

1. Refer to the safety instructions before using the device.
2. Make sure the device does not contain batteries.
3. Put the sticker in your language on the device.
4. When done, insert batteries (see section Battery below).

2. Safety Instructions

Keep out of reach of children. When device is in use, NEVER look directly or indirectly (reflectance) into the laser beam. Never point the beam toward people's or animals' eyes or allow the beam to strike the eye from a reflective surface. Use extreme caution when the laser pointer beam is on. Do not use the laser near explosive gases or in other potentially explosive areas. Keep this device away from rain, moisture, splashing and dripping liquids. DO NOT disassemble or open the cover. No user-serviceable parts inside. Refer to an authorized dealer for service and/or spare parts. Warning! Visible laser radiation. Do not stare into the beam as eye damage will occur. This device contains a class 2 laser. Output power does not exceed 1 mW, wavelength 650 nm.
  • Replace the battery as soon as the battery indicator appears on the display.
  • Do not use the thermometer if it operates abnormally.
  • Do not operate the thermometer around explosive gas, vapour, or dust.
  • To avoid burn hazard, remember that highly reflective objects will often result in lower than actual temperature measurements.
  • Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems.
  • Note that damage caused by user modifications to the device is not covered by the warranty.

3. General Guidelines

Refer to the Velleman® Service and Quality Warranty on the last pages of this manual.

  • Only use the device with appropriate batteries (see Technical Specifications below).
  • Protect this device from shocks and abuse. Avoid brute force when operating the device.
  • Protected the device against extreme heat (see Technical Specifications below), dust and moisture.
Page 3 of the Perel EVM440 user manual — 6. Operation
Seite 3 · Zum Vergrößern klicken
Seite 3
  • Familiarise yourself with the functions of the device before actually using it.
  • All modifications of the device are forbidden for safety reasons.
  • Only use the device for its intended purpose. Using the device in an unauthorised way will void the warranty.
  • Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of about 3 volts per meter, but the performance of the instrument will not be permanently affected.
  • Operating temperature: see technical specifications.

4. Features

  • laser sight technology
  • temperature readout in °C or °F
  • large LCD display with blue backlight
  • real-time maximum temperature reading
  • auto power-off function

5. Overview

Perel EVM440 — 5. Overview diagram (page 3)
Abb. 3 · 5. Overview

5 laser pointer beam

8 data hold icon

Perel EVM440 — 5. Overview diagram (page 3)
Abb. 4 · 5. Overview

10 laser on icon

11 backlight on icon

12 battery power icon

15 laser on/off button

Perel EVM440 — 5. Overview diagram (page 3)
Abb. 5 · 5. Overview

17 back light switch

6. Operation

1. Hold the meter by its grip and point it toward the surface to be measured. Read the section Distance-tospot ratio below for distance to target ratio information.
2. Pull and hold the trigger to turn the meter on and begin testing. The display will light if the battery is good.
3. While measuring temperature, you can:
Show 13 more labels / short text on this page
Device · 1 LCD display · 2 function buttons · 3 handle grip · 4 IR sensor · 6 measurement trigger · 7 battery compartment · Display · 9 scanning icon · 13 temperature unit · 14 temperature reading · Display buttons · 16 Celsius/Fahrenheit switch
Page 4 of the Perel EVM440 user manual — 9. Technical Specifications
Seite 4 · Zum Vergrößern klicken
Seite 4

o Push the Laser button to switch the laser pointer ON. The laser pointer is only used for aiming. When the laser is on, the laser icon appears appear on the LCD. Aim the red beam approximately 1 cm below the point of test. Pressing the Laser button again turns the laser off.

o Select the temperature units using the °C/°F button. 4. Release the trigger. The reading will hold for approximately 7 seconds. The devices shuts off automatically after 20 seconds.

When backlight is on, any operation activates the backlight for about 7 seconds.

Perel EVM440 — USER MANUAL diagram (page 4)
Abb. 6

Distance-to-spot ratio (D:S)

  • The device's distance-to-spot ratio is 12:1.
  • The distance-to-spot ratio (D:S) is the ratio of the distance to the object and the diameter of the temperature measurement area.
  • For instance if the D:S ratio is 12:1, measurement of an object 120 cm away will average the temperature over a 10 cm area.

7. Battery

Replace the battery when the battery low icon appears on the display or if the device does not light when you pull the trigger.

The battery is located in the hand grip.

1. Pull open the hand grip. 2. Insert a battery. Only use appropriate batteries (see Technical Specifications below). Respect the polarity.
3. Close the battery cover.
  • Keep batteries away from children.
  • Do not puncture batteries or throw them in fire as they may explode.
  • Do not attempt to recharge non-rechargeable batteries (alkaline).
  • Dispose of batteries in accordance with local regulations.

8. Cleaning and Maintenance

  • The sensor lens is the most delicate part of the thermometer and should be kept clean at all times.
  • To do this, only use a soft cloth or cotton bud with a little water or medical alcohol.
  • Allow the lens to fully dry before using the thermometer.
  • Wipe the other parts of the thermometer regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
  • Do not submerge the thermometer in water or any other liquid.
  • There are no user-serviceable parts.
  • Contact your dealer for spare parts if necessary.
  • Storage temperature: see technical specifications.

9. Technical Specifications

measurement range-32 °C to 350°C (-26 °F to 662 °F) operating temperature0-50 °C (32-122 °F) storage temperature-20 °C to 65 °C (-4 °F to 149 °F) accuracy± 1.5 % or 1.5 °C (2.7 °F) resolution0.1 °C / 0.2 °F response time (90 %)0.5 second emissivity range0.95 fixed

Backlight

Page 5 of the Perel EVM440 user manual — USER MANUAL
Seite 5 · Zum Vergrößern klicken
Seite 5
auto switching-off and data hold7 seconds distance-to-spot ratio D:S12:1 power supply1 x 9 V (not incl.) dimensions48.8 x 133 x 146 mm weight130 g without battery

The information in this manual is subject to change without prior notice.

© COPYRIGHT NOTICE The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the prior written consent of the copyright holder.

Frage zu Perel EVM440 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Perel EVM440

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Perel EVM440 PDF-Anleitung

27 Seiten·510 KB·Thermometer·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…