CHARGER FOR 12 V LEAD-ACID BATTERIES - 6 A LADER VOOR 12 V LOODZUURACCU'S - 6 A CHARGEUR POUR BATTERIE À ACIDE DE PLOMB - 12 V - 6 A CARGADOR PARA BATERÍAS DE PLOMO-ÁCIDO 12 V - 6 A LADEGERÄT FÜR 12 V BLEI-SÄURE-AKKUS - 6 A CARREGADOR PARA BATERIAS DE CHUMBO-ÁCIDO 12 V - 6 A

USER MANUAL 3 GEBRUIKERSHANDLEIDING 6 MODE D’EMPLOI 9 MANUAL DEL USUARIO 12 BEDIENUNGSANLEITUNG 15 MANUAL DO UTILIZADOR 18



To all residents of the European Union Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules. If in doubt, contact your local waste disposal authorities. Thank you for choosing Perel! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, do not install or use it and contact your dealer.
Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems. Make sure that the available voltage does not exceed the voltage stated in the specifications of this manual. Do not crimp the power cord or leads and protect them against damage. Have an authorised dealer replace it if necessary. Do not use the device when damage to housing or cables is noticed. Do not attempt to service the device yourself but contact an authorised dealer. Note that damage caused by user modifications to the device is not covered by the warranty. Do not try to open the housing of the battery or battery charger. Do not expose the battery and charger to full sunlight or high temperatures. Acid may start to boil. This is not unusual, but in order to prevent accidents switch off the charger and let the battery cool down. Charging has to take place in a well ventilated area. Always handle batteries with care. When smoke or stench from scorched insulation is noticed, immediately unplug the charger from the mains. There are no user-serviceable parts in the charger. Contact your dealer for spare parts if necessary.

Refer to the Velleman® Service and Quality Warranty on the last pages of this manual.
Protect this device from shocks and abuse. Avoid brute force when operating the device. Protect the device against extreme heat, dust and moisture. Familiarise yourself with the functions of the device before actually using it. All modifications of the device are forbidden for safety reasons. Only use the device for its intended purpose. Using the device in an unauthorised way will void the warranty.
overload protection (for charger) integrated ampere meter for various motor cars, vans and light trucks included accessories:
o charging cable (1.5 m + 1.5 m)
o 2 replaceable spare fuses
Refer to the illustrations on page 2 of this manual.
Always check the condition of the cables and clamps before using the battery charger. Do not use when damage is noticed!
Disconnect the battery from the vehicle before charging. To do this, first remove the negative pole connection, and then proceed with the positive pole connection. When applicable (non-sealed battery), check the level of the battery acid. When necessary, add distilled water. Clean the poles with a steel brush or sandpaper. Make sure the battery charger is not connected to the mains. Connect the positive clamp of the battery charger (red) with the positive pole (+) of the battery. Make sure the clamp is secured tight. Connect the negative clamp of the battery charger (black) with the negative pole (-) of the battery. Make sure the clamp is secured tight.
The status of the charging process is indicated by 3 LEDs on the front of the unit. Refer to the illustration on page 2 of this manual. When the battery charger is correctly connected to the battery, the red LED [A] lights up. Otherwise, check the polarity of the connections and the fuse [D]. When the battery has filler caps, unscrew them before charging. To start charging the battery, connect the battery charger to the mains. Make sure the correct mains voltage is supplied (see technical specifications below). The red LED [A] will remain on during the entire charging procedure. The yellow LED [B] indicates that the battery charger is connected to the mains and the charging procedure is ongoing. If the yellow LED [B] does not light up, check the condition of the mains socket and the mains. When the yellow LED [B] turns off during charging, the circuit was interrupted by the internal transformer overload protection system. Disconnect the charger from the mains and allow it to cool
o two clamps

down/stabilize for about 10 minutes before re-connecting to the mains. If after several hours the charger still doesn’t indicate that the battery is being charged, a short-circuited element might be present inside the battery. The battery must be replaced. The charging procedure is finished when the green LED [C] lights up. Note that the intensity of the green LED [C] gradually builds up. The battery charger doesn’t stop automatically. When the green LED [C] shines bright, disconnect the charger from the mains. Disconnect the battery from the charger, starting with the clamp on the negative pole (black) and than proceed with the clamp on the positive pole (red). When the fuse [D] is blown, the fuse will light. Replace the fuse in the front of the charger by a fuse with the same specifications. Make sure no battery is connected to the charger and the charger is disconnected from the mains when replacing the fuse. Use a small screwdriver as a lever to release the fuse from its socket. Insert the new fuse. Avoid the use of excessive force!
Always remove the plug from the mains socket and disconnect batteries when servicing or cleaning the charger. Never use water or any other liquids to clean the charger. Keep the cables clean, but avoid using cleaners based on benzene, trichloroethylene, chloride, ammonia … as they affect or even dissolve plastic parts. Check liquid level of batteries once per month and fill up when necessary. Dispose of batteries in accordance with local regulations.
rated input voltage 230 V~, 50 Hz rated output current 4.5 A effective charging current 6 A exchangeable fuse 20 A reference battery capacity 20-90 Ah IP-code IP20 weight 3 kg dimensions 230 x 175 x 115 mm Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulting from (incorrect) use of this device. For more info concerning this product and the latest version of this manual, please visit our website www.perel.eu The information in this manual is subject to change without prior notice.