DE
Panasonic logo
Offizielle Bedienungsanleitung

Panasonic U-10EA1E8

112 Seiten·8 MB·Klimaanlage·PDF·ENJA
Panasonic U-10EA1E8
Inhaltsverzeichnis 67 Abschnitte Operating Instructions FS Multi Air Conditioner · F567780 · SAFETY PRECAUTIONS SAFETY PRECAUTIONS · TABLE OF CONTENTS TABLE OF CONTENTS · … AnzeigenAusblenden
Operating Instructions FS Multi Air Conditionerp.1F567780p.1SAFETY PRECAUTIONS SAFETY PRECAUTIONSp.2TABLE OF CONTENTS TABLE OF CONTENTSp.2SAFETY PRECAUTIONSp.2CAUTION CAUTIONp.2INFORMATIONp.2MULTI AIR CONDITIONER FUNCTIONp.2PRODUCT OVERVIEW & OPERATIONS (WIRELESS REMOTE CONTROL)p.2WARNING WARNINGp.2INDOOR UNIT AND OUTDOOR UNITp.2PRODUCT OVERVIEW & OPERATIONS (WIRED REMOTE CONTROL)p.2CARE & CLEANINGp.2TROUBLESHOOTINGp.2QUICK GUIDEp.2REMOTE CONTROLp.2BACK COVERp.2NOTE NOTEp.2POWER SUPPLYp.3INFORMATION INFORMATIONp.4OPERATION CONDITION OPERATION CONDITIONp.4TO SET DAILY TIMER TO SET DAILY TIMERp.7OFF/ON TO TURN ON OR OFF THE UNITp.7POWERp.7TO SET TEMPERATUREp.7MODE TO SELECT OPERATION MODEp.7OPTIONAL SETTINGS OPTIONAL SETTINGS FAN SPEED TO SELECT FAN SPEED (3 OPTIONS)p.7LOW MEDIUM AUTO HIGHp.7ADDRESSp.7MANUAL AUTO TO ADJUST AIRFLOW DIRECTIONp.7AUTO 1 AUTO 2 AUTO 3p.7HINT HINTp.7UPp.9MODE SELECTp.9DOWN TO SET TEMPERATUREp.9DOWNp.9FAN SPEED TO SELECT FAN SPEED (3 OPTIONS)p.9LO MED AUTO HIp.9AUTO MANUAL TO ADJUST AIRFLOW DIRECTIONp.9TO SET WEEKLY TIMER TO SET WEEKLY TIMERp.10OPERATION DETAILS OPERATION DETAILSp.10MODEp.10AUTO AUTOp.10MON TUE WED THU FRI SAT SUN ONp.10OFF / Op.10CZ-RT1p.10OFF / ONp.10TIMER/CLOCKp.10AIR SWING ECONOMYp.10CHECK ODOUR WASH VENTILATION TEST RUN FILTER RESETp.10ECONOMYp.10CHECK ODOURWASH VEp.10MON TUE WED THU FRI SAT SUNp.10ON OFFp.10CARE & CLEANING CARE & CLEANINGp.11CAUTIONp.11CLEANING INSTRUCTIONS CLEANING INSTRUCTIONSp.11HINTS HINTSp.11Remove Air Filter Air Filter Installationp.11CLOSE OPEN OPEN CLOSEp.11INDOOR UNIT INDOOR UNITp.11OPEN CLOSE CLOSE OPENp.11AIR FILTER AIR FILTERp.11AUTO FAN COOL DRYp.11FILTER RESET AUTOp.11FILTERp.11TROUBLESHOOTING TROUBLESHOOTINGp.12
Page 1 of the Panasonic U-10EA1E8 user manual — F567780
Seite 1 · Zum Vergrößern klicken
Seite 1
Panasonic U-10EA1E8 — Operating Instructions FS Multi Air Conditioner diagram (page 1)
Abb. 1 · Operating Instructions FS Multi Air Conditioner

Operating Instructions FS Multi Air Conditioner

Model No. Indoor Unit Outdoor Unit S-22YA1E5 U-4LA1E5 S-28YA1E5 U-5LA1E5 S-36YA1E5 U-6LA1E5 S-45YA1E5 U-4LA1E5-1 S-56YA1E5 U-5LA1E5-1 U-6LA1E5-1 * U-8EA1E8 * U-10EA1E U-10EA1E8

ENGLISH ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference. * Available to selected country

2 ~ 13 2 ~ 13

FRANÇAIS Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure. * Achetez pour un pays spécial

14 ~ 25 14 ~ 25

ESPAÑOL Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta. * Comprar para país especial

DEUTSCH Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf. * Für ein spezielles Land kaufen

38 ~ 49 38 ~ 49

ITALIANO Prima di utilizzare l’unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento in futuro. * Acquisto per un paese speciale

NEDERLANDS Lees voor u het apparaat gebruikt deze gebruiksinstructies grondig en bewaar ze voor toekomstig gebruik. * Kopen voor uitzonderlijk staten

62 ~ 73 62 ~ 73

PORTUGUÊS Antes de ligar a unidade, leia cuidadosamente este manual de utilização e guarde-o para futura referência. * Compra para país especial

EΛΛΗΝΙΚΆ Προτού θέσετε τη μονάδα σε λειτουργία, διαβάστε προσεκτικά αυτές τις οδηγίες χρήσης και φυλάξτε τις για μελλοντική αναφορά. * Αγορά για συγκεκριμένη χώρα

БЪЛГАРСКИ БЪЛГАРСКИ Преди да задействате климатика, прочетете внимателно инструкциите за употреба и ги запазете за бъдещи справки. * Покупка за специална страна

98 ~109 98 ~109

Panasonic U-10EA1E8 — Operating Instructions FS Multi Air Conditioner diagram (page 1)
Abb. 2 · Operating Instructions FS Multi Air Conditioner

QUICK GUIDE / GUIDE RAPIDE QUICK GUIDE / GUIDE RAPIDE GUÍA RÁPIDA / KURZANLEITUNG GUÍA RÁPIDA / KURZANLEITUNG GUIDA RAPIDA / SNELLE GIDS GUIDA RAPIDA / SNELLE GIDS GUΙA RÁPIDO / ΣYNTOMOΣ O∆HГOΣ GUΙA RÁPIDO / ΣYNTOMOΣ O∆HГOΣ БЪРЗ СПРАВОЧНИК БЪРЗ СПРАВОЧНИК

© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2010. Unauthorized copying and distribution is a violation of law.

F567780

Show 4 more labels / short text on this page
26 ~ 37 · 50 ~ 61 · 74 ~ 85 · 86 ~ 97
Page 2 of the Panasonic U-10EA1E8 user manual — Inhaltsverzeichnis
Seite 2 · Inhalt
Inhalt

Inhalt

Operating Instructions FS Multi Air Conditionerp.1F567780p.1SAFETY PRECAUTIONS SAFETY PRECAUTIONSp.2TABLE OF CONTENTS TABLE OF CONTENTSp.2SAFETY PRECAUTIONSp.2CAUTION CAUTIONp.2INFORMATIONp.2MULTI AIR CONDITIONER FUNCTIONp.2PRODUCT OVERVIEW & OPERATIONS (WIRELESS REMOTE CONTROL)p.2WARNING WARNINGp.2INDOOR UNIT AND OUTDOOR UNITp.2PRODUCT OVERVIEW & OPERATIONS (WIRED REMOTE CONTROL)p.2CARE & CLEANINGp.2TROUBLESHOOTINGp.2QUICK GUIDEp.2REMOTE CONTROLp.2BACK COVERp.2NOTE NOTEp.2POWER SUPPLYp.3INFORMATION INFORMATIONp.4OPERATION CONDITION OPERATION CONDITIONp.4TO SET DAILY TIMER TO SET DAILY TIMERp.7OFF/ON TO TURN ON OR OFF THE UNITp.7POWERp.7TO SET TEMPERATUREp.7MODE TO SELECT OPERATION MODEp.7OPTIONAL SETTINGS OPTIONAL SETTINGS FAN SPEED TO SELECT FAN SPEED (3 OPTIONS)p.7LOW MEDIUM AUTO HIGHp.7ADDRESSp.7MANUAL AUTO TO ADJUST AIRFLOW DIRECTIONp.7AUTO 1 AUTO 2 AUTO 3p.7HINT HINTp.7UPp.9MODE SELECTp.9DOWN TO SET TEMPERATUREp.9DOWNp.9FAN SPEED TO SELECT FAN SPEED (3 OPTIONS)p.9LO MED AUTO HIp.9AUTO MANUAL TO ADJUST AIRFLOW DIRECTIONp.9TO SET WEEKLY TIMER TO SET WEEKLY TIMERp.10OPERATION DETAILS OPERATION DETAILSp.10MODEp.10AUTO AUTOp.10MON TUE WED THU FRI SAT SUN ONp.10OFF / Op.10CZ-RT1p.10OFF / ONp.10TIMER/CLOCKp.10AIR SWING ECONOMYp.10CHECK ODOUR WASH VENTILATION TEST RUN FILTER RESETp.10ECONOMYp.10CHECK ODOURWASH VEp.10MON TUE WED THU FRI SAT SUNp.10ON OFFp.10CARE & CLEANING CARE & CLEANINGp.11CAUTIONp.11CLEANING INSTRUCTIONS CLEANING INSTRUCTIONSp.11HINTS HINTSp.11Remove Air Filter Air Filter Installationp.11CLOSE OPEN OPEN CLOSEp.11INDOOR UNIT INDOOR UNITp.11OPEN CLOSE CLOSE OPENp.11AIR FILTER AIR FILTERp.11AUTO FAN COOL DRYp.11FILTER RESET AUTOp.11FILTERp.11TROUBLESHOOTING TROUBLESHOOTINGp.12
Page 3 of the Panasonic U-10EA1E8 user manual — WARNING WARNING
Seite 3 · Zum Vergrößern klicken
Seite 3
CAUTION INDOOR UNIT AND OUTDOOR UNIT Do not wash the indoor unit with water, benzene, thinner or scouring powder. Do not use for other purpose such as preservation of food. Do not use any combustible equipment in front of the airfl ow outlet to avoid fi re propagation. Do not expose yourself directly to cold air for a long period. Do not sit or step on the unit, you may fall down accidentally. Do not touch the sharp aluminium fi n, sharp parts may cause injury. Do not switch ON the indoor unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit. Do not install the unit in oily and smoky areas. Ensure drainage pipe is connected properly. Otherwise, leakage may occur. Aerate the room regularly. After long period of use, make sure the installation rack is not deteriorate to prevent the unit from falling down. REMOTE CONTROL Do not use rechargeable (Ni-Cd) batteries. It may damage the remote control. Remove the batteries if the unit is not going to be used for a long period of time. New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.

WARNING WARNING

POWER SUPPLY

Do not use modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re. Do not share the same power outlet with other equipment to prevent overheating and fi re.

Do not operate with wet hands to prevent electric shock. If the supply cord is damage, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.

It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fi re. This equipment must be earthed to prevent electrical shock or fi re.

Prevent electric shock by switching off the power supply when: - Before cleaning or servicing. - Extended non-use. - Abnormally strong lightning activity.

Stop using the product when any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fi re/electric shock) Examples of abnormality/ failure• The ELCB trips frequently. • Burning smell is observed. • Abnormal noise or vibration of the unit is observed. • Water leaks from the indoor unit. • Power cord or plug becomes abnormally hot. • Fan speed cannot be controlled. • The unit stops running immediately even if it is switched on for operation. • The fan does not stop even if the operation is stopped. Contact immediately your local dealer for maintenance/repair.

Air Outlet Air Outlet

Air Inlet Air Inlet

Air Inlet Air Inlet

Air Inlet Air Inlet

Air Outlet Air Outlet

Show 4 more labels / short text on this page
Indoor Unit · Power Supply · Remote Control · Outdoor Unit
Page 4 of the Panasonic U-10EA1E8 user manual — OPERATION CONDITION OPERATION CONDITION
Seite 4 · Zum Vergrößern klicken
Seite 4

INFORMATION INFORMATION

Panasonic U-10EA1E8 — INFORMATION INFORMATION diagram (page 4)
Abb. 3

OPERATION CONDITION OPERATION CONDITION

Use this air conditioner under the following temperature range

Temperature (°C)IndoorOutdoor COOLINGMaximum3243 Minimum21-5 HEATINGMaximum2724 Minimum16-15

as a computer room, with a room temperature of 21°C or above, and room humidity up to 80%.

Panasonic U-10EA1E8 — OPERATION CONDITION OPERATION CONDITION diagram (page 4)
Abb. 4

Information for Users on Collection and Disposal of Old Equipment and used Batteries

These symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic products and batteries should not be mixed with general household waste. For proper treatment, recovery and recycling of old products and used batteries, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC. By disposing of these products and batteries correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. For more information about collection and recycling of old products and batteries, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items. Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation. For business users in the European Union If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information. [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal. Note for the battery symbol (bottom two symbol examples): This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved. Pb

Page 5 of the Panasonic U-10EA1E8 user manual — INFORMATION INFORMATION
Seite 5 · Zum Vergrößern klicken
Seite 5
Panasonic U-10EA1E8 — INFORMATION INFORMATION diagram (page 5)
Abb. 5

DEFINITION Multi air conditioner system has one outdoor unit connected to multiple indoor units.

  • It is possible to operate the indoor units individually or simultaneously.
  • The operation mode priority is given to the fi rst unit that turned on.
  • During operation, heating and cooling mode could not be activated at the same time for different indoor unit.
  • The power indicator blinks to indicate the indoor unit is standing by for different operation mode.
Page 6 of the Panasonic U-10EA1E8 user manual — INFORMATION INFORMATION
Seite 6 · Zum Vergrößern klicken
Seite 6
Panasonic U-10EA1E8 — INFORMATION INFORMATION diagram (page 6)
Abb. 6

PRODUCT OVERVIEW & OPERATIONS (WIRELESS REMOTE CONTROL) PRODUCT OVERVIEW & OPERATIONS (WIRELESS REMOTE CONTROL)

Auto OFF/ON button • To operate the unit if the wireless remote control is misplaced or malfunctioning.

ActionMode Press once.Auto Press and hold until you hear 1 beep, then release.Cooling 1. Press and hold until you hear 2 beeps then release. 2. Press the button for 5 seconds. SETHeating Press the button to turn off.

2 Insert AAA or R03 batteries (can be used ~ 1 year) 5 Confi rm

Page 7 of the Panasonic U-10EA1E8 user manual — HINT HINT
Seite 7 · Zum Vergrößern klicken
Seite 7
Panasonic U-10EA1E8 — TO SET DAILY TIMER TO SET DAILY TIMER diagram (page 7)
Abb. 7

TO SET DAILY TIMER TO SET DAILY TIMER

OFF/ON TO TURN ON OR OFF THE UNIT

POWER

  • To turn ON or OFF the unit at a preset time.

TO SET TEMPERATURE

Set the time. Confi rm.

  • Selection range: 16°C ~ 31°C.

OFF timer.

  • To cancel ON or OFF timer, press CANCEL .

MODE TO SELECT OPERATION MODE

  • AUTO mode - For your convenience
  • Unit selects operation mode according to temperature setting, outdoor and room temperature. HEAT mode - To enjoy warm air
  • Unit takes a while to warm up. FAN mode - To enables air circulation in the room COOL mode - To enjoy cool air DRY mode - To dehumidify the environment
  • Unit operates at low fan speed to give a gentle cooling operation.
  • During soft dry operation, the indoor fan operates at a low fan speed.
  • The louvers movement might not align with the remote control display.
  • When ON timer is set, the unit may start early before the actual set time in order to achieve the desired temperature on time.
  • Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control preparation.
  • The timer closest to the current time will be activated fi rst.
  • If timer is cancelled manually, you can restore the previous setting by pressing SET .
  • If the main power is switched off for an hour or more, the clock and timer will need to be set again.

OPTIONAL SETTINGS OPTIONAL SETTINGS FAN SPEED TO SELECT FAN SPEED (3 OPTIONS)

  • To avoid unintentional operation, you can assign a different address to each indoor unit.
  • Press repeatedly to select your desired address setting.

LOW MEDIUM AUTO HIGH

  • For AUTO, the indoor fan speed is automatically adjusted according to the operation mode.
  • If the operation mode is set to Fan, the fan speed will be fi xed at MEDIUM regardless of the temperature setting.

Address 1 Address 2 Group Address 3

ADDRESS

  • By default, ADDRESS 1 is selected. You do not need to change this setting for normal operation.
  • If the address is set to GROUP, more than one indoor unit can be operated at the same time.

MANUAL AUTO TO ADJUST AIRFLOW DIRECTION

  • Keeps the room ventilated.
  • The air is discharge evenly through 4 output vents.

RC RESET Press to restore the remote control’s default setting.

AUTO 1 AUTO 2 AUTO 3

SET AC RESET Not used in normal operations.

  • There are 3 options for auto vertical airfl ow direction.
  • The vertical airfl ow louver swings up and down automatically.
  • Do not adjust the vertical airfl ow direction louvers by hand.

HINT HINT

  • Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode.
  • There are 4 options for manual vertical airfl ow direction.
  • The airfl ow direction can be adjusted as desired by using remote control.

Select ON or

Page 8 of the Panasonic U-10EA1E8 user manual — TO SET DAILY TIMER TO SET DAILY TIMER
Seite 8 · Zum Vergrößern klicken
Seite 8
Panasonic U-10EA1E8 — TO SET DAILY TIMER TO SET DAILY TIMER diagram (page 8)
Abb. 8

PRODUCT OVERVIEW & OPERATIONS (WIRED REMOTE CONTROL) PRODUCT OVERVIEW & OPERATIONS (WIRED REMOTE CONTROL)

, VENTILATION and TEST RUN buttons are not in use.

4 Repeat steps 2 and 3 to set the current time.

Page 9 of the Panasonic U-10EA1E8 user manual — AUTO 1 AUTO 2 AUTO 3
Seite 9 · Zum Vergrößern klicken
Seite 9

TO SET DAILY TIMER TO SET DAILY TIMER

OFF / ON TO TURN ON OR OFF THE UNIT

  • To turn ON or OFF the unit at a preset time.

UP

MODE SELECT

DOWN TO SET TEMPERATURE

Enter daily timer mode. Select ON or OFF timer.

  • Selection range: 16°C ~ 31°C.

UP

MODE TO SELECT OPERATION MODE

DOWN

  • AUTO mode - For your convenience
  • Unit selects operation mode according to temperature setting, outdoor and room temperature. HEAT mode - To enjoy warm air
  • Unit takes a while to warm up. FAN mode - To enables air circulation in the room COOL mode - To enjoy cool air DRY mode - To dehumidify the environment
  • Unit operates at low fan speed to give a gentle cooling operation.
  • During soft dry operation, the indoor fan operates at a low fan speed.
  • The louvers movement might not align with the remote control display.

Set the time. Confi rm.

  • To cancel ON or OFF timer, press
  • When ON timer is set, the unit may start early before the actual set time in order to achieve the desired temperature on time.
  • Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control preparation.
  • The timer closest to the current time will be activated fi rst.
  • If timer is cancelled manually, you can restore the previous setting by pressing

SET. • If the main power is switched off for an hour or more, the clock and timer will need to be set again.

FAN SPEED TO SELECT FAN SPEED (3 OPTIONS)

LO MED AUTO HI

  • For AUTO, the indoor fan speed is automatically adjusted according to the operation mode.
  • If the operation mode is set to Fan, the fan speed will be fi xed at MED regardless of the temperature setting.

HINT HINT

  • Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode.

AUTO MANUAL TO ADJUST AIRFLOW DIRECTION

  • Keeps the room ventilated.
  • The air is discharge evenly through 4 output vents.

AUTO 1 AUTO 2 AUTO 3

  • There are 3 options for auto vertical airfl ow direction.
  • The vertical airfl ow louver swings up and down automatically.
  • Do not adjust the vertical airfl ow direction louvers by hand.
  • There are 4 options for manual vertical airfl ow direction.
  • The airfl ow direction can be adjusted as desired by using remote control.
Page 10 of the Panasonic U-10EA1E8 user manual — UP
Seite 10 · Zum Vergrößern klicken
Seite 10
Panasonic U-10EA1E8 — TO SET WEEKLY TIMER TO SET WEEKLY TIMER diagram (page 10)
Abb. 9

TO SET WEEKLY TIMER TO SET WEEKLY TIMER

OPERATION DETAILS OPERATION DETAILS

Panasonic U-10EA1E8 — TO SET WEEKLY TIMER TO SET WEEKLY TIMER diagram (page 10)
Abb. 10
  • Weekly timer is only applicable for wired remote control, press

MODE

  • for 3 seconds to select daily timer or weekly timer.
  • Daily timer and weekly timer could not be set at the same time.
  • Promotes energy saving by allowing you to set up to 6 timers in any given day.
  • Same timer program cannot be set on the same day.

AUTO AUTO

Panasonic U-10EA1E8 — AUTO AUTO diagram (page 10)
Abb. 11

MON TUE WED THU FRI SAT SUN ON

OFF / O

CZ-RT1

OFF / ON

TIMER/CLOCK

CZ-RT1

TEMP/ A/C No.

MODE

UP

TIMER/CLOCK

MODE

UP

MODE

UP

DOWN

DOWN

DOWN

AIR SWING ECONOMY

CHECK ODOUR WASH VENTILATION TEST RUN FILTER RESET

ECONOMY

CHECK ODOURWASH VE

Will light up if Timer operation is selected

1. Enter timer mode.
TIMER/CLOCK MODE SELECT UP DOWNSET CANCEL

6 different programs can be set in a day (1 ~ 6)

2. Select the day.

2 3 4 5 6

Indicate the selected day

ECONOMY

MON TUE WED THU FRI SAT SUN

3. The display will show the program for each of the selected day.

ON OFF

Time to be selected (Interval 10 minutes)

Modify Or Add Timer • Perform check timer operation to select the day. Repeat steps 4 to 8 to modify existing timer program, or add any new timer program.

OFF-Timer. To automatically switch “OFF” the unit.

ON-Timer. To automatically switch “ON” the unit.

Cancel Timer • Perform the step below to cancel the timer program for a particular day.

Day to be selected

1. Enter timer mode.
TIMER/CLOCK MODE SELECT UP DOWNSET CANCEL
1. Press

for 3 seconds to change the display to weekly timer.

MODE

2. Select the day.

Select days to run timer

2. Press

SELECT to enter day setting.

ECONOMY

3. Press to enter day setting.
3. Press to select your desired day. The selected day will be highlighted with . Press
4. Press to cancel the timer set.

SET to deselect or select mark. Repeat this step includes other day.

Disable Weekly Timer • To disable weekly timer setting, press

4. Press

SELECT to enter Timer 1.

MODE

5. Press to choose ON or OFF.
6. Press

SET to confi rm the selection.

Enable Weekly Timer • To enable previous weekly timer setting, press

MODE

7. Press to select your desired time. If you want to set together with your desired

UP

DOWN to select the temperature.

SET to confi rm the setting.

8. Press
  • Repeat steps 5 to 8 to set Timer 2 to 6, or press

CANCEL to cancel the related timers.

Show 7 more labels / short text on this page
Check Timer · Change Display · Select ON/OFF Timer · , then press · Select Timer · , then press · temperature, press
Page 11 of the Panasonic U-10EA1E8 user manual — FILTER
Seite 11 · Zum Vergrößern klicken
Seite 11

CARE & CLEANING CARE & CLEANING

Panasonic U-10EA1E8 — CARE & CLEANING CARE & CLEANING diagram (page 11)
Abb. 12
  • Switch off the power supply before cleaning.
  • Do not touch the aluminium fi n, sharp parts may cause injury.

CAUTION

CLEANING INSTRUCTIONS CLEANING INSTRUCTIONS

HINTS HINTS

  • Clean the fi lter regularly for best performance and to reduce power consumption.
  • Please consult your nearest dealer for seasonal inspection.
  • Do not use benzene, thinner or scouring powder.
  • Use only soap ( pH7) or neutral household detergent.
  • Do not use water hotter than 40°C.

Remove Air Filter Air Filter Installation

1 Press the knobs. Press the knobs.

CLOSE OPEN OPEN CLOSE

INDOOR UNIT INDOOR UNIT

Wipe the unit gently with a soft, dry cloth.

Insert the air fi lter to the tabs of the intake grille.

Panasonic U-10EA1E8 — CLOSE OPEN OPEN CLOSE diagram (page 11)
Abb. 13

Slowly bring up the intake grille.

OPEN CLOSE CLOSE OPEN

2 Slowly pull down Slowly pull down the intake grille. the intake grille.

3 Remove the air fi lter Remove the air fi lter from the tabs and pull it from the tabs and pull it downwards. downwards.

AIR FILTER AIR FILTER

Press the knobs to the CLOSE side.

Vacuum, wash and dry.

  • Air Filter Maintenance Cleaning is needed when:
  • lt is recommended to clean the air fi lter every 6 weeks.
  • After the air fi lter is cleaned, press FILTER RESET / FILTER RESET to reset.
  • Do not operate without an air fi lter.
  • Wash/rinse the air fi lter gently with water to avoid damage to the air fi lter surface.
  • Do not dry the part with a hair dryer or a stove.
  • Replace any damaged air fi lter.

AUTO FAN COOL DRY

FILTER RESET AUTO

“FILTER RESET” appears on the remote control display. (For wired remote control)

POWER

“FILTER” lights up on the indicator display. (For wireless remote control)

FILTER

Knob · Remove Remove

Page 12 of the Panasonic U-10EA1E8 user manual — TROUBLESHOOTING TROUBLESHOOTING
Seite 12 · Zum Vergrößern klicken
Seite 12

TROUBLESHOOTING TROUBLESHOOTING

Panasonic U-10EA1E8 — TROUBLESHOOTING TROUBLESHOOTING diagram (page 12)
Abb. 14

The following symptoms do not indicate malfunction. The following symptoms do not indicate malfunction.

Symptom Cause Mist emerges from indoor unit.• Condensation effect due to cooling process. Water fl owing sound during operation.• Refrigerant fl ow inside the unit. The room has a peculiar odour.• This may be due to damp smell emitted by the wall, carpet, furniture or clothing. Indoor fan stops occasionally during automatic fan speed setting.• This helps to remove the surrounding odours. Operation is delayed a few minutes after restart.• The delay is a protection to the unit’s compressor. Outdoor unit emits water/steam.• Condensation or evaporation occurs on pipes. Timer indicator is always on.• The timer setting repeats daily once set. Indoor fan stops occasionally during heating operation.• To avoid unintended cooling effect. Cracking sound can be heard during operation.• Changes of temperature cause the expansion/contraction of the unit. Unit switch to FAN operation and air become humid.• This happens when the room temperature reaches the set temperature, operation switches to FAN mode and the humidity increase. Outdoor unit emits noise during heating operation.• This is due to changes infl ow of refrigerant gas when operation stops and starts. Operation does not stop immediately after pressed the OFF/ON button.• Discharging heat is in process. Operation will stops automatically after approximately 60 seconds. Operation stops occasionally. (“DEFROST” appears on the remote control display)• The unit is in defrosting mode, and the melted frost is drained from the outdoor unit. Airfl ow does not start immediately after operation is started. (“PRE HEAT” appears on the remote control display)• The unit is warming up to provide warm air. Operation starts after power resumes.• Auto restart is in function and operates under previous setting. During dry mode, cold air blow out.• The unit is running cooling operation with low fan speed to dehumidify the room. Fan speed change occasionally during heating mode.• The room temperature has reached the remote control setting. When the room temperature drops again, the fan speed will resume to the remote control settings. Outdoor unit emits steam during heating mode.• This is due to defrost operation happens at the heat exchanger.
Page 13 of the Panasonic U-10EA1E8 user manual — TROUBLESHOOTING TROUBLESHOOTING
Seite 13 · Zum Vergrößern klicken
Seite 13
Panasonic U-10EA1E8 — TROUBLESHOOTING TROUBLESHOOTING diagram (page 13)
Abb. 15

Check the following before calling for servicing. Check the following before calling for servicing.

Symptom Symptom Check Check

Heating/Cooling operation is not working effi ciently.

  • Set the temperature correctly.
  • Close all doors and windows.
  • Clean or replace the fi lters.
  • Clear any obstruction at the air inlet and air outlet vents.

Heating mode cannot be operated. • The unit is forced to operate at cooling mode only in a non-living room, such as a computer room.

Noisy during operation. • Check if the unit has been installed at an incline or the intake grille is not closed properly.

Remote control does not work. (Wireless remote control display is dim or transmission signal is weak.)

  • Insert the batteries correctly.
  • Replace weak batteries.
  • The unit does not work.
  • Check if the circuit breaker is tripped.
  • Check if timers have been set.

The unit does not receive the signal from the remote control.

  • Make sure the receiver not obstructed.
  • Make sure the address is set correctly.
  • Make sure the remote control signal transmission is within the range.
  • Certain fl uorescent lights may interfere with signal transmitter. Please consult your nearest dealer.
  • The unit stopped and TIMER indicator blinks.
  • Turn OFF the power supply to reset the unit (TIMER indicator stop blinking).
  • Turn ON the power supply and restart the unit.
  • If TIMER indicator blinks again, please consult your nearest dealer.
Panasonic U-10EA1E8 — TROUBLESHOOTING TROUBLESHOOTING diagram (page 13)
Abb. 16
  • FOR SEASONAL INSPECTION AFTER EXTENDED FOR SEASONAL INSPECTION AFTER EXTENDED NON-USE NON-USE
  • Checking of remote control batteries (wireless remote control).
  • No obstruction at air inlet and air outlet vents.
  • Use Auto OFF/ON button to select Cooling/Heating operation, after 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents: Cooling: ≥ 8°C Heating: ≥ 14°C
  • NON SERVICEABLE CRITERIAS NON SERVICEABLE CRITERIAS TURN OFF POWER SUPPLY then CALL Authorized Distributor under the following conditions:
  • Abnormal noise during operation.
  • Water/foreign particles have entered the remote control.
  • Water leaks from Indoor unit.
  • Circuit breaker switches off frequently.
  • Power cord becomes unnaturally warm.
  • Switches or buttons are not functioning properly. FOR EXTENDED NON-USE FOR EXTENDED NON-USE
  • Activate Heat Mode for 2~3 hours to remove moisture left in the internal parts thoroughly to prevent mould growth.
  • Turn off the power supply.
  • Remove the remote control batteries (wireless remote control).
Reparatur

Fehlerbehebung

Häufige Probleme, wahrscheinliche Ursachen und Lösungen.

ProblemMögliche UrsacheAbhilfe
Mist emerges from indoor unit. p.12
Water fl owing sound during operation. p.12
The room has a peculiar odour. p.12
Indoor fan stops occasionally during automatic fan speed setting. p.12
Operation is delayed a few minutes after restart. p.12
Outdoor unit emits water/steam. p.12
Timer indicator is always on. p.12
Indoor fan stops occasionally during heating operation. p.12
Cracking sound can be heard during operation. p.12
Unit switch to FAN operation and air become humid. p.12
Outdoor unit emits noise during heating operation. p.12
Operation does not stop immediately after pressed the OFF/ON button. p.12
Operation stops occasionally. (“DEFROST” appears on the remote control display) p.12
Airfl ow does not start immediately after operation is started. (“PRE HEAT” appears on the remote control display) p.12
Operation starts after power resumes. p.12
During dry mode, cold air blow out. p.12
Fan speed change occasionally during heating mode. p.12
Outdoor unit emits steam during heating mode. p.12
Heating/Cooling operation is not working effi ciently. p.13
Heating mode cannot be operated. p.13
Noisy during operation. p.13
Remote control does not work. (Wireless remote control display is dim or transmission signal is weak.) p.13
The unit does not work. p.13
The unit does not receive the signal from the remote control. p.13
The unit stopped and TIMER indicator blinks. p.13

Frage zu Panasonic U-10EA1E8 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Panasonic U-10EA1E8

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Panasonic U-10EA1E8 PDF-Anleitung

112 Seiten·8 MB·Klimaanlage·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…