


When using a hood sufficient air flow is necessary. However large your kitchen may be, there is only so much air available in that space. Opening a door or window or the installation of a ventilation grid close to the hood insures a good quality of air flow. Insufficient air flow will impair the extraction efficiency of your hood immensely.
① switch on / off ② decrease speed levels ⑤ and ⑥ LED indication speed level ③ increase speed levels ④ illumination
Insufficient air flow can cause reflux from other air ducts such as chimneys or combustion appliances. When using a cooker hood and appliances using energy other than electrical in the same space, the pressure in the room may not surpass 4 Pa (= 0.04mBar).
Switch on – switch off To switch the motor on push button ①. The hood will always resume the level it was previously switched off in.
Switch off with 10 minute delay: Press button ① once. The first green LED blinks, the other LED’s remain lit up according to the level in use. After 10 minutes motor and illumination switch off automatically.
Switch off without delay: Push button ① twice.
Auto-Stop To avoid that the hood will function during a too long period, it will switch off automatically after 3 hours (when no changes to the controls have been made). Motor and lighting will turn off automatically.
Levels of intensity To decrease speed levels push button ②. To increase speed levels push button ③. Three green LED’s ⑤ indicate level 1 to 3, one red LED ⑥ indicates the level ‘POWER’.
‘POWER’ is only used in case of excessive formation of smoke, fumes or odours. Taking into account the large volume of air which is extracted from the room at this level, it’s use should be limited.
‘POWER’ automatically reverts to level 3 after 20 minutes.
Illumination An exteral lightning can be connected to the hood
Use · Operation

Programming the remote control
The remote control for hood and hob are preinstalled and ready for use. Only when te remote control needs to be reprogrammed (interaction with other controls)act as in the following.
Maintenance of the grease filter The hood contains one metal filter which should be cleaned twice a month.
Grease filter indication After 20 cooking hours, the 4 LEDs will start to blink during 5 minutes, this indicates that the grease filter has to be cleaned. When replacing the cleaned filter, you have to reset the hood by pushing the – button during 5 seconds . If you don’t reset, the LED lights will continu blinking.We advise you to clean your filter twice a month for an optimal operation.
Determine the code used: Simultaneously press on/off + the key with the lighting symbol. The lamp flashes as well as the selected code (there are 10 code options in total).
the sun for 3 seconds until the lamp is flash- ing. After this the lamp as well as the selected code will flash. Repeat this step until you have reached the required code (there are 10 code options in total). b. Simultaneously press + lamp of the roof cover
Access to the filter Take hold of the right and left side of the plate (a) and pull down simultaneously. Remove the filter (b) by taking hold of its hook and pulling down.
control until the second green LED is blinking. c. Press the key with the sun on the remote con-

trol within 10 seconds to confirm the settings. The cooker hood and the remote control are now in line with each other.
NOVY key: You can switch on the ambient lighting using the NOVY key (figure 5).
Technical information: - Power supply: (2xAAA) batteries - Frequence: 433.92Mhz - Numbre of codes: 10 - Worktemperature: 0-50°C - Dimensions: 110 x 50 x 19mm
The stainless steel surfaces can be treated with Novy Inoxcleaner (906.060) after cleaning.
Maintenance
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.