The controls are on the rotating valve.

Air supply When using a hood sufficient air flow is necessary. However large your kitchen may be, there is only so much air available in that space. Opening a door or window or the installation a ventilation grid close to the hood insures a good quality of air flow. Insufficient air flow will impair the extraction efficiency of your hood immensely.
Open the glass cover by turning it towards you. ① switch on / off ② decrease speed levels ③ increase speed levels ④ illumination ⑤ and ⑥ LED indication speed levels
Insufficient air flow can cause reflux from other air ducts such as chimneys or combustion appliances. When using a cooker hood and appliances using energy other than electrical in the same space, the pressure in the room may not surpass 4 Pa (= 0.04mBar).
Switch on – switch off To switch the motor on push button ①. The hood will always resume the level it was previously switched off in.
Switch off with 10 minute delay: Press button ① once. The first green LED blinks, the other LED’s remain lit up according to the level in use. After 10 minutes motor and illumination switch off automatically.
Switch off without delay: Push button ① twice.
Levels of intensity To decrease speed levels push button ②. To increase speed levels push button ⑤. Three green LED’s ③ indicate level 1 to 3, one red LED ④ indicates the level ‘POWER’. POWER’ is only used in case of excessive formation of smoke, fumes or odours. Taking into account the large volume of air which is extracted from the room at this level, it’s use should be limited. ‘POWER’ automatically reverts to level 3 after 6 minutes.
A self-rectifying thermal contact makes sure that the motor is switched off when overheated. The motor will switch on again after is has cooled down. The cause of the overheating needs to be determined. This may be, for example, that the contents of the pan have caught fire, the motor fan is blocked or an object is (partly) closing off the exhaust opening.
Auto-Stop To avoid that the hood will function during a too long period, it will switch off automatically after 3 hours (when no changes to the controls have been made). Motor and lighting will turn off automatically.
Use

Illumination To activate the lights press button ⑥. The lights will switch on at full power. Lighting can be activated independently from the motor.
Access to the filter:

Recirculation (option) If recirculation has been chosen, this is to be programmed one time. This programming activates the cleaning indication of the Monoblock recirculation filter and changes the switch-off delay time.
Open the rotating valve (A). Protect the hob. You can take the grease filter (B) from the hood by pulling the handle on the filter. The filter will come down.
Deactivate the programming (do the deactivate programming with the motor turned on): Simultaneously press + and – for 5 sec. until the third green LED flashes 3 times. Attention! This is not recommended for a cooker hood with recirculation.
Grease filter The cooker hood contains 2, 3 or 4 metal grease filters, dependent on the type number.
Grease filter indication: Indication: 4 flashing LEDs After 20 cooking hours, the 4 LEDs will start to blink during 5 minutes, this indicates that the grease filter has to be cleaned. When replacing the cleaned filter, you have to reset the hood by pushing the – button during 5 seconds. If you don’t reset, the LED lights will continu blinking. We advise you to clean your filter twice a month for an optimal operation.
Maintenance

Recirculation (option) If you have chosen for recirculation, please follow the instructions below.
Replacement of the fluorescent lighting
Replacement of the led ligths
Cleaning indication: Indication: red LED lights up The red LED will light up after 200 working hours (time to regenerate the Monoblock recirculation filter). The recirculation filter is to be found behind the grease filter.
In the event of a malfunction, you can contact your (kitchen) supplier and/or the Novy Customer Service Department. In order for the Customer Service Department to reply quickly and precisely you must to tell them which type of extraction hood you have. The model number can be found on a sticker on the interior of the extraction hood. This is visible as soon as you take the filter out of the extraction hood. You can write down the model number here: Model number:
Electrical output: electrical cord + plug with ground. To be plugged into socket with ground. Check for compatibility with information on type plate (behind filter). Socket must be within reach. Changes or replacement of the electrical cord should be performed by a professional only.
Reset the Monoblock recirculation filter: The cooker hood (motor) must be running! Simultaneously press + and – for 5 sec. until the red indicator lamp flashes 3 times for confirmation. If the programming is not carried out, the programming is automatically set after the chimney hood has been switched on 10 times.
Maintenance of the hood Please allow the lights to cool down sufficiently before cleaning the hood. Use a soft, wet cloth and a mild detergent to clean the hood. Never use aggressive, abrasive detergents or sponges. Bleach will damage stainless steel. The stainless steel surfaces can be treated with Novy Inoxcleaner (906.060) after cleaning.
Electrical connection

Afmetingen - Dimensions - Abmessungen - Dimensions



Afmetingen - Dimensions - Abmessungen - Dimensions


Elektrisch schema - Schéma électrique - Elektrischer Schaltplan - Electrical scheme





Certificat de garantie hottes NOVY Garantie Zertifikat NOVY Dunsthauben Warrenty certificate NOVY hoods
Voir au dos Sehen Sie die RuckSeite
Zie achterkant · See back
In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.