Air supply When using a hood sufficient air flow is necessary. However large your kitchen may be, there is only so much air available in that space. Opening a door or window or the installation of a ventilation grid close to the hood insures a good quality of air flow. Insufficient air flow will impair the extraction efficiency of your hood immensely.
① switch on / off ② decrease speed levels ⑤ and ⑥ speed indicator lamps ③ increase speed levels ④ illumination
Switch on – switch off To switch the motor on push button ①. The hood will always resume the level it was previously switched off in.
Insufficient air flow can cause reflux from other air ducts such as chimneys or combustion appliances. When using a cooker hood and appliances using energy other than electrical in the same space, the pressure in the room may not surpass 4 Pa (= 0.04mBar).
Auto-Stop To avoid that the hood will function during a too long period, it will switch off automatically after 3 hours (when no changes to the controls have been made). Only the motor will turn off automatically. The lighting will stay on.
Switch off with 10 minute delay: Press button ① once. The first greenspeed indicator lamp blinks, the other speed indicator lamps remain lit up according to the level in use. After 10 minutes motor and illumination switch off automatically.
Switch off without delay: Push button ① twice.
Levels of intensity To decrease speed levels push button ②. To increase speed levels push button ③. Three green speed indicator lamps ⑤ indicate level 1 to 3, one red speed indicator lamp ⑥ indicates the level ‘POWER’.
‘POWER’ is only used in case of excessive formation of smoke, fumes or odours. Taking into account the large volume of air which is extracted from the room at this level, it’s use should be limited.
‘POWER’ automatically reverts to level 3 after 6minutes.
A self-rectifying thermal contact makes sure that the motor is switched off when overheated. The motor will switch on again after is has cooled down. The cause of the overheating needs to be determined. This may be, for example, that the contents of the pan have caught fire, the motor
Use · Operation

fan is blocked or an object is (partly) closing off the exhaust opening.
be followed. If not an increased fire hazard may occur.
Lighting Press key ④ to switch the lighting on or off. The LED lighting has a soft on/soft off mode, which means that the lighting will evenly go on and off. When switching on the lighting, this will always light up with full power and it can also be used when the fan is off.
Maintenance of the hood Please allow the lights to cool down sufficiently before cleaning the hood. Use a soft, wet cloth and a mild detergent to clean the hood. Never use aggressive, abrasive detergents or sponges. Bleach will damage stainless steel.
Dimming LED lighting: When the LED lighting has been switched on, it can be dimmed by keeping key ④ pressed.
The stainless steel surfaces can be treated with Novy Inoxcleaner (906.060) after cleaning.
Please allow the lights to cool down sufficiently before touching them. Cover and protect delicate surfaces underneath the hood when changing lamps. The hood needs to be disconnected from the current before proceeding.
Maintenance of the grease filter The hood contains one or 2 metal filters (according to the model) which should be cleaned twice a month.
Grease filter indication After 20 cooking hours, the 4 speed indicator lamps will start to blink during 5 minutes, this indicates that the grease filter has to be cleaned. When replacing the cleaned filter, you have to reset the hood by pushing the – button during 5 seconds . If you don’t reset, the speed indicator lamps will continu blinking.

Access to the filter Take hold of the right and left side of the plate (a) an pull down simultaneously. Remove the filter (b) by taking hold of its hook and by pulling it down.


replaced. Disconnect by means of releasing the lock, by applying light pressure while at the same time pulling away.
Replacing the lamps · Maintenance

B. Next, remove the LED to be replaced by
making a gentle rotating movement to the left.

Electrical output: electrical cord + plug with ground. To be plugged into socket with ground. Check for compatibility with information on type plate (behind filter). Socket must be within reach. Changes or replacement of the electrical cord should be performed by a professional only.
the LED light is locked. C. Connect the power cable. D. Put back the cover and tighten the screws.
Then close the bottom plate.

Electrical connection

Afmetingen - Dimensions - Abmessungen - Dimensions



7640 - 7645 · 7650 - 7655 · 7660 - 7665

Elektrisch schema - Schéma électrique - Elektrischer Schaltplan - Electrical scheme
7640 - 7650 - 7660


7645 - 7655 - 7665

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.