Air supply When using a hood sufficient air flow is necessary. However large your kitchen may be, there is only so much air available in that space. Opening a door or window or the installation of a ventilation grid close to the hood insures a good quality of air flow. Insufficient air flow will impair the extraction efficiency of your hood immensely.
① switch on / off ② decrease speed levels ③ and ④ Speed indicator lamps ⑤ increase speed levels ⑥ illumination
Switch on – switch off To switch the motor on push button ①. The hood will always resume the level it was previously switched off in.
Insufficient air flow can cause reflux from other air ducts such as chimneys or combustion appliances. When using a cooker hood and appliances using energy other than electrical in the same space, the pressure in the room may not surpass 4 Pa (= 0.04mBar).
Switch off with 10 minute delay: Press button ① once. The first green speed indicator lamp blinks, the other speed indicator lamps remain lit up according to the level in use. After 10 minutes motor and illumination switch off automatically.
Switch off without delay: Push button ① twice.
Auto-Stop To avoid that the hood will function during a too long period, it will switch off automatically after 3 hours (when no changes to the controls have been made). Only the motor will turn off automatically. The lighting will stay on.
Levels of intensity To decrease speed levels push button ②. To increase speed levels push button ⑤. Three green speed indicator lamps ③ indicate level 1 to 3, one red speed indicator lamp ④ indicates the level ‘POWER’.
‘POWER’ is only used in case of excessive formation of smoke, fumes or odours. Taking into account the large volume of air which is extracted from the room at this level, it’s use should be limited.
‘POWER’ automatically reverts to level 3 after 6 minutes.
A self-rectifying thermal contact makes sure that the motor is switched off when overheated. The motor will switch on again after is has cooled down. The cause of the overheating needs to be determined. This may be, for example, that the contents of the pan have caught fire, the motor fan is blocked or an object is (partly) closing off the exhaust opening.
Use · Operation

Programming the remote control
The remote control for hood and hob are preinstalled and ready for use. Only when te remote control needs to be reprogrammed (interaction with other controls)act as in the following.
Maintenance of the grease filter The hood contains two metal filters which should be cleaned twice a month.
Grease filter indication After 20 cooking hours, the 4 speed indicator lamps will start to blink during 5 minutes, this indicates that the grease filter has to be cleaned. When replacing the cleaned filter, you have to reset the hood by pushing the – button during 5 seconds . If you don’t reset, the speed indicator lamps will continu blinking. We advise you to clean your filter twice a month for an optimal operation.
Determine the code used: Simultaneously press on/off + the key with the sun. The lamp flashes as well as the selected code (there are 10 code options in total).
the sun for 3 seconds until the lamp is flash- ing. After this the lamp as well as the selected code will flash. Repeat this step until you have reached the required code (there are 10 code options in total).
Access to the filter Take hold of the right and left side of the plate (a) and pull down simultaneously. Remove the filter (b) by taking hold of its hook and pulling down.
b. Simultaneously press + lamp of the roof cover
control until the second green speed indicator lamp is blinking.

c. Press the key with the sun on the remote con-
trol within 10 seconds to confirm the settings. The cooker hood and the remote control are now in line with each other.

Recirculation (option) If you have chosen for recirculation, please follow the instructions below.
NOVY key: You can switch on the ambient lighting using the NOVY key (figure 5).
Cleaning indication: The red speed indicator lamp will light up after 200 working hours (time to regenerate the used carbon filter).
Technical information: - Power supply: (2xAAA) batteries - Frequence: 433.92Mhz - Numbre of codes: 10 - Worktemperature: 0-50°C - Dimensions: 110 x 50 x 19mm
Maintenance

Reprogramming: Press + and – simultaneously for 5 seconds, the red speed indicator lamp flashed 3 times for confirmation (if this programming is not done, the program will be set automatically after having switched on the device 10 times).
Deactivate the program: Simultaneously press + and – for 5 sec. until the third green speed indicator lamp flashes 3 times.
Maintenance of the hood Please allow the lights to cool down sufficiently before cleaning the hood. Use a soft, wet cloth and a mild detergent to clean the hood. Never use aggressive, abrasive detergents or sponges. Bleach will damage stainless steel.
The stainless steel surfaces can be treated with Novy Inoxcleaner (906.060) after cleaning.
Electrical output: electrical cord + plug with ground. To be plugged into socket with ground. Check for compatibility with information on type plate (behind filter). Socket must be within reach. Changes or replacement of the electrical cord should be performed by a professional only.
Electrical connection

Afmetingen - Dimensions - Abmessungen - Dimensions


6838 - 6839 · 6848 - 6849

Elektrisch schema - Schéma électrique - Elektrischer Schaltplan - Electrical scheme





Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.