Benutzeranleitung / Produktwartung 00638A2 des Produzenten AcuRite
Zur Seite of 16
SAVE THIS MANU AL FOR FUTURE REFERENCE. Questions? Contact Cust omer Suppor t at ( 8 77) 22 1 - 1 25 2 or visit www . AcuRite .com. CONTENTS Unpac king Instr uctions ........... 2 P ackage Contents .................. 2 Product R egistration ..........
2 Congratulations on y our new A cuRite product. T o ensure t he best possible product perf ormance, please read t his manual in its entirety and retain it for future ref erence. Unpac king Ins tructions Remo v e the protective lm t hat is applied to the LCD screen prior to using this product.
3 Features & Benets 3-in-1 SENSOR 1 . T emperature & Humidity Sensors (internal) 2. Release Lev er for Batter y Access 3. Mounting Point 4. Wind Speed Anemometer 5.
4 Features & Benets Display Unit 6 1 31 30 2 3 4 5 18 17 19 20 21 8 7 9 10 11 12 13 15 14 16 22 23 26 25 24 29 28 27 32 33 34.
5 DISPL AY UNIT 1 . Date 2. Low Battery Indicat or 3. Atomic Cloc k Maintains time with split-second accuracy and automatically updates for daylight saving time. 4. Atomic Cloc k Signal Strengt h 5. Selected Time Zone 6. Barometric Pressure Arrow icon indicates the direction the pressure is trending.
6 SETUP Set the A-B-C Switc h The A -B-C switc h is located inside the batt er y compar tment. It can be set to A , B or C. How ev er , you must select the same letter c hoices for bot h the sensor and the displa y unit in order for the units to sync hronize.
7 PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENT ALL Y SAFE WAY AND IN ACCORDANCE WITH Y OUR LOCAL LAWS AND REGUL ATIONS. BA TTERY SAFETY : Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time.
8 Atomic Cloc k AcuRite atomic cloc ks use a radio-controlled signal to synchronize to t he correct time broadcast by the National Institute of S tandards and T echnology (NIST) Radio Station WWVB, locat ed near For t Collins, Colorado. WWVB broadcasts the current time and dat e with split-second accuracy .
9 Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding envir onmental conditions. Proper placement of bot h the display unit and t he sensor are critical t o the accuracy and per for mance of this product. Display Unit Placement Place the displa y unit in a dr y area free of dir t and dust.
10 3-in-1 Sensor Installation Guidelines INSTALLATION HEIGHT Mount t he sensor at least 5 fee t (1 .5 met ers) of f the ground (higher is better for wind measurement) in an open area.
11 Using The Weat her Center Learning Mode Self-Calibrating Forecasting use a unique algorithm t o analyze c hanges in pressure o v er a time period (called Lear ning Mode) to deter mine your altitude. Af ter 1 4 days, t he Learning Mode icon disappears from the displa y screen.
12 High & Low Records The “MIN/MAX” button displays minimum and maximum recordings for outdoor and indoor temperature and humidity . T o view the MINIMUM temperature and humidity readings, press and release the “MIN/MAX” button until the “MIN” icon appears on t he display next to t he low r ecords.
13 Problem Possible Solution Outdoor temperature is ashing or showing dashes Flashing of the outdoor t emperature may be an indication of wireless inter ference. • Make sure the A -B-C switc h in the batt er y compar tments of bot h the displa y unit and sensor are switched t o the same lett er .
14 Care & Maintenance Display Unit Car e Clean with a sof t, dam p cloth. Do no t use caustic cleaners or abrasiv es. K eep away from dust, dirt and moisture. Clean ventilation por ts regularly wit h a gentle puf f of air . 3-in-1 Sensor Care Clean the Sensor Clean with a sof t, dam p cloth.
15 At AcuRite, we proudly uphold our commitment to quality tec hnology . Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase.
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology . Visit www .
Ein wichtiger Punkt beim Kauf des Geräts AcuRite 00638A2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie AcuRite 00638A2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für AcuRite 00638A2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von AcuRite 00638A2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über AcuRite 00638A2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon AcuRite 00638A2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von AcuRite 00638A2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit AcuRite 00638A2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei AcuRite 00638A2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.