Benutzeranleitung / Produktwartung DVA-08K des Produzenten Bosch Appliances
Zur Seite of 68
RAID Subsystem DVA-08K DVA-08K SCSI Premium Series en Installation Manual.
.
RAID Subsyst em DVA-08K | Installation Manual Table of Contents | en 3 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 T able of Contents 1 Warnings and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 en | Table of Contents RAID Subsys tem DV A -08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 5 Subsystem Connection and Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAID Subsyst em DVA-08K | Installation Manual Warnings and Cer tifications | en 5 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 1 W arnings and Cer tifications 1.1 W arning A shielded power cord is requir ed in order to meet FCC emission limits and also to preve nt interference to nearby radi o and television reception .
6 en | Warnings and Cer tifications RAID Subsystem D VA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems turning the equipment off and on, the user is encouraged to try to correc t the interference by one or more of the follo wing measures: • Reorient or relocate the receiving antenna.
RAID Subsyst em DVA-08K | Installation Manual Introduction | en 7 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 2 Introduction This manual covers the DVA-08K series of RAID subsystems.
8 en | Intr oduction RAID Subsy stem DV A -08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems Channels: The SCSI ID/LUN mapping method en ables users to associate a storage volume with multiple IDs or LUNs on the host channels.
RAID Subsyst em DVA-08K | Installation Manual Introduction | en 9 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 2.2 Enclosure Chassis 2.2.1 Chassis Overview The RAID subsystem comes in a 2U metal chas sis. A backplane board divides th e enclosure internally into front and rear sections.
10 en | Intr oduction RAID Subsy stem DV A -08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems Fig. 2.3 Fro n t V i e w The front panel is designed to a ccommodate the fol.
RAID Subsyst em DVA-08K | Installation Manual Introduction | en 11 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 • BBU module: A BBU provides the protective im plementation to cached data; and, unless deselected when purchasing the subsystems, is installed into the module slot located at the upper left corner of the controller module.
12 en | Intr oduction RAID Subsy stem DV A -08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 2.3 Subsy stem Components All the active components on the subsystem can be accessed through either the front or rear panel. The modular design of the active comp onents facilitates their easy installation and removal.
RAID Subsyst em DVA-08K | Installation Manual Introduction | en 13 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 2.3.2 Drive Trays The subsystem comes with 8 drive trays (see Figure 2.9 ) designed to accommodate separately purchased standard 1-inch pitch, 3.
14 en | Intr oduction RAID Subsy stem DV A -08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems • Ethernet Por t All controller modules on the subsys tems co me with a single 10/100BasedT RJ-45 Ether- net port.
RAID Subsyst em DVA-08K | Installation Manual Introduction | en 15 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 2.3.5 Power Supply Units The SATA-based RAID subsystems are equipped with two (2) redundant, hot-swappable, 2U, 350W power supply unit (PSUs) modules.
16 en | Intr oduction RAID Subsy stem DV A -08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems Fig. 2.13 T op View of a Cooling F an Module Advanced Fault-Preventative Ope.
RAID Subsyst em DVA-08K | Installation Manual Introduction | en 17 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 2. 4 S ub sys te m M on ito r in g The SATA-based RAID subsystem comes with a number of different mo nitoring methods that provide you with continual updates on the statu s of the system and individual components.
18 en | Intr oduction RAID Subsy stem DV A -08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 2.5 Ho t-Swappable Components 2.
RAID Subsyst em DVA-08K | Installation Manual Hardware Installation | en 19 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 3 Hardwar e Installation This chapter gives detailed instructions on how to install the subsystem.
20 en | Hardware Installation RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 3.2 Saf e ty Precautions 3.2.1 Precautions and Instructions • Be sure the correct power range (100-120 or 220-240VAC) is supplied by your rack cabi- net, UPS device, or power outlet.
RAID Subsyst em DVA-08K | Installation Manual Hardware Installation | en 21 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 • Install or replace the BBU module only with a BBU module supplied by your subsystem vendor. Use of battery cells provided by another source will void our warranty.
22 en | Hardware Installation RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 3.3 G eneral Installation Proce d ure The following instructions can save installation time. Detailed, i llustrated instructions for each component are given in the following sections.
RAID Subsyst em DVA-08K | Installation Manual Hardware Installation | en 23 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 3.5 Rackmounting The subsystem is easily insta lled into a standard 19-inch ra ck cabinet using the mounting holes on the sides of chassis.
24 en | Hardware Installation RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 3.6 Driv e T r ay Installation Once the hard drives have been in stalled in the drive trays, the dr ive trays can be installed into the subsystem.
RAID Subsyst em DVA-08K | Installation Manual Hardware Installation | en 25 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 Fig. 3.5 Drive T ray K ey-lock Ro tation 6. Once all drive trays are installed, the RAID subsystem will poll the drive channels and rec- ognize the drives and scan them in automatically.
26 en | Subsystem Monit or ing RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 4 Subsystem Monit oring This chapter provides information on how to monitor the subsystem.
RAID Subsyst em DVA-08K | Installation Manual Subsystem Monitoring | en 27 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 4.2 Status-indicating LEDs 4.2.1 Brief Overview of the LED s The following devices come with LEDs that inform subsystem managers about the operational status of the component on which they are mounted.
28 en | Subsystem Monit or ing RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 4.2.2 Drive Tray LEDs Two LED indicators are located on the right side of each drive tray. (See Figure 4.1 ) Ref er to Table 4.
RAID Subsyst em DVA-08K | Installation Manual Subsystem Monitoring | en 29 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 4.2.4 Ethernet Port LEDs The subsystem comes with a RS-232C audio jack serial port that can be used to assign a per- manent IP to the subsystems.
30 en | Subsystem Monit or ing RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 4.2.5 BBU Module LED The BBU module has an LE D on its faceplate. (See Figure 4.4 ) The function is the same as the fifth LED on the controller module .
RAID Subsyst em DVA-08K | Installation Manual Subsystem Monitoring | en 31 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 4.2.8 Cooling Fan Module LED The cooling fan module comes with a single status-indicating re d LED shown in Figure 4.7 . LED definitions are given in Figure 4.
32 en | Subsystem Monit or ing RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 4.3 Audible Alarm Different subsystem environmental and operation al parameters (i.e., temperature, etc.) have been assigned a range of values between which th ey can fluctuate.
RAID Subsyst em DVA-08K | Installation Manual Subsystem Monitoring | en 33 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 4.3.2 Failed Devi ces The audible alarm will be triggered if any of the following devices fail: • Cooling fan modules • PSU modules • BBU modules • Hard driv es • Components on the RAID controller 4.
34 en | Subsystem Connection and Operation RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 5 Subsystem Connection and Operation This chapter introdu.
RAID Subsyst em DVA-08K | Installation Manual Subsystem Connection and Operation | en 35 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 5.2 SCSI Connection Over view The SCSI host ports conne ct to SCSI-320 host adapters (HBA) that comply with 3 20MB/s transfer rate and SCSI-3 prot ocol, best capable of 64-bit/1 33MHz PCI operation.
36 en | Subsystem Connection and Operation RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 5.2.3 SCSI Termination Correct SCSI termination procedures require that the last device on the SCSI bus be termi- nated.
RAID Subsyst em DVA-08K | Installation Manual Subsystem Connection and Operation | en 37 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 5.3 Host Connection T opology Fig. 5.2 Cascaded Subsyst ems Connected t o T wo Host Comput ers In the example shown in Figure 5.
38 en | Subsystem Connection and Operation RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 5.4 P ower On After installing all the compon ents in the.
RAID Subsyst em DVA-08K | Installation Manual Subsystem Connection and Operation | en 39 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 5.4.4 Power On Status Check Once the subsystem has been .
40 en | Subsystem Connection and Operation RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems This screen appears when the PSUs are turned on. Proceeding with controller self-test. Self-test completed. Verifying installed cache memory.
RAID Subsyst em DVA-08K | Installation Manual Subsystem Connection and Operation | en 41 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 5. 5 Powe r O f f P roc ed ur e If you wish to power down the subsys tem, please follow these steps: 1. Stop I/O access to the system Stop all I/O accesses from the host comput ers to the subsystem.
42 en | Subsystem Maint enance RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 6 Subsystem Maint enance Constant monitoring and maintenance of your SATA-based subsystems will minimize the chance of system downtime and preserve the wo rking integrity of the system for a longer period of time.
RAID Subsyst e m DVA-08K | Installation Manual Subsy stem Maintenance | en 43 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 6.2 Replacing Controller Module Components 6.
44 en | Subsystem Maint enance RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 6.2.4 Replacing the Controller Module 1. Remove the failed controller module. 2. Install a DIMM module on the new controller module.
RAID Subsyst e m DVA-08K | Installation Manual Subsy stem Maintenance | en 45 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 6.3 Replacing or Upgrading Memor y Modules 6.3.1 Memory Module Installation Overview • The subsystems come with a pre-in stalled 256MB (or above) DDR RAM DIMM module on the controller.
46 en | Subsystem Maint enance RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems Fig. 6.2 Push Back the Module Clips on the Sides of the DIMM Sock e t 3. Gently retrieve the DIMM modu le out of the DIMM socket.
RAID Subsyst e m DVA-08K | Installation Manual Subsy stem Maintenance | en 47 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 6.4 Replacing a F aulty BBU To replace a faulty BBU, please follow these steps: 1. Remove the faulty BBU module from the cha ssis.
48 en | Subsystem Maint enance RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems The screw is located below the extraction leve r, beside the L ED indicator, and can be hid- den from sight. Fig. 6.4 PSU Parts Identification 4.
RAID Subsyst e m DVA-08K | Installation Manual Subsy stem Maintenance | en 49 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 7. Insert the new PSU module into the subsys tem: Once the previously removed c ooling module has been installed, insert the new PSU module into the subsys tem.
50 en | Subsystem Maint enance RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 6.6 Replacing a F ailed Cooling F an Module 6.
RAID Subsyst e m DVA-08K | Installation Manual Subsy stem Maintenance | en 51 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 6.7 Drive T ray Maintenance 6.7.1 Notes on Hard Drive Maintenance • Hot-swappable drive trays: The drive trays are a ll hot-swappable.
52 en | Subsystem Maint enance RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems Hard drives for the subsystem can be purchase d separately. When purchasing the hard drives, the following factors should be considered: • Capacity (MB/GB): Use drives with the same capacity.
RAID Subsyst e m DVA-08K | Installation Manual Subsy stem Maintenance | en 53 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 7. Place the SATA hard drive into the drive tray (as shown in Figure 6.10 ) making sure that the hard drive is oriented in such a way that the drive’s SATA connector is facing the back of the drive tray.
54 en | Appendix: T echnical Specif ications RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 7 Appendix: T e chnical Specifications Environmental Sp.
RAID Subsyst em DVA-08K | Installation Manual Appendix: T echnical Specifications | en 55 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 Safety Requirements UL CB Shock Half-sine Operating: 5G peak, 11ms duration Non-operating: 15G, 11ms, half-sine Vibration Operating 0.
56 en | Appendix: T echnical Specif ications RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 7.1 Contr oller Specifications 7.
RAID Subsyst em DVA-08K | Installation Manual Appendix: T echnical Specifications | en 57 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 7.2 Drive T ray Specifications 7.3 Po wer Supply Specifications Specifications Height 28mm Width 110mm Depth 218.
58 en | Appendix: T echnical Specif ications RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 7.4 Cooling Module Specifications 7.5 RAID Management Specifications Speed High or low rotation sp eed controlled by firmware Max.
RAID Subsyst em DVA-08K | Installation Manual Appendix: T echnical Specifications | en 59 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 7.6 F a ult T olerance Management Specifications SATA d.
60 en | Appendix: Spare Par ts and Accessories RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 8 Appendix: Spare Par ts and Accessories 8.
RAID Subsyst em DVA-08K | Installation Manual Appendix: Spare Par ts and Accessories | en 61 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 8.2 Accessories and Optional Items A number of accessory ite ms ar e available for the RAID subsystem.
62 en | Appendix: Pinouts RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 9 Appendix: Pinouts 9.1 SCSI Port : VHDCI Connector Pinouts The SCSI port connector pinouts comply with specification s in T10 Working Draft, Project 1365D, SCSI Parallel Interface-4.
RAID Subsyst em DVA-08K | Installation Manual Appendix: Pinouts | en 63 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 9.2 COM1 Cable: DB9 and Audio Jack Pinouts Fig. 9.1 Serial Port Cable CN1 and CN2 Connectors 32 SD9+ 66 SD9- 33 SD10+ 6 7 SD10- 34 SD11+ 6 8 SD11- Pin Name Pin Name Ta b l e 9 .
64 en | Appendix: Pinouts RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems 9.3 Null Modem 9.4 Ethernet Port Pinouts Fig. 9.2 L AN Por t Pinouts 9.5 Main P ower IEC-type receptacle. Swap Pin 2 and Pin 3 Swap Pin 4 and Pin 6 Swap Pin 7 and Pin 8 Ta b l e 9 .
RAID Subsyst em DVA-08K | Installation Manual Index | en 65 Bosch Secu rity Syst ems F .01U.027.797 | V2 | 2008.08 10 Inde x A airflow 20 , 58 airflow clearance 20 ambient Temperature 38 array identif.
66 en | Index RAID Subsyst em DVA-08K | Installation Manual F .01U.027.797 | V2 | 2008.08 Bosch Security Sy stems T terminal emulation program 17 terminal management 14 threshold values 32 U under cha.
.
Bosch Security Systems Robert-Koch-Straße 100 D-85521 Ottobrunn Germany Telefon +49 (89) 6290-0 Fax +49 (89) 6290-1020 www.bosch-securitysystems.com © Bosch Security Systems, 2008.
Ein wichtiger Punkt beim Kauf des Geräts Bosch Appliances DVA-08K (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bosch Appliances DVA-08K noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bosch Appliances DVA-08K - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bosch Appliances DVA-08K reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bosch Appliances DVA-08K erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bosch Appliances DVA-08K besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bosch Appliances DVA-08K verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bosch Appliances DVA-08K. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bosch Appliances DVA-08K gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.