Control Panel D9412GV4/D7412GV4 v2.00 en UL Installation Instructions.
.
Table of contents 1 Introduction 4 1.1 About documentation 4 1.2 Determine Bosch Security Systems, Inc. Product Manufacturing Dates 4 2 Installation 5 2.1 Installation Preparation 5 2.2 Enclosure Options 5 2.3 Mounting Enclosure 5 2.4 Installing the Control Panel 6 2.
Introduction About documentation Copyright This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Installation Installation Preparation This section contains a general installation procedure and refers to other sections of the document for detailed instructions.
i Notice! Electromagnetic interference (EMI) can cause problems on long wire runs. Figure 2.1: Enclosure Mounting Callout - Description 1 - Point chart label 2 - Mounting skirt hooks (2) 3 - Module mo.
Connecting Earth Ground Terminal 10 To help prevent damage from electrostatic charges or other transient electrical surges, connect the system to earth ground at Terminal 10 before making other connections. Recommended earth ground references are a grounding rod or a cold water pipe.
Figure 2.2: Ground Fault Detect (S4) Callout - Description 1 - S4 Locked (Closed). Control panels detects ground faults. 2 - S4 Unlocked (Open). Control panel does not detect ground faults.
Figure 2.3: Reset Pin Callout - Description 1 - Reset pin locked (closed) 2 - Reset pin normal (open) Control Panel Installation | en 9 Bosch Security Systens, Inc.
Diagrams Faceplates Figure 3.1: Faceplates Callout - Description Callout - Description 1 - Charging status LED (yellow) 8 - Ring 2 - Low battery LED (red) 9 - Operation monitor LED (green) 3 - Color-c.
Power Supply Side Wiring Diagrams D9412GV4/D7412GV4 Power Supply Side System Wiring Diagram (Power and Phone) Figure 3.2: Side System Wiring Diagram Callout - Description Callout - Description 1 - If required by local AHJ, connect D113 Battery Lead Supervision Module.
i Notice! For UL Certified accounts, additional power can be obtained using only a UL Listed auxiliary 12.0 VDC regulated, power-limited power supply. i Notice! All terminals accept for Outputs A, B, and C (Terminals 6, 7 and 8) are supervised. D9412GV4/D7412GV4 Input Points and Peripheral Devices System Wiring Diagram Figure 3.
i Notice! For D129, use zero retard except for waterflow devices. All external connections except Terminal 5 (battery positive) are power limited. Control Panel Diagrams | en 13 Bosch Security Systens, Inc. UL Installation Instructions 2012.12 | 02 | F.
SDI Devices Wiring Diagrams D9412GV4 SDI and Zonex Devices System Wiring Diagram Figure 3.4: D9412GV4 System Wiring Diagram, SDI and Zonex Devices Callout ᅳ Description Callout ᅳ Description 1 ᅳ.
i Notice! Terminals 24 through 36 are power limited, supervised. Fire and Intrusion devices must be on separate circuits. Refer to ICP-SDI-9114 Installation Instructions (P/N: F01U030068) D7412GV4 SDI and Zonex Devices System Wiring Diagram Figure 3.
i Notice! Terminals 24 through 36 are power limited, supervised. Fire and Intrusion devices must be on separate circuits. Refer to ICP-SDI-9114 Installation In- structions (P/N: F01U030068).
Module D9412GV4 D7412GV4 4 BB810/B820 SDI2 Inovonics Interface Modules 1 1 B920 Two-line Alphanumeric Keypad 5 16 16 B930 ATM Style Alphanumeric Keypad (SDI2) 5 16 16 B520 Auxiliary Power Supply Module 8 8 1 For the D7412GV4, only 5 inputs are available on the Octo-input at address 7.
SDI2 Bus Wiring Recommendations Use the following SDI2 bus wiring recommendations for SDI2 installation. The SDI2 bus is used by the GV4 Control Panel and corresponding modules to communicate with one another. Modules can be connected via home run, daisy chain, or single level T-tapped anywhere on the SDI2 bus.
Cable capacitance Overall cable length Cable capacitance Overall cable length Cable capacitance Overall cable length Cable capacitance Overall cable length pF/ft ft pF/ft ft pF/ft ft pFf/ft ft < 17.
Power Supply and Power Outputs Power Supply - Primary Primary (AC) Power Circuit The primary source is a 16.5 VAC, 40 VA, internally-fused transformer (Bosch Security Systems, Inc. Model D1640). The control panel draws 225 mA when idle and 300 mA when in an alarm state.
D8004 Transformer Enclosure Required for Fire Systems Use the D8004 Transformer Enclosure for the D1640 Transformer in fire and combined fire and burglary applications. i Notice! Check with the Authority Having Jurisdiction (AHJ) about mounting transformers on specific circuits.
! Warning! High current arcs are possible. The positive (red) battery lead and Terminal 5 can create high current arcs if shorted to other terminals or the enclosure. Use caution when working with the positive lead and Terminal 5. Always disconnect the positive (red) lead from the battery before removing it from Terminal 5.
Figure 4.2: Non-PowerLimited Wiring Callout ᅳ Description 1 ᅳ Conduit required for use with external batteries. 2 ᅳ Battery wires 3 ᅳ 0.25 in (6.
– Terminal 8: Output C (Switched Auxiliary Power) PTC CB5 protects Terminal 24: Zonex Power. PTC CB1 protects Terminal 32: SDI Power +. PTC CB3 protects Terminal 36: SDI2 Power +. Required by UL: – All devices powered from a power output are to be supervised.
F01U265459) contains complete instructions for programming outputs. Refer to Terminals 6 and 7, page 25 , Fire System Power Formula, page 25 , and Terminal 8, page 26 for descriptions of the functions of each terminal. Refer to the Bell Parameters section of the program to set the Fire Bell, Alarm Bell, and Gas Bell output responses for outputs.
Terminal 8 Terminal 8 provides continuous positive (+) 12.0 VDC Nominal power. Output C interrupts the power at Terminal 8 when activated. Use Terminal 8 to power smoke detectors or other devices that are reset by interrupting power. One self-resetting circuit breaker protects Terminals 6, 7, and 8 against shorts.
Specifications Voltage Input (Power Supply) 1 Primary: Terminals 1 and 2 16.5 VAC 40 VA class 2 plug-in transformer (D1640) Secondary: Terminals 4 and 5 Sealed lead-acid rechargeable battery (12.0 VDC, 7 Ah or 12.0 VDC, 17.2 or 18 Ah). The control panel supports up to two 12.
SDI Bus B-: 9 VDC 15000 (4572 m) maximum SDI2 Bus SDI2 Bus A+; 12 VDC nominal 7500 ft (2286 m) maximum 3 SDI2 Bus B-: 12 VDC nominal (7500 ft) (2286 m) maximum 3 Telephone Connections Connection: RJ31X or RJ38X jack can connect the control panels. Two telco lines: Bosch Security Systems, Inc.
B520 Specifications Voltage Input (Power Supply) Primary: 18 VAC terminal 18.0 VAC, 50 VA class 2 plug-in transformer -TR1850 (18.0 VAC, 50 VA class 2 plug-in transformer – TR1850-CA for Canada) Sec.
Recharge Cycle AC ON – Load shed relay resets, battery charging begins, Battery Trouble and AC Restoral Reports sent. 12.6 VDC – Battery Restoral Report sent, Low Battery LED off.
Terminal No Terminal Description Requirements 16 POINT 4 Terminal accommodates 14 to 22 AWG, use appropriate wire size based on loop resistance less than 100 Ω. 17 POINT 5 Terminal accommodates 14 to 22 AWG, use appropriate wire size based on loop resistance less than 100 Ω.
Terminal No Terminal Description Requirements 36 SDI2 POWER Terminal accommodates 14 to 22 AWG, use appropriate wire size based on peripheral device current.
Model Title UL 864 UL 985 Intrusion cUL Intrusion D1218 12 V, 17.2 Ah Rechargeable Battery D1255/D1255B Keypads (General Purpose) X X X D1255W Text Keypad (white) X X X D1260/ D1260B 2 Keypads X X X D1640 16.
Model Title UL 864 UL 985 Intrusion cUL Intrusion 3 RFRP-A RADION repeater X X 3 RFPR-12-A RADION PIR X 3 RFPR-C12_A RADION PIR C X 3 RFUN RADION universal transmitter X 1 Where the fire alarm transmitter is sharing on-premise communications equipment, the shared equipment must be UL Listed (ITE or fire potective signaling).
.
Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 USA www.boschsecurity.com © Bosch Security Systems, Inc., 2012.
Ein wichtiger Punkt beim Kauf des Geräts Bosch Appliances D9412GV4 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bosch Appliances D9412GV4 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bosch Appliances D9412GV4 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bosch Appliances D9412GV4 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bosch Appliances D9412GV4 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bosch Appliances D9412GV4 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bosch Appliances D9412GV4 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bosch Appliances D9412GV4. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bosch Appliances D9412GV4 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.