SPECIFICATIONS
EC Declaration of Conformity
The tool is intended for pressing pin nails into construc- tion materials such as timbers.
For European countries only
The EC declaration of conformity is included as Annex A to this instruction manual.
The typical A-weighted noise level determined accord- ing to EN60745: Sound pressure level (LpA) : 76 dB(A) Uncertainty (K) : 3 dB(A)
The noise level under working may exceed 80 dB (A).
The vibration total value determined according to EN60745: Vibration emission (ah) : 2.5 m/s
Save all warnings and instruc- tions for future reference. The term "power tool" in the warnings refers to your mains-oper- ated (corded) power tool or battery-operated (cordless) power tool.
1. Always assume that the tool contains fasten- ers. Careless handling of the nailer can result in unexpected firing of fasteners and personal injury. 2. Do not point the tool towards yourself or any- one nearby. Unexpected triggering will discharge the fastener causing an injury. 3. Do not actuate the tool unless the tool is placed firmly against the workpiece. If the tool is not in contact with the work- piece, the fastener may be deflected away from your target. 4. Disconnect the tool from the power source when the fastener jams in the tool. While removing a jammed fastener, the nailer may be accidentally activated if it is plugged in. 5. Use caution while removing a jammed fas- tener. The mechanism may be under compression and the fastener may be forcefully discharged while attempting to free a jammed condition.

1. Before using battery cartridge, read all instruc- tions and cautionary markings on (1) battery charger, (2) battery, and (3) product using battery. 2. Do not disassemble battery cartridge. 3. If operating time has become excessively shorter, stop operating immediately. It may result in a risk of overheating, possible burns and even an explosion. 4. If electrolyte gets into your eyes, rinse them out with clear water and seek medical attention right away. It may result in loss of your eyesight. 5. Do not short the battery cartridge: (1) Do not touch the terminals with any con- ductive material. (2) Avoid storing battery cartridge in a container with other metal objects such as nails, coins, etc. (3) Do not expose battery cartridge to water or rain. A battery short can cause a large current flow, over- heating, possible burns and even a breakdown. 6. Do not store the tool and battery cartridge in locations where the temperature may reach or exceed 50 °C (122 °F). 7. Do not incinerate the battery cartridge even if it is severely damaged or is completely worn out. The battery cartridge can explode in a fire. 8. Be careful not to drop or strike battery. 9. Do not use a damaged battery. 10. The contained lithium-ion batteries are subject to the Dangerous Goods Legislation requirements. For commercial transports e.g. by third parties, forwarding agents, special requirement on pack- aging and labeling must be observed. For preparation of the item being shipped, consult- ing an expert for hazardous material is required. Please also observe possibly more detailed national regulations. Tape or mask off open contacts and pack up the battery in such a manner that it cannot move around in the packaging. 11. Follow your local regulations relating to dis- posal of battery. SAVE THESE INSTRUCTIONS.
Tips for maintaining maximum battery life 1. Charge the battery cartridge before completely dis- charged. Always stop tool operation and charge the battery cartridge when you notice less tool power. 2. Never recharge a fully charged battery cartridge. Overcharging shortens the battery service life. 3. Charge the battery cartridge with room tempera- ture at 10 °C - 40 °C (50 °F - 104 °F). Let a hot battery cartridge cool down before charging it.


Only for battery cartridges with the indicator ► Fig.2: 1. Indicator lamps 2. Check button
Press the check button on the battery cartridge to indi- cate the remaining battery capacity. The indicator lamps light up for few seconds.

To remove the battery cartridge, slide it from the tool while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the battery cartridge with the groove in the housing and slip it into place. Insert it all the way until it locks in place with a little click. If you can see the red indicator on the upper side of the button, it is not locked completely.

To prevent the switch trigger from accidentally pulled, the trigger-lock button is provided. To pull the switch trigger, depress the trigger-lock button from A side. After use, always press in the trigger-lock button from B side.
The tool is equipped with a battery protection system. This system automatically cuts off power to the motor to extend battery life. The tool will automatically stop during operation if the tool and/or battery are placed under one of the following conditions:

Overloaded: The tool is operated in a manner that causes it to draw an abnormally high current. In this situation, turn the tool off and stop the application that caused the tool to become overloaded. Then turn the tool on to restart. If the tool does not start, the battery is overheated. In this situation, let the battery cool before turning the tool on again.
Depth of pin-nailing can be adjusted on this pin nailer. To adjust the depth of nailing, turn the adjuster. The depth of nailing is the deepest when the adjuster is turned fully in the A direction shown in the figure. It will become shallower as the adjuster is turned in the B direction. Depth can be adjusted 1.5 mm to the maximum. ► Fig.5: 1. Adjuster
Low battery voltage: The remaining battery capacity is too low and the tool will not operate. If you turn the tool on, the motor does not run or the motor runs again but stops soon. In this situation, remove and recharge the battery.

Nose adapter
Pull the switch trigger or actuate the contact element to light up the lamp. The lamp keeps on lighting while pull- ing the switch trigger or actuating the contact element. The lamp goes out approximately 10 seconds after releasing the switch trigger and the contact element. ► Fig.7: 1. Lamp
When firing pin nails on the material with easily-marred sur- faces, use the nose adapter. To install the nose adapter, place it over the driver guide cover so that the protrusion inside the nose adapter fits to the dent in the driver guide cover. You can store the nose adapter on the holder on the back end of the magazine to keep it from being lost. ► Fig.9: 1. Dent 2. Protrusion 3. Nose adapter
The hook is convenient for temporarily hanging the tool. This can be installed on either side of the tool. To install the hook, insert it into a groove in the tool housing on either side and then secure it with a screw. To remove, loosen the screw and then take it out. ► Fig.11: 1. Groove 2. Hook 3. Screw
When not in use, store the hex wrench as shown in the figure to keep it from being lost. ► Fig.12: 1. Hex wrench
Test safety systems for possible fault before operation as follows.
To remove pin nails, follow the installation procedures in reverse.
If the tool operates in the case of 3 and 4 above, the safety systems are faulty. Stop using the tool immedi- ately and ask your local service center.

Removing jammed pin nails
Take out pin nails that remain inside the magazine. Remove three screws with the hex wrench that are securing the driver guide cover. Take the jammed nails from the nail guide groove that has appeared. When it is difficult to take out the jammed nails, further remove two screws with the hex wrench that are secur- ing the contact top cover. Then take them out. ► Fig.18: 1. Driver guide cover 2. Screw 3. Contact
You can also drive the pin nails when dragging the tool to the next area with the contact element pressed against the material and pulling the switch trigger. ► Fig.15
If the head of the pin nail remains above the workpiece surface, drive the pin nail while holding the pin nailer head firmly against the workpiece. ► Fig.16
To maintain product SAFETY and RELIABILITY, repairs, any other maintenance or adjustment should be performed by Makita Authorized or Factory Service Centers, always using Makita replacement parts.
When the number of remaining pin nails in the maga- zine are 0 - 3 pieces, the switch trigger can no longer be pulled. At this time, insert a new strip of pin nails in the magazine and the switch trigger can be pulled again.
You can check the amount of remaining pin nails through the sight window. The red indicator moves toward fastening opening with the amount of remaining pin nails become smaller. ► Fig.17: 1. Sight window 2. Indicator
top cover
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.