DE
Makita logo
Offizielle Bedienungsanleitung

Makita MT401

32 Seiten·952 KB·Sonstiges·PDF·ENJA
Makita MT401
Inhaltsverzeichnis 11 Abschnitte ENGLISH (Original instructions) · Explanation of general view · SPECIFICATIONS · FUNCTIONAL DESCRIPTION · … AnzeigenAusblenden
Page 1 of the Makita MT401 user manual
Seite 1 · Zum Vergrößern klicken
Seite 1
Makita MT401 diagram (page 1)
Abb. 1
Makita MT401 diagram (page 1)
Abb. 2
Page 2 of the Makita MT401 user manual — 7 013224
Seite 2 · Zum Vergrößern klicken
Seite 2
Makita MT401 diagram (page 2)
Abb. 3

1 013219 2 013220

Makita MT401 — 1 013219 2 013220 diagram (page 2)
Abb. 4

3 013221 4 006296

Makita MT401 — 3 013221 4 006296 diagram (page 2)
Abb. 5

5 013222 6 013223

Makita MT401 — 5 013222 6 013223 diagram (page 2)
Abb. 6

7 013224

Page 3 of the Makita MT401 user manual — GEB073-1
Seite 3 · Zum Vergrößern klicken
Seite 3

ENGLISH (Original instructions)

Explanation of general view

1. Switch trigger 2. Lock button 3. Air volume adjusting dial
4. Nozzle 5. Pin 6. Blower outlet
7. Notch 8. Sash nozzle

SPECIFICATIONS

ModelMT401 CapacitiesMax. air volume1.2 - 2.9 m3/min. No load speed (min-1)8,500 - 16,000 Overall length427 mm Net weight Safety class1.5 kg /II
  • Due to our continuing program of research and development, the specifications herein are subject to change without notice.
  • Specifications may differ from country to country.
  • Weight according to EPTA-Procedure 01/2003

Intended use ENE018-1 The tool is intended for blowing dust.

SAVE THESE INSTRUCTIONS.

Power supply ENF002-2 The tool should be connected only to a power supply of the same voltage as indicated on the nameplate, and can only be operated on single-phase AC supply. They are double-insulated and can, therefore, also be used from sockets without earth wire.

FUNCTIONAL DESCRIPTION

General Power Tool Safety Warnings GEA010-1

Switch action

CAUTION: • Before plugging in the tool, always check to see that the switch trigger actuates properly and returns to the “OFF” position when released. (Fig. 1) To start the tool, simply pull the switch trigger. Release the switch trigger to stop. For continuous operation, pull the switch trigger and then push in the lock button, and then release the switch trigger. To stop the tool from the locked position, pull the switch trigger fully, then release it.

Save all warnings and instructions for future reference.

BLOWER SAFETY WARNINGS

GEB073-1

1. Always use protective goggles, a cap and mask when using the blower. 2. Never point the nozzle at anyone in the vicinity when using the blower. 3. Warning - Electric shock could occur if used on wet surfaces. Do not expose to rain. Store indoors. 4. Never block suction inlet and/or blower outlet. Increased motor revolution may cause dangerous fan breakage. 5. The blower is not intended for use by young children or infirm persons without supervision. 6. Young children should be supervised to ensure that they do not play with the blower.

Air volume adjusting dial (Fig. 2) Air speed and volume can be adjusted without positive stops by turning the air volume adjusting dial. To obtain high speed and increase volume, turn the air volume adjusting dial to the A direction shown in the figure (for the bigger number). Turn the air volume adjusting dial to the B direction (for the smaller number) to obtain low speed and to decrease the air volume.

Page 4 of the Makita MT401 user manual — MAINTENANCE
Seite 4 · Zum Vergrößern klicken
Seite 4

ASSEMBLY

  • WARNING:
  • The vibration emission during actual use of the power tool can differ from the declared emission value depending on the ways in which the tool is used.
  • Be sure to identify safety measures to protect the operator that are based on an estimation of exposure in the actual conditions of use (taking account of all parts of the operating cycle such as the times when the tool is switched off and when it is running idle in addition to the trigger time).

Installing or removing the nozzle (Fig. 3) Align the pin protruding inside the nozzle with the notch on the tool, push the nozzle to the blower outlet and then securely turn the nozzle clockwise. To remove the nozzle, turn counterclockwise and pull it out.

For European countries only ENH101-16 EC Declaration of Conformity We Makita Corporation as the responsible manufacturer declare that the following Makita machine(s): Designation of Machine: Blower Model No./Type: MT401 are of series production and Conforms to the following European Directives:

Installing the sash nozzle (Fig. 4) Sash nozzle is convenient for operation in a sash rail, corner or tight place between cabinets. Secure the sash nozzle by inserting it into the nozzle from the back of the nozzle. Install the nozzle with the attached sash nozzle. (Fig. 5)

Sash nozzle storage (Fig. 6) When not in use, the sash nozzle can be conveniently stored at the bottom of the tool as shown in the figure.

2006/42/EC And are manufactured in accordance with the following standards or standardised documents:

EN60745 The technical documentation is kept by:

OPERATION

Makita International Europe Ltd. Technical Department, Michigan Drive, Tongwell, Milton Keynes, Bucks MK15 8JD, England

Blowing (Fig. 7) Point the tool to the object to be blown off and turn on the tool.

24. 4. 2012

MAINTENANCE

  • CAUTION:
  • Always be sure that the tool is switched off and unplugged before attempting to perform inspection or maintenance.
  • Never use gasoline, benzine, thinner, alcohol or the like. Discoloration, deformation or cracks may result. To maintain product SAFETY and RELIABILITY, repairs, carbon brush inspection and replacement, any other maintenance or adjustment should be performed by Makita Authorized Service Centers, always using Makita replacement parts.

Director Makita Corporation 3-11-8, Sumiyoshi-cho, Anjo, Aichi, 446-8502, JAPAN

Noise ENG905-1 The typical A-weighted noise level determined according to EN60745:

Sound pressure level (LpA): 90 dB (A) Sound power level (LWA): 101 dB (A) Uncertainty (K): 3 dB (A)

Wear ear protection.

Vibration ENG900-1 The vibration total value (tri-axial vector sum) determined according to EN60745:

Work mode: operation without load Vibration emission (ah): 2.5 m/s2 or less Uncertainty (K): 1.5 m/s2

  • ENG901-1
  • The declared vibration emission value has been measured in accordance with the standard test method and may be used for comparing one tool with another.
  • The declared vibration emission value may also be used in a preliminary assessment of exposure.

Tomoyasu Kato

Frage zu Makita MT401 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Makita MT401

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Makita MT401 PDF-Anleitung

32 Seiten·952 KB·Sonstiges·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…