1 Switch trigger 2 Lock button 3 Lamp 4 Reversing switch lever 5 Quick change chuck for SDS- plus 6 Change cover line 7 Change cover 8 Spindle 9 Quick change drill chuck 10 Rotation with hammering 11 Action mode changing knob 12 Rotation only 13 Hammering only
14 Hook 15 Protrusions 16 Grooves 17 Bit shank 18 Bit grease 19 Bit 20 Chuck cover 21 Grip base 22 Depth gauge 23 Toothed side of hex hole marking on the grip base 24 Toothed side of the depth gauge 25 Dust cup 26 symbol
27 Attachment at the foot of dust cup 28 Bellows 29 Attachment 30 Inside periphery 31 Flat side 32 Cap 33 Groove 34 Blow-out bulb 35 Drill chuck assembly (optional accessory) 36 Chuck key 37 Sleeve 38 Ring
GEA010-1 General Power Tool Safety Warnings
ENE042-1 Intended use The tool is intended for hammer drilling and drilling in brick, concrete and stone. It is also suitable for drilling without impact in wood, metal, ceramic and plastic.
Save all warnings and instructions for future reference.
ROTARY HAMMER SAFETY WARNINGS 1. Wear ear protectors. Exposure to noise can cause hearing loss. 2. Use auxiliary handle(s), if supplied with the tool. Loss of control can cause personal injury. 3. Hold power tool by insulated gripping surfaces, when performing an operation where the cutting accessory may contact hidden wiring or its own cord. Cutting accessory contacting a “live” wire may make exposed metal parts of the power tool “live” and could give the operator an electric shock.
ENF002-2 Power supply The tool should be connected only to a power supply of the same voltage as indicated on the nameplate, and can only be operated on single-phase AC supply. They are double-insulated and can, therefore, also be used from sockets without earth wire.

4. Wear a hard hat (safety helmet), safety glasses and/or face shield. Ordinary eye or sun glasses are NOT safety glasses. It is also highly recommended that you wear a dust mask and thickly padded gloves. 5. Be sure the bit is secured in place before operation. 6. Under normal operation, the tool is designed to produce vibration. The screws can come loose easily, causing a breakdown or accident. Check tightness of screws carefully before operation. 7. In cold weather or when the tool has not been used for a long time, let the tool warm up for a while by operating it under no load. This will loosen up the lubrication. Without proper warm- up, hammering operation is difficult. 8. Always be sure you have a firm footing. Be sure no one is below when using the tool in high locations. 9. Hold the tool firmly with both hands. 10. Keep hands away from moving parts. 11. Do not leave the tool running. Operate the tool only when hand-held. 12. Do not point the tool at any one in the area when operating. The bit could fly out and injure someone seriously. 13. Do not touch the bit or parts close to the bit immediately after operation; they may be extremely hot and could burn your skin. 14. Some material contains chemicals which may be toxic. Take caution to prevent dust inhalation and skin contact. Follow material supplier safety data.
For Model HR2631F, HR2631FT
For Model HR2631F, HR2631FT, HR2320T, HR2630, HR2630T
This tool has a reversing switch to change the direction of rotation. Move the reversing switch lever to the
position (A side) for clockwise rotation or to the position (B side) for counterclockwise rotation.
For Model HR2641 NOTE: • When you operate the tool in counterclockwise rotation, the switch trigger is pulled only halfway and the tool runs at half speed. For counterclockwise rotation, you cannot push in the lock button.
SAVE THESE INSTRUCTIONS.
This tool has a reversing switch to change the direction of rotation. Move the reversing switch lever to the
position (A side) for clockwise rotation or the position (B side) for counterclockwise rotation.
For Model HR2631FT, HR2320T, HR2630T The quick change chuck for SDS-plus can be easily exchanged for the quick change drill chuck.
Removing the quick change chuck for SDS-plus (Fig. 6)
To start the tool, simply pull the switch trigger. Tool speed is increased by increasing pressure on the switch trigger. Release the switch trigger to stop. For continuous operation, pull the switch trigger, push in the lock button and then release the switch trigger. To stop the tool from the locked position, pull the switch trigger fully, then release it.
Grasp the change cover of the quick change chuck for SDS-plus and turn in the direction of the arrow until the change cover line moves from the symbol to the symbol. Pull forcefully in the direction of the arrow.
Attaching the quick change drill chuck (Fig. 7) Check the line of the quick change drill chuck shows the
symbol. Grasp the change cover of the quick change drill chuck and set the line to the symbol. Place the quick change drill chuck on the spindle of the tool.

Grasp the change cover of the quick change drill chuck and turn the change cover line to the symbol until a click can clearly be heard.
Bit grease Coat the bit shank head beforehand with a small amount of bit grease (about 0.5 – 1 g). This chuck lubrication assures smooth action and longer service life.
Installing or removing the bit Clean the bit shank and apply bit grease before installing the bit. (Fig. 13) Insert the bit into the tool. Turn the bit and push it in until it engages. (Fig. 14) After installing, always make sure that the bit is securely held in place by trying to pull it out. To remove the bit, pull the chuck cover down all the way and pull the bit out. (Fig. 15)
Rotation with hammering (Fig. 8) For drilling in concrete, masonry, etc., rotate the action mode changing knob to the symbol. Use a tungsten- carbide tipped bit.
Bit angle (when chipping, scaling or demolishing) The bit can be secured at the desired angle. To change the bit angle, rotate the action mode changing knob to the O symbol. Turn the bit to the desired angle. (Fig. 16) Rotate the action mode changing knob to the g symbol. (Fig. 17) Then make sure that the bit is securely held in place by turning it slightly.
Rotation only (Fig. 9) For drilling in wood, metal or plastic materials, rotate the action mode changing knob to the m symbol. Use a twist drill bit or wood bit.
Hammering only (Fig. 10) For chipping, scaling or demolition operations, rotate the action mode changing knob to the g symbol. Use a bull point, cold chisel, scaling chisel, etc.
Depth gauge The depth gauge is convenient for drilling holes of uniform depth. (Fig. 18) Press the lock button on the grip base in the direction of arrow shown in the figure and with the lock button being pressed insert the depth gauge into the hex. hole in the grip base. (Fig. 19) At this time, the depth gauge needs to be inserted so that its toothed side is directed to the toothed side of hex hole marking on the grip base as shown in the figure. (Fig. 20) Adjust the depth gauge to the desired depth by moving it back and forth while pressing the lock button. After the adjustment, release the lock button to lock the depth gauge. (Fig. 21) NOTE: • Inserting the depth gauge with its toothed side not directed to the toothed side of hex hole marking on the grip base as shown in the figure does not allow the depth gauge to be locked.
The torque limiter will actuate when a certain torque level is reached. The motor will disengage from the output shaft. When this happens, the bit will stop turning.
Dust cup (optional accessory) (Fig. 22) Use the dust cup to prevent dust from falling over the tool and on yourself when performing overhead drilling operations. Attach the dust cup to the bit as shown in the figure. The size of bits which the dust cup can be attached to is as follows.
The hook is convenient for hanging the tool temporarily. To use the hook, simply lift up hook until it snaps into the open position. When not in use, always lower hook until it snaps into the closed position.
There is another type of dust cup (optional accessory) which helps you prevent dust from falling over the tool and on yourself when performing overhead drilling operations.
Install the side grip so that the protrusions on the grip fit in between the grooves on the tool barrel. Then tighten the grip by turning clockwise at the desired position. It may be swung 360° so as to be secured at any position.
For Model HR2641

Chipping/Scaling/Demolition (Fig. 32) Set the action mode changing knob to the g symbol. Hold the tool firmly with both hands. Turn the tool on and apply slight pressure on the tool so that the tool will not bounce around, uncontrolled. Pressing very hard on the tool will not increase the efficiency.
Set the action mode changing knob to the m symbol. You can drill up to 13 mm diameter in metal and up to 32 mm diameter in wood.
For Model HR2631F, HR2641, HR2630 Use the drill chuck assembly (optional accessory). When installing it, refer to “Installing or removing the bit” described on the previous page. (Fig. 33) To install the bit, place it in the chuck as far as it will go. Tighten the chuck by hand. Place the chuck key in each of the three holes and tighten clockwise. Be sure to tighten all three chuck holes evenly. To remove the bit, turn the chuck key counterclockwise in just one hole, then loosen the chuck by hand. (Fig. 34)
CAUTION: • There is tremendous and sudden twisting force exerted on the tool/bit at the time of hole break-through, when the hole becomes clogged with chips and particles, or when striking reinforcing rods embedded in the concrete. Always use the side grip (auxiliary handle) and firmly hold the tool by both side grip and switch handle during operations. Failure to do so may result in the loss of control of the tool and potentially severe injury.
For Model HR2631FT, HR2320T, HR2630T Use the quick change drill chuck as standard equipment. When installing it, refer to “changing the quick change chuck for SDS-plus” described on the previous page. (Fig. 35 & 36) Hold the ring and turn the sleeve counterclockwise to open the chuck jaws. Place the bit in the chuck as far as it will go. Hold the ring firmly and turn the sleeve clockwise to tighten the chuck. To remove the bit, hold the ring and turn the sleeve counterclockwise. (Fig. 37)
Set the action mode changing knob to the symbol. Position the bit at the desired location for the hole, then pull the switch trigger. Do not force the tool. Light pressure gives best results. Keep the tool in position and prevent it from slipping away from the hole. Do not apply more pressure when the hole becomes clogged with chips or particles. Instead, run the tool at an idle, then remove the bit partially from the hole. By repeating this several times, the hole will be cleaned out and normal drilling may be resumed. NOTE: • Eccentricity in the bit rotation may occur while operating the tool with no load. The tool automatically centers itself during operation. This does not affect the drilling precision.
Blow-out bulb (optional accessory) (Fig. 31) After drilling the hole, use the blow-out bulb to clean the dust out of the hole.
When performing diamond core drilling operations, always set the change lever to the m position to use “rotation only” action.

ENG905-1 Noise The typical A-weighted noise level determined according to EN60745:
Model HR2631F, HR2631FT, HR2641 Sound pressure level (LpA): 90 dB (A) Sound power level (LWA): 101 dB (A) Uncertainty (K): 3 dB (A)
Model HR2320T, HR2630, HR2630T Sound pressure level (LpA): 91 dB (A) Sound power level (LWA): 102 dB (A) Uncertainty (K): 3 dB (A)
ENG900-1 Vibration The vibration total value (tri-axial vector sum) determined according to EN60745:
To maintain product SAFETY and RELIABILITY, repairs, carbon brush inspection and replacement, any other maintenance or adjustment should be performed by Makita Authorized Service Centers, always using Makita replacement parts.
Work mode: drilling into metal Vibration emission (ah, D): 2.5 m/s2 or less Uncertainty (K): 1.5 m/s2
If you need any assistance for more details regarding these accessories, ask your local Makita Service Center.
Work mode: drilling into metal Vibration emission (ah, D): 2.5 m/s2 or less Uncertainty (K): 1.5 m/s2
Work mode: drilling into metal Vibration emission (ah, D): 2.5 m/s2 or less Uncertainty (K): 1.5 m/s2
Wear ear protection

Work mode: drilling into metal Vibration emission (ah, D): 2.5 m/s2 or less Uncertainty (K): 1.5 m/s2
ENH101-18 For European countries only
Makita declares that the following Machine(s): Designation of Machine: Combination Hammer Model No./ Type: HR2631F, HR2631FT, HR2641, HR2320T, HR2630, HR2630T Conforms to the following European Directives:
2006/42/EC They are manufactured in accordance with the following standard or standardized documents:
EN60745 The technical file in accordance with 2006/42/EC is available from:
Makita, Jan-Baptist Vinkstraat 2, 3070, Belgium
19.5.2014
Director Makita, Jan-Baptist Vinkstraat 2, 3070, Belgium
Yasushi Fukaya
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.