Benutzeranleitung / Produktwartung 2400E LP des Produzenten Bosch Appliances
Zur Seite of 36
MO DE L 24 0 0E NG and 24 0 0E LP - I N D OO R M OD E L T emperat ure Modulated wit h Elec tronic Ignit ion Suit able for heating pot able wat er only Not approved for spac e heating purpose s (Intended for variable flow applications) 2400 E NG - Natural Gas 2400 E LP - Liquefied Petroleum (LP) Gas 6 720 608 263 US (06.
6 720 608 263 2 Index Index 1W a r n i n g 2 2 Appliance details 4 2.1 Features 4 2.2 2400 E Specific ations (Technical data) 4 2.3 Dimensions and Minimum installa tion clearances 6 2.4 General rules to follow for safe o peration 7 2.5 Proper location for in stalling your heater 7 2.
6 720 608 263 Warning 3 What to do if you smell gas • Close gas valve. Open wi ndows. • Do not try to light any appliance. • Do not touch any electri cal switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
6 720 608 263 4 Appliance details 2 Appliance details 2.1 Features Parts • Touch Pa d interface co ntrol • High power pre-mix compact burner with low Nox emissions • Modulating Gas Valve with constant gas:air ratio control • Modulating water valve for improved comfort and temperature control.
6 720 608 263 Appliance details 5 Combustion •N O x ≤ 55 ppm •C O ≤ 250 ppm •C O 2 level set from factory, see chapter 9. Dimensions • Depth (in): 8 ½” (220 mm ) • Width (in): 15 ¾” (400 mm) • Height (in): 23 ½” (600 mm) • Weight: 47 pounds (21 kg).
6 720 608 263 6 Appliance details 2.3 Dimensions and Minimum installation clearances Fig. 4 Dimensions 1 Cover 2 On/Off switch 3 Reset button 4 LCD display 5 Program button 6 Temperature buttons Fig.
6 720 608 263 Appliance details 7 2.4 General rules to follow for safe operation B 1. You should follow these instruct ions when you install your heater. In the United States: The installation must conform with local codes or, in t he absence of local c odes, the National Fuel Gas Code ANSI Z223.
6 720 608 263 8 Appliance details 2.6 Clearances The 2400 E is design certified for installation on a combustible wall (see 2.7 Mounting installation) provided the floor covering below the heater is noncombustible. For instal lations in an alc ove or closet, maintain the minimum clearanc es to combustible and non-combustible materials listed below.
6 720 608 263 Appliance details 9 construction, infiltration air i s normally adequate to provide air for combustion. • Appliances located in confined spaces: The confined space must be provided with two permanent openings, one commencing within 12 inches (304.
6 720 608 263 10 Appliance details The appliance should be loca ted as close to the point of termination as possible. The maximum vent le ngth is 26 feet (8 m) with one 90 degree elbow.
6 720 608 263 Appliance details 11 Note: reduce 2½ ft for each 90° elbow us ed after the first one, reduce 1 ¼ ft for each 45° elbow. Vent Safety System The 2400 E will shut down if inadequate exhaust venting is detected or a lack of combust ion air is provided to the unit; see troubleshooting sec tion on page 24.
6 720 608 263 12 Appliance details 2.9.1 Venting options Installing this water heater as a room sealed (TWIN PIPE SYSTEM) is the recommended method. Contact BBTNA or dealer for available vent termination k its and vent materials for th is water heater.
6 720 608 263 Appliance details 13 Recommended exhaust vent terminator position Fig. 16 * Subject to local codes and anticipated snow level ** Other equipment that operates with a mechanical air inlet may require greate r distan ces, reference manufacturer's in structio ns Ref.
6 720 608 263 14 Appliance details Supporting the exhaust vent system Fig. 17 Horizontal side wall venting inst allation (combustion air piping not being shown) Fig.
6 720 608 263 Appliance details 15 Fig. 20 Vertical venting installation - Masonr y Chimney (combustion air piping not being shown) A condensate drain tube must be attached to the exhaust collar of the heater for all ven t type applications, see page 11.
6 720 608 263 16 Appliance details FOR NA TU RAL GAS Maximum Capacity of pipe in Cubic Feet of Gas per Hour for Gas Pressure of 0.5 Psig or less and a Pre ssure drop of 0.3 in Water Column (0.75mbar).(Based on a 0.60 Sp ecific Gravity Gas) Btu num bers given in thousands.
6 720 608 263 Appliance details 17 2.11 Gas line sizing B It is strongly recomme nded that the Natu ral Gas pipe be Black Iron pipe the entire di stance from the outside meter to the inlet of the gas connection. ¾” Black Iron pipe up to 20 feet (6.
6 720 608 263 18 Appliance details HIGH ALTITUDE OPERATION 2.13 Water connections When facing the heater, the ¾” cold water inlet is on the bottom right and the hot water outlet is on the bottom left. Install the heater cen trally in the building if possible and make hot water piping runs as short as possible .
6 720 608 263 Appliance details 19 2.14 Electrical connections The 2400 E requires an electri cal power supply from a 120VAC 60Hz circuit and must be properly grounded. A means for switching of f the 120VAC power supply must be provided. The heater is wi red as shown in the wiring diagram (chapter 6, Fig.
6 720 608 263 20 Appliance details When the heater is in operation you will hear its power vent fan and burner operating. Upon turning off the hot water flow the power vent fan will continue to operate for up to 60 seconds to exhaust all fl ue gases.
6 720 608 263 Operation instructions 21 3 Operation instructions Fig. 27 1 On/Off switch 2 Reset button 3 Program Key 4 Increasing temperature s elector 5 Decreasing temperature sele ctor 6 LCD display 3.1 Power On B T o start the appliance switc h the button to position ( I ).
6 720 608 263 22 Operation instructions Setting the water temperature The desired temperature of the hot water can be adjusted on the front control panel of the heater.
6 720 608 263 Operation instructions 23 3.3 Use of remote control accessory Fig. 31 Remote control The wireless remote control accessory and the temperature selector butt ons on the front of the water heater operate identicall y. Contact your distributor or BBTNA to order if the remote control accessory is preferred.
6 720 608 263 24 Maintenance and service 4 Maintenance and service The unit should be checked once a year by a gas technician. If repairs are neede d, the repairs should be done by a gas technician To remove front cover B Remove plastic decals on front panel (Page 5, Fig.
6 720 608 263 Troubleshooting 25 Test by following 4t h bullet under BURNERS DO NOT IGNITE WHEN HOT WATER IS TURNED ON. LOW WATER FLOW/PRESSURE • Too many hot water applications are bein g used simultaneously or too much flow is being demanded The 2400 E will effectively support two 2.
6 720 608 263 26 Troubleshooting Display Cause Solution E9 Temperature limiter opened circuit (overheat). Trips at 220F (104C). Check connections.* Check heat exchanger condition.* EA No ionization during safety time (safety time out). Note: appliance makes 3 igniti on attempts before entering error mode “EA”.
6 720 608 263 Electric al diagra m 27 6 Electrical diagram Fig. 37 Electrical scheme 1 Intlet water temperature sensor 2 Ionization sensor 3 Water flow sensor 4 Over heat protection 5 Temperature li m.
6 720 608 263 28 2400 E Functional scheme 7 2400 E Functional scheme Fig. 38 Functional scheme.
6 720 608 263 Interior components diagram and parts list 29 8 Interior components diagram and parts list 8.1 Interior components Fig. 39 Components 1 Cover 2 On/Off switch 3 Reset button 4 LCD display.
6 720 608 263 30 Interior components diagram and par ts list 8.2 Components diagram Fig. 41 Components Diagram.
6 720 608 263 Interior components diagram and parts list 31 8.3 Parts list Item Description Reference 1 Front cover 8 7 05 42 1 9 1 5 2 Shield 8 7 05 506 706 3 Heat exc hanger 8 7 05 406 285 4 Heat ex.
6 720 608 263 32 Special ad justment for measurin g and adjusting CO2 levels 9 Special adjustment for measuring and adjusting CO 2 levels The CO 2 can only be adjusted by a certified gas technician with a calibrated CO 2 analyzer.
6 720 608 263 Special adjustment for measur ing and adjusting CO2 levels 33 D. Returning to Service: 1. Return slotted cover to original position. 2. Reinstall Torx cover. 3. Remove CO 2 analyze r probe a nd reinsta ll flat head screw in exhaust collar.
6 720 608 263 34 Protecting the environment 10 Protecting the environment Packing The packing box may be ful ly recycled as confirmed by the recycling s ymbol . Components Many parts in the heate r can be fully re cycled in the end of the product life.
6 720 608 263 Twelve Year Limited Warranty 35 11 Twelve Year Limited Warranty General Aquastar w ater heaters are warranted by the Manufacturer (BOSCH) through BBT North America.
Recycled paper © 2006 BB T NOR TH A M E RICA, W aitsfield, VT all rights reser ved Replacement Parts available from : VU L CAN O T ermodomésticos S.A . Estrada de C acia 380 1 - 8 56 Aveiro - PO RTU GAL BBT NORTH AMERICA Bosch Group Bosch Water Heating 340 Mad River Park Waitsfield, VT 05673 Phone 800-642-3111 Fax (802) 496-6924 www.
Ein wichtiger Punkt beim Kauf des Geräts Bosch Appliances 2400E LP (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bosch Appliances 2400E LP noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bosch Appliances 2400E LP - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bosch Appliances 2400E LP reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bosch Appliances 2400E LP erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bosch Appliances 2400E LP besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bosch Appliances 2400E LP verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bosch Appliances 2400E LP. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bosch Appliances 2400E LP gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.