W ARNING : Improper inst allation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier .
2 This well engineered, gas water heater has been specially designed to operate as a circulating water heater . FEA TURES - High Quality Materials for Long Working Life. - Copper heating coils for endless supply of hot water . - Safety thermocouple at pilot burner .
3 D861_059 MINIMUM INST ALLA TION CLEARANCES FROM COMBUSTIBLE AND NON COMBUSTIBLE MA TERIALS FOR ALCOVE OR CLOSET INST ALLA TIONS FRONT VIEW SIDE VIEW AQUAST AR MODEL 125BL M O DE L 125B L T O P ( A ).
4 If you are using the AquaStar for combined space heating and potable water heating (see schematic diagram below) , all piping and other components connected to the system must be suit able for pot a.
5 7 . Correct gas pressure is critical for the optimum operation of this heater (see specifications on page 2). Gas piping must be sized to provide the required pressure at the maximum output of the heater , while all the other gas appliances are in operation.
6 dilution of flue gases. Appliances located in confined spaces:) The confined space must be provided with two permanent openings, one commencing within 12 inches of the top and one commencing within 12 inches of the bottom of the enclosure.
7 Fig. 3 - Flue Adaptor for High Altitude Canadian Installations W ARNING : Failure T O INCREASE THE VENT SIZE TO SIX INCHES AND/or assure that the manifold pressure is set to proper value listed for applications at high altitudes will cause unsafe venting, asphyxiation, and will void CSA Certification.
8 THREADED ASSEMBL Y SWEA TED ASSEMBL Y 1/2” FLEX PIPE PRV TO APPROPRIA TE DISCHARGE S FITTING PIPE PRV TO APPROPRIA TE DISCHARGE 1/2” FLEX Fig. 6-Plumbing connections for the Aquastar 125BL NOTE: Do not apply soap solution to pilot filter screen or pilot orifice area.
9 Fig. 7 - Pressure Relief V alve Connecting the pressure relief valve (PRV) A listed pressure relief valve supplied with the heater must be installed at the time of installation. No valve is to be placed between the PRV and the heater . No reducing coupling or other restriction may be installed in the discharge line.
10 T o clean the pilot burner and/ or the pilot orifice : T urn of f the gas at the unit. Remove the cover of the heater . T o do so, remove incandescent particle tray and unscrew the central screw located at the bottom of the front cover . Pull main cover out toward you and lift up and out.
11 C . Gas regulator may be shut or damaged. 2. In-line AquaStar gas regulator jammed (usually on LP gas) Replace or unjam the regulator . Note: The regulator furnished with the heater is designed for low gas pressure. Excessive pressure will lock it up (propane only).
12 temperature relay for the primary circulator pump is possibly set too high. WA TER IS NOT HOT ENOUGH 1. Water flow rate is too high. Decrease the flow rate.
13 Fig. 10 - Diagram of AquaStar 125 BL 2 4 6 7 1 5 8 10 1. Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Pilot gas tubing 5. Main gas burner 6. Gas valve 7. Gas control slide 8. Piezo igniter 9. Location of pressure tap nipple 10.
14 Fig. 1 1 - INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST.
15 Fig. 1 1 INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST 125BL 1 Cover ¤ 8 705 421 031 2 Cap cover ¤ 8 703 304 01 1 3 W ater connection gasket ¤ 8 710 103 043 4 Draft divertor ¤ 8 705 505 354 5 Hea.
Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park W ait sfield, V ermont 05673 Phone 800-642-31 11 Fax (802) 496-6924 ww w .controlledenergy .com techsuppport@controlledenergy .com VULCANO T ermodomésticos S.
Ein wichtiger Punkt beim Kauf des Geräts Bosch Appliances 125B NGL (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bosch Appliances 125B NGL noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bosch Appliances 125B NGL - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bosch Appliances 125B NGL reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bosch Appliances 125B NGL erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bosch Appliances 125B NGL besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bosch Appliances 125B NGL verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bosch Appliances 125B NGL. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bosch Appliances 125B NGL gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.