40 30 20 10 0 0 10 20 30 40 5055 60














Stove · Thinner

1 Compressor air output per minute 2 Nailing frequency (times/min.) 3 Adjuster 4 Shallow 5 Deep 6 Too deep 7 Flush 8 Too shallow 9 Hook 10 Hole 11 Protrusion 12 Nose adapter 13 Lever 14 Door
15 Adjustfit 16 Change plate 17 Arrow 18 Nail guide 19 Feeder 20 Trigger 21 Contact element 22 Change lever 23 0.7 mm or less thick for steel plate 24 Thickness of workpiece 25 10 mm or more 26 C-shaped steel (Thickness 1.6 mm – 2.3 mm) 27 Nail driven to a proper depth
28 Nail driven too deep will cause deformation of workpieces 29 Nail length 30 Wood thickness 31 Concrete range 10 – 15 mm 32 Exhaust cover 33 Small rod 34 Cap 35 Drain cock 36 Air filter 37 Oiler 38 Pneumatic oil 39 Screwdriver
Intended use The tool is intended for the preliminary interior work such as fixing floor joists or common rafters and framing work in 2” x 4” housing.
ENB109-2 WARNING: WHEN USING THIS TOOL, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF PERSONAL INJURY, INCLUDING THE FOLLOWING:
Safety glasses · Face shield

involves the use of scaffoldings, stairs, ladders, or ladder alike constructions, e.g. roof laths; - closing boxes or crates; - fitting transportation safety systems e.g. on vehicles

If nail are driven too deep, turn the adjuster clockwise. If nail are driven too shallow, turn the adjuster counter- clockwise. The adjustable range is 0 – 6 mm. (One full turn allows 0.8 mm adjustment.)
SAVE THESE INSTRUCTIONS.
The hook is convenient for hanging the tool temporarily. This hook can be installed on either side of the tool. When changing the installation position, remove the screw with a screwdriver. Install the hook on another side for installation and then secure it with the screw.
Selecting compressor (Fig. 1) The air compressor must comply with the requirements of EN60335-2-34. The air compressor must comply with the requirements of ANSI B19.3. Select a compressor that has ample pressure and air output to assure cost-efficient operation. The graph shows the relation between nailing frequency, applicable pressure and compressor air output. Thus, for example, if nailing takes place at a rate of approximately 55 times per minute at a compression of 1.76 MPa (17.6 bar), a compressor with an air output over 50 liters/minute is required. Pressure regulators must be used to limit air pressure to the rated pressure of the tool where air supply pressure exceeds the tool’s rated pressure. Failure to do so may result in serious injury to tool operator or persons in the vicinity.
If you like to protect the surface of workpiece, attach the nose adapter of contact element. When nailing workpieces with easily-marred surfaces, use the nose adapter. To attach the nose adapter to the contact element, press it onto the contact element as far as it will go.
Selecting air hose (Fig. 2) Use a high pressure resistant air hose. Use an air hose as large and as short as possible to assure continuous, efficient nailing operation.
Disconnect the air hose from the tool. Select nails suit- able for your work. Depress the latch lever and open the magazine cap. (Fig. 9) Select nails suitable for your work. Depress the latch lever and open the magazine cap. Lift and turn the coil support plate so that the arrow with nail size indicated on the coil support plate will point to the corresponding graduation increment marked on the magazine. If the tool is operated with the coil support plate set to the wrong step, poor nail feed or malfunction of the tool may result. (Fig. 10) Place the nail coil over the coil support plate. Uncoil enough nails to reach the feed claw. Place the first nail in the driver channel and the second nail in the feed claw. Place other uncoiled nails on feeder body. Close the magazine cap slowly until it lock after checking to see that the nail coil is set properly in the magazine. (Fig. 11)
Lubrication To insure maximum performance, install an air set (oiler, regulator, air filter) as close as possible to the tool. Adjust the oiler so that one drop of oil will be provided for every 30 nails. (Fig. 3) When an air set is not used, oil the tool with pneumatic tool oil by placing 2 (two) or 3 (three) drops into the air fit- ting. This should be done before and after use. For proper lubrication, the tool must be fired a couple of times after pneumatic tool oil is introduced. (Fig. 4)

Connecting air hose Slip the air socket of the air hose onto the air fitting on the nailer. Be sure that the air socket locks firmly into position when installed onto the air fitting. A hose coupling must be installed on or near the tool in such a way that the pressure reservoir will discharge at the time the air sup- ply coupling is disconnected.
Choose and use nails more than 10 mm longer than total thickness of all workpiece to be fastened by referring to the table below.
CAUTION: • However when the tool is set to the “Intermittent Nail- ing” mode, WITH THE TRIGGER HELD IN A HALF- PULLED POSITION, an unexpected nailing could occur, if contact element is allowed to re-contact against the workpiece or the other surface under the influence of recoil. In order to avoid this unexpected nailing, perform as fol- lows; A. Do not place the contact element against the work-
piece with excessive force. B. Pull the trigger fully and hold it on for 1 – 2 seconds
after nailing. • For No. (1) method, set the change lever to the position. For No. (2) method, set the change lever to the position. After using the change lever to change the nailing method, always make sure that the change lever is properly set to the position for the desired nailing method. (Fig. 14 & 15)
Choose and use nails so that the penetration amount into concrete ranges 10 mm – 15 mm by referring to the table below.
Tear off the output sheet in the direction of the arrow when using the sheet collated nails.
Air exhaust (Fig. 20) Air exhaust direction can be changed easily by rotating the exhaust cover. Change it when necessary.

When the nailer becomes jammed, do as follows: Open the magazine cap and remove the nail coil. Insert a small rod or the like into the ejection port and tap it with a hammer to drive out the nail jamming from the ejection port. Reset the nail coil and close the magazine cap.
Drain tool Remove the hose from the tool. Place the tool so that the air fitting faces down to the floor. Drain as much as possi- ble.
Cleaning of tool Iron dust that adhere to the magnet can be blown off by using an air duster.
Cap (Fig. 23) When not in use, disconnect the hose. Then cap the air fitting with the cap.
Storage When not in use, the nailer should be stored in a warm and dry place.
Maintenance of compressor, air set and air hose After operation, always drain the compressor tank and the air filter. If moisture is allowed to enter the tool, it may result in poor performance and possible tool failure. (Fig. 24 & 25) Check regularly to see if there is sufficient pneumatic oil in the oiler of the air set. Failure to maintain sufficient lubrication will cause O-rings to wear quickly. (Fig. 26) Keep the air hose away from heat (over 60°C, over 140°F), away from chemicals (thinner, strong acids or alkalis). Also, route the hose away from obstacles which it may become dangerously caught on during operation. Hoses must also be directed away from sharp edges and areas which may lead to damage or abrasion to the hose. (Fig. 27)
To maintain product SAFETY and RELIABILITY, repairs, any other maintenance or adjustment should be per- formed by Makita Authorized Service Centers, always using Makita replacement parts.
If you need any assistance for more details regarding these accessories, ask your local Makita service center.