Symbols END106-2 The following show the symbols used for the equipment. Be sure that you understand their meaning before use.
Read instruction manual.
Wear safety glasses.
Do not use on scaffoldings, ladders.
(1) Always assume that the tool contains fasteners. (2) Do not point the tool toward yourself or anyone
READ ALL INSTRUCTIONS.
whether it contains fasteners or not. (3) Do not activate the tool unless the tool is placed
firmly against the workpiece. (4) Respect the tool as a working implement. (5) No horseplay. (6) Do not hold or carry the tool with a finger on the
trigger.

(7) Do not load the tool with fasteners when any one
- when changing one driving location to another
of the operating controls is activated. (8) Do not operate the tool with any power source
involves the use of scaffoldings, stairs, ladders, or ladder alike constructions, e.g. roof laths; - closing boxes or crates; - fitting transportation safety systems e.g. on vehicles

WARNING: • Never use the nailer when the safety elements are not in working order. Using it in that condition may cause a personal injuries and damage. This nailer does not fire nails without activating both the trigger and the safety elements. Before nailing, check the nailer that the safety systems is in working order by following the procedure shown below. (Fig. 6) 1. Make sure that nails are not loaded on the tool before operation. 2. Connect the air hose to the tool. 3. Set the lock lever in the released position. 4. Pull the slide door of the magazine toward yourself. 5. Pull only the trigger. 6. Release the finger from trigger and place the safety element against the workpiece. 7. Bring the safety element off the workpiece, pull the trigger and then place the safety element against the workpiece. 8. If the nailer works between 5 - 7, the safety elements are not in working order. (Fig. 7 & 8)
SAVE THESE INSTRUCTIONS.
Selecting compressor (Fig. 2) • Select a compressor that has ample pressure and air output to assure cost-efficient operation. The graph shows the relation between nailing frequency, applicable pressure and compressor air output. Thus, for example, if nailing takes place at a rate of approximately 60 times per minute at a compression of 1.76 MPa (17.6 bar), a compressor with an air output over 45 L/min is required. Pressure regulators must be used to limit air pressure to the rated pressure of the tool where air supply pressure exceeds the tool's rated pressure. Failure to do so may result in serious injury to tool operator or persons in the vicinity.
Using the trigger lock The tool has trigger lock to avoid accidents by an unintentional start. The trigger lock makes the trigger unmovable and let the tool cause no firing. To lock the trigger, set the lock lever in the “LOCK ” position. Before nailing, set the lock lever in the “FREE ” position. When not in use, always set it in the “LOCK ” position and disconnect the hose from the tool. (Fig. 9 & 10)
CAUTION: • Always lock the trigger and disconnect the hose before adjusting the depth of nailing. (Fig. 11 & 12) To adjust the depth of nailing, turn the adjuster. The depth of nailing is the deepest when the adjuster is turned fully in the A direction shown in the figure. It will become shallower as the adjuster is turned in the B direction.
Lubrication (Fig. 4) To insure maximum performance, install an air set (oiler, regulator, air filter) as close as possible to the tool. Adjust the oiler so that one drop of oil will be provided for every 50 nails. When an air set is not used, oil the tool with pneumatic tool oil by placing 2 (two) or 3 (three) drops into the air fitting. This should be done before and after use. For proper lubrication, the tool must be fired a couple of times after pneumatic tool oil is introduced. (Fig. 5)

Jammed nailer
CAUTION: • Always lock the trigger and disconnect the hose before loading the nailer. (Fig. 14) Press the lever and open the sliding door of the magazine by pulling it toward yourself with the lever pressed. (Fig. 15) Align the tip of nails with the grooves at the bottom of the magazine and push the whole part of nails toward the firing opening. (Fig. 16) Close the slide door firmly. Close the sliding door.
CAUTION: • Always lock the trigger, disconnect the hose and remove the nails from the magazine before cleaning a jam. (Fig. 22) Open the slide door and remove nails from the magazine. Press the short top end of the hex wrench and take it out from the holder. (Fig. 23) Remove two screws with the hex wrench that are securing the front driver guide. Take the jammed nails from the nail guide groove that has appeared. When it is difficult to take out the jammed nails, further remove two screws with the hex wrench that are securing the rear driver guide. Then take them out.
CAUTION: Always lock the trigger and disconnect the hose before loading the nailer. (Fig. 17) To prevent the surface of workpiece from being scratched or damaged, use the nose adapter. Before attaching the nose adapter, remove two screws with the hex wrench that are securing the front driver guide. Attach the nose adapter so that its protrusion fit into the groove in the contact element. (Fig. 18) Store the nose adapter in place when not in use. The place for storage is at the back of the slide door. Open the slide door slightly and set the nose adapter onto the holder with the slide door slightly opened, and then close the slide door. Total two nose adapters can be stored. (Fig. 19) To take the nose adapter out of the holder easily, push it out using a hex wrench from back of the slide door.
Nails (Fig. 24) Handle nail coils and their box carefully. If the nail coils have been handled roughly, they may be out of shape or their connector breaks, causing poor nail feed. Avoid storing nails in a very humid or hot place or place exposed to direct sunlight. (Fig. 25)
Maintenance of nailer (Fig. 26) Always check the tool for its overall condition and loose screws before operation. Tighten as required. (Fig. 27) With tool disconnected, make daily inspection to assure free movement of the contact element and trigger. Do not use tool if the contact element or trigger sticks or binds.
CAUTION: • When connecting air hose, never place a finger on the trigger. Lock the trigger and slip the air socket of the air hose onto the air fitting on the nailer. Be sure that the air socket locks firmly into position when installed onto the air fitting. A hose coupling must be installed on or near the tool in such a way that the pressure reservoir will discharge at the time the air supply coupling is disconnected.
Draining the tool (Fig. 28) Disconnect the hose from the tool. Place the tool so that the air fitting faces down to the floor. Drain as much as possible.
Cleaning of tool Blow off dust by using an air duster.
Cap (Fig. 29) When not in use, lock the trigger and disconnect the hose. Then cap the air fitting port. (Fig. 30) When the tool is not to be used for an extended period of time, lubricate the tool using pneumatic tool oil and store the tool in a safe place. Avoid exposure to direct sunlight and/or humid or hot environment. (Fig. 31)
Maintenance of compressor, air set and air hose (Fig. 32 & 33) After operation, always drain the compressor tank and the air filter. If moisture is allowed to enter the tool, It may result in poor performance and possible tool failure. Check regularly to see if there is sufficient pneumatic oil in the oiler of the air set. Failure to maintain sufficient lubrication will cause O-rings to wear quickly. (Fig. 34) Keep the air hose away from heat (over 60°C, over 140°F), away from chemicals (thinner, strong acids or alkalis). Also, route the hose away from obstacles which it may become dangerously caught on during operation.
Anti dry fire mechanism This tool is equipped with an anti dry fire mechanism. When there are a undepressed position to prevent the tool from being activated. Load more nails to resume operation.

Hoses must also be directed away from sharp edges and areas which may lead to damage or abrasion to the hose. (Fig. 35) To maintain product SAFETY and RELIABILITY, repairs, any other maintenance and adjustment should be performed by Makita Authorized Service Centers, always using Makita replacement parts.
For European countries only ENG045-2 Noise and Vibration The typical A-weighted noise levels are sound pressure level: 74 dB (A) sound power level: 87 dB (A). Wear ear protection The typical weighted root mean square acceleration value is not more than 2.5 m/s2
These values have been obtained according to EN792.
EC-DECLARATION OF CONFORMITY ENH013-5 We declare under our sole responsibility that this product is in compliance with the following standards of standardized documents; EN792 in accordance with Council Directives, 98/37/EC.
Responsible Manufacturer: Makita Corporation 3-11-8, Sumiyoshi-cho, Anjo, Aichi, JAPAN Authorized Representative in Europe: Makita International Europe Ltd. Michigan Drive, Tongwell, Milton Keynes, Bucks MK15 8JD, ENGLAND
Tomoyasu Kato · Director
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.