It is important to read all instructions and warnings contained in this booklet thoroughly before use and to look after the booklet carefully. Your new frontal thermometer measures body temperature precisely and painlessly. The new infrared recording technology produces greater reliability and longer life for the instrument. The innovative non-contact mode makes it ideal for measurements on children, even during sleep. It is easy to use, allowing recording of body temperature and ambient temperature. With a large LCD display for easy reading that shows the ambient temperature continuously. It has an acoustic signal to indicate body temperature measurement completed, and has automatic shut-off after one minute of inactivity which prolongs battery life. It records the temperature in Celsius (°C) and Fahrenheit (°F). It stores the last 25 measurements to allow checking for changes in the readings. NB: The temperature shown on the display is equivalent to oral temperature, which means the temperature measured at the forehead is translated as if the temperature had been recorded in the mouth. Laica S.p.A. - Viale del Lavoro, 10 - Fract. Ponte 36021 Barbarano Vicentino (VI) - ITALIE Made in China
the direct rays of the sun, and do not store it near sources of heat. Store in a clean, dry place. 5) Do not touch the probe with your fingers and do not dismantle the thermometer. 6) Do not immerse the appliance in water or any other liquid. 7) Do not use the forehead thermometer to measure rectal, oral or underarm temperatures. 8) Measurement accuracy can be compromised by: pronounced sweating of the forehead, taking vasoconstricting medication and skin irritations. 9) Clean the forehead where the probe will be positioned before each recording. 10) Measure the temperature away from direct sunlight and from wind. 11) This thermometer must be used to record the temperature of the forehead (at a distance of 1 to 3 cm). 12) Holding the thermometer in your hand for too long can cause a lower recording of body temperature by the probe. 13) Do not measure temperature for thirty minutes after either physical activity or a bath.
Each type of thermometer is used to measure body temperature in a specific part of the body. Forehead thermometers are only for measurements on the forehead. Ear thermometers only for measuring in the ear. Mercury thermometers are for traditional rectal, underarm and oral recording. Depending on the point where the measurement is made, a different temperature value is obtained. The variation can be between 0.2-1°C. You cannot compare the temperatures measured with different measuring methods. It is therefore necessary to consider, when self-diagnosing or reporting to your doctor, the type of thermometer and where on the body the temperature was measured.
COMPONENTS 1) LCD DISPLAY 2) O/I BUTTON 3) SCAN BUTTON 4) MEASUREMENT PROBE 5) BATTERY COMPARTMENT 6) HOLE FOR OPENING BATTERY COMPARTMENT 7) BATTERY
FEVER Fever should be considered a symptom and not a disease. In general, it is a sign that the body is fighting an infection. In fact, it is a defence mechanism of the body characterised by an increase in body temperature above 37°C and increased heart and breathing rates. Normal temperature within the body is about 37.5°C and this is in fact the value measured with the rectal method. The temperature measured in the mouth is about 0.5°C less (37°C) while the underarm recording is 1°C less (36.5°C). From this we can deduce the importance of a correct recording of the temperature that should be carried out with an accurate instrument, and if possible not at a time when body temperature may be increased for physiological reasons (upon waking, after meals). In a healthy person the
INSERTION/REPLACEMENT OF BATTERIES The battery must be replaced as soon as the display shows the “battery low” symbol (see Image 1). Before replacing the battery, check that the thermometer is in standby mode to avoid damaging the mechanism. 1) To open the battery cover, insert a pointed object into the hole above the battery compartment (see fig. 1), push down and at the same time slide the cover in the direction of the arrow. 2) Insert a pointed object, such as a pen, into the battery compartment and lift the battery so as to remove it. 3) Insert a new battery under the metal hook to the left and press down the battery to the right until you hear a click. The positive terminal must be facing up. At this point the thermometer will emit a short beep.
GENERAL WARNINGS 1) Self-measuring is for checking, not diagnosis or treatment. Unusual values should always be discussed with your doctor. Under no circumstances should you alter the dosages of any medication prescribed by your doctor. 2) The forehead thermometer is a sensitive instrument. Handle with care and do not expose it to mechanical shocks. Do not squeeze, bend, drop or take apart the thermometer. 3) Keep out of reach of children. 4) Do not expose the thermometer to extreme temperatures or to

and display the ambient temperature (icon , see fig. 4), or you can turn it off by pressing and holding the O/I button for a few seconds.
CELSIUS/FAHRENHEIT This thermometer can measure temperature in Celsius and Fahrenheit. If you wish to change the unit of measurement, proceed as follows: 1) When the thermometer is in stand-by mode (fig. 4), press and hold the SCAN button for a few seconds and simultaneously press the O/I button until the display shows°F (or°C), see fig. 5. 2) The thermometer will beep twice. At this point, release the buttons. Now the unit of measurement has been changed. Proceed with the measurement as described in the “INSTRUCTIONS FOR PROPER USE” section.
attention to it during cleaning. Allow the probe to dry completely for at least 30 minutes. The body of the thermometer should be cleaned with a soft, dry cloth. THE BODY OF THE THERMOMETER MUST NOT BE WASHED WITH WATER. Never use abrasive products and do not immerse the thermometer in water or other liquids. Keep the thermometer in a clean, dry place, away from direct sunlight.
RECORDING THE AMBIENT TEMPERATURE ( ) This thermometer can record the ambient temperature. The appliance after 1 minute of non-use switches to standby mode and displays the ambient temperature ( ). NB: Only after 15 minutes of non-use in standby mode ( ) is the temperature shown on the display equivalent to the actual ambient temperature. When turned on again, the display shows the forehead temperature recording function.
INSTRUCTIONS FOR PROPER USE FOREHEAD TEMPERATURE RECORDING ( ) Attention! In order to ensure accurate recording of the temperature, clean the probe in its entirety with a cotton swab moistened with alcohol after each use. Make sure that the probe is completely dry before use. IMPROPER CLEANING OF THE PROBE CAN CAUSE UNRELIABLE TEMPERATURE RECORDINGS 1) Clean and dry the forehead where you will position the probe. 2) Turn on the thermometer by pressing the O/I button on the display. All the function symbols will appear (self-test). After a few seconds the display will show the forehead measurement icon (see fig. 2) and will beep twice. At this point, the thermometer is ready for use. 3) Position the probe over the forehead at a distance of about 1 to 3 cm. 4) Press and hold the SCAN button until the thermometer beeps. At this point, release the SCAN button, the appliance will give two short beeps and the display will show the temperature measured. When you proceed with a new measurement, the display will show in the top right corner the preceding measurement and the icon (see fig. 3). When the temperature measured is above or equal to 37.5°C (99.5°F) the thermometer will emit 3 short beeps. NB: The temperature shown on the display is equivalent to the oral temperature, i.e. the temperature recorded at the forehead is translated as if the temperature had been recorded in the mouth. 5) After 1 minute of non-use the appliance will switch to standby mode
MEMORY FUNCTION This appliance stores the last 25 measurements to allow you to assess any changes. The measurements are stored automatically after the thermometer goes into standby mode. Only the forehead temperatures are stored. After 25 measurements, the oldest measurement will be cancelled after each new measurement. To recall stored measurements, activate the thermometer and press the O/I button (each press of the button causes the data in memory to scroll). On pressing the button, the display shows the serial number of each measurement in memory (1 = most recent measurement, 25 = oldest). At top left of the display the M symbol appears (see fig. 6). When you release the button, instead of the serial number, the display shows the measured temperature. Stored values are displayed for about 1 minute. About 1 minute after you release the O/I button, the appliance goes into standby mode and displays the ambient temperature ( icon , see fig. 4), or you can turn it off by pressing and holding the O/I button for a few seconds.
temperatures Solution: Check the correct positioning of the probe at the forehead. Reread the section, “Forehead Temperature Recording”. The sensor may be dirty, clean it before and/or after each use with a cotton swab and alcohol.
INFRARED SCAN FUNCTION ( ) This thermometer can record the temperature of warm surfaces or liquids (such as milk, water, ...). 1) Turn on the thermometer by pressing the O/I button. The display will show all the function symbols (self-test) and after a few seconds the display will show the forehead measurement icon (see fig. 2) and will beep twice. 2) Press and hold the “O/I” button for a few seconds and simultaneously press the “SCAN” button. The display will show the icon ( disappears). 3) To measure temperature using the SCAN function bring the thermometer to the surface in question (container of water, milk, ...) as shown in fig. 7. If you press and hold the SCAN button, the temperature is continuously updated. 4) The apparatus after 1 minute of non-use switches to standby mode and displays the ambient temperature ( icon , see fig. 4), or you can turn it off by pressing and holding the O/I button for a few seconds. When turned on again, the display shows the forehead temperature recording function ( ). NB: Never immerse the probe in any kind of liquid.
Image 1 Problem: Low battery. Solution: Replace the battery.
Image 2 Problem: The display shows “Er1”. The measurement was made before device setup. Solution: Wait a few seconds until the icon stops flashing.
Image 3 Problem: The display shows “Er3”. The room temperature is not between 10°C and 40°C / 50°F and 104°F. Solution: The thermometer must already be in the room in which you will perform the measurement about half an hour before taking measurement while the person must be in the room at least 30 minutes before too. (The room temperature must be between 10°C and 40°C / 50°F and 104°F).
CLEANING AND MAINTENANCE Before and/or after each use, clean the probe of the thermometer with a cotton swab moistened with alcohol to ensure accurate readings. The probe is the most delicate part of the thermometer, pay particular

Image 4 Problem: Error 5~9, the appliance did not work properly. Solution: Remove the battery, wait 1 minute and put it back into its compartment. If the error persists, contact your dealer.
Battery: 1x3V CR2032 lithium Display: Liquid Crystal Shutdown: switches off automatically after one minute of non-use Range of body temperature measurement: 34°C to 42.2°C (93.2°F to 108°F) Range of ambient temperature measurement: 10°C to 40°C (50°F to 104°F) Measuring Range with SCAN function -22°C to 80°C (-7.6°F to 176°F) Resolution: 0.1°C Operating conditions: 10°C to 40°C (50°F to 104°F), RH 15%~85% Atmospheric Pressure: 800 - 1013 hPa Storage conditions: -20°C to 50°C (-4°F to 122°F), RH
In cases where there are anomalies during operation, it is recommended to distance the device from any other equipment that could cause electromagnetic interference and check for the restoration of performance. In all cases, in the event of doubt, contact Customer Support or see the tables relating to electromagnetic emissions at the end of these instructions.
The warranty covers only production defects and does not apply, if the damage is caused by accidental events, misuse, negligence or improper use of the product. Use the supplied accessories only; the use of other accessories invalidate the warranty cover. Do not open the equipment for any reason whatsoever; the opening or the tampering of the equipment, definitely invalidate the warranty. Warranty does not apply to parts subject to tear and wear along the use, as well as to batteries, when they are included. Warranty decays after 2 years from the purchase date. In this case, technical service interventions will be carried out against payment. Information on technical service interventions, under warranty terms or against payment, may be requested by writing at info@laica.com. Repair or replacement of products covered by the warranty terms are free of charge. In case of faults, refer to the dealer; DO NOT send anything directly to LAICA. All interventions covered by warranty (including product replacement or the replacement of any of its parts) shall not be meant to extend the duration of the original warranty period of the replaced product. The manufacturer cannot be made liable for any damages that may be caused, directly or indirectly, to people, things and pets resulting from the inobservance of the provisions contained in the suitable user manual, especially with reference to the instructions related to installation, use and maintenance of the equipment. Being constantly involved in improving its own products, Laica reserves the right to modify its product, totally or partially, with reference to any production need, without that this involves any responsibility whatsoever by Laica or its dealers.
Image 5 Problem: The display shows the message “Hi”. The temperature measured at the forehead exceeds 42.2°C – 108°F. The temperature measured with the SCAN function exceeds 80°C – 176°F. Solution: Check the integrity of the probe and take a new measurement.
DISPOSAL PROCEDURE (Dir. 2012/19/Eu-WEEE)
The symbol on the bottom of the device indicates the separated collection of electric and electronic equipment. At the end of life of the device, do not dispose it as mixed solid municipal waste, but dispose it referring to a specific collection centre located in your area or returning it to the distributor, when buying a new device of the same type to be used with the same functions. If the appliance to be disposed of is less than 25 cm, it can be returned to a retail location that is over 400 m2 without having to purchase a new, similar device. This procedure of separated collection of electric and electronic devices is carried out forecasting a European environmental policy aiming at safeguarding, protecting and improving environment quality, as well as avoiding potential effects on human health due to the presence of hazardous substances in such equipment or to an improper use of the same or of parts of the same. Caution! The wrong disposal of electric and electronic equipment may involve sanctions.
Image 6 Problem: The display shows the message “Lo”. The temperature measured at the forehead is less than 34°C – 93.2°F. The temperature measured using the SCAN function is less than -22°C – -7.6°F. Solution: Check that the probe is clean and take a new measurement.
Image 7 Problem: The appliance hangs on self-test. Solution: Replace the battery.
ELECTROMAGNETIC COMPATIBILITY This device complies with current regulations relating to electromagnetic compatibility (EMC) and has been designed to be used in the home. Its emissions are extremely small and are unlikely to generate interference with other equipment. In the event that it is to be used in close proximity to other equipment, it is recommended to follow the instructions given in the tables at the end of the instructions for use. Certain mobile communications devices and radio systems may have an effect on the operation of this device.
WARRANTY This equipment is covered by a 2-year warranty starting from the purchase date, which has to be proven by means of the stamp or signature of the dealer and by the fiscal payment receipt that shall be kept enclosed to this document. This warranty period complies with the laws in force and applies only in case the consumer is an individual. Laica products are designed for domestic use only; therefore, their use for commercial purposes is forbidden.
figure indicates the degree of protection against penetration by solid foreign bodies (from 0 to 6) and the second figure the degree of protection against penetration by liquids (from 0 to 8).
In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.
Was die auf dem Display angezeigten Fehlercodes bedeuten und wie man sie behebt.
| Code | Bedeutung | Lösung | |
|---|---|---|---|
| IP22 | Degree of protection of electrical equipment covers, where the first | p.3 |
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.