MANUAL (p. 2) Optical Smoke Alarm

ANLEITUNG (S. 5) Optischer Rauchmelder

MODE D’EMPLOI (p. 9) Détecteur de fumée optique

GEBRUIKSAANWIJZING (p. 13) Optische rookmelder

MANUALE (p. 16) Allarme Fumo Ottico

MANUAL DE USO (p. 20) Alarma óptica de humo

HASZNÁLATI ÚTMUTATÓ (o. 23.) Optikai füstérzékelő riasztó

KÄYTTÖOHJE (s. 27) Optinen palovaroitin

BRUKSANVISNING (s. 30) Optisk rökdetektor

NÁVOD K POUŽITÍ (s. 34) Optický kouřový alarm

MANUAL DE UTILIZARE (p. 37) Alarmă de fum cu senzor optic

ΕΓΧΕΙΡΙ∆ΙΟ XPHΣHΣ (σελ. 41) Οπτικός Συναγερμός Καπνού

BRUGERVEJLEDNING (s. 44) Optisk røgalarm

VEILEDNING (s. 48) Optisk røykvarsler

ИНСТРУКЦИЯ (стр. 51) Оптический сигнализатор дыма

2012-09-26

Page 3 of the Konig Electronic SEC-SA100 user manual — 1. Test button / battery indicator
Seite 3 · Zum Vergrößern klicken
Seite 3

Product and user description:

Konig Electronic SEC-SA100 — Product and user description: diagram (page 3)
Abb. 2 · Product and user description:
Konig Electronic SEC-SA100 — Product and user description: diagram (page 3)
Abb. 3 · Product and user description:

1. Test button / battery indicator

Testing the smoke alarm Like any other electronic device, smoke alarms are not foolproof. Smoke alarms contain electronic components that can fail or wear out at any time. We recommended that you test the smoke alarm every week to make sure it is working properly. Push and hold the test button until the alarm sounds for a few seconds. If it does not sound, check if the battery indicator flashes once every 45 seconds. If this is not the case, replace the battery immediately.

Battery indicator. The battery indicator flashes every 45 seconds to show the smoke alarm is working properly. When the battery indicator flashes and gives a short beep sound, it is indicating that the battery has low capacity and should be replaced immediately.

2. Mounting plate
Konig Electronic SEC-SA100 — 1. Test button / battery indicator diagram (page 3)
Abb. 4 · 1. Test button / battery indicator
3. Mounting holes Use the supplied screws and plugs to mount the mounting plate to the ceiling.
4. Remove the mounting plate Turn the mounting plate of the smoke alarm counterclockwise to get access to the battery compartment of the smoke alarm.
5. Battery compartment
6. Safety catch The safety catch prevents the smoke alarm being returned to the mounting plate without inserting the battery first.
7. Battery connector Take off the plastic seal of the battery and connect the battery with the battery connector. After placing the battery test the alarm with the test button to ensure it is working properly (see testing the smoke alarm ). When the mounting plate is mounted and the smoke alarm tested after inserting the battery, place the smoke alarm on the mounting plate by turning it clockwise.
Page 4 of the Konig Electronic SEC-SA100 user manual — Installation instructions:
Seite 4 · Zum Vergrößern klicken
Seite 4

Read the following chapter to find out which places in your house are the best choices to mount the smoke alarm(s).

Installation instructions:

Install a smoke alarm in every room or area on every level of the home Smoke may not reach the smoke alarm if it is installed in only one room or area. If a fire starts in another room or area than where the smoke alarm is installed, the smoke alarm will not detect the smoke, or it will detect it too late. A smoke alarm will not promptly detect a fire except in the room or area in which it is installed. Place at least one smoke alarm in every room/area that is on your way from the bedroom to the front door. It is recommended to make a flight plan and practice it with the household members in case of an emergency. The requirements for the installation of a smoke alarm may differ per region. Please contact your local authorities for possible additional requirements. Example for the installation of smoke alarms:

Konig Electronic SEC-SA100 — Installation instructions: diagram (page 4)
Abb. 5 · Installation instructions:
Konig Electronic SEC-SA100 — Installation instructions: diagram (page 4)
Abb. 6 · Installation instructions:

On ceilings Install smoke alarms as close as possible to the centre of the ceiling. If this is not possible, install the smoke alarm at least 30 to 50 cm from the wall or corner (due to dead air space).

Rooms with gabled ceilings Install the smoke alarm 90 cm from the highest point (due to dead air space). When installing a smoke alarm in a corridor with a length of 7.5 metres or more. It is recommended to install a smoke alarm in the beginning and the end of the corridor.

Show 12 more labels / short text on this page
Attic · Bedroom · Corridor · Bedroom · Corridor · Kitchen · Corridor · Basement Corridor · Living room · Ceiling mounting · minimum 30/50 cm · Minimum 90 cm

Frage zu Konig Electronic SEC-SA100 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Konig Electronic SEC-SA100

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Konig Electronic SEC-SA100 PDF-Anleitung

57 Seiten·1.7 MB·Sicherheitstechnik·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…