Benutzeranleitung / Produktwartung RS232 des Produzenten ACTiSYS
Zur Seite of 18
The Wireless Connectivity Expert 48511 Warm Springs Blvd., Suite 206, Fremont, CA 94539, USA Tel: +1-510-490-8024 F ax: +1-510-623-7268 Web: http://www.actisys.com E-mail: irda-info@actisys.com ACT-BT5701S v2 Bluetooth RS232 Adapter Class 1 User’s Manual December 06, 2006 Version 2.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual TABLE OF CONTENT REVISION HISTORY ................................................................................................ 3 1. OVERVIEW ..........................................
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual REVISION HISTORY Revision History Revision Date Comment 0.1 03/22/2006 • Initial draft version 1.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual Copyright 2005-2006 ACTiSYS Corp. Page 4 of 18 ACTiSYS Confidential Information Dec 06, 2006 Version 2.0 1. OVERVIEW ACTiSYS Bluetooth RS232 adapter brings wireless Bluetooth technology to your RS232 serial equipment, allowing you to eliminate conventional cables.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 6. FEATURES ! Bluetooth embedded solution for RS232 cable replacement, applications such as industrial remote control devices. ! Configurable baud rate 1.2k ~1843.2k bps. ! True Plug-n-Play; no driver required.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 7.2 Null Modem Connection For Configuring Parameters Figure 2: Null Modem Connection For Configuring Parameters 7.3 Null Modem Connection For Normal Operation Figure 3: Null Modem Connection For Normal Operation Copyright 2005-2006 ACTiSYS Corp.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 8. FACTORY SETTING PARAMETERS When using ACT-BT5701S v2 with your serial devices, make sure all the settings match on both sides.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 9. CONFIGURATION PARAMETERS Figure 4: Configuration Parameters Window 9.1. UART Format • Baud Rate : 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600 or 1843200 bps selectable.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual • Master or Slave Mode : User can select device as a master or a slave. If you configure it as a Master then you need to assign Slave BD address (Predefined Remote BD Address).
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual Figure 5: Null Modem Adapter Connect ACT-BT5701S v2 as shown in Figure 6. User has to take care of direction of DB9 null modem adapter. During configuring parameters, black end of null modem adapter should be connected to ACT-BT5701S v2.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual NOTE : For Normal Operation the null modem adapter must be in reverse direction. Black end should be connected to PC COM port while white end should be connected to ACT-BT5701S v2. Figure 7 shows this connection.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 10.4. Then you will see the screen below. Click Finish to complete the procedure. 10.5. Now run utility program ACT-BT5701Sv2.EXE from Start>Programs> ACTiSYS> ACT- BT5701S v2 . You will see the following screen: Figure 8: Configuration Utility 10.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual Figure 9: Read Configuration Complete Copyright 2005-2006 ACTiSYS Corp. Page 13 of 18 ACTiSYS Confidential Information Dec 06, 2006 Version 2.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 10.7. After all parameters have been set, click “ Write Configuration” button to save all the settings . See Figure 10. Figure 10: Write Configuration Progress 11. CONNECTION FOR NORMAL OPERATION For normal operation mode, the null modem adapter must be in reverse direction.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 12. LED BEHAVIOR LED CATEGORY LED BEHAVIOR STATUS On Active (Connect) Mode Flash Fast Data Transfer Mode “ACT” LED Flash Slow Stand By Mode On Power on “POWER” LED Off Power off 13.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 13.2 Generic Specifications FUNCTION ACT-BT5701S v2 Standard Bluetooth 1.2 Interface RS232 Configurable Parameters Master or Slave mode,.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual A8. User can give power to DC JACK pin through power adaptor 7.5V @300mA or give unregulated 5 ~ 12 VDC to pin 1 of the male connector of ACT-BT5701S v2. Q9. I am not able to configure the new parameters.
The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual Copyright 2005-2006 ACTiSYS Corp. Page 18 of 18 16. CONTACT INFORMATION ACTiSYS Corporation 48511 Warm Springs Blvd, Suite 206 Fremont, CA 94539, USA TEL: +1-510-490-8024, FAX: +1-510-623-7268 E-Mail: irda-info@actisys.
Ein wichtiger Punkt beim Kauf des Geräts ACTiSYS RS232 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie ACTiSYS RS232 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für ACTiSYS RS232 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von ACTiSYS RS232 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über ACTiSYS RS232 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon ACTiSYS RS232 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von ACTiSYS RS232 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit ACTiSYS RS232. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei ACTiSYS RS232 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.