DELIVERY AND UNPACKING : When you take out the unit from the box, please check carefully if there isn’t any damage caused by transport. If this is the case, please contact your dealer immediately. Every appliance has been thoroughly check when it left the factory. IMPORTANT : After unpacking, you need to leaf the appliance upright and not in use. When you don’t follow this procedure, you risk of damaging the unit. When you don’t want the hot air to enter the room, you need to guide the hose outside.

SAFETY REGULATIONS : This appliance has been designed for a use with 220V-240V. Don’t use a extension cord of any kind.. Always turn off the appliance and remove the plug from the socket before doing any maintenance. Don’t every place the appliance horizontally. This can damage the compressor. Only use the appliance upright on a flat surface. When you turn off the appliance, leaf it off for 3 to 4 minutes before you turn it on again. Always let your appliance be repaired by an authorised dealer. The compressor has a delay time of 3 minutes after you turn off the appliance.

DESCRIPTION OF THE APPLIANCE : 1. Control panel 2. Upper air outlet 3. Handle 4. Storage space remote control. 5. Water plate. 6. Wheels 7. Air outlet 8. Air inlet 9. Permanente drainage 10. Plastic connector 11. Air exhaust connector 12. Air exhaust duct 13. Remote control 14. Water drainage

Domo DO320A diagram (page 1)
Abb. 1
Page 2 of the Domo DO320A user manual
Seite 2 · Zum Vergrößern klicken
Seite 2

LCD- DISPLAY 1. Temperature setting. 2. Auto mode 3. Ventilation speed 4. Cool mode 5. Ventilation mode 6. Ventilation direction 7. Deshumidification mode 8. Timer 9. Error code

Domo DO320A diagram (page 2)
Abb. 2

CONTROL PANEL : 1. Run/stand by switch 2. Mode button 3. Ventilation speed button 4. LCD-display 5. Temperature switch 6. Timer knob 7. Oscillation knob

1 2 3 4 5 6 7

Domo DO320A diagram (page 2)
Abb. 3
Domo DO320A diagram (page 2)
Abb. 4

REMOTE CONTROL 1. Oscillation knob 2. Mode knob 3. Temperature knob 4. Ventilation speed button 5. Timer switch 6. run/stand-by switch

OPERATION OF THE CONTROL PANEL: run/stand-by SWITCH : For turning on and off of the unit.

MODE BUTTON : There are 4 different modes from which you can choose : Auto Cooling Dehumidify Ventilation

VENTILATION SPEED BUTTON : You can choose three different speeds : slow, medium or high.

Page 3 of the Domo DO320A user manual
Seite 3 · Zum Vergrößern klicken
Seite 3

Temperature button : As soon as you turn on the airco a temperature will be displayed (this is mostly differ- ent from the room temperature). Use the arrows on the temperature button to lower or raise the temperature. The temperature can vary from 15°C up to 31°C. For best use of your airco, first determine the temperature and afterwards select the mode. This prevents unnecessary strain on different parts of the airco. Timer button : Press the timer button. Use the arrows on the timer button to program the aircondi- tioner. When the appliance is on, you can program it to turn it off. When the appliance is off, you can program it to turn on. (remember to put the on/off button in the on posi- tion when you program the airco to turn on.) The maximum programmable time is 12 hours. Oscillation knob: For starting or stopping the oscillation in the left/right direction.

FUNCTIONS Cooling function : Make sure the drip tank is put well in place. Make sure the exhaust hose is properly installed. When you want to cool you always have to guide the hose through a window to the outside, to remove the hot air from the room. Press the mode button a few time until the cool function is activated. Press the tem- perature button a few times to select the desired temperature. Press the ventilation speed button to select the desired ventilation speed. There are three speeds : slow, medium or fast.

To make the cooling optimal, take note of the following : - When the room is in direct contact with the sun, close the curtains. - Never place the appliance near a heating source.

Dehumidification function : Keep doors and windows closed to enlarge the effect of dehumidification. Make sure the drip tank is well in place. Press the mode button a few times to select the dehumidification function. The speed of dehumidification can not be changed. When you only use the appliance to dehumidify you don’t need to use the exhaust hose.

Ventilation function : Press the mode button a few times to start the ventilation function. On the display is shown a fan symbol. Press the ventilation speed button to determine the ventilation speed.

Page 4 of the Domo DO320A user manual
Seite 4 · Zum Vergrößern klicken
Seite 4

CONNECTING THE EXHAUST HOSE Place the rectangular piece of the exhaust hose on the air outlet of the appliance. Place the other end through a nearby window. Attention : the length of the hose must be between 500mm and 2000mm. When you place the exhaust hose on the appliance, try to keep the hose horizontally. The height of the opening through which you guide the exhaust hose can vary from 40 cm up to 130 cm.

WATER DRAINAGE When the airconditioner is working in the cool mode or dehumidification mode the condensation water will be drained into the drip tank. When the tank is full this will be indicated on the display en a buzzing sound will be heard. On the display is shown the code “E4”. After three minutes the appliance will turn off. Remove the water from the airco as follows :

- Place the water plate under the water drainage. - Remove the rubber fitting from the water drainage and let the water flow out. - Place the rubber fitting back on the water drainage. - Empty the water plate.

PERMANENT WATER DRAINAGE Press the drainage at the back of the unit until it points down. (for the position of the drainage please check the drawing at the beginning of the booklet.) Make sure the drainage is only pointing down when you want a permanent drainage. Otherwise the drainage will leak. Keep the drainage down and connect the drain tube. When you want to remove the drain tube, take hold of the drainage to prevent damage.

CLEANING AND MAINTENANCE Remove the plug from the socket before starting the maintenance. Don’t use any cleaning products. Use a soft dry cloth. Air filters : When the filters are covered in dust, the appliance won’t function correctly anymore. Clean the filters every 14 days. Never use the appliance without filters. To remove dust, use a vacuum cleaner. When the filters are very dirty, clean them in lukewarm water. The water cannot be warmer than 40°C. Let the filters dry.

Page 5 of the Domo DO320A user manual
Seite 5 · Zum Vergrößern klicken
Seite 5

LINEA 2000 - Industriezone Klein Gent - Bouwelven 12A - 2280 Grobbendonk - Tel 014/21.71.91 - Fax : 014/21,54,63

Frage zu Domo DO320A stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Domo DO320A

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Domo DO320A PDF-Anleitung

26 Seiten·507 KB·Klimaanlage·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…