Battery Installation and Operating Manual. . . 8
Batterie Montage- und Bedienungsanleitung 30
Batterie Instructions de montage et de service 54
Batería Instrucciones de montaje y de uso . 76
Batteria Istruzioni di montaggio e d’uso 99
STORE
Accu Montagehandleiding en gebruiksaanwijzing 121
Batteri Monterings- og betjeningsvejledning 144
Batteri Monterings- och bruksanvisning . . 165
Akumulator Instrukcja montażu i obsługi 277
Batteri Monterings- og bruksanvisning . . . 186
Baterie Návod k montáži a obsluze 301
Akku Asennus- ja käyttöohje 207
Batéria Návod na montáž a uvedenie do prevádzky 323
Bateria Instruções de montagem e manual de instruções 228
Akkumulátor Szerelési és használati útmutató . 345
Батарея Инструкция по монтажу и эксплуатации 251
















eStore Explanation of symbols
required action is described step-by-step.
✓This symbol describes the result of an action.
Fig. 1 5, page 3: This refers to an element in an illustration. In this case, item 5 in figure 1 on page 3.

The manufacturer accepts no liability for damage in the following cases:
Damage to the product resulting from mechanical influences and excess
Alterations to the product without express permission from the manu-
Use for purposes other than those described in the operating manual
In the event of fire, use a fire extinguisher which is suitable for
Do not use the device if the device itself or its connection cables
are visibly damaged.
This device may only be repaired by qualified personnel. Inade-
quate repairs may cause serious hazards.
Persons whose physical sensory or mental capacities prevent
them from using this device safely should not operate it without the supervision of a responsible adult.
Electrical devices are not toys!
Always keep and use the device out of the reach of children.
Children must be supervised to ensure that they do not play with
the device.

eStore Scope of delivery
Check that the voltage specification on the type plate is the
same as that of the power supply.
Ensure that other objects cannot cause a short circuit on the
contacts of the device.
Ensure that the positive [+] and negative [-] terminals never
come into contact.
If cables have to be led through sharp-edged walls, use a cable
duct or cable bushes!
Do not lay any loose or sharp bent cables against electric-
conducting materials (metal).
Do not touch exposed cables with your bare hands. This applies
Only use the device in closed, well-ventilated rooms. !
CAUTION!
Do not operate the device
– In salty, wet or damp environments – In the vicinity of corrosive fumes – In the vicinity of combustible materials – In areas where there is a danger of explosions.
Do not pull on cables.
Installation and operating manual
eStore battery

Available as accessories or spare parts (not included in the scope of delivery):
Part designation Item number
eStore BUS cable Kit RJ11 pin to pin and eStore ID decals For communication between eStore units in multiple eStores, when using eStore Bus
eStore configuration kit Male – Male USB cable and CD For setup of multiple eStores – installers only
eStore eCore BUS cable Cat5 LAN cable, RJ45 – pin to pin For communication between eStore and eCore
eStore MPC01 BUS cable For communication between eStore and MPC01
eStore MCA BUS cable For communication between eStore and MCA chargers, when not using MPC01
Replacement fuse (250 A) Littelfuse Mega series, hole distance 50.8mm
eStore mounting bracket kit – vertical For mounting eStore in vertical position
eStore mounting bracket kit – horizontal For mounting eStore in horizontal position

eStore serves as a voltage source of 12 V in power systems for caravans, campers, commercial vehicles and stationary applications. eStore may not be used for medical purposes.
In conjunction with an inverter, such as Dometic eCore, devices with 230 Vw can be supplied.
Use as a starter battery is not possible. eStore must not be directly connected to the starter battery to support engine starting. Up to eight eStore can be connected in parallel to increase the total installed capacity up to 800 Ah.
eStore can be transported with the built-in handles.
eStore Intended use

eStore is a maintenance-free lithium-ion battery for 12 Vg systems for power supply. It has an internal main switch and an internal 250 A fuse.
In conjunction with a battery management system eStore provides the following functions:
Battery cell temperature monitoring due to integrated temperature sensor
Communication between multiple eStore batteries
eStore can be used with Dometic eCore or Waeco PerfectCharge MCA series chargers. Use of a third party charger is also permitted. To ensure the internal main switch remains closed when charging under normal conditions, the charger should have the following specification:
To increase the total installed capacity, up to 8 eStores can be connected in parallel. The maximum combined output current must not exceed 250 A. I
A single eStore can provide current of 250 A for a short time. The continuous current should not exceed 200 A. Continuous dis- charge current exceeding 200 A from a single eStore can lead to a shorter lifetime. Use two or more eStores when current of more than 200 A is required continuously.
Technical description eStore · Battery cell monitoring · Battery voltage monitoring

Pos. in fig. 1,
1 Main Switch Command activates (closes) and disactivates (opens) the internal main switch
flashes green: the battery management system is active, the main switch is activated or turned on (closed)
flashes yellow: the battery management system is active, the main switch is disactivated or turned off (open)
4 LIN interface for connection to Waeco PerfectCharge MCA chargers and Dometic MPC01
5 USB interface for eStore configuration
Pos. in fig. 2,
1 Negative pole M8 terminal for chargers and consumer
2 Internal fuse 250 A – mounting hole center distance 50.8 mm
3 Positive pole M8 terminal for chargers and consumer

Observe the following instructions on installation location
eStore can be installed vertically (fig. a, page 6) or horizontally (fig. b,
page 7), on a flat and stable surface.
eStore must not be installed close to combustible materials.
The installation location should be protected from moisture and dust.
Leave at least 2 cm of space around eStore and ensure good ventilation.
The installation should avoid low temperatures during winter operation (charging) to ensure continuous operation. Avoid low temperatures during winter operation.
For safety reasons, note the location of existing wiring harnesses, wires
and other components within the installation area, in particular those which are not visible, when installing the eStore (when drilling or screwing etc.).
If you install more than one eStore, leave at least 1 cm of space between
the eStores.
➤Select a suitable location and secure eStore safely.
(fig. a, page 6). Suitable mounting brackets are available as accessories (see chapter “Accessories” on page 12).
the device (fig. b, page 7). Pass them between the handles and mount- ing feet and fix them to the mounting surface. This will ensure the eStore does not move when the vehicle is in motion. Suitable mounting brackets are available as accessories (see chapter “Accessories” on page 12).
Attaching eStore eStore

➤Release the closure by gently pushing down the pin in the middle of the
closure (fig. 3 1, page 3).
Take care not to push it through completely.
➤Open the cover (fig. 3 2, page 3).
➤Remove the unlocked closure (fig. 3 3, page 3).
➤Note the positions of the closure (fig. 4 , page 4):
➤Slide back the pin of the closure.
➤Put in the ready (armed) closure (fig. 5 1, page 4).
➤Close the cover(fig. 5 2, page 4).
➤Lock the closure by gently pushing down the pin in the middle of the
closure (fig. 5 3, page 4).
Take care not to push it through completely.
➤Open the cover of the pole (see chapter “Opening the cover of the pole”
on page 17).
➤Connect positive pole (fig. 2 1, page 3) and negative pole (fig. 2 2,
page 3) with a low output current, 12 Vg battery or charger.
✓The Status LED (fig. 1 2, page 3) flashes yellow.
✓eStore ist activated.
eStore Connecting eStore

to eStore. Please refer to the respective manual. Make sure that the devices you want to connect are turned off.
➤Turn off (open) the main switch of eStore one by pressing the main switch
command (fig. 1 1, page 3).
➤Open the cover (see chapter “Opening the cover of the pole” on page 17) .
➤Connect the positive cable to the positive pole (fig. 2 3, page 3).
➤Tighten the terminal screw with a tightening torque of 13 to 15 Nm.
➤Close the cover (see chapter “Closing the cover of the pole” on page 17.
➤Open the cover of the negative pole (see chapter “Opening the cover of
the pole” on page 17) .
➤Connect the negative cable to the negative pole (fig. 2 1, page 3).
➤Tighten the terminal screw with a tightening torque of 13 to 15 Nm.
➤Close the cover of the negative pole (see chapter “Closing the cover of
the pole” on page 17).
➤Turn on (close) the main switch of the eStore by pressing the main switch
command (fig. 1 1, page 3).
➤Turn off all devices, especially those that are connected with eStore.
➤Turn off (open) the main switch of eStore one by pressing the main switch
command (fig. 1 1, page 3).
➤Connect the 12 Vg device to eStore.
➤Turn on (close) the main switch of the eStore by pressing the main switch
command (fig. 1 1, page 3).
➤Turn on the 12 Vg device.
Connecting eStore eStore

You can connect eStore for data communication as follows:
to Dometic eCore via the CAN bus
to Waeco PerfectCharge MCA charger via LIN/CI bus
to Waeco PerfectCharge MCA charger via LIN/CI bus, through Dometic
Through the data link parameters such as voltage, temperature and charge level are monitored and displayed. For more details, please refer to the rele- vant operating instructions of the connected devices.
➤Establish a data connection corresponding to your system configuration.
Up to eight eStore can be connected in parallel to increase the total battery pack capacity to up to 800 Ah. The figure shows an example of the data con- nections for three connected eStores (fig. 6, page 4). I
and the eStore configuration kit (see chapter “Accessories” on page 12). Connected eStores must be set with the eStore Configurator
(see chapter “Connect BUS cable and configure” on page 20). If you only use a single eStore, no configuration is required. eStore is factory-adjusted to be used as a single battery. Make sure that all eStores are fully charged.
The first eStore serves as the master. It has the following functions:
It controls the main switch of the other eStores (fig. 6, page 4).
It connects to the chargers via data links (CAN/LIN).
The other eStores are controlled as slaves by the master.
eStore Connecting eStore

Connect BUS cable and configure
For configuration you need a PC with a USB port and the eStore configurator.
Depending on the installation situation it may be useful to configure and tag each eStore before installation into the vehicle.
➤Make sure that eStore is not in storage mode (status LED is blinking).
➤Plug the USB cable from the PC into the USB port (fig. 1 5, page 3) of
the first (master) eStore.
➤Configure the master, see chapter “Configuring connected eStores” on
page 20.
➤Attach the ID label (fig. 6 6, page 4) on the master (fig. 6 1, page 4).
➤Disconnect the USB cable from the master.
➤Plug the USB cable from the PC to the USB port of the first slave.
➤Attach the ID label (fig. 6 3, page 4) on the slave (fig. 6 2, page 4).
➤Configure the remaining slaves, if necessary.
➤Connect the eStores with the BUS cables (fig. 6 4, page 4).
➤If necessary, install the ModbusReader “mbreader_setup.exe” from the
data CD to your PC.
➤Copy the file “eStore_Configuration_utility_FM739.mbc ” of the data CD
to the hard disk of the PC .
➤Open the file “eStore_Configuration_utility_FM739.mbc”.
✓The eStore configurator opens (fig. 7, page 5).
➤Press CTRL + F or select in the menu “Connection” the command Find
COM (fig. 8 1, page 5).
➤Select the new port number, in the example COM18 ( fig. 8 2, page 5).
➤Press CTRL + P or select in the menu “Connection” COM Parameters
(fig. 8 3, page 5).
➤The window COM Settings opens.
➤Choose from the list Parity (fig. 8 4, page 5) the value Even.
➤Click OK (fig. 8 5, page 5).
Connecting eStore eStore

➤Enter in the field Pack Address the number of the eStore , e.g. “1” for the
master (fig. 9 1, page 5).
➤Press “F2” or select in the menu “Connection” the command Connect
(fig. 8 6, page 5).
➤Press the enter key.
➤Enter in the field Total Pack Number the number of all eStores you want
to connect , e.g. “3” if you want to connect three eStores (fig. 9 2, page 5).
➤Press the enter key.
➤Enter in the field Parallel Pack Number the number of all eStores you
want to connect , e.g. “3” if you want to connect three eStores (fig. 9 3, page 5).
➤Press the enter key.
➤Enter the password 3331 (fig. 9 4, page 5).
➤Press the enter key.
➤Attach the ID label (fig. 9 5, page 5).
eStore Connecting eStore

Before initial use eStore
opens (see chapter “Operating voltages and main switch” on page 23). Avoid storing or operating eStore at extremely high or low
temperatures. Avoid continuously high discharge (> 200 A).

The eStore Battery Management System (BMS) assesses the state of each cell in the battery, deciding when to protect the battery by opening the main switch.
The Main Switch works as follows:
eStore state Main Switch behavior
Discharging < 30 A, 11 – 12 V: main switch opens > 30 A, 10 – 11.8 V: main switch opens These are indicative values and are given as guidance only. The main switch opening voltage depends on internal parameters such as cell voltage and temperature, and discharge current. The indicated current values are valid per single eStore.
Charging The main switch opening voltage depends on internal parameters such as cell voltage and temperature, and charge current. The maximum voltage above which the main switch opens is 15.2 V. Charging with the recommended charging parameters will ensure the main switch remains closed during normal operation. See chapter “Charging eStore” on page 23 for recommended charging parameters.
NOTICE! eStore can be charged with Dometic eCore or Waeco PerfectCharge MCA series chargers (choose power mode; see charger manual for appropriate DIP switch setting). Use of third party chargers is permitted. The main switch will remain closed when charging under normal conditions if the following charger parameters are met: end of charge voltage: between 13.8 V and 14.0 V maximum output 40 A (30 A recommend) per installed eStore For further information please contact Dometic (see addresses on the back page).
eStore Using eStore

Proceed as follows to replace the fuse:
➤Open the cover of the positive pole (see chapter “Opening the cover of the
pole” on page 17) .
➤Remove the nuts and washers from the fuse (fig. 0 1, page 6).
➤Replace the fuse (fig. 0 2, page 6).
➤Fix the new fuse with the nuts and washers (fig. 0 1, page 6). Tighten
the nuts between 13 and 15 Nm.
➤Close the cover of the positive pole (see chapter “Closing the cover of the
pole” on page 17).
the service life. Recharge eStore every 3 months. For long storage (e.g. RV winter break):
– remove all loads – charge eStore – open the main switch
This will avoid over discharge and potential damage to eStore.
➤Occasionally clean the product with a damp cloth.
Cleaning eStore eStore

No voltage at the battery terminals.
The main switch is turned off (open).
➤Turn on (close) the main
switch.
The fuse is defective. ➤Replace the fuse (see chap-
ter “Changing the fuse” on page 24).
eStore is in storage mode. ➤Activate eStore.
eStore is not configured correctly.
➤Configure eStore.
eStore is over discharged. ➤Charge eStore with a charg-
ing current of < 10 A. Note: Do not use intelligent charging systems (with main swtich open, the eStore ter- minals have no voltage. Some intelligent battery chargers do not start if no voltage is present). ➤Contact an authorised work-
shop.
eStore is defective. ➤Contact an authorised work-
shop.
Status LED does not flash.
eStore is in storage mode. ➤Activate eStore.
eStore is severely over discharged.
➤Charge eStore with a charg-
ing current of < 10 A. Note: Do not use intelligent charging systems (with main swtich open, the eStore ter- minals have no voltage. Some intelligent battery chargers do not start if no voltage is present). ➤Contact an authorised work-
shop.
eStore is defective. ➤Contact an authorised work-
shop.
eStore Troubleshooting · Problem Cause Remedy

Status LED flashes red.
eStore is configured to be con- nected to multiple eStores and BUS cables are not plugged in.
➤Plug in eStore cables.
eStore is over discharged. ➤Charge eStore.
eStore is over charged ➤Disconnect chargers from
eStore. ➤Check the charging voltage
of battery chargers.
eStore ist defective. ➤Contact an authorised work-
shop.
eStore does not respond to pressing of the main switch command.
eStore is in storage mode. ➤Activate eStore.
eStore is over discharged. ➤Charge eStore with a charg-
ing current of < 10 A. Note: Do not use intelligent charging systems (with main swtich open, the eStore ter- minals have no voltage. Some intelligent battery chargers do not start if no voltage is present). ➤Contact an authorised work-
shop.
eStore is configured as slave and not as master.
➤Use main switch command
on master eStore (eStore configured #1)
Configuration for connecting multiple eStores is faulty.
➤Check the configuration.
eStore is defective. ➤Contact an authorised work-
shop.
Troubleshooting eStore · Problem Cause Remedy

Main switch turns on (closes) but turns off (opens) again immedi- ately.
eStore is over discharged. ➤Charge eStore.
eStore is over charged ➤Disconnect chargers from
eStore. ➤Check the charging voltage
of battery chargers.
Charge current is too high. ➤Reduce charge current .
Discharge current is too high. ➤Reduce the load. ➤Check the temperature of the
eStore. ➤Charge eStore.
eStore is defective. ➤Contact an authorised work-
shop.
“Warning eStore” appears on eCore control panel.
eStore temperature is too low for charging.
➤Check charger status LED. ➤Check eStore Temperature. ➤Heat eStore storage area.
eStore temperature is too high for charging.
➤Check charger status LED. ➤Check eStore Temperature. ➤Heat eStore storage area.
eStore Troubleshooting · Problem Cause Remedy

The statutory warranty period applies. If the product is defective, please contact the manufacturer's branch in your country (see the back of the instruction manual for the addresses) or your retailer.
For repair and guarantee processing, please include the following docu- ments when you send in the device:
A copy of the receipt with purchasing date
A reason for the claim or description of the fault
➤Place the packaging material in the appropriate recycling waste bins
If you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations. B
Protect the environment! Do not dispose of any batteries with general household waste. Return defective or used batteries to your retailer or dispose of them at collection points.
Warranty eStore

Item No.: 9102900224
Operating temperature range (for discharging):
–30 °C (with reduced performance) to
Temperature range for charging with Dometic eCore: with other chargers:
–10 °C to +55 °C
0 °C to +40 °C
Dimensions L x W x H: 315 x 160 x 285 mm
Inspection/Certification:
UN 38.3 UN 3480
eStore Technical data