Installation
Install the continuous-flow heater as described in the illustrated section. Observe the instructions in the text.
Unpack the appliance and check for transport-related ■
damage.
Please dispose of the packaging, and if applicable, the old ■
appliance in an environmentally-friendly manner.
Risk of electric shock! Switch off the mains voltage supply immediately if a fault occurs.
We do not accept liability for damage resulting from ■
failure to heed these instructions.
The continuous-flow heater may only be connected ■
Shut off water supply. The electrical connection (connec- ■
and put into operation by a qualified professional.
tion cable) must be disconnected from the power supply. Unscrew the fuse or switch off the circuit breaker.
Never open the appliance without disconnecting the ■
power supply beforehand.
The statutory regulations of the respective country, as ■
The continuous-flow heater must be mounted on the ■
well as those of the local electricity and water suppliers, must be adhered to.
wall. Attach it if necessary on the lower adjustable screws.
The distance to the wall is variable. You can compensate ■
The continuous-flow heater is a Class ■ I appliance and must be connected to the protective earth.
for any unevenness of the wall's surface.
The grommet must tightly surround the connection cable. ■
The appliance must be permanently connected to in- ■
If it is damaged during mounting, the openings must be provided with watertight sealing.
stalled pipes. The conductor cross-section must comply with the installed appliance power.
The continuous-flow heater must be vented. The ■
To guarantee compliance to relevant safety regulations, ■
warm water tap must be opened and the appliance must be flushed out thoroughly for 1 minute with at least 6 litres of water.
an all-pole separator must be fitted during installation. The contact opening must be at least 3 mm.
The continuous-flow heater is only suitable for closed ■
(pressurized) operation.
The tap and outlet fittings must be approved for operation ■
The electrical supply terminal can be fitted at the top or ■
bottom. The sheath of the connection cable must extend for at least 40 mm into the appliance.
with closed (pressurized) continuous-flow heater systems.
The continuous-flow heater can be operated with cold or ■
pre-warmed water (for example, from a solar energy unit water supply). Observe the technical data and the special accessories for this purpose.
Only connect the continuous-flow heater to a cold water ■
Switch on the fuses. ■
line.
Setting the temperature. ■
The continuous-flow heater may only be installed in a ■
frost-free room.
to flow for at least 1 minute (flow-rate at least 6 litres per minute). Only then (for safety reasons) will the appliance begin to heat.
Disconnect the electrical connection cable from the ■
supply and shut off the water supply before connect- ing the appliance!
Connect the water supply and then connect the elec- ■
trical supply.
Only make the openings which are required for instal- ■
lation on the rear of the appliance. If the appliance is reinstalled, the unused openings must be provided with watertight sealing.
Remove the flow-rate limiter (see Fig. A) with low water ■
pressure.
Explain the operation of the continuous-flow heater to ■
Do not touch electrically live parts after installation. ■
the user.
First start-up

A If the continuous-flow heater does not have sufficient water flow due to low water line pressure in your do- mestic plumbing system, remove the flow-rate limiter.
D Status display on the appliance

B Priority circuit for the combination with electrical storage heaters: For operation with a priority circuit, a special load shedding relay BZ 45L20 (special accessory) is re- quired. Other existing load shedding relays, with the exception of electronic load shedding relays, may malfunction.
Fast flash (4/s) Desired water temperature is not reached (water flow too high for appliance rating).
C The control electronics must be coded when operated with a load shedding relay.
E The filter upstream from the check valve in the cold water supply inlet is clogged. Remove the filter and either clean it or descale it. See Figure E 1–3.

Minimum conductor cross-section [mm2] 4 4 6
12 °C to 38 °C [l/min] 9.9 11.6 13.6
12 °C to 60 °C [l/min] 5.4 6.3 7.2
Start-up flow pressure * [MPa (bar)] 0.025 (0.25) 0.025 (0.25) 0.025 (0.25)
Application area in water specific electric resistance at 15 °C [Ωcm] ≥ 1 300 ≥ 1 300 ≥ 1 300
Rated pressure [MPa (bar)] 1.0 (10.0) 1.0 (10.0) 1.0 (10.0)
Maximum mains impedance at connection point [Ω] ≤ 0.400 ≤ 0.400 ≤ 0.400
* The pressure loss on the mixer must also be added.

a priority circuit

With the use of a thermostat battery, the following settings are recommended for high temperatures or large quantities of water, for example:
Please read the operating instructions carefully before you use the appliance!

This appliance is intended for domestic use or for house- ■
hold-based non-commercial applications. Household- based applications include, e.g. usage in employees catering facilities for shops, offices, agricultural and other commercial operations, as well as usage by guests of guest houses, small hotels and similar residential establishments.
Risk of electric shock! Switch off the mains voltage supply immediately if a fault occurs.
Turn on the hot-water tap. ■
The continuous-flow heater switches on and heats the water when the hot-water tap is turned on.
We do not accept liability for damage resulting from ■
failure to heed these instructions.
It switches off again when the tap is turned off. Changing the supply water temperature correspondingly changes the outgoing water temperature.
The continuous-flow heater may only be connected ■
and put into operation by a qualified professional.
Repairs may only be undertaken by a suitably qualified ■

specialist to avoid potential sources of danger.
The continuous-flow heater may only be installed in a ■
frost-free room.
Persons (including children) with diminished bodily, sen- ■
sory or mental perception, or those who lack knowledge or experience should not operate the appliance, unless they are monitored or have received instruction concern- ing use of the appliance by persons responsible for their safety.

Keep children away from the appliance. Please moni- ■
tor children to ensure that they do not play with the appliance.
If a higher temperature for a completely opened warm water tap is not achieved, more water flows than the flow-through heater can warm as a result its performance capabilities. In this case, the warm water tap must be closed somewhat.
The mixer and the warm water pipe may be hot . ■
Please switch off all fuses immediately if a malfunction ■
occurs. Immediately shut off the cold water supply to the appliance should it leak. The malfunction can only be re- paired by a specialist or an authorised service agent.
The electronically regulated flow-through heater warms the water while it flows through the unit.
The warm water temperature can be continuously adjusted on the electronically regulated flow-through heater:
Switch off the appliance (unscrew the fuse in the house ■
Turn on the hot-water tap until the air is purged from the ■

Cleaning
Set the desired warm water temperature directly on the ■
Simply wipe the appliance with a damp cloth.
flow-through heater.
Do not use intensive or abrasive cleaning agents.
Mixing with cold water at the armature for water that is too hot consumes unnecessarily water and energy.
At approx. 40 °C (temperature selection position ) the unit operates most economically.
If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you can remedy the fault yourself by using the following guidelines. You will save yourself the costs of an unnecessary visit by customer service personnel.
Fault Cause Solution Who
Water flow-rate is too low. The filter in either the water tap or the showerhead is clogged
Remove the filter and either clean it or descale it.
The filter in the corner regulating valve is clogged.
Get a servicing expert to clean the filter.
The filter upstream from the check valve in the cold water supply inlet is clogged.
Remove the filter and either clean it or descale it.
The desired water temperature is not reached.
The continuous-flow heater is connected to a thermostatically- controlled water tap.
Set the temperature on the continu- ous-flow heater to “max”.
The power limit has been reached. Water flow-rate is too high and/or the cold water supply temperature is too low.
Reduce the flow-rate at the water tap supply.
By a qualified professional: use the angle valve to regulate the flow-rate. Check the flow-rate limiter or re- place it with a smaller one.
The water is not sufficiently warm. The fuse in the house electrical in- stallation has tripped/blown.
Check the fuse in the house electri- cal installation.
The appliance‘s automatic circuit breaker has been tripped.
Get the appliance‘s automatic cir- cuit breaker checked by an electri- cian. Check the permissible supply temperature.
The power limit has been reached. Water flow-rate is too high and/or the cold water supply temperature is too low.
By a qualified professional: use the angle valve to regulate the flow-rate. Check the flow-rate limiter or re- place it with a smaller one.
From time to time, cold water flows out.
The air sensor in the appliance de- tects air in the water and momen- tarily switches the heating element off.
After a few seconds, the continu- ous-flow heater automatically goes back into operation.
Continu- ous-flow heater au- tomatically resolves problem
Winter operation: The desired water temperature leaving the tap is no longer reached.
The supply temperature has reduced.
Reduce the water flow on the taps until the desired water temperature is reached.

Fault Cause Solution Who
The appliance does not start (heat), no water flows.
Power failure or initial start-up. Starts rinsing: Open the warm water tap and allow water to flow for at least 1 minute (flow-rate at least 6 litres per minute). Only then (for safety reasons) will the appliance begin to heat.
Should the appliance not start because of a reduced flow-rate, remove the perlator, shower head or similar before start and repeat the process.
If the fault could not be eliminated, please call customer service.
We ask you to always provide the E-No. and the FD-No. of your appliance when calling in a customer service engineer.
E-No.:
FD-No.:
This appliance is labelled in accordance with Euro- pean Directive 2002/96/EG concerning used elec- trical and electronic appliances (waste electrical and electronic equipment – WEEE).
The guideline determines the framework for the return and recycling of used appliances as applica- ble throughout the EU.
Please ask your specialist retailer about current dis- posal facilities.
The guarantee conditions for this appliance are as defined by our representative in the country in which it is sold.
Details regarding these conditions can be obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be produced when making any claim under the terms of this guarantee.
Subject to change without notice.
Customer


Häufige Probleme, wahrscheinliche Ursachen und Lösungen.
| Problem | Mögliche Ursache | Abhilfe | |
|---|---|---|---|
| Water flow-rate is too low. | The filter in either the water tap or the showerhead is clogged | Remove the filter and either clean it or descale it. | p.4 |
| Water flow-rate is too low. | The filter in the corner regulating valve is clogged. | Get a servicing expert to clean the filter. | p.4 |
| Water flow-rate is too low. | The filter upstream from the check valve in the cold water supply inlet is clogged. | Remove the filter and either clean it or descale it. | p.4 |
| The desired water temperature is not reached. | The continuous-flow heater is connected to a thermostatically- controlled water tap. | Set the temperature on the continu- ous-flow heater to “max”. | p.4 |
| The desired water temperature is not reached. | The power limit has been reached. Water flow-rate is too high and/or the cold water supply temperature is too low. | Reduce the flow-rate at the water tap supply. | p.4 |
| The desired water temperature is not reached. | By a qualified professional: use the angle valve to regulate the flow-rate. Check the flow-rate limiter or re- place it with a smaller one. | p.4 | |
| The water is not sufficiently warm. | The fuse in the house electrical in- stallation has tripped/blown. | Check the fuse in the house electri- cal installation. | p.4 |
| The water is not sufficiently warm. | The appliance‘s automatic circuit breaker has been tripped. | Get the appliance‘s automatic cir- cuit breaker checked by an electri- cian. Check the permissible supply temperature. | p.4 |
| The water is not sufficiently warm. | The power limit has been reached. Water flow-rate is too high and/or the cold water supply temperature is too low. | By a qualified professional: use the angle valve to regulate the flow-rate. Check the flow-rate limiter or re- place it with a smaller one. | p.4 |
| From time to time, cold water flows out. | The air sensor in the appliance de- tects air in the water and momen- tarily switches the heating element off. | After a few seconds, the continu- ous-flow heater automatically goes back into operation. | p.4 |
| Winter operation: The desired water temperature leaving the tap is no longer reached. | The supply temperature has reduced. | Reduce the water flow on the taps until the desired water temperature is reached. | p.4 |
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.