Benutzeranleitung / Produktwartung IC107A-R3 des Produzenten Black Box
Zur Seite of 20
CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500 ) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation , 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.
1 FCC/IC RFI ST A TEMENTS, DECLARA TION OF CONFORMITY FEDERAL COMMUNICA TIONS COMMISSION AND INDUSTR Y CANADA RADIO-FREQUENCY INTERFERENCE ST A TEMENTS This equipment generates, uses, and can radiate .
2 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY ST A TEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
3 NOM ST A TEMENT , TRADEMARKS 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados.
4 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) Contents Chapter Page 1. Specifications ............................................................................................. 5 2. Introduction .................................................
5 CHAPTER 1: Specifications 1. Specifications Compliance: CE; FCC Part 15 Subpart B Class A, IC Class/classe A Interfaces: EIA/TIA RS-232, DTE or DCE (user-selectable); EIA/TIA RS-422/485 Protocol: As.
6 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) Temperature Tolerance: Operating: 32 to 122˚F (0 to 50˚C) Storage: –4 to +158˚F (–20 to +70˚C) Humidity Tolerance: Up to 95% noncondensing MTB.
7 CHAPTER 2: Introduction 2. Introduction The RS-232 ↔ RS-422/485 Converter (Data Only) allows your RS-232 and RS-422/485 equipment to communicate with each other. It operates in full-duplex mode over 4-wire lines. A four-wire terminal block on the RS-422/485 port makes installation easy.
8 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) 3. Configuration Here’s how to configure the RS-232 ↔ RS-422/485 Converter (Data Only) for your application (refer to Figure 3-1 on the next page .
9 CHAPTER 3: Configuration 5. Normally, the Converter’s frame ground is isolated from its RS-232 signal ground. But if you want to connect frame ground to signal ground, you’ll need to solder a 100-ohm, 500-mW resistor to the terminals of location W7.
10 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) 4. Installation To install your RS-232 ↔ RS-422/485 Converter (Data Only) system, take these steps, making sure that the Converter and your devices are powered OFF: 1. Run an RS-232 cable from your RS-232 device to the Converter’s DB25 female RS-232 port.
11 CHAPTER 5: Operation 5. Operation 5.1 RS-232 Circuitry The RS-232 side of the RS-232 ↔ RS-422/485 Converter (Data Only) is composed of the RS-232 drivers and receivers, the delay circuitry, and other circuitry necessary to operate the RS-232 control lines.
12 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) Figure 5-1. Block diagram of Converter functions in DCE mode. Figure 5-2. Block diagram of Converter functions in DTE mode.
13 CHAPTER 5: Operation 5.2 RS-422/485 Circuitry The RS-422/485 side of the Converter is made up of the driver, receiver, and line- termination networks. As described in Chapter 3 , you can use switch S2 to either connect the receiver’s termination network to the line (terminate the RS-422/485 port) or leave it unconnected (unterminated).
14 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) 6. T roubleshooting 6.1 Calling Black Box If you determine that your RS-232 ↔ RS-422/485 Converter (Data Only) is malfunctioning, do not attempt to alter or repair the unit . It has no user-serviceable components.
15 APPENDIX: Pinouts Appendix: Pinouts T able A-1. Pinning of the RS-232 connector (DB25 female). Pin Number and Signal Function Pin1 — Frame Ground Connects the Converter’s frame ground to the frame ground of the RS-232 device.
16 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) T able A-2. Pinning of the RS-422/485 connector (4-position ter minal block). Pin/Signal Function TXA and TXB Data received by the Converter from the RS-232 port is transmitted out of the unit over twisted-pair wires using these two outputs.
NOTES.
NOTES.
1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746 © Copyright 2001. Black Box Corporation. All rights reserved..
Ein wichtiger Punkt beim Kauf des Geräts Black Box IC107A-R3 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Black Box IC107A-R3 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Black Box IC107A-R3 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Black Box IC107A-R3 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Black Box IC107A-R3 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Black Box IC107A-R3 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Black Box IC107A-R3 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Black Box IC107A-R3. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Black Box IC107A-R3 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.