DE
Cresta logo
Offizielle Bedienungsanleitung

Cresta BPM620

56 Seiten·2.7 MB·Blutdruckmessgerät·PDF·ENITJA
Cresta BPM620
Inhaltsverzeichnis 29 Abschnitte TABLE OF CONTENTS · INTRODUCTION · NOTES ON SAFETY · ABOUT BLOOD PRESSURE · … AnzeigenAusblenden
Page 1 of the Cresta BPM620 user manual
Seite 1 · Zum Vergrößern klicken
Seite 1

We thank you for buying our CRESTA electronic upper arm Blood Pressure Monitor BPM 620. It shows your confidence in our brand and our products. Please be assured you have bought a high quality product which you will enjoy using for many years to come. If you require technical support and or have questions about the functioning of the

product, please contact our After Sales Service

+ 31 900 4000030

Read this manual thoroughly before your first use, even if you are familiar with this type of product. It provides you with tips to make optimal use of this product. Keep the manual in a safe place for future reference, along with the warranty card, purchase receipt and carton.

Page 3 of the Cresta BPM620 user manual — Examples of signs
Seite 3 · Zum Vergrößern klicken
Seite 3

INTRODUCTION

This Blood pressure monitor uses the oscillometric method of blood pressure

measurement. The blood pressure monitor is intended for use by medical professionals

or at home to monitor and display the diastolic, the systolic blood pressure and the

pulse rate of an adult, with an arm cuff around the left upper arm according to the

instruction in “ATTACHING THE ARM CUFF “. The expected lifetime of the product is

over 5 years. The product complies with the electromagnetic compatibility

requirement of EN60601-1-2, safety standards of EN60601-1 and performance of IEC

80601-2-30 as specified in EEC directive 93/42/EEC. NOTES ON SAFETY

The warning signs and sample icons shown here are listed for your safe and

correct use of the unit, so as to prevent injuries or damages to the device.

The icons and meanings are as follow.

Examples of signs

indicates prohibitions - what you should not do. Matters involving

actual prohibitions are indicated by text or pictures in or near

. The left icon

refers to “general prohibitions”.

indicates something that is compulsory - what must always be

observed. Matters involving actual compulsory actions are indicated by text or

pictures in or near

. The left icon refers to “general compulsions”.

indicates something can’t be disassembled or do not disassemble

Matters involving actual compulsory actions are indicated by text or pictures in or

.The left icon refers to “General prohibitions”.

Show 4 more labels / short text on this page
The icon · The icon · The icon · near
Page 4 of the Cresta BPM620 user manual — Attention and read before use
Seite 4 · Zum Vergrößern klicken
Seite 4

Type BF Applied part

Attention and read before use

Marking of electrical and electronic

equipment in accordance with Article

11(2) of Directive 2002/96/EC (WEEE)

Warning

The patient should follow the doctor’s instructions and should not perform

self-judgment and self-treatment by the measuring result. Self-diagnosis of measured

results and treatment are dangerous. The device should not be used to judge illness,

first aid and continuously monitor measuring.

This device cannot be used during Patient transport and surgical care. It can be used

in households or fixed places only.

Please press the “ON/OFF” button to stop the operation when you feel uncomfortable

with the arm, or if the air is inflating abnormally without stop.

Do not let a child below 12 years old and people who can’t express one’s intention

use this appliance. When it is used by children of 12~18 years old, they should be

supervised by an adult. This may cause an accident or trouble.

Do not use the unit for another purpose than measuring blood pressure.

This may cause an accident or trouble.

Please do not use a mobile phone around the device. Please do not use the device

around the magnetic field.

Do not disassemble, repair, or remodel the main unit or the cuff of the blood pressure

monitor. This will cause the unit not to function or to function erroneously.

Page 5 of the Cresta BPM620 user manual — +31 900-4000030 ABOUT BLOOD PRESSURE
Seite 5 · Zum Vergrößern klicken
Seite 5

TIPS FOR OPTIMAL USE

Make sure there is no kink in the connection tube before you start measuring to

avoid any injury to the patient.

For any patient, do not measure more than 3 times continuously, it should be

at least above 5 minutes of interval rest between any two measurements,

otherwise will cause extravasated blood.

Do not measure your blood pressure over 6 times each day.

Do not apply the cuff over a wound as this can cause further injury.

Do measure on the arm which is on the side of a mastectomy, otherwise it

could cause injury.

Observe the air pressure value from the LCD display.

When measuring, it should not exceed 299 mmHg, otherwise press the “ON/OFF”

button to stop the measurement.

Do not use force to bend the arm cuff or the air tube.

Do not knock or drop the main unit.

Always use the specified accessories in the manual, the use of other parts not

approved by the manufacturer may cause faults or injuries.

For service information, parts list etc., please contact our service department

+31 900-4000030 ABOUT BLOOD PRESSURE

What is blood pressure?

Blood pressure is the force exerted by the blood against the walls of the arteries. The

Systolic pressure occurs when the heart contracts. The Diastolic pressure occurs when

the heart expands and refills. Blood pressure is measured in millimeters of mercury

(mmHg). One's natural blood pressure is represented by the fundamental pressure,

which is measured first thing in the morning while one is still at rest and before eating.

What is hypertension and how is it controlled?

Hypertension, an abnormal high arterial blood pressure, if left unattended, can cause

Page 6 of the Cresta BPM620 user manual — TIPS FOR OPTIMAL USE
Seite 6 · Zum Vergrößern klicken
Seite 6

many health problems including a stroke and a heart attack. Hypertension can be

controlled by altering your lifestyle, avoiding stress and with medication under a

doctor's supervision. To prevent hypertension or keep it under control: Do not smoke,

exercise regularly, reduce salt and fat intake, have regular physical checkups and

maintain a proper weight and control this.

Why measure blood pressure at home?

Blood pressure measured at a clinic or doctor's office may cause apprehension and

produce an elevated reading, 25 to 30 mmHg higher than that measured at home,

Home measurement reduces the effects of outside influences on blood pressure

readings, supplements the doctor's readings and provides a more accurate,

complete blood pressure history.

WHO blood pressure classification

Standards for assessment of high blood pressure, without regard to age, have

been established by the World Health Organization (WHO), and shown in chart below.

Cresta BPM620 — TIPS FOR OPTIMAL USE diagram (page 6)
Abb. 1

An individual's blood pressure varies greatly on a daily and seasonal basis.

It may vary by 30 to 50 mmHg due to various conditions during the day. In

hypertensive individuals, variations are even more pronounced.

Normally, the blood pressure rises while at work or play and falls to its lowest levels

during the sleep. So, do not be overly concerned by the results of one measurement.

Take measurements at the same time every day using the procedure described in this

manual and know your normal blood pressure. Many readings give a more

comprehensive blood pressure history.

Be sure to note date and time when recording your blood pressure. Consult your

doctor to interpret your blood pressure data.

Blood pressure variations

Page 7 of the Cresta BPM620 user manual — PARTS IDENTIFICATION
Seite 7 · Zum Vergrößern klicken
Seite 7

PRECAUTIONS BEFORE USE

1. If you are taking medication, consult with your doctor to determine the most

appropriate time to measure your blood pressure. NEVER change a prescribed

medication without first consulting with your doctor.

2. For people with an irregular or unstable peripheral circulation problems due to

diabetes, liver disease, hardening of the arteries, etc., there may be

fluctuation in blood pressure values measured at the upper arm versus at the

wrist.

3. Measurements may be impaired if this device is used near televisions,

microwave ovens, X-ray equipment, mobile phone equipment or other

devices with strong electrical fields. To prevent such interference, use the

monitor at a sufficient distance from such devices or turn them off.

4. Before using, wash your hands.
5. Do not measure on the arm which simultaneously used monitoring ME

Equipment, otherwise it could cause loss of function.

6. Consult your doctor if unexpected readings are obtained, also please refer to

“Trouble shooting” of the manual.

7. The reading is probably a little lower than measured in the hospital due to the

steady mood at home.

8. Cuff pressure range 0-299mmHg

FEATURES OF THE PRODUCT

  • Memory can store 90 measurements.
  • Large and clear LCD display.
  • WHO blood pressure classification display.
  • Easy to use, press one button to automatically measure, record the

measurement values and measurement time.

  • Automatically turns off (within 1 minute) to save power.

PARTS IDENTIFICATION

Cresta BPM620 — PARTS IDENTIFICATION diagram (page 7)
Abb. 2
Cresta BPM620 — PARTS IDENTIFICATION diagram (page 7)
Abb. 3
ComponentAccessory :

Storage case

Page 8 of the Cresta BPM620 user manual — CAUTION
Seite 8 · Zum Vergrößern klicken
Seite 8

INSERT OR REPLACE BATTERIES

  • Remove the battery cover.
  • Insert new batteries as indicated in the battery compartment, taking care that

the polarities (+) and (-) are correct.

  • Close the battery cover. Use only LR6, AA batteries.

Dispose of empty batteries to the authorized collecting party subject to the

regulation of each individual territory.

CAUTION

Insert the batteries as shown in the battery compartment. If not, the device will not

work. When

- LOW BATTERY mark - blinks in the display, replace all batteries with

new ones. Do not mix old and new batteries. It may shorten the battery life, or cause

the device to malfunction. LOW BATTERY mark

does not appear when the

batteries run out. Please ensure to distinguish the positive polar "+” and the negative

polar “-" of the batteries when replacing the batteries. Batteries, which have fluid on

the surface or which are modified, cannot be inserted into the product. Battery short

circuit must be prevented. Battery life varies with the ambient temperature and may

be shortened at low temperatures. The batteries may leak and cause a malfunction.

Use the specified batteries only. The batteries provided with the device are for testing

the monitor’s performance and may have a shorter life.

Used batteries may leak and damage the main unit. lf you are not going to use the

unit for a long period of time (approximately three months or more), remove the

batteries. Replace worn batteries with their polarities in the correct direction. TIME AND OF SYSTEM SETUP

1. Press the “SET” key to turn the device on.
2. Press and hold the “SET” key until the year number displays and flashes on LCD

to enter the setting mode.

3. Press the “MEM” key to adjust the year, then press the “SET” key again to save

your setting and enter the month setting mode.

4. Press the “MEM” key to adjust the month. Following the same steps to adjust

date/hour/minute.

Page 9 of the Cresta BPM620 user manual — ATTACHING THE ARM CUFF
Seite 9 · Zum Vergrößern klicken
Seite 9
Cresta BPM620 — UNIT CONVERSION mmHg/kPa DISPLAY diagram (page 9)
Abb. 4 · UNIT CONVERSION mmHg/kPa DISPLAY

UNIT CONVERSION mmHg/kPa DISPLAY

The default setting of the monitor is mm Hg. Also kPa (kPa) can be set.

Boots continued to press the ON/OFF button exceeding five seconds.

The units will be chosen by the above shows mmHg/kPa after decontrol. After the

normal boot unit values are shown as blood pressure. Also select memory unit value

changes.

Cresta BPM620 — UNIT CONVERSION mmHg/kPa DISPLAY diagram (page 9)
Abb. 5 · UNIT CONVERSION mmHg/kPa DISPLAY

WHO BLOOD PRESSURE CLASSIFICATION DISPLAY

Diastolic blood pressure reference material: Journal of hypertension 1999. vol 17 No.2

Grade 3 hypertension (severe)

Grade 2 hypertension (moderate)

Grade 1 hypertension (mild)

ATTACHING THE ARM CUFF

1.Wrap the arm cuff around the upper arm, about 2 - 3 cm above the elbow.

High-normal · Normal · Optimal

Page 10 of the Cresta BPM620 user manual — READ MEMORY
Seite 10 · Zum Vergrößern klicken
Seite 10

Place the cuff direct to the skin, as clothing may cause a faint pulse, and result in a

measurement error.

2.Constriction of the upper arm, caused by rolled up shirtsleeves, may prevent

accurate readings.

3.Secure the arm cuff with Velcro Strip in such a way that it lies comfortably and is

not too tight. Lay the arm on the table with the hand palm upwards so that the arm

cuff is at the same height as the heart. Make sure that the tube is not kinked.

4.Measure your arm circumference for the cuff selection, refer to “Specifications”

How to take proper measurements

For the best accuracy in blood pressure measurement:

PATIENT position in NORMAL USE, including:

1. take a comfortable seat
2. keep your legs uncrossed.
3. place your feet flat on the floor.
4. keep your back and arm supported.
5. put the middle of the CUFF at the level of your heart.

Remain still and keep quiet during the measurement.

Relax as much as possible and do not talk during the measurement process.

Measure your blood pressure at about the same time every day.

Do not measure right after a physical exercise or a bath. Take a rest for twenty to thirty

minutes before taking the measurement.

The readings can be affected under the below conditions:

Within an hour after dinner, after having wine, coffee, tea, sports, bathing,

talking, being nervous, being in an unsteady mood, bending forward, moving, room

temperature dramatically changing during measuring, in moving vehicles, long

time continuous measuring.

HOW TO MEASURE BLOOD PRESSURE

1. Set up the arm cuff to your upper arm as previous described in the section

“ATTACHING THE ARM CUFF”

2. Press the “ON/OFF” button, all icons appear two seconds on the display, then it will

switch to measurement and will display “0” or the last measurement recorded.

3. Start the measurement, the cuff in the strap will automatically inflate. The mark () will

flash on LCD till the measurement is completed. The LCD display will show the

measurement results.

READ MEMORY

Press the “MEM” button, to read out the latest measurements. Press the “MEM” button

for the latest results (UP) or the “SET” button for the memory (DOWN)

Power Measurement closure or after the end of the state you can press the “MEM”

Page 11 of the Cresta BPM620 user manual — SPECIFICATIONS
Seite 11 · Zum Vergrößern klicken
Seite 11

button to read out the latest measurement of the memory.

DELETE MEMORY

Press the “MEM” button for five seconds, the LCD will display “No”. The memory has

been deleted.

CARE AND MAINTENANCE

To keep your digital blood pressure monitor in the best condition and to protect the

unit from damage, please follow the directions listed below:

Keep the monitor in the storage case when not in use.

Do not fold the arm cuff too tightly. The fabric fastener could touch the inner surface

of the arm cuff and damage it.

Clean the monitor and the cuff with a soft dry cloth.

Do not use any abrasive or volatile cleaners.

CAUTION

* Do not submerge the device or any of the components in water.

* Do not subject the monitor to extreme hot - or cold temperatures, humidity or direct

sunlight.

* Store the device and the components in a clean, safe location.

* Do not subject the monitor to strong shocks, such as dropping the unit on the floor.

* Remove the batteries if the unit will not be used for three months or

longer. Always replace all the batteries with new ones at the same time.

This product is designed for use over an extended period of time.

SPECIFICATIONS

Measuring Method Oscillometric Measurement

Indication Digital LCD display

Measuring Range Pressure30~280 mmHg
Pulse40~199 Beat/min
Accuracy Static Pressure± 3mmHg Pulse: ± 5%

Power supply 4x 1.5V Batteries (LR6 or AA)

use alkaline battery, measure above 200

Operating condition+5 ℃ ~+40 ℃ . 15%RH~93%RH
Storage condition-20 ℃ ~+55 ℃ . 0%RH~93%RH
Atmospheric pressure70kPa~106kPa

Atmospheric pressure:50kPa~106kPa

Dimensions Approx.: 96(W)X130(H)X60(D)mm

WeightApprox.: 380g, excluding batteries

Memory 90 Memories · times

Page 12 of the Cresta BPM620 user manual — DELETE MEMORY
Seite 12 · Zum Vergrößern klicken
Seite 12
Cresta BPM620 — DELETE MEMORY diagram (page 12)
Abb. 6

Specifications may be changed without notice in the event of improvements

being made.

1.Type of protection against electric shock: INTERNALLY POWERED EQUIPMENT.

2.Degree or protection against electric shock: TYPE BF APPLIED PART.

3.Mode of operation: CONTINUOUS OPERATION.

4.Equipment not suitable for category AP&APG equipment use in presence. STATEMENT

The system might not meet its performance specifications if stored or used outside

Operating conditions+5 ℃ ~+40 ℃ . 15%RH~93%RH 70kPa~106kPa

the temperature and humidity as mentioned below:

Storage conditions-20 ℃ ~+55 ℃ . 0%RH~93%RH TROUBLESHOOTING

lf you have trouble in using the unit please check the following points first.

Cresta BPM620 — DELETE MEMORY diagram (page 12)
Abb. 7

E3 inflate pressure too high Re-measurement or send back

Battery icon on Battery low power Replace battery and measure

Page 13 of the Cresta BPM620 user manual — DELETE MEMORY
Seite 13 · Zum Vergrößern klicken
Seite 13

The systolic pressure value or

1.The arm cuff was held

higher than your heart

2.you moved your body or

a) a statement to the effect that this equipment needs to be installed and put into

service in accordance with the information provided in the ACCOMPANYING

b) a statement to the effect that wireless communications equipment such as wireless

home network devices, mobile phones, cordless telephones and their base stations,

walkie talkies can affect this equipment and should be kept at least a distanced away

from the equipment. The distanced is calculated by the MANUFACTURER from the 800

MHZ to 2,5 GHz column of Table 5 or Table 6 of IEC 60601-1-2:2007, as appropriate.

The crossed out “wheeled bin” icon on the product reminds you of your

obligation that when you dispose of the appliance, it should be separately collected.

local authority for information concerning the correct disposal of your old appliance.

Printing errors and modifications provided, July 2016

Show 6 more labels / short text on this page
diastolic pressure value · too low · Spoke during measurement · Regarding EMC Statement · DOCUMENTS; and · Contact your
Display-Codes

Fehlercodes

Was die auf dem Display angezeigten Fehlercodes bedeuten und wie man sie behebt.

CodeBedeutungLösung
E1can’t normally Increase p.12

Frage zu Cresta BPM620 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Cresta BPM620

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Cresta BPM620 PDF-Anleitung

56 Seiten·2.7 MB·Blutdruckmessgerät·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…