Thank you for purchasing this product.
This product complies with the statutory national and European requirements.
To maintain this status and to ensure safe operation, you as the user must observe these operating instructions!
These operating instructions are part of this product. They contain important notes on commissioning and handling. Also consider this if you pass on the product to any third party.
Therefore, retain these operating instructions for reference!
All company names and product names are trademarks of their respective owners. All rights reserved.
If there are any technical questions, contact:
Fax. no.: +49 9604 / 40 88 48
Mon. to Thur. 8.00am to 4.30pm, Fri. 8.00am to 2.00pm
Dear Customer,

The weather station serves to display different measuring values, e.g. the indoor/outdoor temperature and the indoor/outdoor air humidity, barometric pressure and barometric pressure development. Furthermore, the weather station calculates a weather forecast for the next 12- 24 hours from the barometric pressure development.
The data measured by the outdoor sensor are wirelessly transferred to the weather station.
The time and date can be automatically set by DCF time signal. It can also be set manually, however (e.g. in case of reception problems).
For a list of all features and characteristics of the product, see chapter 5.
The manufacturer assumes no responsibility for incorrect displays, measured values or weather forecasts and their consequences.
The product is intended for private use; it is not suitable for medical use or informing the public.
The product is operated with batteries.
The parts of this product are no toys. They contain fragile and swallowable glass and small parts, as well as batteries. Keep the product away from children!
Operate all components so that they cannot be reached by children.
Any other use than described above may damage the product and poses additional dangers.
Read these operating instructions completely and attentively; they contain a lot of important information on setup, function and operation. Always observe the safety information!
An exclamation mark in a triangle indicates important notes in these operating instructions that must be strictly observed.
The “hand” symbol indicates special information and advice on operation.


The guarantee/warranty will expire if damage is incurred resulting from non- compliance with these operating instructions. We do not assume any liability for consequential damage!
Nor do we assume any liability for damage to property or personal injury caused by improper use or failure to observe the safety information. In such cases the guarantee/warranty will expire!
Therefore, first let the product reach room temperature before using it. This may take several hours.

Operation of the outdoor sensor of the weather station with rechargeable batteries is generally possible.
The lower voltage of rechargeable batteries (rechargeable battery = 1.2 V, battery = 1.5 V) and the lower capacity, however, leads to a shorter operating duration and may reduce the radio range. Moreover, the rechargeable batteries are more cold-sensitive than batteries.
If you want to use rechargeable batteries in spite of these limitations, always use special NiMH batteries with a low self-discharge.
We recommend that you use high-quality alkaline batteries to ensure long and safe operation.
The weather station requires 3 batteries of the type AA/Mignon; the outdoor sensor requires 2 batteries of the type AAA/Micro.



2 Symbol “DCF” for DCF time
3 Symbols for wake-up/alarm function
6 Unit for indoor temperature (switchable between °C/°F)
8 Symbol “HI AL” and “LO AL”; alarm for indoor temperature/indoor humidity
9 Symbol “ ” = Alarm for indoor temperature/indoor humidity activated
10 Units for barometric pressure (hPa, InHg)
12 Symbol “HI AL”; alarm for barometric pressure
13 Symbol “ ” = Alarm for barometric pressure activated
14 Graphic icons for weather forecast
15 Arrows for weather change
16 Symbol “MIN”/MAX” (appears for display of minimum/maximum values)
17 Symbol “LO AL”; alarm for barometric pressure
18 Switching of barometric pressure (“rel” = relative, “abs” = absolute)
19 Bar graph for display of the barometric pressure progress over the last 24 hours
20 Symbol “ ” = Alarm for outdoor temperature/outdoor humidity activated
21 Symbol “HI AL” and “LO AL”; alarm for outdoor temperature/outdoor humidity
22 Display mode “TEMP” (outdoor temperature) and “DEW POINT” (dewpoint temperature)
23 Unit for outdoor temperature (switchable between °C/°F)
25 Symbol “ ” for reception of the outdoor sensor signal
28 Symbol “ ” = Alarm function activated
29 Radio tower symbol “ ” (appears when DCF signal was recognised)

Then the weather station searches for the outdoor sensor and the display shows “ “.
The sensor search takes about 3 minutes; do not move the weather station and the outdoor sensor during this period and do not push any button.
The search for the DCF signal and assessment of the signal may take up to 10 minutes; do not move the weather station during this time and do not push any button.
If no DCF signal is recognised within 1 minute, the weather station interrupts the DCF search and will restart it after 2 hours.
If you want to restart the DCF signal search manually, remove the batteries from the weather station. Wait for 10 seconds and re-insert them.

When drilling and screwing, ensure that no cables or lines are damaged.
To be able to read the display integrated in the outdoor sensor, we recommend that the outdoor sensor be installed to the left or right of a window.
Select the mounting site so that the outdoor sensor is not subject to direct solar irradiation, because temperature measurement will otherwise be incorrect. The same applies if rain or snow gets on the outdoor sensor.

The DCF signal is sent by a station in Mainflingen (near Frankfurt am Main). Its range is up to 1500 km, and under perfect reception conditions even up to 2000 km.
The DCF signal contains, among others, the precise time (deviation theoretically 1 second in one million years!) and the date.
This means you do not have to switch manually between daylight savings time and normal time; the time is adjusted automatically.
The first DCF reception attempt is always performed when the batteries are inserted into the weather station; see chapter 9.
A DCF reception attempt is performed several times per day. A single proper reception of the DCF signal per day will keep the deviation of the clock in the weather station below a second.
If you do not see any current time in the display of the weather station after 10 minutes, remove the batteries from the weather station. Wait for 10 seconds and re-insert them.
The search for the DCF signal and assessment of the signal may take up to 10 minutes; do not move the weather station during this time and do not push any button.

“DEW POINT” Dewpoint temperature
The dewpoint is the temperature to which condensate just starts to form on an object.
To leave the selection menu, either briefly push the button “SNOOZE/LIGHT” on the top of the weather station (alternatively wait for 10 seconds without pushing any button).
The absolute barometric pressure is the actually measured barometric pressure. It depends on the altitude of your place of residence.
The relative barometric pressure is converted to sea level to get comparable values. The data you will receive, e.g., online, are always indicated like this.
To display the correct data, the relative humidity can be corrected in the setting mode, see chapter 12. c).
“TEMP” Outdoor temperature · “rel” Relative humidity · “abs” Absolute humidity

Various basic settings are possible in the setting mode. The time and date can be entered manually here as well if no DCF reception is possible.
The following functions are available:
The setting mode is started by pushing the button “SET” for two seconds. The weather station then emits a sound signal.
Briefly pushing the button “SET” takes you to the respective next setting.
Use the button “+” or “MIN/MAX” to change the set value. Keeping the respective button down for some time will adjust quickly.
Leave the setting mode by briefly pushing the button “SNOOZE/LIGHT” or make the last setting (alternatively wait for 10 seconds without pushing any button).
Proceed as follows:
Use the button “+” or “MIN/MAX” to adjust the time zone in the area of +12 to -12 hours.
Use the button “+” or “MIN/MAX” to switch the display 24 h and 12 h mode. In 12h mode, “PM” is displayed to the left of the time in the second half of the day.

Set the hours with the button “+” or “MIN/MAX”.
When changing the time (hours/minutes) or date (year/month/day), the radio tower icon “” for DCF-reception goes out.
The manual settings for time and date are automatically overwritten when the weather station receives a correct DCF signal again! The radio tower icon “ ” is then displayed again.
If you want to start a reception attempt for the DCF signal yourself, proceed as described for initial commissioning (chapter 9 b).
Set the minutes with the button “+” or “MIN/MAX”.
Set the year with the button “+” or”MIN/MAX”.
Set the month with the button “+” of “MIN/MAX”.
Set the date with the button “+” or “MIN/MAX”.
Select the desired unit with the button “+” or “MIN/MAX”.
°C = Degrees Celsius
°F = Degrees Fahrenheit
If you have a more accurate measuring device available for humidity, the value displayed by the weather station can be corrected with the button “+” or “MIN/MAX”. Set the same humidity value at the weather station that your measuring device displays as well.
Briefly push the button “ALM” to have the uncelebrated value displayed if required. Push the button “ALM” again to return to barometric pressure setting.
Proceed as described above for indoor humidity calibration.

Select the desired unit with the button “+” or “MIN/MAX”.
“inHg” = inch mercury column
Set the relative barometric pressure with the button “+” of “MIN/MAX”.
If you have selected absolute barometric pressure display as described in chapter 12. b), the weather station will automatically switch to relative barometric pressure while this setting is made (the display shows the symbol “rel” above the barometric pressure).
You can get the current barometric pressure at your place of residence, e.g. online. Usually, it is sufficient to set the barometric pressure for the next larger city, since there are not usually any larger deviations within an area of 50 km.
In areas with larger barometric pressure fluctuations, a higher value can be set. Usually, however, you do not need to change the default.
Set the step width with the button “+” or “MIN/MAX” (2 4 hPa).
For example, if you set 4 hPa, the barometric pressure must increase or drop by 4 hPa for the weather station to recognise this as a weather change and to update the graphical symbols for the weather forecast.
If the barometric pressure drops by more than 4 hPa within 3 hours, the weather station displays the weather icon “Storm”. In areas with larger barometric pressure fluctuations, a higher value can be set.
Set the step width with the button “+” or “MIN/MAX” (3 9 hPa).
“hPa” = Hectopascal

When certain measured values are exceeded or undercut, the weather station may output a signal sound. A wake-up time can be set as well. The following settings can be made:
Mode “HI AL” (= High-Alarm, alarm when a set measured value is exceeded)
Mode “LO AL” (= Low-Alarm, alarm when a set measured value is undercut)
Proceed as follows:
- Briefly push the button “ALARM” 1x -> Change settings for High-Alarm (“HI AL”) (Alarm
when exceeding a specific measured value); the display shows “HI AL”
- Briefly push the button “ALM” 2x -> Change settings for Low-Alarm (“LO AL”) (Alarm when
undercutting a specific measured value); the display shows “LO AL”
- Briefly push the button “ALM” 3x -> Cancel; return to regular display
Each time, the display shows if an alarm is already active. For this, the symbol “ ” is displayed in the corresponding display area.

When the alarm is switched on, the symbol “ ” appears in the corresponding display area.
This also applies for the wake-up function; the symbol “ ” is displayed to the right of the time.
Leave the setting mode prematurely by briefly pushing the button “SNOOZE/LIGHT” or wait for 10 seconds without pushing any button.
- Push the button “SET” briefly repeatedly until the regular display appears again
- Briefly push the button “SNOOZE/LIGHT”
- Wait for 10 seconds without pushing any button

The alarm mode “HI AL” must be used when an alarm is to be output if the measured value exceeds the value set by you.
The alarm mode “LO AL” must be used when an alarm is to be output if the measured value undercuts the value set by you (this is the case in the example used!).
Set a value of 30% with the button “+” or “MIN/MAX” (for quick adjustment, keep the respective button pushed).
- Push the button “SET” briefly repeatedly until the regular display appears again
- Briefly push the button “SNOOZE/LIGHT”
- Wait for 10 seconds without pushing any button

Stopping the Alarm Signal
When the wake-up signal is triggered at the set wake-up time, the icon “ ” flashes additionally to the right of the time display in the weather station display.
The wake-up signal is automatically terminated after 120 seconds. To terminate it prematurely, briefly push one of the four buttons “SET”, “ALM”, “MIN/MAX” or “+” on the front of the weather station.
The wake-up signal is triggered again at the set time on the next day until you switch off the wake-up function.
Snooze mode for the wake-up signal
The wake-up signal can be interrupted for 5 minutes if you briefly push the button “SNOOZE/ LIGHT” on the top of the weather station. The icon “ ” to the right of the time flashes.
Then the wake-up signal is started again.
The snooze mode can be started several times in sequence (max. 5 times).
When a set value (e.g. outdoor temperature) is exceeded or undercut, the weather station will issue an alarm (duration approx. 120 seconds). The respective icon “HI AL” or “LO AL” will also flash in the display area for the respective value.
To terminate the alarm signal prematurely, briefly push any button.
The corresponding icon “HI AL” or “LO AL” and “ ” will continue to flash.
When the measured value leaves the warning range, the icons will disappear and the alarm is reset.
Observe that the signal sound will not be triggered again for the same alarm within the next 10 minutes. This is to avoid continuous alarm in case of fluctuating weather.
Terminating alarm signal

Briefly press the button “MIN/MAX” repeatedly to switch between the following displays:
If you do not push any button for 10 seconds, the display mode for maximum/minimum values is left automatically.
If you want to know when the respective maximum and minimum values have appeared, first call display of the maximum or minimum values with the button “MIN/MAX” as described above.
Repeatedly push the button “+” briefly to select the desired value (the respective selected value flashes in the display):
In the display, the precise time and date are displayed, e.g. for when the lowest outdoor temperature was measured over night.
While a single maximum or minimum value is displayed and flashes, it can be deleted by pushing the button “SET” for 2 seconds.
The current measured value is displayed as the new maximum and minimum value until another change happens.
It is not possible to delete all maximum and minimum values at once. You need to delete each value separately.
This is a little more difficult than for common weather stations, but it enables you to choose yourself which maximum and minimum values you want to delete or keep.

The weather station calculates a weather forecast for the next 12 - 24 hours from the barometric pressure development of the last hours/days. The accuracy that can be achieved with this technology is at about 70%.
Therefore, do not rely on the weather station’s forecast but gather information on site, e.g. for mountain tours.
The display symbols indicate a weather change for the better or worse, which does not have to mean sun or rain, however, as indicated by the symbols.

When arrows appear between the weather forecast graphics, they indicate weather trend.
Examples:
When the weather remains stable, both graphics will show the same weather, and no arrows will be displayed.
In the default settings, the barometric pressure must rise or drop by 2 hPa for the weather station to recognise a weather change.
As described in chapter 12. c), this value can be changed between 2 and 4 hPa. In areas with larger barometric pressure fluctuations, for example, a higher value can be set.
If the barometric pressure drops by a specified value within 3 hours, the weather station displays the weather icon “Storm”.
In the default setting of the weather station, the barometric pressure must drop by 4 hPa.
As described in chapter 12. c), this value can be changed between 3 and 9 hPa. In areas with larger barometric pressure fluctuations or barometric pressure differences, for example, a higher value can be set.

In the upper area of the LC display of the weather station, a bar chart display shows the air pressure trend of the last 24 hours as a chart.
After inserting the batteries into the weather station, no measured values are present for the last 24 hours, obviously, and all bars are the same height.
Briefly press the button “SNOOZE/LIGHT” to activate lighting. It goes out automatically after a few seconds.
The batteries must be replaced when the display contrast is very weak or the display disappears when the illumination is activated. When replacing the batteries, all measured data are lost. See chapter 9. b) for the battery change.
Since the outdoor sensor works with a safety code (which permits operating several weather stations of the same build in parallel), proceed as follows:
All data of the weather station are lost and must be re-programmed.
If the batteries of the weather station are not removed and inserted again, the weather station will no longer be bale to find the outdoor sensor, since it has received a new safety code after the battery change.

With this weather station, you purchased a product built to the state of the art and operationally safe. Nevertheless, problems or errors may occur. The following contains descriptions for the removal of possible interference.
No reception of the outdoor sensor signal
Buildings made of reinforced concrete, metal-coated insulating glass windows and setup in a basement also prevent good reception of the DCF signal.
Just wait for the next day; the weather station should display the DCF time and date then.
No DCF Reception

The range for radio signal transmission between the outdoor sensor and the weather station is up to 100 m under best conditions.
However, these range values refer to the so-called “free field range”.
This perfect alignment (e.g. weather station and outdoor sensor on a smooth, level meadow without trees, houses, etc.), however, is never present in practice.
Usually, the weather station is put up in the house, and the outdoor sensor next to a window.
Due to the different influences on radio transmission, no specific range can be guaranteed for, unfortunately.
Usually, however, any operation in a family home is possible without any problems.
When the weather station doesn’t receive any data from the outdoor sensor (despite new batteries), reduce the distance between the outdoor sensor and weather station, change the installation site.
The range may be considerably reduced by:

We, Conrad Electronic, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare that this product complies with the fundamental requirements and the other relevant regulations of the directive 1999/5/EC.
The declaration of conformity for this product is available at www.conrad.com
The product is maintenance-free for you. Servicing or repair must only be carried out by a specialist or specialist workshop. There are no parts that require maintenance by you inside the product. Therefore, never open it (except for the procedure described in these operating instructions for inserting or replacing the batteries).
A dry, soft and clean cloth is sufficient for cleaning the outside of the weather station.
Do not apply too much pressure to the display; this can cause scratch marks or failures of the display.
Remove dust on the weather station with a long-haired, soft and clean brush and a vacuum cleaner.
To remove contamination at the outdoor sensor, use a soft cloth slightly moistened with lukewarm water.
Never use any aggressive cleaning agents, cleaning alcohol or other chemical solutions, since these may damage the casing or even impair function.

Dispose of the product according to the relevant statutory regulations at the end of its service life.
Remove any inserted batteries/rechargeable batteries and dispose of them separately from the product.
You as the end user are required by law (Battery Ordinance) to return all used batteries/ rechargeable batteries. Disposing of them in the household waste is prohibited!
Batteries and rechargeable batteries containing hazardous substances are marked with adjacent symbol to indicate that disposal in the household waste is prohibited. The descriptions for the respective heavy metal are: Cd=cadmium, Hg=mercury, Pb=lead (the names are indicated on the battery/rechargeable battery e.g. below the rubbish bin symbol shown to the left).
You may return used batteries/rechargeable batteries free of charge at the official collection points of your community, in our stores, or wherever batteries/rechargeable batteries are sold!
You thus fulfil your statutory obligations and contribute to the protection of the environment.

Power supply 3 AA/mignon batteries Battery lifetime approx. 1 year Temperature measuring range 0 °C to +60 °C
Resolution 0,1 °C Accuracy +/-1 °C Humidity measuring range 1% to 99% relative humidity
Resolution 1% Accuracy +/-5% Barometric pressure measuring range 919 - 1080 hPa
Resolution 0.1 hPa Accuracy +/-1.5 hPa Dimensions 100 x 186 x 31 mm (W x H x D) Weight 251 g (without batteries)
Power supply 2 type AAA/Micro batteries Battery lifetime approx. 1 year Transmission frequency 433 MHz Range up to 100 m (in the free field, see Chapter 15) Transmission interval every 48 seconds Degree of protection IPX4 Temperature measuring range -40 °C to +65 °C
Resolution 0,1 °C Accuracy +/-1 °C Humidity measuring range 20% to 95% relative humidity
Resolution 1% Accuracy +/-5% Dimensions 61 x 84 x 22 mm (W x H x D, no wall holder) Weight 62 g (with wall holder/batteries)

Diese Bedienungsanleitung ist eine Publikation der Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). Alle Rechte einschließlich Übersetzung vorbehalten. Reproduktionen jeder Art, z. B. Fotokopie, Mikroverfilmung, oder die Erfassung in elektronischen Datenverarbeitungsanlagen, bedürfen der schriftlichen Genehmigung des Herausgebers. Nachdruck, auch auszugsweise, verboten. Diese Bedienungsanleitung entspricht dem technischen Stand bei Drucklegung. Änderung in Technik und Ausstattung vorbehalten. © Copyright 2013 by Conrad Electronic SE.
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved. © Copyright 2013 by Conrad Electronic SE. V2_1213_01
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.