We are very pleased that you have decided in favor of a product from our range. Our name stands for high quality and thoroughly tested products in the fields of heat, gentle therapy, blood pressure/diagnosis, weight, massa- ge and air. Please read these instructions for use carefully and comply with the directions.
With best regards Your Beurer Team
Read through these instructions for use carefully before first use. Keep them to hand for later use and ensure that they are accessi- ble to other users.
When in use, there may be an intense heat build-up on the skin or nail. – Check results regularly during treatment. This is particularly advisable in
the case of diabetics, as they are less sensitive to pain and are liable to become injured more easily. Attachments 1, 2, 3, 4 and 5 that are provi- ded are basically suitable for diabetics as they are only used for treatment of areas rather than specific points. Attachments 6 and 7 are, however, less suitable for diabetics. Always use with extreme care. If in doubt, ask your doctor. – This instrument must be used only for the purpose for which it has been
developed, and in the manner described in the instructions for use. Any improper use can be dangerous. – In case of prolonged intensive use (e.g. milling of dead skin from your
feet) the device might get very hot. In order to prevent skin burns in these situations, there should be longer breaks between each application. For your own safety, constantly monitor heat build up in the device. This par- ticularly applies to people who are insensitive to heat. – The device is only for private use and is not intended for medical or com-
mercial purposes.

– For reasons of hygiene, the device should only be used on one person. – The manager is not responsible for damage or injury caused by improper
or incorrect use. – Ensure before use that there is no visible damage to the instrument and
accessories. In the event of doubt, do not use them and contact your dealer or the customer service address stated. – Keep children away from the packaging materials. Risk of suffocation. – The appliance must be checked frequently for signs of wear or damage.
If such signs are present, or if the appliance has been used improperly, it must be taken to either the manufacturer or the dealer before further use. – Switch off the instrument immediately in the event of defects or malfunc-
tions. – Repairs may be carried out only by the customer service or authorized
dealers. – On no account try to repair the instrument yourself! – Use the instrument only with the accessories provided. – Never operate the appliance without supervision, particularly when children are in the vicinity. – Do not use on small animals/animals. – Prevent all contact with water (except when cleaning with a slightly moi-
stened cloth!). Water must never enter the inside of the appliance. Never immerse the appliance in water. On no account use the appliance in the bath, in a shower, in a swimming pool or over a water-filled wash basin. In the unlikely event that water gets into the case, disconnect the appli- ance immediately from the mains and contact your specialist electrical supplier or customer service. – Keep the instrument away from sources of heat. – Do not use the instrument under blankets, pillows etc. – The instrument must not be operated continuously for longer than 20 mi-
nutes. After this time, wait an interval of at least 15 minutes to prevent the motor from overheating. – Ensure your hands are dry before handling either the instrument or the
plug-in power unit. – Do not pull on the power cord or instrument to unplug the plug-in power
unit from the socket outlet. – The plug-in power unit must be operated only from a power supply as
specified on it. – The appliance should only be operated with the power unit provided. – After use, before cleaning and changing any accessory parts, the power
unit should always be disconnected.

– This device is not intended for use by persons (including children) with
restricted physical, sensory or mental capabilities and/or by persons lacking the required understanding of the equipment and how it is used, unless they are supervised by a person who is responsible for their safety or they are given instructions on how to use the device. – Children should be supervised to ensure that they do not use the device
as a toy.
This manicure and pedicure instrument is equipped with high-quality at- tachments. The basic version includes 7 attachments with long-life sapphire coating or polishing felt. Together with the 2-level speed control and clockwise/anticlockwise ope- ration, this ensures a professional pedicure and manicure that would other- wise only be possible at a podiatrist. The integrated LED light additionally creates ideal light conditions during application.
3.1 General
– This instrument is intended only for the treatment of hands (manicure)
and feet (pedicure). – Select an attachment and push it onto the instrument spindle using a
slight pressure. To remove: pull the attachment and instrument apart in the axial direction (straight). – Switch the device on by moving the slide switch down (anticlockwise,
LED red) or up (clockwise, LED green). – All file and cutting attachments are coated with a sapphire grain. This guarantees extremely long life and almost guarantees freedom from wear. – You can select one of two speed settings (Hi and Lo). Press the corre-
sponding button on the device – Do not exert heavy pressure and always guide the attachments carefully
over the surface to be treated. – Move the instrument under light pressure in circular movements slowly
over the parts to be treated. – Note that the cutting attachments will have a reduced effect if the skin is
softened or moist. For this reason, do not carry out any pretreatment in a bath.

– Do not remove all the callus skin in order to retain the natural protection
of the skin. – Always ensure that the spindle can rotate freely. It must never be perma-
nently jammed, otherwise the instrument will become too hot and suffer damage. – After every use, apply moisturizing cream to the parts treated.
Check the results during treatment. This is particularly important for diabetics, since their hands and feet are less sensitive.
As these are attachments for use by professionals, we would ask you to handle them with care as they can cause injury when used incorrectly. Par- ticular caution is advised at higher speeds.
The following attachments are provided with your appliance:
Filing and treatment of the nails, fine grained sap- phire disk. The specific aspect of this sapphire disk is that only the inner disk rotates, while the outer support is stationary. This enables precise filing of the nails without the risk of burning the skin with the fast rotating disk.
Filing and treatment of the nails, coarse grain sap- phire disk. This attachment allows you to shorten even thick nails by filing. Since it quickly removes large areas of the nail, you should proceed with cau- tion in this case also.
Removal of dry skin or calluses from the soles of the feet and from the heels and for manicuring the nails.

Smoothing and polishing the edge of the nail after filing as well as for cleaning the nail surface. Always polish in circular movements and do not allow the felt cone to rest in one place, otherwise friction could cause heat to develop.
For rapid removal of stubborn calluses and hard skin on the soles of feet and heels This attachment can be used on large areas.
Grinding of lignified foot nail surfaces as well as smoothing of these. For this purpose, apply the milling cutter horizontally to the nail surface and re- move the unwanted layer of nail using slow circular movements.
For removing ingrowing nails. Carefully guide the flame cutter up to the part to be treated and remove parts of the nail as necessary.
When filing, always work from the outside of the nail towards the tip! Always check results regularly during treatment. As soon as the application becomes unpleasant, stop the treatment.
Before cleaning the power unit, always unplug it from the socket outlet! – Clean the instrument with a slightly moistened cloth. You can also moisten the cloth with mild soap suds to remove more stubborn dirt. – If necessary, for reasons of hygiene, the attachments can be cleaned with
a cloth or brush moistened with alcohol. Dry them carefully afterwards. – Do not drop the instrument.

– Make sure that no water enters the instrument. But if this should happen,
do not use the instrument again until it is completely dry. – Do not use chemical detergent or scouring agents for cleaning. – Never immerse the instrument or plug-in power unit in water or other
liquids.
Please dispose of the device in accordance with the directive 2002/96/EG – WEEE (Waste Electrical and Electronic Equipment). If you have any queries, please refer to the local authorities responsi- ble for waste disposal.