Signs and symbols The following symbols appear in these instructions for use:

1. Intended use

This air humidifier is designed for the humidification of ambient air. The device is intended for private use.

2. Safety notes

Read these instructions for use carefully. Non-observance of the following information may result in personal injury or material damage. Store these instructions for use and make them accessible to all users. Make sure to include these instructions for use when handing over the device to third parties.

Electric shock

  • As with every electrical device, use this air humidifier carefully and cautiously, in order to avoid hazards due to electric shock.
  • O nly operate the device at the voltage indicated on the device (the type plate is located on the underside of the base unit).
  • O nly insert the mains cable into the socket when the device is switched off.
  • N ever use the device if it or its accessories are visibly damaged.
  • D o not use the device if it has sustained a fall or if water has penetrated the device interior.
  • D o not use the device during a storm.
  • I n the event of defects or operational faults, switch off the device immediately and disconnect the device from the mains socket.
  • D o not pull on the mains cable or on the device to disconnect the plug from the socket.
  • N ever hold or carry the device by the mains cable.
  • D o not clamp or pinch the mains cable.
  • K eep the mains cable away from hot surfaces.
  • E nsure that the mains cable and plug do not come into contact with water, steam or other liquids.
  • O nly use the device in dry internal rooms (e.g. never in the bathroom, sauna, etc.).
  • N ever reach for a device that has been submerged in water. Pull the plug out of the mains socket immediately.
  • D o not subject the device to any impacts or drop the device.

Repairs

  • D o not open the base unit.
  • O nly specialist personnel may perform repairs on electrical devices. Improper repairs may subject users to considerable danger. For repairs, please contact customer service or an authorised retailer.
  • I f the mains cable of the device is damaged, it must be replaced by the manufacturer or an authorised customer service point.
Page 3 of the Beurer LB37 user manual — 4. Device description
Seite 3 · Zum Vergrößern klicken
Seite 3

Risk of fire

  • There is a risk of fire if the device is used improperly or these instructions for use are ignored.
  • N ever use the device underneath a cover, such as a blanket or pillow.
  • N ever use the device near highly flammable substances.

Operation

  • T he device is only intended for the purpose described in these instructions for use. The manufacturer is not liable for damage resulting from improper or careless use.
  • T his device is not intended for use by people (including children) with restricted physical, sensory or mental skills or a lack of experience and/or a lack of knowledge, unless they are supervised by a person who has responsibility for their safety or instructed by him in how to use the device.
  • C hildren should be supervised around the device to ensure they do not play with it.
  • I f you suffer from a severe respiratory or lung disease, consult your doctor before using the air humidifier.
  • T he device must be switched off after every use and before cleaning. Pull the plug out of the mains socket.
  • E nsure that the mains cable does not pose a trip hazard.

IMPORTANT

  • E nsure that the device is placed on a firm, flat surface that is not susceptible to moisture.
  • Do not insert any objects into openings on the device. Ensure that the moving parts can move freely at all times.
  • Do not place any objects on the device.
  • Do not expose the device to high temperatures.
  • A void direct sunlight.

3. Getting to know your device

Humans spend a large proportion of their time indoors. For ideal ambient air, a humidity level of between 40 % and 60 % is recommended. This value is often not reached, particularly in winter, when cold, dry air enters living spaces that are being aired and is then warmed up. This dry ambient air draws in moisture, drying out mucous membranes and skin, but also furniture.

  • Ambient air that is too dry may have a number of negative effects.
  • M ucous membranes and lips dry out.
  • E yes become irritated.
  • I nfections and respiratory diseases are more likely to occur.
  • E xhaustion, tiredness and difficulty concentrating.
  • P ets and plants are put under unnecessary strain.
  • D ust forms more quickly.
  • E lectrostatic charging of textiles made of synthetic fibres, such as carpets and plastic floor coverings.
  • W ooden furniture and, especially, parquet floors, are damaged.
  • M usical instruments go out of tune.

4. Device description

  • The air humidifier
  • h umidifies the air,
  • q u iet operation ,
  • i s suitable for rooms up to 20 m² in size,
  • h as a low energy consumption and switches off automatically when the water tank is empty,
  • i s easy to clean,
  • features a night mode.
Page 4 of the Beurer LB37 user manual — Installation location
Seite 4 · Zum Vergrößern klicken
Seite 4
1. Mist outlet
2. Water tank
3. Water tank screwed plug
4. Water basin
5. Base unit for air humidifier
6. Ultrasound membrane
7. ON/OFF button with LED display
8. Aroma compartment

Principle behind the LB 37 air humidifier 1. High-frequency vibrations release tiny drops from the surface of the water. 2. The fan draws in air through the aroma compartment on the side of the device. 3. Water evaporation can also be switched on. 4. If you wish, the device can be used with aromas.

5. Initial use Unpacking the device

  • Keep packaging material away from children! There is a choking hazard.
  • O pen the cardboard packaging.
  • R emove the protective insert.
  • K eep the plastic film closed.
  • L ift the device up and out of the packaging.
  • R emove the plastic covering.
  • C heck the device, the mains plug and the cable for damage.

Installation location

Before putting the device into operation, read the safety notes in the Safety chapter.

  • T he immediate vicinity of the air humidifier can become damp.
  • C alcareous water can leave white deposits.
  • D o not place the device on the floor, but in a raised position (e.g. on a table or chest of drawers).
  • P osition the device so that the mist outlet is not directed towards objects.
  • E mpty any remaining water when the device is not in use.
Page 5 of the Beurer LB37 user manual — 6. Operation
Seite 5 · Zum Vergrößern klicken
Seite 5
  • P lace the air humidifier on a firm, level and water-resistant surface. If the device should accidentally tip over, water may escape, even if the device is switched off and unplugged.

Water

  • D o not add any essential oils or fragrances to the water. If additives are used, the plastic material may become discoloured and damaged. The ultrasound membrane gets stuck and is damaged.
  • U se fresh drinking water below 40°C in the device. If the drinking water is very hard, you can use demi neralised or distilled water.
  • Tip! If the water is hard, we recommend using the optional anti-limescale filter.
  • Filling the water tank
  • Lift the water tank and rotate it. The water tank is kept closed by means of a spring valve.
  • Open the screwed plug on the water tank.
  • Fill with water. The water tank holds a maximum of 2 litres.
  • Tightly close the water tank using the screwed plug.
  • Rotate the water tank and position it on the base unit. The tank should sit tightly on the base unit.

6. Operation

Check the humidity of your ambient air regularly. Intensive continuous operation can cause the ambient air to become excessively humid. The relative air humidity should not exceed 60 %.

  • Switching on the device
  • Insert the plug into the mains socket.
  • If there is no or not enough water in the water tank, a red LED lights up. The device has switched off for safety reasons.
  • Fill the water tank. Fill the water tank as described under 5. Initial use.

The device has three different modes:

LED lighting Air humidifiers Evaporation output

Press the ON/OFF button ( ) 1x blue Level 1 ~ 200 ml/h

Press the ON/OFF button ( ) 2x white Level 2 ~ 150 ml/h

Press the ON/OFF button ( ) 3x (Night mode) OFF Level 2 ~ 150 ml/h

Press the ON/OFF button ( ) 4x OFF OFF -

You may optionally add drops of aroma/scented oils to the aroma compartment (8). These will lend a pleasant odour to the room. Under no circumstances should you add the aroma directly to the water.

  • Switching off the device
  • Press the ON/OFF button ( ) 4 times. The LED lighting goes off.
  • Pull the plug out of the mains socket.
Page 6 of the Beurer LB37 user manual — Cleaning the ultrasound membrane with a brush, rinsing the base
Seite 6 · Zum Vergrößern klicken
Seite 6

In night mode, the air humidifier operates in level 2 with a lower evaporation output and no LED illumination to ensure undisturbed and therefore restful sleep.

7. Cleaning and maintenance

Regular cleaning and disinfection are a prerequisite for hygienic and fault-free operation. The level of contamination of the device depends on the water quality and how long it has been in operation. In any case, we recommend the following cleaning intervals.

Every three days As required

x Clean the ultrasound membrane with a brush, rinse the base.

x Rinse the water tank, replace the water.

x Clean the air humidifier inside and out.

x Descale.

The device must be switched off after every use and before cleaning. Pull the plug out of the mains socket.

IMPORTANT

The water tank must be cleaned and the air humidifier completely emptied if the device has not been used for over a week.

  • Note
  • C lean the device using only the methods specified.
  • U nder no circumstances may liquid enter the base unit.
  • D o not use any solvent-based cleaning products.
  • O nly use a mild flushing agent or vinegar/vinegar-based cleaner to perform cleaning or disinfection work.

Cleaning the ultrasound membrane with a brush, rinsing the base

Empty the water from the base unit via the side rim in the direction indicated by the arrow. Ensure that no water gets inside the device, e.g. via the fan opening.

Beurer LB37 — Cleaning the ultrasound membrane with a brush, rinsing the base diagram (page 6)
Abb. 1 · Cleaning the ultrasound membrane with a brush, rinsi…
  • C lean the ultrasound membrane using the cleaning brush provided.
  • E mpty the water from the base unit via the side edge.
  • S hould dirty residue remain in the base unit, pour some clean, fresh water into the base unit and empty it out via the side edge.
  • Rinsing the water tank, replacing the water
  • C lean the water tank regularly, at least once a week if using daily.
  • U se a mild cleaning agent or vinegar/vinegar-based cleaner.
  • C lean the thread of the screwed plug using a soft brush.
  • H alf-fill the water tank with water.
  • T ightly close the water tank using the screwed plug.
  • S hake the water tank by rocking it back and forth several times.
  • E mpty out the water completely.
  • R epeat the process using clean, fresh water.
  • Cleaning the air humidifier inside and out
  • E mpty the water from the base unit via the side edge.
  • W ipe the air humidifier with a damp cloth inside and out.
  • O nly use a mild flushing agent or vinegar/vinegar-based cleaner to perform cleaning work.
Page 7 of the Beurer LB37 user manual — Problem Cause Solution
Seite 7 · Zum Vergrößern klicken
Seite 7
  • Descaling Descaling the ultrasound membrane Hard water can cause limescale to build up in the device and, especially, on the ultrasound membrane. This forms white deposits. Descale the device regularly.
  • D rop some descaler onto the ultrasound membrane.
  • L eave it to take effect for two to five minutes.
  • C lean the ultrasound membrane using the cleaning brush.
  • R inse the base unit twice with clean, fresh water.
  • Cleaning inside the base unit
  • D ip a damp, soft cloth briefly in descaling solution.
  • U se the cloth to wipe the inside of the base unit.
  • C arefully pour some clean, fresh water into the base unit.
  • E mpty the water from the base unit via the side edge.
  • R epeat the process using clean, fresh water.
  • Descaling the water tank
  • H alf-fill the water tank with water.
  • A dd a small quantity of descaler.
  • T ightly close the water tank using the screwed plug.
  • S hake the water tank by rocking it back and forth several times.
  • E mpty the descaling solution completely.
  • R epeat the process twice using clean, fresh water.

8. Spare parts

  • I f the anti-limescale filter does not prevent limescale build-up, or if white deposits form on or in the device, the anti-limescale filter should be replaced.
  • T he service life of the anti-limescale filter is around two to three months at most.
  • I f the device is not used for a relatively long time, the anti-limescale filter must be removed from the water tank and dried out.
  • Fitting the anti-limescale filter
  • L ift the water tank and rotate it.
  • O pen the screwed plug on the water tank.
  • S crew the anti-limescale filter onto the screwed plug on the inside.
  • T ightly close the water tank using the screwed plug.

9. What if there are problems?

Problem Cause Solution

No LED display The mains cable is not plugged in. Connect the plug. Red LED The water level is too low; the wa ter tank is empty.

Fill the water tank.

No mist is produced The LED display lights red . Fill the water tank. The LED display does not light up.

Page 8 of the Beurer LB37 user manual — 10. Technical data
Seite 8 · Zum Vergrößern klicken
Seite 8

Problem Cause Solution

The mist has a strange smell

The device is new. Remove the water tank, turn the screwed plug and remove it. Air the open, emply water tank in a cool, dry place for twelve hours. Stale or dirty water. Empty the base unit and the water tank and clean them thoroughly. Fill the water tank with fresh water. Strange noise The water tank is not positioned correctly on the base unit.

Lift up the water tank and position it correctly on the base unit. The tank should sit tightly on the base unit.

There is too little water in the water tank.

Fill the water tank.

The device is not level and unsta ble.

Place the device on a firm, level surface.

Mist escapes underneath the water tank

Lift up the water tank. Check whether the join between the base unit and water tank is clean. Clean if required. Position the water tank correctly on the base unit. The tank should sit tightly on the base unit. The LED lights up red although the tank is full

The water tank is not positioned correctly on the base unit.

The device evaluates the water level incorrectly due to a fault.

Restart the device.

10. Technical data

Dimensions (LxWxH) approx. 21 cm x 11 cm x 25,5 cm

Cable length approx. 1.5 m

Mains voltage/frequency 100 – 240 V AC / 50/60 Hz

Nominal power max. 20 W

Room size up to 20 m²

Capacity approx. 2 litres

Evaporation output 200 ml/hour

Signs and symbols The unit is double-protected and thus corresponds to protection class 2.

Volume approx. 35dB

Page 9 of the Beurer LB37 user manual — 13. Warranty/service
Seite 9 · Zum Vergrößern klicken
Seite 9
11. Disposal For environmental reasons, do not dispose of the device in the household waste at the end of its useful life. Dispose of the unit at a suitable local collection or recycling point. Dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the local authorities responsible for waste disposal.

12. Replacement items

Replacement parts and additional items are available from the corresponding service address (according to the service address list). Please state the corresponding item number. Replacement parts and additional items are also available from retailers.

Beurer by Taoasis “Vitality” aroma oil (10 ml) 681.30

Beurer by Taoasis “Harmony” aroma oil (10 ml) 681.31

Beurer by Taoasis “Relax” aroma oil (10 ml) 681.32

Beurer by Taoasis “Sleep Well” aroma oil (10 ml) 681.33

10 aroma pads 163.801

Anti-limescale filter (optional) 163.803

13. Warranty/service

In case of a claim under the warranty please contact your local dealer or the local representation which is mentioned in the list “service international”. In case of returning the unit please add a copy of your receipt and a short report of the defect.

The following warranty terms shall apply: 1. The warranty period for BEURER products is either 3 years or- if longer- the country specific warranty period from date of Purchase In case of a warranty claim, the date of purchase has to be proven by means of the sales receipt or invoice. 2. Repairs (complete unit or parts of the unit) do not extend the warranty period. 3. The warranty shall not be valid for damages because of a. improper treatment, e.g. nonobservance of the user instructions. b. repairs or tampering by the customer or unauthorised third parties. c. transport from the manufacturer to the consumer or during transport to the service centre. d. The warranty shall not be valid for accessories which are subject to normal wear and tear (cuff, batteries etc.). 4. Liability for direct or indirect consequential losses caused by the unit are excluded even if the damage to the unit is accepted as a warranty claim.

Subject to errors and changes

Item Item number

Reparatur

Fehlerbehebung

Häufige Probleme, wahrscheinliche Ursachen und Lösungen.

ProblemMögliche UrsacheAbhilfe
Problem p.7
No LED display p.7
Red LED p.7
No mist is produced p.7
No mist is produced p.7
The mist has a strange smellThe device is new.Remove the water tank, turn the screwed plug and remove it. Air the open, emply water tank in a cool, dry place for twelve hours. p.8
The mist has a strange smellStale or dirty water.Empty the base unit and the water tank and clean them thoroughly. Fill the water tank with fresh water. p.8
Strange noiseThe water tank is not positioned correctly on the base unit.Lift up the water tank and position it correctly on the base unit. The tank should sit tightly on the base unit. p.8
Strange noiseThere is too little water in the water tank.Fill the water tank. p.8
Strange noiseThe device is not level and unsta­ ble.Place the device on a firm, level surface. p.8
Mist escapes underneath the water tankThe water tank is not positioned correctly on the base unit.Lift up the water tank. Check whether the join between the base unit and water tank is clean. Clean if required. Position the water tank correctly on the base unit. The tank should sit tightly on the base unit. p.8
The LED lights up red although the tank is fullThe device evaluates the water level incorrectly due to a fault.Restart the device. p.8
10. Technical data Dimensions (LxWxH) approx. 21 cm x 11 cm x 25,5 cm Cable length approx. 1.5 m Mains voltage/frequency 100 – 240 V AC / 50/60 Hz Nominal power max. 20 W Room size up to 20 m² Capacity approx. 2 litres Evaporation output 200 ml/hour The unit is double-protected and thus corresponds to protection Signs and symbols class 2. Volume approx. 35dB p.8

Frage zu Beurer LB37 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Beurer LB37

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Beurer LB37 PDF-Anleitung

76 Seiten·4.9 MB·Luftbefeuchter & -entfeuchter·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…