Benutzeranleitung / Produktwartung HEALTHY HOME 16N5 des Produzenten Bissell
Zur Seite of 20
USER’S GUIDE 16N5 SERIES 3 Safety Instructions 4 Product View 5 Assembly 6-9 Operation 10-15 Maintenance and Care 1 6 - 1 7 T roubleshooting 18 Consumer Ser vices 19 Replacement Parts and Accessorie.
2 T hank you for buying a BISSELL Healthy Home Vacuum ™ 2 www .bissell.ca 1-800-263-2535 W e’re glad you purchased a BISSELL vacuum. Everything we know about floor care went into the design and construction of this complete, high-tech home cleaning system.
3 I MPOR T ANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should be obser ved, including the following: REA D ALL INSTRUC TIONS BEF ORE US ING Y OUR UPR IGHT V A CUUM. Alw ays con nect to a pol ariz ed outl et (one sl ot is wid er tha n the oth er).
4 www .bissell.ca 1-800-263-2535 P roduct view Long Reach Hose T urboBrush TM Crevice T ool T elescoping Extension W and Dirt Container Headlight Height Adjustment Dial AireTight TM HEP A Filter Brush.
5 www .bissell.ca 1-800-263-2535 T oo l r eq ui re d: Ph il li ps sc re wd ri ve r 1. Slide upper handle into lo wer handle by pushing forward. Insert two long screws into the holes marked with arro ws and tighten both until snug. 2. Attach hose rack by placing the rack over the center back portion of the vacuum.
T ransporting your cleaner Us e t he ha nd le on th e fr on t t o c ar ry t he c le an er or pl ac e t he c le an er in the up ri gh t p os it io n a nd ti p b ac k t o r ol l o n th e r ea r w he el s. Releasing the power cord Th e u pp er an d l ow er co rd wra ps ro ta te to al lo w fo r q ui ck an d e as y r em ov al of th e po we r c or d.
Fingertip brush switch Th e r ot at in g b ru sh is tu rn ed on o r o ff us in g t he sw it ch lo ca te d b el ow th e p ow er swi tc h o n t he to p o f t he ha nd le . Th e b ru sh wi ll st ar t r ot at in g wh en th e u ni t i s r ec l in ed . Th e b ru sh sh ou ld be on fo r m os t c ar pe te d f lo or s.
Using the tools 1 Make sure the cleaner is in the upright position. 2. Remove the hose wand from the wand base. This automa tically diverts the suction to the hose. Unwrap the hose from the c leaner . 3. Use the hose and wand alone or attach any of the tools to the end of the hose wand.
Emptying the dirt container E mp ty t h e di r t co nt a i ne r a s so o n as th e d i r t r ea ch e s th e “F u l l” li ne o n t he s i de of th e c on ta i n er . 1. Press the release button on top of the carrying handle to remove the dirt container .
Cleaning the dirt container Ad di ti on al st ep s c an be ta ke n to c le an th e d ir t co nt ai ne r a s n ec es sa ry . 1. Ensure the dirt container has been emptied. 2. Remove the lo wer portion by pressing the front latch on the upper portion as sho wn.
Replacing the HEP A filter cartridge T he HE P A fi lt er ca rt ri d ge sh ou ld be re pl a ce d if machine performance is noticeably d ec li ni ng . Mo re or le ss fr eq u en t r ep la ci n g may be required based on individual v a cu um in g h ab i ts an d t yp es of de br i s p ic ke d u p .
Clearing c logs Low suction or poor pickup may be due to a c log in the vacuum c leaner . If you notice a change in the sound of the motor or a reduction in the spinning action in the dirt container , check for a clog.
Clearing c logs continued I f su c t io n i s no rm a l at t h e ho se , f o ll o w th es e s te ps t o ch e c k fo r a nd c l ea r t h e c l og fo r f l o or c l ea n i ng : 1. Ch ec k d iv er te r a re a at ba ck of ma ch in e f or di ve rt er po si ti on an d c log s.
14 www .bissell.ca 1-800-263-2535 M aintenance and care Brush reset If so me th in g b ec om es lo dg ed in the fo ot an d t he br us h s hu ts of f, tu rn th e c lea ne r o ff an d u np lu g fr om th e o ut le t.
15 www .bissell.ca 1-800-263-2535 Changing the light bulb 1. T urn po wer switch off. 2. Unplug c leaner from electrical outlet. 3. Recline handle for easier access to light bulb and remove 2 screws to lift off lens. 4. Remove the bulb by grasping bulb and pull- ing straight out of the socket.
16 www .bissell.ca 1-800-263-2535 T roubleshooting V a cu um c le an e r w on ’t tu rn on P o ss ib le cau se s Re me di es 1. P owe r c or d no t p lu gge d i n 1. Ch ec k e lec tr ic al plu g 2. Bl ow n fu se /t rip pe d b rea ke r 2. Ch ec k/ re pla ce fu se o r r es et b re ak er 3.
T roubleshooting 17 www .bissell.ca 1-800-263-2535 V a cu um c le an e r i s d if fi cu lt to pu s h P o ss ib le cau se s Re me di es 1 . In co rr ec t he ig ht set ti ng 1. T ur n di al to h ig he r se tt in g V is ib le du st es ca p in g f ro m c le an er P o ss ib le cau se s Re me di es 1.
18 www .bissell.ca 1-800-263-2535 For information about repairs or replacement parts, or questions about your warranty , call: BISSELL Consumer Ser vices 1-800-263-2535 Monday - Friday 8 a.
19 www .bissell.ca 1-800-263-2535 R e p l a c e m e n t p a r t s a r e a v ai l a b l e t hr o u g h B IS S E L L C on s u m e r S er v i c e s , a n a u t h o r i z e d B I S S E L L S e r v i c e C e n t r e o r b y v i s i t i n g o u r w e b s i t e .
20 www .bissell.ca 1-800-263-2535 W arranty - BISSELL Healthy Home V acuum™ ©2009 BISSELL Homecare, Inc BISSELL Canada Corporation Niagara Falls, ON L2E 6S5 All rights reserved. Printed in China Part Number 110-4103 Rev 5/09 Visit our website a t: www .
Ein wichtiger Punkt beim Kauf des Geräts Bissell HEALTHY HOME 16N5 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bissell HEALTHY HOME 16N5 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bissell HEALTHY HOME 16N5 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bissell HEALTHY HOME 16N5 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bissell HEALTHY HOME 16N5 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bissell HEALTHY HOME 16N5 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bissell HEALTHY HOME 16N5 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bissell HEALTHY HOME 16N5. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bissell HEALTHY HOME 16N5 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.