FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 271846-YTG-B-0208 ® MODELS: CH060 - 5-10 TONS HORIZONT AL MODELS: CU060 - 300 5-25 TONS VERTI CAL SINGLE P ACKAGE AIR CONDITIONING W.
271846-YTG-B-0208 2 Johnson Controls Unitary Products TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 APPLICATION FLEXIBILITY . . . . . . . . . . . . . . . . . . . 3 CABINET . . . . . . . . . . . . . . . . .
271846-YTG-B-0208 Johnson Controls Unitary Products 3 DESCRIPTION These units are completely asse mbled, piped, wired, charge d and tested at the factory and are shipped ready for immedia te installation.
271846-YTG-B-0208 4 Johnson Controls Unitary Products FACTORY INST ALLED OVERSIZED EVAPORATOR FAN MOTORS Increased horsepow er motors and drive components are available for those applicatio ns where external static pres - sure requirements exceed the capability of the standard motor .
271846-YTG-B-0208 Johnson Controls Unitary Products 5 NOTE: Cooling performance is ra te d at 80°F dry bulb 67°F wet bulb entering air temperatu re, CFM listed, 85°F enterin g 95°F leaving water temperature, and water flow rate list ed. Gross capacity does not include the effect of evapora - tor fan motor heat.
271846-YTG-B-0208 6 Johnson Controls Unitary Products NOTE: Cooling performance is ra ted at 80°F dry bulb 67°F wet bulb entering a ir temperature, CFM listed, 85°F entering 95°F leaving water temperature, and water flow rate list ed. Gross capacity does not include the effect of evapora - tor fan motor heat.
271846-YTG-B-0208 Johnson Controls Unitary Products 7 NOTE: 1. At higher evaporator airflows, and wet bulb conditions condensate ca rry -over may occur. Adjust airflow downward as necessar y. 2. Values include pressure drop from wet coil and cle an filters.
271846-YTG-B-0208 8 Johnson Controls Unitary Products NOTE: At higher evaporator airf lows and wet bu lb conditions, condensate carry-over may occu r . Adjust airflow downwa rd as necessary V alues include pressure drop from wet coil and clean filter s.
271846-YTG-B-0208 Johnson Controls Unitary Products 9 T ABLE 6: W ATERSIDE PRESSURE DROP - CU MODELS CU060 CU096 CU120 CU180 CU240 CU300.
271846-YTG-B-0208 10 Johnson Controls Unitary Products T ABLE 7: WATER PRESSURE DROP DAT A - CH MODELS.
271846-YTG-B-0208 Johnson Controls Unitary Products 11 T ABLE 8: COOLING PER FORMANCE DA T A - CH 5-10 TON HORIZONT A L MODELS CH060 5 TON 2000 CFM 9 GPM 15 GPM EWT EWT 65°F 85°F 105°F 65°F 85°F 10 5°F EWB EDB TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW 62°F 75°F 63.
271846-YTG-B-0208 12 Johnson Controls Unitary Products T ABLE 9: COOLING PER FORMANCE DA T A - CU 5-20 TON VERTICAL MODELS CU060 5 TON 2000 CFM 9 GPM 15 GPM EWT EWT 65°F 85°F 105°F 65°F 85°F 105°F EWB EDB TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW 62°F 75°F 62.
271846-YTG-B-0208 Johnson Controls Unitary Products 13 T ABLE 10: COOLING PERFORMANCE DATA - CU 25 TON VERTICAL MODELS T ABLE 1 1: WATER-SIDE ECONOMIZER COOL ING PERFORMANCE DATA - CH 5-10 TON MODELS .
271846-YTG-B-0208 14 Johnson Controls Unitary Products T ABLE 13: STANDARD MOTORS CU 5-25 TON MODELS T ABLE 12: WA TER-SIDE ECONOMIZER CO OLIN G PERFORMA NCE DATA - CU 5-25 TON VERTICAL MODELS UNIT Air @ 80°F EDB, 67°F EWB Wa t e r Capacity [MBH] CFM PD [in WG] Flow [GPM] PD [PSI] EWT [°F] To t a l Sensible CU060 2000 0.
271846-YTG-B-0208 Johnson Controls Unitary Products 15 T ABLE 14: OVERSIZED MOTORS CU 5- 25 TON MODELS T ABLE 15: ST ANDARD MOTORS CH 5-10 TON MODELS T ABLE 16: OVERSIZED MOT ORS CH 8-10 TON MO DEL S MODEL# VOL T AGE COMPRESSOR EV AP ORA TOR F AN MIN.
271846-YTG-B-0208 16 Johnson Controls Unitary Products FIGURE 1 - DIMENSIONAL DATA - CH 5 TON HORIZONTAL MODEL.
271846-YTG-B-0208 Johnson Controls Unitary Products 17 FIGURE 2 - DIMENSIONAL DATA - CH 8 & 10 TON HORIZONTAL MODELS.
271846-YTG-B-0208 18 Johnson Controls Unitary Products FIGURE 3 - PHYSICAL CONFIGURATION DAT A - CH 8 & 10 TON WATER SIDE ECONOMIZER Economizer Coil Filter Frame Electrical Connections 10 12 Water.
271846-YTG-B-0208 Johnson Controls Unitary Products 19 T ABLE 17: DIMENSIONAL D AT A - CU 5, 8, AND 10 TON VERTICAL MODELS FIGURE 4 - DIMENSIONAL DATA - CU 5, 8, AND 10 TON VERTICAL MODELS W A TER OUT W A TER IN CONDENSA TE DRAIN COMPRESSOR/CONDENSER ACCESS G C F 0.
271846-YTG-B-0208 20 Johnson Controls Unitary Products FIGURE 5 - DIMENSIONAL DATA - CU 15 TON VERTICAL MODEL 2.63” 15.88” Allow 36” minimum clearance Allow 24” minimum clearance Allow 24” minimum clearance 18.
271846-YTG-B-0208 Johnson Controls Unitary Products 21 FIGURE 6 - DIMENSIONAL DATA - CU 20 TON VERTICAL MODEL.
271846-YTG-B-0208 22 Johnson Controls Unitary Products FIGURE 7 - DIMENSIONAL DATA - CU 25 TON VERTICAL MODEL.
271846-YTG-B-0208 Johnson Controls Unitary Products 23 SUPPLY AIR/RETURN AIR CONFIGURATION All models are field convertible for multiple supp ly return con - figurations. The 5 throu gh 15 ton model s feature a removabl e upper fan module that can be rotated 180° for top rear dis - charge applications.
271846-YTG-B-0208 24 Johnson Controls Unitary Products FIGURE 9 - HOT W A TER & STEAM HEA TING COILS DIMENSIONAL DA T A Hot W ater and Steam Heating Coil Dimens ions (Inches) Unit Model A B C Inlet (MPT Outle t (MP T) CU060 37.50 5.50 23 1 1/2 1 1/2 CU096 59.
271846-YTG-B-0208 Johnson Controls Unitary Products 25 FIGURE 10 - HOT W A TER & STEAM HE A TING COILS PER FORMANCE DA T A CU240 - 300 CU060 - 180 Steam Coil Performance @ 2 PSIG • S team Heating Coils are tube -in-tube ‘steam distributing ’ typ e to eliminate risk of con- densate freezing.
271846-YTG-B-0208 26 Johnson Controls Unitary Products FIGURE 1 1 - TYPICAL W A TER-SIDE ECONOMIZER PHYSICAL CONFIGURA TION.
271846-YTG-B-0208 Johnson Controls Unitary Products 27 FIGURE 12 - TYPICAL W A TER-S IDE ECONOMIZER PIPING SCHEMA TIC.
Subject to change without notice. Print ed in U. S.A. 271846-YTG-B-0208 Copyright © 2008 by Johnson Controls, Inc. All rights reserved . Supersedes: 271846- YTG-A-0906 Johnson Contro ls Unitary Produ.
Ein wichtiger Punkt beim Kauf des Geräts York CU060 - 300 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie York CU060 - 300 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für York CU060 - 300 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von York CU060 - 300 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über York CU060 - 300 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon York CU060 - 300 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von York CU060 - 300 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit York CU060 - 300. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei York CU060 - 300 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.