FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TECHNICAL GUIDE SPLIT -SYSTEM A IR CONDITIONERS 13 SEER A Y012MA321 THRU 036 (1 THRU 3 NOMINAL T ONS, 1 PH) Due to conti nu ou s prod uc t improvement, speci fic a t io ns are subject to change with out notice.
246814-YTG-D-0606 2 Unitary Products Group 1. Dual element fuses or HACR circuit breaker . 2. The Unit Charge is correct for the out door unit, matched indoor coil and 15 feet of re frig erant tubing.
246814-YTG-D-0606 Unitary Products Group 3 Additional R-22 Charge / TXV for V arious Matched Systems Outdoor Unit A Y012MA321 A Y018MA321 A Y024MA321 A Y030MA321 A Y036MA321 Required TXV 1 TVM2A1 1 TV.
246814-YTG-D-0606 4 Unitary Products Group FOOTNOTES: * This system does not achieve 13 SE ER 1. Systems matched with furnace or air hand lers not equipped with blower-off delays may re quire blower T ime Delay Kit #6918A501 1 2. These orifices are factory mounted in the flow device of each indoor coil 3.
246814-YTG-D-0606 Unitary Products Group 5 1. G4FD coils available with a factory inst alled horizont a l drain pan. See price p ages for specific model number .
246814-YTG-D-0606 6 Unitary Products Group 1. Requires a 2FD Blower T ime Delay unless a standard furnace is equipped with one. 2. TXV = Use 1 TVM2* kit on non-fact ory installed TXV coils. ** Refer to Quick Selection Chart for specific fu rnace mat ch-up.
246814-YTG-D-0606 Unitary Products Group 7 COOLING CAP ACI TY - V ariable S peed Furnaces UNIT MODEL V ARIABLE S PEED COIL MODEL W COOLING FURNACE MODEL RATED CFM NET MBH SEER EER T OTAL SENS. A Y018MA321 PV8*A12 FC/MC/PC18A 14 600 18.4 12.8 14.50 12.
246814-YTG-D-0606 8 Unitary Products Group 1. G4FD coils available with a factory inst alled horizont a l drain pan. See price p ages for specific model number .
246814-YTG-D-0606 Unitary Products Group 9 ACCESSORIES* Refer to Price Manual for specific mo del numbers. OFF CYCL E TIMER DELA Y - Provides a 5-minute off cycle to pre- vent rapid recycling of the compressor .
246814-YTG-D-0606 10 Unitary Products Group TYPICAL INST ALLA TION THERMOSTA T SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT TO INDOOR COIL TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 2 WIRING NEC CLASS 1 WIRING NOTE :ALL OUTDOOR WIRING MUST BE WEATHERPROOF .
246814-YTG-D-0606 Unitary Products Group 11 Multipliers for determining the perfo rmance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), se.
246814-YTG-D-0606 12 Unitary Products Group Multipliers for determining the perfo rmance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), se.
246814-YTG-D-0606 Unitary Products Group 13 Multipliers for determining the perfo rmance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), se.
246814-YTG-D-0606 14 Unitary Products Group Multipliers for determining the perfo rmance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), se.
246814-YTG-D-0606 Unitary Products Group 15 Multipliers for determining the perfo rmance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), se.
Subject to change without notice. Printed in U. S.A. 246814-YTG-D-0606 Copyright © by Y ork International Corp. 20 06. All rights reserved. Supersedes: 246814-YTG-C-0506 Unitary 5005 Norman Product Y.
Ein wichtiger Punkt beim Kauf des Geräts York AY012MA321 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie York AY012MA321 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für York AY012MA321 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von York AY012MA321 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über York AY012MA321 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon York AY012MA321 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von York AY012MA321 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit York AY012MA321. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei York AY012MA321 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.