Benutzeranleitung / Produktwartung ETL-ES-Comet-WH09 des Produzenten Westinghouse
Zur Seite of 24
ETL-ES-Comet-WH09 OWNER'S MANUAL MANUAL DEL USUARIO MR Comet TM Please write model number here for future reference: / Por favor , incluya el número del modelo aquí para futura referencia: Net W eight: 17.
2 ETL-ES-Comet-WH09 SAFETY TIPS OBSERVE THE FOLLOWING: READ AND SA VE THESE INSTRUC TIONS W ARNING: T O REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY , MOUNT T O OUTLET BO X MARKED " AC CEPT ABLE FOR F AN SUPPORT" , AND USE THE OUTLET SCREWS PROVIDED WITH THE OUTLET BOX.
3 ETL-ES-Comet-WH09 C ONSEJOS DE SEGURIDAD HAGA L O SIGUIENTE: LEA Y GUARDE EST AS INSTRUCCIONES ADVERTENCIA: P ARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O LESIONES PERSONALES, MONTE EL V.
4 ETL-ES-Comet-WH09 FEA TURES CARACTERÍSTICAS DOWNROD INST ALLA TION INST ALACIÓN CON V ARILLA VERTICAL For normal ceilings Para cielorrasos normales V AUL TED CEILING INST ALLA TION INST ALACIÓN P.
5 ETL-ES-Comet-WH09 Unpack and inspect fan carefully to be certain all contents are included. T urn off power at fuse box to avoid possible electrical shock.
6 ETL-ES-Comet-WH09 MOUNTING BRACKET INST ALLA TION INST ALACIÓN CON SOPOR TE DE MONT AJE 3 Remove the screws and star washers from the two mating holes (1) on the canopy . Loosen (do not remove) t he sc r e w s i n t h e m a t i ng sl o t s ( 2 ) o n t h e c a n op y .
7 ETL-ES-Comet-WH09 MOUNTING BRACKET INST ALLA TION I N S T A L A C I Ó N CO N S O P OR TE DE MONT AJE Install mounting bracket to outlet box in ceiling using the screws and washers provided with the outlet box. Instale el soporte de montaje a la caja de embutir del cielorraso con la tornillería suministrada con la caja de embutir .
8 8 ETL-ES-Comet-WH09 FLUSH MOUNT OPTION OPCIÓN DE INST ALACIÓN AL RAS 6 G ui d e m o t o r w i r e s th r o u g h t h e b a s e o f t he ca n o p y a s s h o w n a nd at t a c h c a n o p y directly to top of motor housing with flush mount screws and lock washers provided.
9 ETL-ES-Comet-WH09 8 2 1 3 F ee d m o t o r l e a d w i re s t h r o u g h d o w nr o d / c a n o p y a ss e m b l y a n d i n s er t d o w n r o d i n t o d ow n r o d y o k e . M ak e s u r e t o a l i g n h o le in d o w n r o d w i t h t h e ho l e i n d o w n r o d y o ke .
10 ETL-ES-Comet-WH09 EXTENDED DOWNROD OPTION OPCIÓN CON V ARILLA VER TICAL MÁS LARGA 10 S li d e d o w n r o d b a ll ( 1 ) o f f o f d o w n r o d a nd re m o v e p i n ( 2 ) . D es l i c e l a e s f e r a de la va r i l l a v e r t ic a l ( 1 ) h a s t a s e p ar a r l a d e l a va r i l l a v e r t i ca l y q u i t e e l p a s a d or (2 ) .
11 ETL-ES-Comet-WH09 12 F ee d m o t o r l e a d w i re s t h r o u g h d o w nr o d / c a n o p y a ss e m b l y a n d i n s er t d o w n r o d i n t o d ow n r o d y o k e . M a ke s u r e t o a l i g n h o l e i n d ow n r o d w i t h t h e h ol e i n d o w n r o d y o k e.
12 ETL-ES-Comet-WH09 MOUNTING MONT AJE 14 W it h b r a c k e t h o l di n g f a n a s s e m b ly , m a ke el e c t r i c a l c o nn e c t i o n s u s in g t h e following step for wiring instructions.
13 ETL-ES-Comet-WH09 WIRING OPTIONS OPCIÓN DE CABLEADO 16 White (common) Black (hot) Blue* (hot) Main (ground) White (common) Fan Switch (hot) Light Switch (hot) Green (ground) From Fan: From House: (connect) (connect) (connect) (connect) *Attach blue wire only if attaching light kit with fan.
14 ETL-ES-Comet-WH09 SECURE TO CEILING ASEGURE EL VENTILADOR AL CIELORRASO 1 3 2 The canopy has two mating slots (1) and two mating holes (2). Position both slots on canopy directly under and in line with two screws in the mounting bracket (3). Lift the canopy , allowing the two screws to slide into the mating slots.
15 ETL-ES-Comet-WH09 BLADE INST ALLA TION INST ALACIÓN DE LAS P ALET AS Check the motor for plastic shipping stabilizer tabs (1), and remove them if they are present. Attach blade assembly to motor using the noise-dampening motor gaskets (2) and motor screws provided.
16 ETL-ES-Comet-WH09 LIGHT FIXTURE INST ALLA TION INST ALACIÓN DEL AR TEF ACTO LUMINOSO Install light bulbs (included). Instale las bombillas de luz (incluidas). 20 22 Screw in retaining disks to hold globe in place. Atornille los tornillos de retención para sostener el globo en su sitio.
17 ETL-ES-Comet-WH09 Assemble decorative fob and extension chains from hardware bag to fan pull chains by inserting end of chain into chain coupling. Confirm chains are held by lightly pulling both chains in coupling.
18 ETL-ES-Comet-WH09 Operation T urn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off. Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on.
19 ETL-ES-Comet-WH09 Operación Encienda el ventilador y verifique su funcionamiento. La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera: 1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado.
20 ETL-ES-Comet-WH09 TROUBLESHOOTING GUIDE If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly , installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart.
21 ETL-ES-Comet-WH09 GUÍA P ARA SOLUCIONAR PROBLEMAS Si tiene dificultades para hacer funcionar su nuevo ventilador , podría ser a causa del armado, instalación o cableado incorrectos. En algunos casos, estos errores de instalación podrían ser confundidos con defectos.
22 ETL-ES-Comet-WH09.
23 ETL-ES-Comet-WH09 # Description 1 . . . . . . . . . . . . . . . . . . Mounting Bracket 2 . . . . . . . . . . . . . . . . . . Blade Bracket 3 . . . . . . . . . . . . . . . . . . Blade 4 . . . . . . . . . . . . . . . . . . Glass 5 . . . . . . . . . .
ETL-ES-Comet-WH09 Westinghouse Lighting Corporation 12401 McNulty Road Philadelphia, PA 19154 U.S.A. Westinghouse Lighting Corporation, a Westinghouse Electric Corporation licensee is a registered tra.
Ein wichtiger Punkt beim Kauf des Geräts Westinghouse ETL-ES-Comet-WH09 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Westinghouse ETL-ES-Comet-WH09 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Westinghouse ETL-ES-Comet-WH09 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Westinghouse ETL-ES-Comet-WH09 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Westinghouse ETL-ES-Comet-WH09 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Westinghouse ETL-ES-Comet-WH09 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Westinghouse ETL-ES-Comet-WH09 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Westinghouse ETL-ES-Comet-WH09. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Westinghouse ETL-ES-Comet-WH09 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.