RPB+ Remote Power Boot Switch Preliminary Draft May , 1996 User's Guide.
.
1. Introduction Network equipment sometimes "locks-up", making it impossible to communicate. The RPB+ Remote Power Boot Switch can switch AC power on 5 individually controlled plugs, allowing attached equipment to reset (re-boot). ASCII commands are sent to the RS-232 Control Port to select plugs, and specify On, Off, or Boot operations.
2. Unit Description 2.1. Front Panel As shown in Figure 1, the RPB+ front panel includes a series of LED indicators which function as follows: À POWER ON: Lights when AC Power is applied to the RPB+. Á DA T A INPUT : Flashes when ASCII commands are received at the Control Port.
2.2. Back Panel As shown in Figure 2, the RPB+ back panel includes the following items: À Switched AC Outlets (Plug s1-5 ) : For connection to up to five AC devices. Each outlet is capable of switching up to 15 Amps. The total for all five outlets must not exceed 15 Amps.
3. Installation 3.1. SetUp Switches The SetUp Switches select the baud rate and Off T ime, and enable/disable the Password feature and Read Only Mode. If switch settings are changed while the unit is powered On, press the Default Button to re-read switches.
3.2.1. Connecting to a Modem When connecting directly to an external modem, use a standard A T to Modem cable. Make certain the modem is initialized at the same baud rate as the RPB+ (SetUp Switch 1). The modem must be placed in Auto-Answer mode, and set to answer in one ring.
4. Start-Up / Configuration 1. Access the RPB+ Command Mode: The RPB+ is transparent to parity and will accept 7 or 8 bit characters, but will always answer back at 8 bits, no parity . Make certain your communications program (e.g. ProComm) is set for the appropriate baud rate, bits, and parity .
b) Password: T o re-define the password (Default = [Enter] ), key in the new password (up to 8 characters) and press [Enter] . The password can include blank spaces and higher order ASCII characters. Note that the Backspace key will not function during password definition.
4.1. The Power-Up Default String The Power-Up Default String allows the user to select default On/Off conditions for each switched AC outlet. When the RPB+ is powered up, or when the /D command (Set Defaults) is invoked, each outlet will be set according to the Default String.
5. Operation The device connected to the Control Port must send ASCII characters at the same data rate as the RPB+. The unit accepts 8 bits no parity , or 7 bits even or odd parity , but will always answer back at 8 bits, no parity . Access the RPB+ Command Mode as described in Section 4, Step 1.
6. Set Plugs to Default: T o set all plugs to the Power-Up Defaults, type /D [Enter] . Note that if the Default String includes missing or invalid characters, the /D command will not function. 7. Exit: T o exit from command mode, type /X [Enter] . Note: When the /n ON/OFF/BOOT command is invoked, the port ( n ) must be specified by number .
Appendix A: Specifications Switched Power Plugs: 5 code-selectable AC plugs rated 15 amps max. Each. T otal switched power for all plugs not to exceed 15 amps. Unit initially powers up to ON condition. RS232 Port: DB9 Connector: A 9 Pin Male connector wired in a DTE configuration.
Customer Service Customer Service hours are from 8:00 AM to 5:00 PM, PST , Monday through Friday . When calling, please be prepared to give the name and make of the unit, its serial number and a description of its symptoms.
.
· · · ·.
Ein wichtiger Punkt beim Kauf des Geräts Western Telematic 12651 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Western Telematic 12651 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Western Telematic 12651 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Western Telematic 12651 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Western Telematic 12651 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Western Telematic 12651 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Western Telematic 12651 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Western Telematic 12651. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Western Telematic 12651 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.